The aim of this triple-blind randomized clinical trial was to evaluate the efficacy and safety of diode laser during circumvestibular incisions for Le Fort I osteotomy in orthognathic surgeries in comparison with conventional techniques using electrocautery and scalpel. Patients were randomly allocated to one of three groups based on the technique employed to perform incisions: diode laser, electrocautery, and scalpel. The parameters used to evaluate the efficacy and safety of diode laser were incision velocity, duration of surgery, bleeding rate, alterations in postoperative functions, pain, edema, wound clinical healing, and infection. Thirty patients were enrolled in the study (10 per group). Regarding bleeding, the incisions performed with diode laser promoted a lower bleeding rate compared with scalpel and electrocautery (p = 0.00). The diode surgical laser was effective during the incision procedure, but required a longer time to perform the incisions compared with the other techniques evaluated (p < 0.05). No statistically significant difference was detected between groups regarding total surgical time or other safety parameters (p > 0.05). Thus, diode laser proved to be effective and safer during circumvestibular incisions for Le Fort I osteotomy than conventional devices.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
3.
Zurück zum Zitat Proffit W, White R (1990) Who needs surgical–orthodontic treatment? Int J Adult Orthod Orthognath Surg 5:81–89 Proffit W, White R (1990) Who needs surgical–orthodontic treatment? Int J Adult Orthod Orthognath Surg 5:81–89
12.
Zurück zum Zitat Nitta N, Fukami T, Nozaki K (2011) Electrocautery skin incision for neurosurgery procedures--technical note. Neurol Med Chir (Tokyo) 51:88–91CrossRef Nitta N, Fukami T, Nozaki K (2011) Electrocautery skin incision for neurosurgery procedures--technical note. Neurol Med Chir (Tokyo) 51:88–91CrossRef
23.
Zurück zum Zitat Moss JP, Linney AD, Lowey MN (1995) The use of three-dimensional techniques in facial esthetics. Semin Orthod 1:94–104CrossRef Moss JP, Linney AD, Lowey MN (1995) The use of three-dimensional techniques in facial esthetics. Semin Orthod 1:94–104CrossRef
Metadaten
Titel
Efficacy and safety of diode laser during circumvestibular incision for Le Fort I osteotomy in orthognathic surgery: a triple-blind randomized clinical trial
verfasst von
Filipe Jaeger
Gustavo Marques de Oliveira Chiavaioli
Guilherme Lacerda de Toledo
Belini Freire-Maia
Marcio Bruno Figueiredo Amaral
Mauro Henrique Nogueira Guimarães de Abreu
José Alcides Almeida de Arruda
Ricardo Alves Mesquita
Publikationsdatum
04.07.2019
Verlag
Springer London
Erschienen in
Lasers in Medical Science / Ausgabe 2/2020
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-019-02832-2

Weitere Artikel der Ausgabe 2/2020

Lasers in Medical Science 2/2020 Zur Ausgabe