Skip to main content
Erschienen in: International Ophthalmology 3/2018

09.06.2017 | Original Paper

Effect of refractive status on Valsalva-induced anterior segment changes

verfasst von: Necip Kara, Serhat Kenan

Erschienen in: International Ophthalmology | Ausgabe 3/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To evaluate the effect of the Valsalva maneuver (VM) on anterior segment parameters and its association with refractive status.

Method

In this prospective study, 120 eyes of 120 subjects were evaluated. Subjects were divided into three groups: myopic (n = 40 patients), hyperopic (n = 40 patients), and emmetropic (control group, n = 40 subjects). The anterior segment parameters, including keratometric, pachymetric, and anterior chamber parameters, were measured using the Sirius System (Costruzione Strumenti Oftalmici, Florence, Italy) before and during VM.

Results

There was no statistically significant difference in corneal parameters including keratometric and pachymetric values at rest or during VM in myopic, hyperopic, and control groups (p > 0.05 for all). In the myopic and control groups, anterior chamber depth, anterior chamber volume (ACV), and anterior chamber angle (ACA) were significantly decreased during VM. In the hyperopic group, only anterior chamber depth was significantly decreased during VM, while ACV and ACA did not significantly change.

Conclusion

The Valsalva maneuver may cause significant narrowing in anterior chamber depth, anterior chamber volume, and anterior chamber angle in the myopic and emmetropic groups, whereas it may affect only anterior chamber depth in the hyperopic group.
Literatur
1.
Zurück zum Zitat Rafuse PE, Mills DW, Hooper PL, Chang TS, Wolf R (1994) Effects of Valsalva’s manoeuvre on intraocular pressure. Can J Ophthalmol 29:73–76PubMed Rafuse PE, Mills DW, Hooper PL, Chang TS, Wolf R (1994) Effects of Valsalva’s manoeuvre on intraocular pressure. Can J Ophthalmol 29:73–76PubMed
2.
Zurück zum Zitat Liu WC, Lee SM, Graham AD, Lin MC (2011) Effects of eye rubbing and breath holding on corneal biomechanical properties and intraocular pressure. Cornea 30:855–860CrossRefPubMed Liu WC, Lee SM, Graham AD, Lin MC (2011) Effects of eye rubbing and breath holding on corneal biomechanical properties and intraocular pressure. Cornea 30:855–860CrossRefPubMed
3.
Zurück zum Zitat Ladjimi A, Zaouali S, Messaoud R et al (2002) Valsalva retinopathy induced by labour. Eur J Ophthalmol 12:336–338CrossRefPubMed Ladjimi A, Zaouali S, Messaoud R et al (2002) Valsalva retinopathy induced by labour. Eur J Ophthalmol 12:336–338CrossRefPubMed
5.
Zurück zum Zitat Zebrowska A, Gasior Z, Jastrzebski D (2013) Cardiovascular effects of the Valsalva maneuver during static arm exercise in elite power lifting athletes. Adv Exp Med Biol 755:335–342CrossRefPubMed Zebrowska A, Gasior Z, Jastrzebski D (2013) Cardiovascular effects of the Valsalva maneuver during static arm exercise in elite power lifting athletes. Adv Exp Med Biol 755:335–342CrossRefPubMed
6.
Zurück zum Zitat Choudhry N, Rao RC (2014) Images in clinical medicine. Valsalva retinopathy. N Engl J Med 20:370 Choudhry N, Rao RC (2014) Images in clinical medicine. Valsalva retinopathy. N Engl J Med 20:370
7.
Zurück zum Zitat Pekel G, Acer S, Yagci R, Kaya H, Pekel E (2014) Impact of Valsalva maneuver on corneal morphology and anterior chamber parameters. Cornea 33:271–273CrossRefPubMed Pekel G, Acer S, Yagci R, Kaya H, Pekel E (2014) Impact of Valsalva maneuver on corneal morphology and anterior chamber parameters. Cornea 33:271–273CrossRefPubMed
8.
Zurück zum Zitat Zhang Z, Wang X, Jonas JB et al (2014) Valsalva maneuver, intra-ocular pressure, cerebrospinal fluid pressure, optic disc topography: Beijing intracranial and intra-ocular pressure study. Acta Ophthalmol 92:e475–e480CrossRefPubMed Zhang Z, Wang X, Jonas JB et al (2014) Valsalva maneuver, intra-ocular pressure, cerebrospinal fluid pressure, optic disc topography: Beijing intracranial and intra-ocular pressure study. Acta Ophthalmol 92:e475–e480CrossRefPubMed
9.
Zurück zum Zitat Wang BS, Xiao L, Liu J, Dong N, Aung T (2012) Dynamic changes in anterior segment morphology during the Valsalva maneuver assessed with ultrasound biomicroscopy. Invest Ophthalmol Vis Sci 53:7286–7289CrossRefPubMed Wang BS, Xiao L, Liu J, Dong N, Aung T (2012) Dynamic changes in anterior segment morphology during the Valsalva maneuver assessed with ultrasound biomicroscopy. Invest Ophthalmol Vis Sci 53:7286–7289CrossRefPubMed
10.
Zurück zum Zitat Bueno-Gimeno I, España-Gregori E, Gene-Sampedro A, Lanzagorta-Aresti A, Piñero-Llorens DP (2014) Relationship among corneal biomechanics, refractive error, and axial length. Optom Vis Sci 91:507–513CrossRefPubMed Bueno-Gimeno I, España-Gregori E, Gene-Sampedro A, Lanzagorta-Aresti A, Piñero-Llorens DP (2014) Relationship among corneal biomechanics, refractive error, and axial length. Optom Vis Sci 91:507–513CrossRefPubMed
11.
Zurück zum Zitat Wei WB, Xu L, Jonas JB et al (2013) Subfoveal choroidal thickness: the Beijing eye study. Ophthalmology 120:175–180CrossRefPubMed Wei WB, Xu L, Jonas JB et al (2013) Subfoveal choroidal thickness: the Beijing eye study. Ophthalmology 120:175–180CrossRefPubMed
12.
Zurück zum Zitat Xu L, You QS, Jonas JB (2010) Refractive error, ocular and general parameters and ophthalmic diseases. The Beijing eye study. Graefes Arch Clin Exp Ophthalmol 248:721–729CrossRefPubMed Xu L, You QS, Jonas JB (2010) Refractive error, ocular and general parameters and ophthalmic diseases. The Beijing eye study. Graefes Arch Clin Exp Ophthalmol 248:721–729CrossRefPubMed
13.
Zurück zum Zitat Buckhurst H, Gilmartin B, Cubbidge RP, Nagra M, Logan NS (2013) Ocular biometric correlates of ciliary muscle thickness in human. Myopia. Ophthalmic Physiol Opt 33:294–304CrossRefPubMed Buckhurst H, Gilmartin B, Cubbidge RP, Nagra M, Logan NS (2013) Ocular biometric correlates of ciliary muscle thickness in human. Myopia. Ophthalmic Physiol Opt 33:294–304CrossRefPubMed
14.
Zurück zum Zitat Mete A, Kimyon S, Uzun I, Kara N (2014) Effects of Valsalva maneuver on ocular biometric parameters: optical low-coherence reflectometry biometer study. Semin Ophthalmol 20:1–4CrossRef Mete A, Kimyon S, Uzun I, Kara N (2014) Effects of Valsalva maneuver on ocular biometric parameters: optical low-coherence reflectometry biometer study. Semin Ophthalmol 20:1–4CrossRef
15.
Zurück zum Zitat Falcão M, Vieira M, Brito P, Rocha-Sousa A, Brandão EM, Falcão-Reis FM (2012) Spectral-domain optical coherence tomography of the choroid during Valsalva maneuver. Am J Ophthalmol 154(687–692):e1 Falcão M, Vieira M, Brito P, Rocha-Sousa A, Brandão EM, Falcão-Reis FM (2012) Spectral-domain optical coherence tomography of the choroid during Valsalva maneuver. Am J Ophthalmol 154(687–692):e1
16.
18.
Zurück zum Zitat Fledelius HC, Goldschmidt E (2009) Oculometry findings in high myopia at adult age: considerations based on oculometric follow-up data over 28 years in a cohort-based Danish high-myopia series. Acta Ophthalmol 88:472–478CrossRefPubMed Fledelius HC, Goldschmidt E (2009) Oculometry findings in high myopia at adult age: considerations based on oculometric follow-up data over 28 years in a cohort-based Danish high-myopia series. Acta Ophthalmol 88:472–478CrossRefPubMed
19.
Zurück zum Zitat Brody S, Erb C, Veit R, Rau H (1999) Intraocular pressure changes: the influence of psychological stress and the Valsalva maneuver. Biol Psychol 51:43–57CrossRefPubMed Brody S, Erb C, Veit R, Rau H (1999) Intraocular pressure changes: the influence of psychological stress and the Valsalva maneuver. Biol Psychol 51:43–57CrossRefPubMed
20.
Zurück zum Zitat Rosen DA, Johnston VC (1959) Ocular pressure patterns in the Valsalva maneuver. Arch Ophthalmol 62:810–816CrossRefPubMed Rosen DA, Johnston VC (1959) Ocular pressure patterns in the Valsalva maneuver. Arch Ophthalmol 62:810–816CrossRefPubMed
21.
Zurück zum Zitat Aykan U, Erdurmus M, Yilmaz B, Bilge AH (2010) Intraocular pressure and ocular pulse amplitude variations during the Valsalva maneuver. Graefes Arch Clin Exp Ophthalmol 248:1183–1186CrossRefPubMed Aykan U, Erdurmus M, Yilmaz B, Bilge AH (2010) Intraocular pressure and ocular pulse amplitude variations during the Valsalva maneuver. Graefes Arch Clin Exp Ophthalmol 248:1183–1186CrossRefPubMed
Metadaten
Titel
Effect of refractive status on Valsalva-induced anterior segment changes
verfasst von
Necip Kara
Serhat Kenan
Publikationsdatum
09.06.2017
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 3/2018
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-017-0583-6

Weitere Artikel der Ausgabe 3/2018

International Ophthalmology 3/2018 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.