Skip to main content
Erschienen in:

06.01.2022 | Original Paper

Effect of white-to-white corneal diameter on biomechanical indices assessed by Pentacam Scheimpflug corneal tomography and corneal visualization Scheimpflug technology

verfasst von: Qinghong Lin, Zhengwei Shen

Erschienen in: International Ophthalmology | Ausgabe 5/2022

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To provide evidence for more accurate evaluation of refractive surgery candidates in clinics, this retrospective study investigated the effect of corneal diameter on the biomechanical indices assessed by Pentacam Scheimpflug cornea tomography (Pentacam) and corneal visualization Scheimpflug technology (Corvis ST).

Methods

The relevant data were collected of 132 eyes from 132 participants with moderate myopia who were candidates for refractive surgery. Eligible participants were apportioned to 2 groups based on the white-to-white (WTW) corneal diameter: Group A, ≤ 11.5 mm, and Group B, ≥ 11.6 mm. A single clinician performed Pentacam and Corvis ST imaging on each subject for 3 consecutive measurements, and the means were used for statistical analyses.

Results

Each group comprised 66 eyes. As measured by Pentacam, the 2 groups were comparable regarding Df and Da. For other measurements, Group A had significantly higher K1, K2, Db, Dp, Dt, Do, PPImin, PPImax, PPIavg, while Group B had significantly higher CCT, BFSf, BFSb, and ARTmax. Corvis ST data included DA ratio, SPA1, CBI, TBI, and ARTh. Only the latter showed a significant difference, with ARTh of group A (437.04 ± 76.60) larger than group B (470.46 ± 103.36, p = 0.04).

Conclusion

In a Chinese population, WTW corneal diameter showed effect on biomechanical indices assessed by Pentacam and Corvis ST. Personalized evaluation of these measurements based on corneal diameter should improve the sensitivity and specificity for screening of keratoconus by these devices.
Literatur
1.
Zurück zum Zitat Wu Y, Tian L, Wang LQ, Huang YF (2016) Efficacy and safety of lasik combined with accelerated corneal collagen cross-linking for myopia: six-month study. Biomed Res Int 2016:5083069PubMedPubMedCentral Wu Y, Tian L, Wang LQ, Huang YF (2016) Efficacy and safety of lasik combined with accelerated corneal collagen cross-linking for myopia: six-month study. Biomed Res Int 2016:5083069PubMedPubMedCentral
2.
Zurück zum Zitat Chen L, Ye T, Yang X (2011) Evaluation of the long-term effects of photorefractive keratectomy correction for myopia in China. Eur J Ophthalmol 21:355–362CrossRef Chen L, Ye T, Yang X (2011) Evaluation of the long-term effects of photorefractive keratectomy correction for myopia in China. Eur J Ophthalmol 21:355–362CrossRef
3.
Zurück zum Zitat Jin SX, Dackowski E, Chuck RS (2020) Risk factors for postlaser refractive surgery corneal ectasia. Curr Opin Ophthalmol 31:288–292CrossRef Jin SX, Dackowski E, Chuck RS (2020) Risk factors for postlaser refractive surgery corneal ectasia. Curr Opin Ophthalmol 31:288–292CrossRef
4.
Zurück zum Zitat Santhiago MR, Giacomin NT, Smadja D, Bechara SJ (2016) Ectasia risk factors in refractive surgery. Clin Ophthalmol 10:713–720CrossRef Santhiago MR, Giacomin NT, Smadja D, Bechara SJ (2016) Ectasia risk factors in refractive surgery. Clin Ophthalmol 10:713–720CrossRef
5.
Zurück zum Zitat Bao F, Geraghty B, Wang Q, Elsheikh A (2016) Consideration of corneal biomechanics in the diagnosis and management of keratoconus: is it important? Eye Vis (Lond) 3:18CrossRef Bao F, Geraghty B, Wang Q, Elsheikh A (2016) Consideration of corneal biomechanics in the diagnosis and management of keratoconus: is it important? Eye Vis (Lond) 3:18CrossRef
6.
Zurück zum Zitat Motlagh MN, Moshirfar M, Murri MS, Skanchy DF, Momeni-Moghaddam H, Ronquillo YC, Hoopes PC (2019) Pentacam(R) corneal tomography for screening of refractive surgery candidates: a review of the literature, part I. Med Hypothesis Discov Innov Ophthalmol 8:177–203PubMedPubMedCentral Motlagh MN, Moshirfar M, Murri MS, Skanchy DF, Momeni-Moghaddam H, Ronquillo YC, Hoopes PC (2019) Pentacam(R) corneal tomography for screening of refractive surgery candidates: a review of the literature, part I. Med Hypothesis Discov Innov Ophthalmol 8:177–203PubMedPubMedCentral
7.
Zurück zum Zitat Ruisenor Vazquez PR, Galletti JD, Minguez N, Delrivo M, Fuentes Bonthoux F, Pfortner T, Galletti JG (2014) Pentacam Scheimpflug tomography findings in topographically normal patients and subclinical Keratoconus cases. Am J Ophthalmol 158:32–40CrossRef Ruisenor Vazquez PR, Galletti JD, Minguez N, Delrivo M, Fuentes Bonthoux F, Pfortner T, Galletti JG (2014) Pentacam Scheimpflug tomography findings in topographically normal patients and subclinical Keratoconus cases. Am J Ophthalmol 158:32–40CrossRef
8.
Zurück zum Zitat Chan E, Chong EW, Lingham G, Stevenson LJ, Sanfilippo PG, Hewitt AW, Mackey DA, Yazar S (2021) Prevalence of Keratoconus based on Scheimpflug imaging: the raine study. Ophthalmology 128:515–521CrossRef Chan E, Chong EW, Lingham G, Stevenson LJ, Sanfilippo PG, Hewitt AW, Mackey DA, Yazar S (2021) Prevalence of Keratoconus based on Scheimpflug imaging: the raine study. Ophthalmology 128:515–521CrossRef
9.
Zurück zum Zitat Bamdad S, Sedaghat MR, Yasemi M, Vahedi A (2020) Sensitivity and specificity of Belin Ambrosio enhanced ectasia display in early diagnosis of Keratoconus. J Ophthalmol 2020:7625659PubMedPubMedCentral Bamdad S, Sedaghat MR, Yasemi M, Vahedi A (2020) Sensitivity and specificity of Belin Ambrosio enhanced ectasia display in early diagnosis of Keratoconus. J Ophthalmol 2020:7625659PubMedPubMedCentral
10.
Zurück zum Zitat Belin MW, Villavicencio OF, Ambrosio RR Jr (2014) Tomographic parameters for the detection of keratoconus: suggestions for screening and treatment parameters. Eye Contact Lens 40:326–330CrossRef Belin MW, Villavicencio OF, Ambrosio RR Jr (2014) Tomographic parameters for the detection of keratoconus: suggestions for screening and treatment parameters. Eye Contact Lens 40:326–330CrossRef
11.
Zurück zum Zitat Huseynli S, Salgado-Borges J, Alio JL (2018) Comparative evaluation of Scheimpflug tomography parameters between thin non-keratoconic, subclinical keratoconic, and mild keratoconic corneas. Eur J Ophthalmol 28:521–534CrossRef Huseynli S, Salgado-Borges J, Alio JL (2018) Comparative evaluation of Scheimpflug tomography parameters between thin non-keratoconic, subclinical keratoconic, and mild keratoconic corneas. Eur J Ophthalmol 28:521–534CrossRef
12.
Zurück zum Zitat Ma J, Wang Y, Wei P, Jhanji V (2018) Biomechanics and structure of the cornea: implications and association with corneal disorders. Surv Ophthalmol 63:851–861CrossRef Ma J, Wang Y, Wei P, Jhanji V (2018) Biomechanics and structure of the cornea: implications and association with corneal disorders. Surv Ophthalmol 63:851–861CrossRef
13.
Zurück zum Zitat Ambrosio R, Ramos I, Luz A, Faria FC, Steinmueller A, Krug M, Belin MW, Roberts CJ (2013) Dynamic ultra high speed Scheimpflug imaging for assessing corneal biomechanical properties. Rev Bras Oftalmol 72:99–102CrossRef Ambrosio R, Ramos I, Luz A, Faria FC, Steinmueller A, Krug M, Belin MW, Roberts CJ (2013) Dynamic ultra high speed Scheimpflug imaging for assessing corneal biomechanical properties. Rev Bras Oftalmol 72:99–102CrossRef
14.
Zurück zum Zitat Zhang M, Zhang F, Li Y, Song Y, Wang Z (2020) Early diagnosis of Keratoconus in Chinese myopic eyes by combining Corvis ST with Pentacam. Curr Eye Res 45:118–123CrossRef Zhang M, Zhang F, Li Y, Song Y, Wang Z (2020) Early diagnosis of Keratoconus in Chinese myopic eyes by combining Corvis ST with Pentacam. Curr Eye Res 45:118–123CrossRef
15.
Zurück zum Zitat Boyd BM, Bai J, Borgstrom M, Belin MW (2020) Comparison of Chinese and North American tomographic parameters and the implications for refractive surgery screening. Asia Pac J Ophthalmol (Phila) 9:117–125CrossRef Boyd BM, Bai J, Borgstrom M, Belin MW (2020) Comparison of Chinese and North American tomographic parameters and the implications for refractive surgery screening. Asia Pac J Ophthalmol (Phila) 9:117–125CrossRef
16.
Zurück zum Zitat Yu AY, Shao H, Pan A, Wang Q, Huang Z, Song B, McAlinden C, Huang J, Chen S (2020) Corneal biomechanical properties in myopic eyes evaluated via Scheimpflug imaging. BMC Ophthalmol 20:279CrossRef Yu AY, Shao H, Pan A, Wang Q, Huang Z, Song B, McAlinden C, Huang J, Chen S (2020) Corneal biomechanical properties in myopic eyes evaluated via Scheimpflug imaging. BMC Ophthalmol 20:279CrossRef
17.
Zurück zum Zitat Roshdy MMS, Wahba SS, Elkitkat RS, Hakim AM, Fikry RR (2018) Effect of age on Pentacam Keratoconus indices. J Ophthalmol 2018:2016564PubMedPubMedCentral Roshdy MMS, Wahba SS, Elkitkat RS, Hakim AM, Fikry RR (2018) Effect of age on Pentacam Keratoconus indices. J Ophthalmol 2018:2016564PubMedPubMedCentral
18.
Zurück zum Zitat Peng YS, Chen M, Tian L, Li H, Li DW, Zhang FF (2020) Influence factors and differences of posterior corneal elevation measured by Pentacam system combined with Corvis ST. Zhonghua Yan Ke Za Zhi 56:110–117PubMed Peng YS, Chen M, Tian L, Li H, Li DW, Zhang FF (2020) Influence factors and differences of posterior corneal elevation measured by Pentacam system combined with Corvis ST. Zhonghua Yan Ke Za Zhi 56:110–117PubMed
19.
Zurück zum Zitat Cao KW, Liu LN, Sun YL, Zhang T, Bai J, Liu T (2020) The influence of different corneal diameters on Belin/Ambrosio enhanced ectasia display of Pentacam corneal topography. Zhonghua Yan Ke Za Zhi 56:761–767PubMed Cao KW, Liu LN, Sun YL, Zhang T, Bai J, Liu T (2020) The influence of different corneal diameters on Belin/Ambrosio enhanced ectasia display of Pentacam corneal topography. Zhonghua Yan Ke Za Zhi 56:761–767PubMed
20.
Zurück zum Zitat Almorin-Fernandez-Vigo I, Sanchez-Guillen I, Fernandez-Vigo JI, Macarro-Merino A, Kudsieh B, Fernandez-Vigo C, Fernandez-Vigo JA (2019) Normative Pentacam anterior and posterior corneal elevation measurements: effects of age, sex, axial length and white-to-white. Int Ophthalmol 39:1955–1963CrossRef Almorin-Fernandez-Vigo I, Sanchez-Guillen I, Fernandez-Vigo JI, Macarro-Merino A, Kudsieh B, Fernandez-Vigo C, Fernandez-Vigo JA (2019) Normative Pentacam anterior and posterior corneal elevation measurements: effects of age, sex, axial length and white-to-white. Int Ophthalmol 39:1955–1963CrossRef
21.
Zurück zum Zitat Vinciguerra R, Ambrosio R Jr, Elsheikh A, Roberts CJ, Lopes B, Morenghi E, Azzolini C, Vinciguerra P (2016) Detection of Keratoconus with a new biomechanical index. J Refract Surg 32:803–810CrossRef Vinciguerra R, Ambrosio R Jr, Elsheikh A, Roberts CJ, Lopes B, Morenghi E, Azzolini C, Vinciguerra P (2016) Detection of Keratoconus with a new biomechanical index. J Refract Surg 32:803–810CrossRef
22.
Zurück zum Zitat Gilani F, Cortese M, Ambrosio RR Jr, Lopes B, Ramos I, Harvey EM, Belin MW (2013) Comprehensive anterior segment normal values generated by rotating Scheimpflug tomography. J Cataract Refract Surg 39:1707–1712CrossRef Gilani F, Cortese M, Ambrosio RR Jr, Lopes B, Ramos I, Harvey EM, Belin MW (2013) Comprehensive anterior segment normal values generated by rotating Scheimpflug tomography. J Cataract Refract Surg 39:1707–1712CrossRef
23.
Zurück zum Zitat Hickson-Curran S, Young G, Brennan N, Hunt C (2016) Chinese and Caucasian ocular topography and soft contact lens fit. Clin Exp Optom 99:149–156CrossRef Hickson-Curran S, Young G, Brennan N, Hunt C (2016) Chinese and Caucasian ocular topography and soft contact lens fit. Clin Exp Optom 99:149–156CrossRef
Metadaten
Titel
Effect of white-to-white corneal diameter on biomechanical indices assessed by Pentacam Scheimpflug corneal tomography and corneal visualization Scheimpflug technology
verfasst von
Qinghong Lin
Zhengwei Shen
Publikationsdatum
06.01.2022
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 5/2022
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-021-02144-x

Neu im Fachgebiet Augenheilkunde

Künstliche Intelligenz in der Medizin – Chancen und Risiken aus ethischer Sicht

Bildgebende Fächer wie die Augenheilkunde bieten vielfältige Möglichkeiten für den nutzbringenden Einsatz künstlicher Intelligenz (KI). Die Auswertung von Bildern und Daten mittels trainierter Algorithmen besitzt das Potenzial, die …

Okuläre Graft-versus-Host-Disease

Die okuläre Graft-versus-Host-Erkrankung („graft-versus-host disease“ [GVHD]) nach allogener hämatopoetischer Stammzelltransplantation (HSCT) stellt überwiegend eine entzündliche und destruierende Augenoberflächenerkrankung mit zunehmender …

Kataraktchirurgie in Subsahara-Afrika – Möglichkeiten und Grenzen

Die Bedeutung von Sehbeeinträchtigung und Blindheit für Individuen und Gesellschaften hat in den letzten Jahren ein hohes Maß an Aufmerksamkeit erfahren. Wesentliche Aspekte dieser Thematik sind im World report on vision der …

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.