Skip to main content
Erschienen in: International Ophthalmology 3/2019

02.02.2018 | Original Paper

Efficacy and safety of pop-titrated versus fixed-energy trans-scleral diode laser cyclophotocoagulation for refractory glaucoma

verfasst von: Marcelo O. Stevenson-Fernandez, Alejandro Rodriguez-Garcia, Angelina Espino-Barros Palau, Pedro Mario Gonzalez-Madrigal

Erschienen in: International Ophthalmology | Ausgabe 3/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To compare the efficacy and safety of pop-titrated versus fixed-energy diode laser trans-scleral cyclophotocoagulation (DLTSC) for refractory glaucoma.

Methods

This is a prospective, interventional, longitudinal, and comparative case–control study. Patients with refractory glaucoma treated with pop-titrated DLTSC were compared to a fixed-energy DLTSC control group. Variables analyzed included: age, gender, diagnosis, pre- and post-treatment intraocular pressure (IOP). Success rate, anti-glaucoma medications reduction, and complications were analyzed at day 90 post-treatment. Primary success criterion consisted of eyes with a postoperative IOP ≤ 22 mmHg or a 30% reduction of pre-treatment IOP and managed with topical anti-glaucoma medications only.

Results

A total of 68 eyes from 67 patients were included for analysis: 30 in the pop-titrated group and 38 in the fixed-energy group. Therapeutic success was achieved in 56–72% of the pop-titrated group versus 47–52% in the fixed-energy group considering the 3 different criteria analyzed (p = 0.23–0.4). There was a 22% (from 4.1 to 3.2 drugs) reduction of anti-glaucoma medications in the pop-titrated group, compared to 32% (from 3.5 to 2.4 drugs) in the fixed-energy group (p = 0.42). Five eyes (13.1%) developed hypotony, all of which belonged to the fixed-energy group (p = 0.048).

Conclusions

Pop-titrated DLTSC represents an effective and safe option for the management of refractory glaucoma. We found no statistically significant difference in success rates among both groups. However, there was a significantly higher risk of hypotony in eyes treated with the fixed-energy protocol.
Literatur
1.
Zurück zum Zitat Rodríguez-García A, González-González LA, Alvarez-Guzmán JC (2016) Trans-scleral diode laser cyclophotocoagulation for refractory glaucoma after high-risk penetrating keratoplasty. Int Ophthalmol 36:373–383CrossRefPubMed Rodríguez-García A, González-González LA, Alvarez-Guzmán JC (2016) Trans-scleral diode laser cyclophotocoagulation for refractory glaucoma after high-risk penetrating keratoplasty. Int Ophthalmol 36:373–383CrossRefPubMed
2.
Zurück zum Zitat Egbert PR, Fiadoyor S, Budenz DL, Dadzie P, Byrd S (2001) Diode laser trans-scleral cyclophotocoagulation as a primary surgical treatment for primary open-angle glaucoma. Arch Ophthalmol 119:345–350CrossRefPubMed Egbert PR, Fiadoyor S, Budenz DL, Dadzie P, Byrd S (2001) Diode laser trans-scleral cyclophotocoagulation as a primary surgical treatment for primary open-angle glaucoma. Arch Ophthalmol 119:345–350CrossRefPubMed
3.
Zurück zum Zitat Ghosh S, Manvikar S, Ray-Chaudhuri N, Birch M (2013) Efficacy of trans-scleral diode laser cyclophotocoagulation in patients with good visual acuity. Eur J Ophthalmol 24:375–381CrossRefPubMed Ghosh S, Manvikar S, Ray-Chaudhuri N, Birch M (2013) Efficacy of trans-scleral diode laser cyclophotocoagulation in patients with good visual acuity. Eur J Ophthalmol 24:375–381CrossRefPubMed
4.
Zurück zum Zitat Kraus CL, Tychsen L, Lueder GT, Culican SM (2014) Comparison of the effectiveness and safety of trans-scleral cyclophotocoagulation and endoscopic cyclophotocoagulation in pediatric glaucoma. J Pediatr Ophthalmol Strabismus 51:120–127CrossRefPubMed Kraus CL, Tychsen L, Lueder GT, Culican SM (2014) Comparison of the effectiveness and safety of trans-scleral cyclophotocoagulation and endoscopic cyclophotocoagulation in pediatric glaucoma. J Pediatr Ophthalmol Strabismus 51:120–127CrossRefPubMed
5.
Zurück zum Zitat Frezzotti P, Mittica V, Martone G, Motolese I, Lomurno L, Peruzzi S, Motolese E (2010) Long-term follow-up of diode laser trans-scleral cyclophotocoagulation in the treatment of refractory glaucoma. Acta Ophthalmol 88:150–155CrossRefPubMed Frezzotti P, Mittica V, Martone G, Motolese I, Lomurno L, Peruzzi S, Motolese E (2010) Long-term follow-up of diode laser trans-scleral cyclophotocoagulation in the treatment of refractory glaucoma. Acta Ophthalmol 88:150–155CrossRefPubMed
6.
Zurück zum Zitat Yildirim N, Yalvac IS, Sahin A, Ozer A, Bozca T (2009) A comparative study between diode laser cyclophotocoagulation and the Ahmed glaucoma valve implant in neovascular glaucoma: a long term follow-up. J Glaucoma 18:192–196CrossRefPubMed Yildirim N, Yalvac IS, Sahin A, Ozer A, Bozca T (2009) A comparative study between diode laser cyclophotocoagulation and the Ahmed glaucoma valve implant in neovascular glaucoma: a long term follow-up. J Glaucoma 18:192–196CrossRefPubMed
7.
Zurück zum Zitat Gupta V, Agarwal HC (2000) Contact trans-scleral diode laser cyclophotocoagulation treatment for refractory glaucomas in the Indian population. Indian J Ophthalmol 48:295–300PubMed Gupta V, Agarwal HC (2000) Contact trans-scleral diode laser cyclophotocoagulation treatment for refractory glaucomas in the Indian population. Indian J Ophthalmol 48:295–300PubMed
8.
Zurück zum Zitat Lai JS, Tham CC, Chan JC, Lam DS (2005) Diode laser trans-scleral cyclophotocoagulation as primary surgical treatment for medically uncontrolled chronic angle closure glaucoma: long-term clinical outcomes. J Glaucoma 14:114–119CrossRefPubMed Lai JS, Tham CC, Chan JC, Lam DS (2005) Diode laser trans-scleral cyclophotocoagulation as primary surgical treatment for medically uncontrolled chronic angle closure glaucoma: long-term clinical outcomes. J Glaucoma 14:114–119CrossRefPubMed
9.
Zurück zum Zitat Hauber FA, Scherer WJ (2002) Influence of total energy delivery on success rate after contact diode laser trans-scleral cyclophotocoagulation: a retrospective case review and meta-analysis. J Glaucoma 11:329–333CrossRefPubMed Hauber FA, Scherer WJ (2002) Influence of total energy delivery on success rate after contact diode laser trans-scleral cyclophotocoagulation: a retrospective case review and meta-analysis. J Glaucoma 11:329–333CrossRefPubMed
10.
Zurück zum Zitat Ishida K (2013) Update on results and complications of cyclophotocoagulation. Curr Opin Ophthalmol 24:102–110CrossRefPubMed Ishida K (2013) Update on results and complications of cyclophotocoagulation. Curr Opin Ophthalmol 24:102–110CrossRefPubMed
11.
Zurück zum Zitat Schubert HD (1993) The Influence of exposure duration in trans-scleral Nd:YAG laser cyclophotocoagulation. Am J Opthalmol 115:684–685CrossRef Schubert HD (1993) The Influence of exposure duration in trans-scleral Nd:YAG laser cyclophotocoagulation. Am J Opthalmol 115:684–685CrossRef
12.
Zurück zum Zitat Iliev ME, Gerber S (2007) Long-term outcome of trans-scleral diode laser cyclophotocoagulation in refractory glaucoma. Br J Ophthalmol 91:1631–1635CrossRefPubMedPubMedCentral Iliev ME, Gerber S (2007) Long-term outcome of trans-scleral diode laser cyclophotocoagulation in refractory glaucoma. Br J Ophthalmol 91:1631–1635CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Murphy CC, Burnett CA, Spry PG, Broadway DC, Diamond JP (2003) A two centre study of the dose-response relation for trans-scleral diode laser cyclophotocoagulation in refractory glaucoma. Br J Ophthalmol 87:1252–1257CrossRefPubMedPubMedCentral Murphy CC, Burnett CA, Spry PG, Broadway DC, Diamond JP (2003) A two centre study of the dose-response relation for trans-scleral diode laser cyclophotocoagulation in refractory glaucoma. Br J Ophthalmol 87:1252–1257CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Espino-Barros-Palau A, Rodríguez-García A (2012) Trans-scleral diode laser cyclophotocoagulation in the management of diabetic neovascular glaucoma. Rev Mex Oftalmol 86:12–19 Espino-Barros-Palau A, Rodríguez-García A (2012) Trans-scleral diode laser cyclophotocoagulation in the management of diabetic neovascular glaucoma. Rev Mex Oftalmol 86:12–19
15.
Zurück zum Zitat Rebolleda G, Muñoz F, Murube J (1999) Audible pops during cyclodiode procedures. J Glaucoma 8:177–183CrossRefPubMed Rebolleda G, Muñoz F, Murube J (1999) Audible pops during cyclodiode procedures. J Glaucoma 8:177–183CrossRefPubMed
16.
Zurück zum Zitat Kaushik S, Pandav SS, Jain R, Bansal S, Gupta A (2008) Lower energy levels adequate of effective trans-scleral diode laser cyclophotocoagulation in Asian eyes with refractory glaucoma. Eye (London) 22:398–405CrossRef Kaushik S, Pandav SS, Jain R, Bansal S, Gupta A (2008) Lower energy levels adequate of effective trans-scleral diode laser cyclophotocoagulation in Asian eyes with refractory glaucoma. Eye (London) 22:398–405CrossRef
17.
Zurück zum Zitat Rotchford AP, Jayasawal R, Madhusudhan S, Ho S, King AJ, Vernon SA (2010) Trans-scleral diode laser cycloablation in patients with good vision. Br J Ophthalmol 94:1180–1183CrossRefPubMed Rotchford AP, Jayasawal R, Madhusudhan S, Ho S, King AJ, Vernon SA (2010) Trans-scleral diode laser cycloablation in patients with good vision. Br J Ophthalmol 94:1180–1183CrossRefPubMed
18.
Zurück zum Zitat Sivagnanavel V, Ortiz-Hurtado A, Williamson TH (2005) Diode laser trans-scleral cyclophotocoagulation in the management of glaucoma in patients with long-term intravitreal silicone oil. Eye (London) 19:253–257CrossRef Sivagnanavel V, Ortiz-Hurtado A, Williamson TH (2005) Diode laser trans-scleral cyclophotocoagulation in the management of glaucoma in patients with long-term intravitreal silicone oil. Eye (London) 19:253–257CrossRef
19.
Zurück zum Zitat Gangwani R, Liu DT, Congdon N, Lam PT, Lee VY, Yuen NS, Lam DS (2011) Effectiveness of diode laser trans-scleral cyclophotocoagulation in patients following silicone oil-induced ocular hypertension in Chinese eyes. Indian J Ophthalmol 59:64–66CrossRefPubMedPubMedCentral Gangwani R, Liu DT, Congdon N, Lam PT, Lee VY, Yuen NS, Lam DS (2011) Effectiveness of diode laser trans-scleral cyclophotocoagulation in patients following silicone oil-induced ocular hypertension in Chinese eyes. Indian J Ophthalmol 59:64–66CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Bloom PA, Clement CI, King A, Noureddin B, Sharma K, Hitchings RA, Khaw PT (2013) A comparison between tube surgery, ND:YAG laser and diode laser cyclophotocoagulation in the management of refractory glaucoma. Biomed Res Int. https://doi.org/10.1155/2013/371951 Bloom PA, Clement CI, King A, Noureddin B, Sharma K, Hitchings RA, Khaw PT (2013) A comparison between tube surgery, ND:YAG laser and diode laser cyclophotocoagulation in the management of refractory glaucoma. Biomed Res Int. https://​doi.​org/​10.​1155/​2013/​371951
Metadaten
Titel
Efficacy and safety of pop-titrated versus fixed-energy trans-scleral diode laser cyclophotocoagulation for refractory glaucoma
verfasst von
Marcelo O. Stevenson-Fernandez
Alejandro Rodriguez-Garcia
Angelina Espino-Barros Palau
Pedro Mario Gonzalez-Madrigal
Publikationsdatum
02.02.2018
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 3/2019
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-018-0834-1

Weitere Artikel der Ausgabe 3/2019

International Ophthalmology 3/2019 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.