02.08.2016 | Original Article | Ausgabe 9/2016

Annals of Nuclear Medicine 9/2016

Effects of left ventricular size on the accuracy of diastolic parameters derived from myocardial perfusion SPECT: comparison with tissue Doppler echocardiography

Zeitschrift:
Annals of Nuclear Medicine > Ausgabe 9/2016
Autoren:
Satoshi Kurisu, Yoji Sumimoto, Hiroki Ikenaga, Noriaki Watanabe, Ken Ishibashi, Yoshihiro Dohi, Takayuki Hidaka, Yukihiro Fukuda, Yasuki Kihara

Abstract

Background

Impaired left ventricular (LV) diastolic function is a sensitive and early sign of myocardial ischemia. We evaluated the effects of LV size on the accuracy of diastolic parameters derived from SPECT.

Methods

The study population consisted of 151 patients with known or suspected coronary artery disease who underwent both SPECT and transthoracic echocardiography. Peak filling rate (PFR), one-third mean filling rate (1/3 MFR) and the ratio of time to PFR to the RR interval (TPFR/RR) were calculated by quantitative gated SPECT. Peak early mitral annular velocity (e′) was used as the reference standard of LV diastolic function.

Results

There were 43 patients with end-systolic volume (ESV) of ≤10 ml, 43 patients with ESV of 11–20 ml and 65 patients with ESV of >20 ml. There were significant differences in PFR (p < 0.001), 1/3 MFR (p < 0.001) or TPFR/RR (p = 0.01) among the 3 groups. These diastolic parameters were increased with decreased LV size. In overall patients, PFR (r = 0.24, p = 0.003) and 1/3 MFR (r = 0.31, p < 0.001) were positively, and TPFR/RR (r = −0.23, p = 0.004) was inversely correlated with e′. Multivariate linear regression analyses showed that male gender (β = −0.14, p = 0.07; β = −0.16, p = 0.04), ESV (β = −0.63, p < 0.001; β = −0.45, p < 0.001) and e′ (β = 0.36, p < 0.001; β = 0.40, p < 0.001) were significant factors associated with PFR or 1/3 MFR. Multivariate linear regression analysis also showed that ESV (β = −0.17, p = 0.03) and e′ (β = −0.21, p = 0.01) were significant factors associated with TPFR/RR.

Conclusions

Our data suggest that PFR, 1/3 MFR and TPFR/RR derived from SPECT are correlated with e′ as the reference standard of LV diastolic function, but are overestimated in small-sized heart. LV size should be taken into consideration when interpreting these diastolic parameters.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Jetzt e.Med zum Sonderpreis bestellen!

Sichern Sie sich jetzt Ihr e.Med-Abo und sparen Sie 50 %!

Weitere Produktempfehlungen anzeigen
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 9/2016

Annals of Nuclear Medicine 9/2016 Zur Ausgabe
  1. Sie können e.Med Radiologie 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

  2. Das kostenlose Testabonnement läuft nach 14 Tagen automatisch und formlos aus. Dieses Abonnement kann nur einmal getestet werden.