Effects of different cadaver preservation methods on muscles and tendons: a morphometric, biomechanical and histological study

verfasst von: Orhan Beger, Meryem İlkay Karagül, Turan Koç, Gülden Kayan, Abdülkadir Cengiz, Şakir Necat Yılmaz, Zeliha Kurtoğlu Olgunus

Erschienen in: Anatomical Science International | Ausgabe 2/2020

Einloggen, um Zugang zu erhalten

Abstract

No prior publication studying the biomechanical and histological properties of cadavers fixed with Logan or modified Logan solution (MLS) was found in the literature. It was aimed in this study to compare MLS fixation and other cadaver preservation procedures regarding the use in basic histological studies, anatomy education and surgical trainings. This study was placed on 35 male 17-week-old Wistar Albino rats. MLS fixated tissues were systematically compared with 10% formalin (F10), saturated salt solution (SSS), Thiel and frozen/thawed (FT) tissues. Organoleptic (color, appearance, flexibility, odor, etc.), morphometric (e.g. length, width and cross-sectional area), biomechanical (Young’s modulus, stiffness, maximum load, etc.) and histological (tendon and muscle fiber integrity, nuclear prominence, blur in microscopy, etc.) analyses were conducted. Organoleptic properties of Thiel and SSS fixated muscles and tendons were better preserved than F10 and MLS. No significant difference was observed in gross morphometric properties (e.g. length, width and cross sectional area) following any of the cadaver and tissue preservation techniques. MLS and F10 was observed to increase the stiffness, Young’s modulus and maximum load parameters of the tendons. Thiel and SSS fixated tendons had similar mechanical properties to fresh and FT tendons. No effect of fixation solutions on tendons is observed in the histological analysis regarding fiber integrity, nuclear prominence, blur in microscopy, shrinkage of tissues. Thiel solution was observed to distort fiber integrity, nuclear prominence and blur the microscopy of muscle tissue. Thiel and SSS fixated muscles and tendons were observed to absorb more stain with Masson’s trichrome staining and appear as darker red. No muscle and tendon shrinkage due to fixative solutions was observed with our fixation method. Pondering the organoleptic (color, appearance, consistency, odor, etc.) and biomechanical analyses (stiffness, Young’s modulus, etc.), Thiel and SSS fixed cadavers are more suitable for purposes as surgical trainings and development of new surgical procedures. However, the change in the micro-anatomical structure of the muscles, especially with the Masson’s trichrome staining, caused by these two solutions should not be overlooked.
Literatur
Zurück zum Zitat Anderson SD (2006) Practical light embalming technique for use in the surgical fresh tissue dissection laboratory. Clin Anat 19:8–11PubMed Anderson SD (2006) Practical light embalming technique for use in the surgical fresh tissue dissection laboratory. Clin Anat 19:8–11PubMed
Zurück zum Zitat Arezzo A, Mintz Y, Allaix ME et al (2007) Total mesorectal excision using a soft and flexible robotic arm: a feasibility study in cadaver models. Surg Endosc 31:264–273 Arezzo A, Mintz Y, Allaix ME et al (2007) Total mesorectal excision using a soft and flexible robotic arm: a feasibility study in cadaver models. Surg Endosc 31:264–273
Zurück zum Zitat Arnout N, Myncke J, Vanlauwe J, Labey L, Lismont D, Bellemans J (2013) The influence of freezing on the tensile strength of tendon grafts: a biomechanical study. Acta Orthop Belg 79:435–443PubMed Arnout N, Myncke J, Vanlauwe J, Labey L, Lismont D, Bellemans J (2013) The influence of freezing on the tensile strength of tendon grafts: a biomechanical study. Acta Orthop Belg 79:435–443PubMed
Zurück zum Zitat Balta JY, Lamb C, Soames RW (2015a) A pilot study comparing the use of Thiel- and formalin-embalmed cadavers in the teaching of human anatomy. Anat Sci Educ 8:86–91PubMed Balta JY, Lamb C, Soames RW (2015a) A pilot study comparing the use of Thiel- and formalin-embalmed cadavers in the teaching of human anatomy. Anat Sci Educ 8:86–91PubMed
Zurück zum Zitat Balta JY, Cronin M, Cryan JF, O’Mahony SM (2015b) Human preservation techniques in anatomy: a 21st century medical education perspective. Clin Anat 28:725–734PubMed Balta JY, Cronin M, Cryan JF, O’Mahony SM (2015b) Human preservation techniques in anatomy: a 21st century medical education perspective. Clin Anat 28:725–734PubMed
Zurück zum Zitat Balta JY, Cronin M, Cryan JF, O’Mahony SM (2017) The utility of cadaver-based approaches for the teaching of human anatomy: a survey of British and Irish anatomy teachers. Anat Sci Educ 10:137–143PubMed Balta JY, Cronin M, Cryan JF, O’Mahony SM (2017) The utility of cadaver-based approaches for the teaching of human anatomy: a survey of British and Irish anatomy teachers. Anat Sci Educ 10:137–143PubMed
Zurück zum Zitat Bedino JH (2003) Embalming chemistry: glutaraldehyde versus formaldehyde. Champion Expand Encycl Mortu Pract 649:2614–2632 Bedino JH (2003) Embalming chemistry: glutaraldehyde versus formaldehyde. Champion Expand Encycl Mortu Pract 649:2614–2632
Zurück zum Zitat Beger B, Beger O, Koç T et al (2018a) Quantitative and neurovascular anatomy of the growing gracilis muscle in the human fetuses. J Craniofac Surg 29:686–690 Beger B, Beger O, Koç T et al (2018a) Quantitative and neurovascular anatomy of the growing gracilis muscle in the human fetuses. J Craniofac Surg 29:686–690
Zurück zum Zitat Beger O, Beger B, Uzmansel D, Erdoğan S, Kurtoğlu Z (2018b) Morphometric properties of the latissimus dorsi muscle in human fetuses for flap surgery. Surg Radiol Anat 40:881–889PubMed Beger O, Beger B, Uzmansel D, Erdoğan S, Kurtoğlu Z (2018b) Morphometric properties of the latissimus dorsi muscle in human fetuses for flap surgery. Surg Radiol Anat 40:881–889PubMed
Zurück zum Zitat Beger O, Dinç U, Beger B, Uzmansel D, Kurtoğlu Z (2018c) Morphometric properties of the levator scapulae, rhomboid major, and rhomboid minor in human fetuses. Surg Radiol Anat 40:449–455PubMed Beger O, Dinç U, Beger B, Uzmansel D, Kurtoğlu Z (2018c) Morphometric properties of the levator scapulae, rhomboid major, and rhomboid minor in human fetuses. Surg Radiol Anat 40:449–455PubMed
Zurück zum Zitat Beger O, Elvan Ö, Keskinbora M, Ün B, Uzmansel D, Kurtoğlu Z (2018d) Anatomy of Master Knot of Henry: a morphometric study on cadavers. Acta Orthop Traumatol Turc 52:134–142PubMedPubMedCentral Beger O, Elvan Ö, Keskinbora M, Ün B, Uzmansel D, Kurtoğlu Z (2018d) Anatomy of Master Knot of Henry: a morphometric study on cadavers. Acta Orthop Traumatol Turc 52:134–142PubMedPubMedCentral
Zurück zum Zitat Beger O, Koç T, Beger B, Kayan G, Uzmansel D, Olgunus ZK (2018e) Quantitative assessment of the growth dynamics of the teres major in human fetuses. Surg Radiol Anat 40:1349–1356PubMed Beger O, Koç T, Beger B, Kayan G, Uzmansel D, Olgunus ZK (2018e) Quantitative assessment of the growth dynamics of the teres major in human fetuses. Surg Radiol Anat 40:1349–1356PubMed
Zurück zum Zitat Beger O, Koç T, Beger B, Uzmansel D, Kurtoğlu Z (2018f) Morphometric properties of the tensor fascia lata muscle in human fetuses. Folia Morphol (Warsz) 77:498–502 Beger O, Koç T, Beger B, Uzmansel D, Kurtoğlu Z (2018f) Morphometric properties of the tensor fascia lata muscle in human fetuses. Folia Morphol (Warsz) 77:498–502
Zurück zum Zitat Belavy D, Ruitenberg MJ, Brijball RB (2011) Feasibility study of realtime three-/four-dimensional ultrasound for epidural catheter insertion. Br J Anaesth 107:438–445PubMed Belavy D, Ruitenberg MJ, Brijball RB (2011) Feasibility study of realtime three-/four-dimensional ultrasound for epidural catheter insertion. Br J Anaesth 107:438–445PubMed
Zurück zum Zitat Benkhadra M, Bouchot A, Gerard J et al (2011) Flexibility of Thiel’s embalmed cadavers: the explanation is probably in the muscles. Surg Radiol Anat 33:365–368PubMed Benkhadra M, Bouchot A, Gerard J et al (2011) Flexibility of Thiel’s embalmed cadavers: the explanation is probably in the muscles. Surg Radiol Anat 33:365–368PubMed
Zurück zum Zitat Bilge O, Çelik S (2017) Cadaver embalming fluid for surgical training courses: modified Larssen solution. Surg Radiol Anat 39:1263–1272PubMed Bilge O, Çelik S (2017) Cadaver embalming fluid for surgical training courses: modified Larssen solution. Surg Radiol Anat 39:1263–1272PubMed
Zurück zum Zitat Burns DM, Bell I, Katchky R et al (2018) Saturated salt solution cadaver-embalming method improves orthopaedic surgical skills training. J Bone Jt Surg Am 100:e104 Burns DM, Bell I, Katchky R et al (2018) Saturated salt solution cadaver-embalming method improves orthopaedic surgical skills training. J Bone Jt Surg Am 100:e104
Zurück zum Zitat Chen L, Wu Y, Yu J et al (2010) Effect of repeated freezing–thawing on the Achilles tendon of rabbits. Knee Surg Sports Traumatol Arthrosc 19:1028–1034PubMed Chen L, Wu Y, Yu J et al (2010) Effect of repeated freezing–thawing on the Achilles tendon of rabbits. Knee Surg Sports Traumatol Arthrosc 19:1028–1034PubMed
Zurück zum Zitat Choi D, Carroll N, Abrahams P (1996) Spinal cord diameters in cadaveric specimens and magnetic resonance scans, to assess embalming artefacts. Surg Radiol Anat 18:133–135PubMed Choi D, Carroll N, Abrahams P (1996) Spinal cord diameters in cadaveric specimens and magnetic resonance scans, to assess embalming artefacts. Surg Radiol Anat 18:133–135PubMed
Zurück zum Zitat Clavert P, Kempf JF, Bonnomet F, Boutemy P, Marcelin L, Kahn JL (2001) Effects of freezing/thawing on the biomechanical properties of human tendons. Surg Radiol Anat 23:259–262PubMed Clavert P, Kempf JF, Bonnomet F, Boutemy P, Marcelin L, Kahn JL (2001) Effects of freezing/thawing on the biomechanical properties of human tendons. Surg Radiol Anat 23:259–262PubMed
Zurück zum Zitat Coleman R, Kogan I (1998) An improved low-formaldehyde embalming fluid to preserve cadavers for anatomy teaching. J Anat 192:443–446PubMedPubMedCentral Coleman R, Kogan I (1998) An improved low-formaldehyde embalming fluid to preserve cadavers for anatomy teaching. J Anat 192:443–446PubMedPubMedCentral
Zurück zum Zitat Comert A, Kokat AM, Akkocaoglu M, Tekdemir I, Akca K, Cehreli MC (2009) Fresh-frozen vs. embalmed bone: is it possible to use formalin-fixed human bone for biomechanical experiments on implants? Clin Oral Implants Res 20:521–525PubMed Comert A, Kokat AM, Akkocaoglu M, Tekdemir I, Akca K, Cehreli MC (2009) Fresh-frozen vs. embalmed bone: is it possible to use formalin-fixed human bone for biomechanical experiments on implants? Clin Oral Implants Res 20:521–525PubMed
Zurück zum Zitat Eisma R, Lamb C, Soames RW (2013) From formalin to Thiel embalming: what changes? One anatomy department’s experiences. Clin Anat 26:564–571PubMed Eisma R, Lamb C, Soames RW (2013) From formalin to Thiel embalming: what changes? One anatomy department’s experiences. Clin Anat 26:564–571PubMed
Zurück zum Zitat Feigl G, Fuchs A, Gries M, Hogan QH, Weninger B, Rosmarin W (2006) A supraomohyoidal plexus block designed to avoid complications. Surg Radiol Anat 28:403–408PubMed Feigl G, Fuchs A, Gries M, Hogan QH, Weninger B, Rosmarin W (2006) A supraomohyoidal plexus block designed to avoid complications. Surg Radiol Anat 28:403–408PubMed
Zurück zum Zitat Fessel G, Frey K, Schweizer A, Calcagni M, Ullrich O, Snedeker JG (2011) Suitability of Thiel embalmed tendons for biomechanical investigation. Ann Anat 193:237–241PubMed Fessel G, Frey K, Schweizer A, Calcagni M, Ullrich O, Snedeker JG (2011) Suitability of Thiel embalmed tendons for biomechanical investigation. Ann Anat 193:237–241PubMed
Zurück zum Zitat Foutz TL, Stone EA, Abrams CF Jr (1992) Effects of freezing on mechanical properties of rat skin. Am J Vet Res 53:788–792PubMed Foutz TL, Stone EA, Abrams CF Jr (1992) Effects of freezing on mechanical properties of rat skin. Am J Vet Res 53:788–792PubMed
Zurück zum Zitat Giannini S, Buda R, Di Caprio F et al (2008) Effects of freezing on the biomechanical and structural properties of human posterior tibial tendons. Int Orthop 32:145–151PubMed Giannini S, Buda R, Di Caprio F et al (2008) Effects of freezing on the biomechanical and structural properties of human posterior tibial tendons. Int Orthop 32:145–151PubMed
Zurück zum Zitat Goyri-O’Neill J, Pais D, Freire de Andrade F et al (2013) Improvement of the embalming perfusion method: the innovation and the results by light and scanning electron microscopy. Acta Med Port 26:188–194PubMed Goyri-O’Neill J, Pais D, Freire de Andrade F et al (2013) Improvement of the embalming perfusion method: the innovation and the results by light and scanning electron microscopy. Acta Med Port 26:188–194PubMed
Zurück zum Zitat Guo S, Schwab A, McLeod G et al (2012) Echogenic regional anaesthesia needles: a comparison study in Thiel cadavers. Ultrasound Med Biol 38:702–707PubMed Guo S, Schwab A, McLeod G et al (2012) Echogenic regional anaesthesia needles: a comparison study in Thiel cadavers. Ultrasound Med Biol 38:702–707PubMed
Zurück zum Zitat Hammer N, Loffler S, Feja C et al (2012) Ethanol–glycerin fixation with thymol conservation: a potential alternative to formaldehyde and phenol embalming. Anat Sci Educ 5:225–233PubMed Hammer N, Loffler S, Feja C et al (2012) Ethanol–glycerin fixation with thymol conservation: a potential alternative to formaldehyde and phenol embalming. Anat Sci Educ 5:225–233PubMed
Zurück zum Zitat Hammer N, Loffler S, Bechmann I, Steinke H, Hadrich C, Feja C (2015) Comparison of modified thiel embalming and ethanol glycerin fixation in an anatomy environment: potentials and limitations of two complementary techniques. Anat Sci Educ 8:74–85PubMed Hammer N, Loffler S, Bechmann I, Steinke H, Hadrich C, Feja C (2015) Comparison of modified thiel embalming and ethanol glycerin fixation in an anatomy environment: potentials and limitations of two complementary techniques. Anat Sci Educ 8:74–85PubMed
Zurück zum Zitat Hansen P, Hassenkam T, Svensson RB et al (2009) Glutaraldehyde cross-linking of tendon mechanical effects at the level of the tendon fascicle and fibril. Connect Tissue Res 50:211–222PubMed Hansen P, Hassenkam T, Svensson RB et al (2009) Glutaraldehyde cross-linking of tendon mechanical effects at the level of the tendon fascicle and fibril. Connect Tissue Res 50:211–222PubMed
Zurück zum Zitat Hayashi S, Homma H, Naito M et al (2014) Saturated salt solution method: a useful cadaver embalming for surgical skills training. Medicine 93:e196PubMedPubMedCentral Hayashi S, Homma H, Naito M et al (2014) Saturated salt solution method: a useful cadaver embalming for surgical skills training. Medicine 93:e196PubMedPubMedCentral
Zurück zum Zitat Hayashi S, Naito M, Kawata S et al (2016) History and future of human cadaver preservation for surgical training: from formalin to saturated salt solution method. Anat Sci Int 91:1–7PubMed Hayashi S, Naito M, Kawata S et al (2016) History and future of human cadaver preservation for surgical training: from formalin to saturated salt solution method. Anat Sci Int 91:1–7PubMed
Zurück zum Zitat Hirpara KM, Sullivan PJ, O’Sullivan ME (2008) The effects of freezing on the tensile properties of repaired porcine flexor tendon. J Hand Surg Am 33:353–358PubMed Hirpara KM, Sullivan PJ, O’Sullivan ME (2008) The effects of freezing on the tensile properties of repaired porcine flexor tendon. J Hand Surg Am 33:353–358PubMed
Zurück zum Zitat Hohmann E, Keough N, Glatt V, Tetsworth K, Putz R, Imhoff A (2019) The mechanical properties of fresh versus fresh/frozen and preserved (Thiel and Formalin) long head of biceps tendons: a cadaveric investigation. Ann Anat 221:186–191PubMed Hohmann E, Keough N, Glatt V, Tetsworth K, Putz R, Imhoff A (2019) The mechanical properties of fresh versus fresh/frozen and preserved (Thiel and Formalin) long head of biceps tendons: a cadaveric investigation. Ann Anat 221:186–191PubMed
Zurück zum Zitat Huang H, Zhang J, Sun K, Zhang X, Tian S (2011) Effects of repetitive multiple freeze-thaw cycles on the biomechanical properties of human flexor digitorum superficialis and flexor pollicis longus tendons. Clin Biomech (Bristol, Avon) 26:419–423 Huang H, Zhang J, Sun K, Zhang X, Tian S (2011) Effects of repetitive multiple freeze-thaw cycles on the biomechanical properties of human flexor digitorum superficialis and flexor pollicis longus tendons. Clin Biomech (Bristol, Avon) 26:419–423
Zurück zum Zitat Jaung R, Cook P, Blyth P (2011) A comparison of embalming fluids for use in surgical workshops. Clin Anat 24:155–161PubMed Jaung R, Cook P, Blyth P (2011) A comparison of embalming fluids for use in surgical workshops. Clin Anat 24:155–161PubMed
Zurück zum Zitat Jung HJ, Vangipuram G, Fisher MB et al (2011) The effects of multiple freeze-thaw cycles on the biomechanical properties of the human bonepatellar tendon-bone allograft. J Orthop Res 29:1193–1198PubMedPubMedCentral Jung HJ, Vangipuram G, Fisher MB et al (2011) The effects of multiple freeze-thaw cycles on the biomechanical properties of the human bonepatellar tendon-bone allograft. J Orthop Res 29:1193–1198PubMedPubMedCentral
Zurück zum Zitat Lee GH, Kumar A, Berkson E, Verma N, Bach BR Jr, Hallab N (2009) A biomechanical analysis of bone–patellar tendon–bone grafts after repeat freeze–thaw cycles in a cyclic loading model. J Knee Surg 22:111–113PubMed Lee GH, Kumar A, Berkson E, Verma N, Bach BR Jr, Hallab N (2009) A biomechanical analysis of bone–patellar tendon–bone grafts after repeat freeze–thaw cycles in a cyclic loading model. J Knee Surg 22:111–113PubMed
Zurück zum Zitat Lewis PB, Williams JM, Hallab N, Virdi A, Yanke A, Cole BJ (2008) Multiple freeze–thaw cycled meniscal allograft tissue: a biomechanical, biochemical, and histologic analysis. J Orthopaed Res 26:49–55 Lewis PB, Williams JM, Hallab N, Virdi A, Yanke A, Cole BJ (2008) Multiple freeze–thaw cycled meniscal allograft tissue: a biomechanical, biochemical, and histologic analysis. J Orthopaed Res 26:49–55
Zurück zum Zitat Liao X, Kemp S, Corner G, Eisma R, Huang Z (2015) Elastic properties of Thiel-embalmed human ankle tendon and ligament. Clin Anat 28:917–924PubMed Liao X, Kemp S, Corner G, Eisma R, Huang Z (2015) Elastic properties of Thiel-embalmed human ankle tendon and ligament. Clin Anat 28:917–924PubMed
Zurück zum Zitat Lloyd GM, Maxwell-Armstrong C, Acheson AG (2011) Fresh frozen cadavers: an under-utilized resource in laparoscopic colorectal training in the United Kingdom. Colorectal Dis 13:303–304 Lloyd GM, Maxwell-Armstrong C, Acheson AG (2011) Fresh frozen cadavers: an under-utilized resource in laparoscopic colorectal training in the United Kingdom. Colorectal Dis 13:303–304
Zurück zum Zitat Lombardero M, Yllera MM, Costa-E-Silva A, Oliveira MJ, Ferreira PG (2017) Saturated salt solution: a further step to a formaldehyde-free embalming method for veterinary gross anatomy. J Anat 231:309–317PubMedPubMedCentral Lombardero M, Yllera MM, Costa-E-Silva A, Oliveira MJ, Ferreira PG (2017) Saturated salt solution: a further step to a formaldehyde-free embalming method for veterinary gross anatomy. J Anat 231:309–317PubMedPubMedCentral
Zurück zum Zitat Maiden NR, Byard RW (2016) Unpredictable tensile strength biomechanics may limit thawed cadaver use for simulant research. Aust J Forensic Sci 48:54–58 Maiden NR, Byard RW (2016) Unpredictable tensile strength biomechanics may limit thawed cadaver use for simulant research. Aust J Forensic Sci 48:54–58
Zurück zum Zitat Mao H, Shi Z, Wapner KL, Dong W, Yin W, Xu D (2015) Anatomical study for flexor hallucis longus tendon transfer in treatment of Achilles tendinopathy. Surg Radiol Anat 37:639–647PubMed Mao H, Shi Z, Wapner KL, Dong W, Yin W, Xu D (2015) Anatomical study for flexor hallucis longus tendon transfer in treatment of Achilles tendinopathy. Surg Radiol Anat 37:639–647PubMed
Zurück zum Zitat Mezian K, Naňka O (2017) Non-fresh formaldehyde-embalmed cadaver: not an eligible model for ultrasound guided sacroiliac joint injection studies. Med Ultrason 19:457–461PubMed Mezian K, Naňka O (2017) Non-fresh formaldehyde-embalmed cadaver: not an eligible model for ultrasound guided sacroiliac joint injection studies. Med Ultrason 19:457–461PubMed
Zurück zum Zitat Nazarian A, Hermannsson BJ, Muller J, Zurakowski D, Snyder BD (2009) Effects of tissue preservation on murine bone mechanical properties. J Biomech 42:82–86PubMed Nazarian A, Hermannsson BJ, Muller J, Zurakowski D, Snyder BD (2009) Effects of tissue preservation on murine bone mechanical properties. J Biomech 42:82–86PubMed
Zurück zum Zitat Ng BH, Chou SM, Lim BH, Chong A (2005) The changes in the tensile properties of tendons after freeze storage in saline solution. Proc Inst Mech Eng H 219:387–392PubMed Ng BH, Chou SM, Lim BH, Chong A (2005) The changes in the tensile properties of tendons after freeze storage in saline solution. Proc Inst Mech Eng H 219:387–392PubMed
Zurück zum Zitat Nicholson HD, Samalia L, Gould M, Hurst PR, Woodroffe M (2005) A comparison of different embalming fluids on the quality of histological preservation in human cadavers. Eur J Morphol 42:178–184PubMed Nicholson HD, Samalia L, Gould M, Hurst PR, Woodroffe M (2005) A comparison of different embalming fluids on the quality of histological preservation in human cadavers. Eur J Morphol 42:178–184PubMed
Zurück zum Zitat Ocel JJ, Natt N, Tiegs RD, Arora AS (2006) Formal procedural skills training using a fresh–frozen cadaver model: a pilot study. Clin Anat 19:142–146PubMed Ocel JJ, Natt N, Tiegs RD, Arora AS (2006) Formal procedural skills training using a fresh–frozen cadaver model: a pilot study. Clin Anat 19:142–146PubMed
Zurück zum Zitat Ohman C, Dall’Ara E, Baleani M, Van Sint Jan S, Viceconti M (2008) The effects of embalming using a 4% formalin solution on the compressive mechanical properties of human cortical bone. Clin Biomech (Bristol, Avon) 23:1294–1298 Ohman C, Dall’Ara E, Baleani M, Van Sint Jan S, Viceconti M (2008) The effects of embalming using a 4% formalin solution on the compressive mechanical properties of human cortical bone. Clin Biomech (Bristol, Avon) 23:1294–1298
Zurück zum Zitat Ohno K, Yasuda K, Yamamoto N, Kaneda K, Hayashi K (1993) Effects of complete stress-shielding on the mechanical properties and histology of in situ frozen patellar tendon. J Orthop Res 11:592–602PubMed Ohno K, Yasuda K, Yamamoto N, Kaneda K, Hayashi K (1993) Effects of complete stress-shielding on the mechanical properties and histology of in situ frozen patellar tendon. J Orthop Res 11:592–602PubMed
Zurück zum Zitat O’Leary SA, Doyle BJ, McGloughlin TM (2014) The impact of long term freezing on the mechanical properties of porcine aortic tissue. J Mech Behav Biomed Mater 37:165–173PubMed O’Leary SA, Doyle BJ, McGloughlin TM (2014) The impact of long term freezing on the mechanical properties of porcine aortic tissue. J Mech Behav Biomed Mater 37:165–173PubMed
Zurück zum Zitat Plaass C, Abuharbid G, Waizy H, Ochs M, Stukenborg-Colsman C, Schmiedl A (2013) Anatomical variations of the flexor hallucis longus and flexor digitorum longus in the chiasma plantare. Foot Ankle Int 34:1580–1587PubMed Plaass C, Abuharbid G, Waizy H, Ochs M, Stukenborg-Colsman C, Schmiedl A (2013) Anatomical variations of the flexor hallucis longus and flexor digitorum longus in the chiasma plantare. Foot Ankle Int 34:1580–1587PubMed
Zurück zum Zitat Schoeman M, van Schoor A, Suleman F, Louw L, du Toit P (2018) The validity of arterial measurements in a South African embalmed body population. Surg Radiol Anat 40:39–43PubMed Schoeman M, van Schoor A, Suleman F, Louw L, du Toit P (2018) The validity of arterial measurements in a South African embalmed body population. Surg Radiol Anat 40:39–43PubMed
Zurück zum Zitat Shaw JM, Hunter SA, Gayton JC, Boivin GP, Prayson MJ (2012) Repeated freeze–thaw cycles do not alter the biomechanical properties of fibular allograft bone. Clin Orthop Relat Res 470:937–943PubMed Shaw JM, Hunter SA, Gayton JC, Boivin GP, Prayson MJ (2012) Repeated freeze–thaw cycles do not alter the biomechanical properties of fibular allograft bone. Clin Orthop Relat Res 470:937–943PubMed
Zurück zum Zitat Shiwani MH (2010) Fresh frozen cadaver: a model for laparoscopic surgery training. J Coll Phys Surg Pak 20:425–426 Shiwani MH (2010) Fresh frozen cadaver: a model for laparoscopic surgery training. J Coll Phys Surg Pak 20:425–426
Zurück zum Zitat Smith CW, Young IS, Kearney JN (1996) Mechanical properties of tendons: changes with sterilization and preservation. J Biomech Eng 118:56–61PubMed Smith CW, Young IS, Kearney JN (1996) Mechanical properties of tendons: changes with sterilization and preservation. J Biomech Eng 118:56–61PubMed
Zurück zum Zitat Stefan U, Michael B, Werner S (2010) Effects of three different preservation methods on the mechanical properties of human and bovine cortical bone. Bone 47:1048–1053PubMed Stefan U, Michael B, Werner S (2010) Effects of three different preservation methods on the mechanical properties of human and bovine cortical bone. Bone 47:1048–1053PubMed
Zurück zum Zitat Vafek EC, Plate JF, Friedman E, Mannava S, Scott AT, Danelson KA (2018) The effect of strain and age on the mechanical properties of rat Achilles tendon. Muscles Ligaments Tendons J 10:548–553 Vafek EC, Plate JF, Friedman E, Mannava S, Scott AT, Danelson KA (2018) The effect of strain and age on the mechanical properties of rat Achilles tendon. Muscles Ligaments Tendons J 10:548–553
Zurück zum Zitat Venkatasubramanian RT, Grassl RT, Barocas VH, Lafontaine D, Bischof JC (2006) Effects of freezing and cryopreservation on the mechanical properties ofarteries. Ann Biomed Eng 34:823–832PubMed Venkatasubramanian RT, Grassl RT, Barocas VH, Lafontaine D, Bischof JC (2006) Effects of freezing and cryopreservation on the mechanical properties ofarteries. Ann Biomed Eng 34:823–832PubMed
Zurück zum Zitat Verstraete MA, Van der Straeten C, De Lepeleere B, Opsomer GJ, Van Hoof T, Victor J (2015) Impact of drying and thiel embalming on mechanical properties of Achilles tendons. Clin Anat 28:994–1001PubMed Verstraete MA, Van der Straeten C, De Lepeleere B, Opsomer GJ, Van Hoof T, Victor J (2015) Impact of drying and thiel embalming on mechanical properties of Achilles tendons. Clin Anat 28:994–1001PubMed
Zurück zum Zitat Viidik A, Lewin T (1966) Changes in tensile strength characteristics and histology of rabbit ligaments induced by different modes of postmortal storage. Acta Orthop Scand 37:141–155PubMed Viidik A, Lewin T (1966) Changes in tensile strength characteristics and histology of rabbit ligaments induced by different modes of postmortal storage. Acta Orthop Scand 37:141–155PubMed
Zurück zum Zitat Whitehead MC, Savoia MC (2008) Evaluation of methods to reduce formaldehyde levels of cadavers in the dissection laboratory. Clin Anat 21:75–81PubMed Whitehead MC, Savoia MC (2008) Evaluation of methods to reduce formaldehyde levels of cadavers in the dissection laboratory. Clin Anat 21:75–81PubMed
Zurück zum Zitat Wilke HJ, Werner K, Haussler K, Reinehr M, Bockers TM (2011) Thiel-fixation preserves the non-linear load-deformation characteristics of spinal motion segments, but increases their flexibility. J Mech Behav Biomed Mater 4:2133–2137PubMed Wilke HJ, Werner K, Haussler K, Reinehr M, Bockers TM (2011) Thiel-fixation preserves the non-linear load-deformation characteristics of spinal motion segments, but increases their flexibility. J Mech Behav Biomed Mater 4:2133–2137PubMed
Zurück zum Zitat Wolkoff P, Nielsen GD (2010) Non-cancer effects of formaldehyde and relevance for setting an indoor air guideline. Environ Int 36:788–799PubMed Wolkoff P, Nielsen GD (2010) Non-cancer effects of formaldehyde and relevance for setting an indoor air guideline. Environ Int 36:788–799PubMed
Zurück zum Zitat Woo SL, Orlando CA, Camp JF, Akeson WH (1986) Effects of postmortem storage by freezing on ligament tensile behavior. J Biomech 19:399–404PubMed Woo SL, Orlando CA, Camp JF, Akeson WH (1986) Effects of postmortem storage by freezing on ligament tensile behavior. J Biomech 19:399–404PubMed
Metadaten
Titel
Effects of different cadaver preservation methods on muscles and tendons: a morphometric, biomechanical and histological study
verfasst von
Orhan Beger
Meryem İlkay Karagül
Turan Koç
Gülden Kayan
Abdülkadir Cengiz
Şakir Necat Yılmaz
Zeliha Kurtoğlu Olgunus
Publikationsdatum
06.11.2019
Verlag
Springer Singapore
Erschienen in
Anatomical Science International / Ausgabe 2/2020
Print ISSN: 1447-6959
Elektronische ISSN: 1447-073X
DOI
https://doi.org/10.1007/s12565-019-00508-z

Kompaktes Leitlinien-Wissen Innere Medizin (Link öffnet in neuem Fenster)

Mit medbee Pocketcards schnell und sicher entscheiden.
Leitlinien-Wissen kostenlos und immer griffbereit auf ihrem Desktop, Handy oder Tablet.

Neu im Fachgebiet Innere Medizin

Studie zur HIFU bei Prostatakrebs lässt viele Fragen offen

Führt eine HIFU-Ablation beim Prostatakarzinom im Vergleich mit einer radikalen Prostatektomie zu ähnlichen onkologischen, aber besseren funktionalen Ergebnissen? Interimsdaten der französischen HIFI-Studie sind uneindeutig. In einem Kommentar zur Studie werden zumindest drei allgemeine Erkenntnisse herausgearbeitet.

Leitlinienkonformes Management thermischer Verletzungen

Thermische Verletzungen gehören zu den schwerwiegendsten Traumen und hinterlassen oft langfristige körperliche und psychische Spuren. Die aktuelle S2k-Leitlinie „Behandlung thermischer Verletzungen im Kindesalter (Verbrennung, Verbrühung)“ bietet eine strukturierte Übersicht über das empfohlene Vorgehen.

Verschlechtert frühe Hyperoxie nach Reanimation die Prognose?

Kommt es sehr früh nach einer kardiopulmonalen Reanimation zu einem Zustand der Hyperoxie, ist dies bei Patienten nach einem Herzstillstand mit schlechteren funktionellen Ergebnissen assoziiert. Das zeigt eine Sekundäranalyse der TTM-2-Studie.

Infektanfälligkeit in früher Kindheit: eine bleibende Last?

Wenn Kinder in den ersten Lebensjahren immer wieder Infekte durchmachen, lässt dies Schlüsse auf die Infektneigung in der weiteren Kindheit zu.

EKG Essentials: EKG befunden mit System (Link öffnet in neuem Fenster)

In diesem CME-Kurs können Sie Ihr Wissen zur EKG-Befundung anhand von zwölf Video-Tutorials auffrischen und 10 CME-Punkte sammeln.
Praxisnah, relevant und mit vielen Tipps & Tricks vom Profi.

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.