Skip to main content
Erschienen in: Journal of Medical Systems 3/2017

01.03.2017 | Mobile & Wireless Health

Effect of the Implementation of a New Electronic Health Record System on Surgical Case Turnover Time

verfasst von: Joseph McDowell, Albert Wu, Jesse M. Ehrenfeld, Richard D. Urman

Erschienen in: Journal of Medical Systems | Ausgabe 3/2017

Einloggen, um Zugang zu erhalten

Abstract

Many health care providers, hospitals, and hospital systems have adopted new electronic health records (EHR) to streamline patient care and comply with government mandates. Commercial EHR vendors advertise improved efficiency, but few studies have been performed to validate these claims. Therefore, this study was performed to evaluate the effect of deploying a new EHR system on operating room efficiency and surgical case turnover time (TOT) at our institution. Data on TOT were collected after implementation of a new EHR (Epic) from June 2015 to May 2016, which replaced a legacy system of both paper and electronic records. These TOTs were compared to data from the same months in the preceding year. Mean TOT and standard deviations were calculated. The two-sample t-test was used to compare means by month and the F-test was used to compare standard deviations. There was a significant increase in TOT (63.0 vs. 53.0 min, p < 0.001) in the first month after implementation. This improved by the second month (59.0 vs. 53.0 min, p < 0.001), but the relative increase persisted until the end of the fifth month after which it remained around the pre-implementation baseline until the end of the study. The standard deviation significantly decreased after the fourth month post-implementation and persisted throughout the studied period. We found that implementation of an EHR led to a significant decrease in efficiency that persisted for five months. While EHRs have the potential to improve hospital workflow, caution is advised in the case of operating room implementation. While the mean TOT did not improve beyond the pre-implementation baseline, the standard deviation was significantly improved after the first four months.
Literatur
1.
Zurück zum Zitat Blumenthal, D., and Tavenner, M., The “meaningful use” regulation for electronic health records. N. Engl. J. Med., 2010. doi:10.1056/NEJMp1006114. Blumenthal, D., and Tavenner, M., The “meaningful use” regulation for electronic health records. N. Engl. J. Med., 2010. doi:10.​1056/​NEJMp1006114.
4.
Zurück zum Zitat Elson, R.B., and Connelly, D.P., Computerized patient records in primary care: their role in mediating guideline-driven physician behavior change. Arch. Fam. Med. 4:698–705, 1995.CrossRefPubMed Elson, R.B., and Connelly, D.P., Computerized patient records in primary care: their role in mediating guideline-driven physician behavior change. Arch. Fam. Med. 4:698–705, 1995.CrossRefPubMed
5.
Zurück zum Zitat Hunt, D.L., Haynes, R.B., Hanna, S.E., and Smith, K., Effects of computer-based clinical decision support systems on physician performance and patient outcomes: a systematic review. JAMA. 280:1339–1346, 1998.CrossRefPubMed Hunt, D.L., Haynes, R.B., Hanna, S.E., and Smith, K., Effects of computer-based clinical decision support systems on physician performance and patient outcomes: a systematic review. JAMA. 280:1339–1346, 1998.CrossRefPubMed
6.
Zurück zum Zitat O’Connor, P.J., Crain, A.L., Rush, W.A., Sperl-Hillen, J.M., Gutenkauf, J.J., and Duncan, J.E., Impact of an electronic medical record on diabetes quality of care. Ann. Fam. Med. 3:300–306, 2005.CrossRefPubMedPubMedCentral O’Connor, P.J., Crain, A.L., Rush, W.A., Sperl-Hillen, J.M., Gutenkauf, J.J., and Duncan, J.E., Impact of an electronic medical record on diabetes quality of care. Ann. Fam. Med. 3:300–306, 2005.CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Feldstein, A., Elmer, P.J., Smith, D.H., Herson, M., Orwoll, E., Chen, C., et al., Electronic medical record reminder improves osteoporosis management after a fracture: a randomized, controlled trial. J. Am. Geriatr. Soc. 54:450–457, 2006.CrossRefPubMed Feldstein, A., Elmer, P.J., Smith, D.H., Herson, M., Orwoll, E., Chen, C., et al., Electronic medical record reminder improves osteoporosis management after a fracture: a randomized, controlled trial. J. Am. Geriatr. Soc. 54:450–457, 2006.CrossRefPubMed
8.
Zurück zum Zitat Kullar, R., Goff, D.A., Schulz, L.T., Fox, B.C., and Rose, W.E., The “epic” challenge of optimizing antimicrobial stewardship: the role of electronic medical records and technology. Clin. Infect. Dis. 57:1005–1013, 2013.CrossRefPubMed Kullar, R., Goff, D.A., Schulz, L.T., Fox, B.C., and Rose, W.E., The “epic” challenge of optimizing antimicrobial stewardship: the role of electronic medical records and technology. Clin. Infect. Dis. 57:1005–1013, 2013.CrossRefPubMed
9.
Zurück zum Zitat Hillestad, R., Bigelow, J., Bower, A., Girosi, F., Meili, R., Scoville, R., et al., Can electronic medical record systems transform health care? Potential health benefits, savings, and costs. Health Aff. 24:1103–1117, 2005.CrossRef Hillestad, R., Bigelow, J., Bower, A., Girosi, F., Meili, R., Scoville, R., et al., Can electronic medical record systems transform health care? Potential health benefits, savings, and costs. Health Aff. 24:1103–1117, 2005.CrossRef
10.
Zurück zum Zitat Wang, S.J., Middleton, B., Prosser, L.A., Bardon, C.G., Spurr, C.D., Carchidi, P.J., et al., A cost-benefit analysis of electronic medical records in primary care. Am. J. Med. 114:397–403, 2003.CrossRefPubMed Wang, S.J., Middleton, B., Prosser, L.A., Bardon, C.G., Spurr, C.D., Carchidi, P.J., et al., A cost-benefit analysis of electronic medical records in primary care. Am. J. Med. 114:397–403, 2003.CrossRefPubMed
11.
Zurück zum Zitat Hartswood, M., Procter, R., Rouncefield, M., and Slack, R., Making a case in medical work: implications for the electronic medical record. Comput. Supported Coop. Work. 12:241–266, 2003.CrossRef Hartswood, M., Procter, R., Rouncefield, M., and Slack, R., Making a case in medical work: implications for the electronic medical record. Comput. Supported Coop. Work. 12:241–266, 2003.CrossRef
12.
Zurück zum Zitat Crowson, M.G., Vail, C., and Eapen, R.J., Influence of electronic medical record implementation on provider retirement at a major academic medical Centre. J. Eval. Clin. Pract. 22:222–226, 2016.CrossRefPubMed Crowson, M.G., Vail, C., and Eapen, R.J., Influence of electronic medical record implementation on provider retirement at a major academic medical Centre. J. Eval. Clin. Pract. 22:222–226, 2016.CrossRefPubMed
13.
Zurück zum Zitat Forster, M., Bailey, C., Brinkhof, M.W.G., Graber, C., Boulle, A., Spohr, M., et al., Electronic medical record systems, data quality and loss to follow-up: survey of antiretroviral therapy programmes in resource-limited settings. Bull. World Health Organ. 86:939–947, 2008.CrossRefPubMedPubMedCentral Forster, M., Bailey, C., Brinkhof, M.W.G., Graber, C., Boulle, A., Spohr, M., et al., Electronic medical record systems, data quality and loss to follow-up: survey of antiretroviral therapy programmes in resource-limited settings. Bull. World Health Organ. 86:939–947, 2008.CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Walker, J., Pan, E., Johnston, D., Adler-Milstein, J., Bates, D.W., and Middleton, B., The value of health care information exchange and interoperability. Health Aff. (Millwood)., 2005. doi:10.1377/hlthaff.w5.10. Walker, J., Pan, E., Johnston, D., Adler-Milstein, J., Bates, D.W., and Middleton, B., The value of health care information exchange and interoperability. Health Aff. (Millwood)., 2005. doi:10.​1377/​hlthaff.​w5.​10.
15.
Zurück zum Zitat Gordon, T., Paul, S., Lyles, A., and Fountain, J., Surgical unit time utilization review: resource utilization and management implications. J. Med. Syst. 12:169–179, 1988.CrossRefPubMed Gordon, T., Paul, S., Lyles, A., and Fountain, J., Surgical unit time utilization review: resource utilization and management implications. J. Med. Syst. 12:169–179, 1988.CrossRefPubMed
16.
Zurück zum Zitat Eijkemans, M.J.C., van Houdenhoven, M., Nguyen, T., Boersma, E., Steyerberg, E.W., and Kazemier, G., Predicting the unpredictable. Anesthesiology. 112:41–49, 2010.CrossRefPubMed Eijkemans, M.J.C., van Houdenhoven, M., Nguyen, T., Boersma, E., Steyerberg, E.W., and Kazemier, G., Predicting the unpredictable. Anesthesiology. 112:41–49, 2010.CrossRefPubMed
17.
Zurück zum Zitat Peltokorpi, A., How do strategic decisions and operative practices affect operating room productivity? Health Care Manag. Sci. 14:370–382, 2011.CrossRefPubMed Peltokorpi, A., How do strategic decisions and operative practices affect operating room productivity? Health Care Manag. Sci. 14:370–382, 2011.CrossRefPubMed
18.
Zurück zum Zitat Wright, J.G., Roche, A., and Khoury, A.E., Improving on time surgical starts in an operating room. Can. J. Surg. 53(3):167–170, 2010.PubMedPubMedCentral Wright, J.G., Roche, A., and Khoury, A.E., Improving on time surgical starts in an operating room. Can. J. Surg. 53(3):167–170, 2010.PubMedPubMedCentral
19.
Zurück zum Zitat Donham, R.T., Defining measurable OR-PR scheduling, efficiency, and utilization data elements: the association of anesthesia clinical directors procedural times glossary. Int. Anesthesiol. Clin. 36:15, 1998.CrossRefPubMed Donham, R.T., Defining measurable OR-PR scheduling, efficiency, and utilization data elements: the association of anesthesia clinical directors procedural times glossary. Int. Anesthesiol. Clin. 36:15, 1998.CrossRefPubMed
20.
Zurück zum Zitat Donham, R.T., Mazzei, W.J., and Jones, R.L., Association of anesthesia clinical directors’ procedural times glossary: glossary of times used for scheduling and monitoring of diagnostic and therapeutic procedures. Am. J. Anesthesiol. 23:3–12, 1996. Donham, R.T., Mazzei, W.J., and Jones, R.L., Association of anesthesia clinical directors’ procedural times glossary: glossary of times used for scheduling and monitoring of diagnostic and therapeutic procedures. Am. J. Anesthesiol. 23:3–12, 1996.
21.
Zurück zum Zitat Wong, J., Khu, K.J., Kaderali, Z., and Bernstein, M., Delays in the operating room: signs of an imperfect system. Can. J. Surg. 53:189–195, 2010.PubMedPubMedCentral Wong, J., Khu, K.J., Kaderali, Z., and Bernstein, M., Delays in the operating room: signs of an imperfect system. Can. J. Surg. 53:189–195, 2010.PubMedPubMedCentral
22.
Zurück zum Zitat Mazzei, W.J., Operating room start times and turnover times in a university hospital. J. Clin. Anesth. 6:405–408, 1994.CrossRefPubMed Mazzei, W.J., Operating room start times and turnover times in a university hospital. J. Clin. Anesth. 6:405–408, 1994.CrossRefPubMed
23.
Zurück zum Zitat Harders, M., Malangoni, M.A., Weight, S., and Sidhu, T., Improving operating room efficiency through process redesign. Surgery. 140:509–516, 2006.CrossRefPubMed Harders, M., Malangoni, M.A., Weight, S., and Sidhu, T., Improving operating room efficiency through process redesign. Surgery. 140:509–516, 2006.CrossRefPubMed
24.
Zurück zum Zitat Vitez, T.S., and Macario, A., Setting performance standards for an anesthesia department. J. Clin. Anesth. 10:166–175, 1998.CrossRefPubMed Vitez, T.S., and Macario, A., Setting performance standards for an anesthesia department. J. Clin. Anesth. 10:166–175, 1998.CrossRefPubMed
25.
Zurück zum Zitat Wu, A., Kodali, B. S., Flanagan, H., Urman, R. D., Introduction of a new electronic medical system has mixed effects on first surgical case efficiency metrics. J. Clin. Monit. Comput. 2016. Wu, A., Kodali, B. S., Flanagan, H., Urman, R. D., Introduction of a new electronic medical system has mixed effects on first surgical case efficiency metrics. J. Clin. Monit. Comput. 2016.
26.
Zurück zum Zitat Wu, A., Brovman, E.Y., Whang, E.E., Ehrenfeld, J.M., and Urman, R.D., The impact of overestimations of surgical control times across multiple specialties on medical systems. J. Med. Syst. 40:95, 2016.CrossRefPubMed Wu, A., Brovman, E.Y., Whang, E.E., Ehrenfeld, J.M., and Urman, R.D., The impact of overestimations of surgical control times across multiple specialties on medical systems. J. Med. Syst. 40:95, 2016.CrossRefPubMed
27.
Zurück zum Zitat Kodali, B.S., Kim, K.D., Flanagan, H., Ehrenfeld, J.M., and Urman, R.D., Variability of subspecialty-specific anesthesia-controlled times at two academic institutions. J. Med. Syst. 38:11, 2014.CrossRefPubMed Kodali, B.S., Kim, K.D., Flanagan, H., Ehrenfeld, J.M., and Urman, R.D., Variability of subspecialty-specific anesthesia-controlled times at two academic institutions. J. Med. Syst. 38:11, 2014.CrossRefPubMed
Metadaten
Titel
Effect of the Implementation of a New Electronic Health Record System on Surgical Case Turnover Time
verfasst von
Joseph McDowell
Albert Wu
Jesse M. Ehrenfeld
Richard D. Urman
Publikationsdatum
01.03.2017
Verlag
Springer US
Erschienen in
Journal of Medical Systems / Ausgabe 3/2017
Print ISSN: 0148-5598
Elektronische ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-017-0690-y

Weitere Artikel der Ausgabe 3/2017

Journal of Medical Systems 3/2017 Zur Ausgabe

Transactional Processing Systems

Privacy-Preserving Integration of Medical Data