Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 1/2012

01.01.2012 | Knee

Efficacy of immunohistological methods in detecting functionally viable mechanoreceptors in the remnant stumps of injured anterior cruciate ligaments and its clinical importance

verfasst von: Kamal Bali, Mandeep S. Dhillon, R. K. Vasistha, Nandita Kakkar, Rishi Chana, Sharad Prabhakar

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 1/2012

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Various histological and immunological methods have been used to detect the mechanoreceptors and nerve fibers on the intact ACLs as well as on the remnant stumps. However, some of these methods lack standardization, and the variable thickness of slices used often leads to misinterpretation. The study was based on the hypothesis that immunohistological methods are easier and more reliable means to demonstrate mechanoreceptors in the remnant ACL stumps as compared with the conventional methods. We also attempted to validate the methodology of immunohistology as a means of characterizing functional mechanoreceptors in the residual stump of an injured ACL.

Methods

The remnants of the ruptured ACL in 95 patients were harvested during arthroscopic ACL reconstruction and evaluated immunohistologically using hematoxylin and eosin (H&E), and monoclonal antibodies to S-100 and NFP. Multiple sections from each specimen were serially examined by two histologists.

Results

The positivity of monoclonal antibody against NFP showed a statistically significant relationship with the presence of morphologically normal mechanoreceptors, whereas the positivity of monoclonal antibody against S-100 showed a statistically significant relationship with the presence of free nerve ending in the residual stump of an injured ACL.

Conclusions

Immunological methods are more reliable and easier to use as compared with the conventional methods of histological staining for identifying remnant stumps likely to be of some proprioceptive benefit after an ACL injury. Such an identification might help us preserve certain remnant stumps during ACL reconstruction which might in turn improve the postoperative functional outcomes.
Literatur
1.
Zurück zum Zitat Adachi N, Ochi M, Uchio Y, Iwasa J, Ryoke K, Kuriwaka M (2002) Mechanoreceptors in the anterior cruciate ligament contribute to the joint position sense. Acta Orthop Scand 73:330–334PubMedCrossRef Adachi N, Ochi M, Uchio Y, Iwasa J, Ryoke K, Kuriwaka M (2002) Mechanoreceptors in the anterior cruciate ligament contribute to the joint position sense. Acta Orthop Scand 73:330–334PubMedCrossRef
2.
Zurück zum Zitat Adachi N, Ochi M, Uchio Y, Sumen Y (2000) Anterior cruciate ligament augmentation under arthroscopy. A minimum 2-year follow-up in 40 patients. Arch Orthop Trauma Surg 120:128–133PubMedCrossRef Adachi N, Ochi M, Uchio Y, Sumen Y (2000) Anterior cruciate ligament augmentation under arthroscopy. A minimum 2-year follow-up in 40 patients. Arch Orthop Trauma Surg 120:128–133PubMedCrossRef
3.
Zurück zum Zitat Barrett DS (1991) Proprioception and function after anterior cruciate ligament reconstruction. J Bone Joint Surg Br 73:833–837PubMed Barrett DS (1991) Proprioception and function after anterior cruciate ligament reconstruction. J Bone Joint Surg Br 73:833–837PubMed
4.
Zurück zum Zitat Biedert RM, Stauffer E, Friederich NF (1992) Occurrence of free nerve endings in the soft tissue of the knee joint. A histologic investigation. Am J Sports Med 20:430–433PubMedCrossRef Biedert RM, Stauffer E, Friederich NF (1992) Occurrence of free nerve endings in the soft tissue of the knee joint. A histologic investigation. Am J Sports Med 20:430–433PubMedCrossRef
5.
Zurück zum Zitat Borsa PA, Lephart SM, Irrgang JJ, Safran MR, Fu FH (1997) The effects of joint position and direction of joint motion on proprioceptive sensibility in anterior cruciate ligament—deficient athletes. Am J Sports Med 25:336–340PubMedCrossRef Borsa PA, Lephart SM, Irrgang JJ, Safran MR, Fu FH (1997) The effects of joint position and direction of joint motion on proprioceptive sensibility in anterior cruciate ligament—deficient athletes. Am J Sports Med 25:336–340PubMedCrossRef
6.
Zurück zum Zitat Del Valle ME, Harwin SF, Maestro A et al (1998) Immunohistochemical analysis of mechanoreceptors in the human posterior cruciate ligament: a demonstration of its proprioceptive role and clinical relevance. J Arthroplasty 13:916–922PubMedCrossRef Del Valle ME, Harwin SF, Maestro A et al (1998) Immunohistochemical analysis of mechanoreceptors in the human posterior cruciate ligament: a demonstration of its proprioceptive role and clinical relevance. J Arthroplasty 13:916–922PubMedCrossRef
7.
Zurück zum Zitat Denti M, Monteleone M, Berardi A, Panni AS (1994) Anterior cruciate ligament mechanoreceptors. Clin Orthop Relat Res 308:29–32PubMed Denti M, Monteleone M, Berardi A, Panni AS (1994) Anterior cruciate ligament mechanoreceptors. Clin Orthop Relat Res 308:29–32PubMed
8.
Zurück zum Zitat Dhillon MS, Bali K, Vasistha RK (2010) Immunohistological evaluation of the proprioceptive potential of the residual stump of an injured anterior cruciate ligament. Int Orthop 34:737–741PubMedCrossRef Dhillon MS, Bali K, Vasistha RK (2010) Immunohistological evaluation of the proprioceptive potential of the residual stump of an injured anterior cruciate ligament. Int Orthop 34:737–741PubMedCrossRef
9.
Zurück zum Zitat Georgoulis AD, Pappa L, Moebius U et al (2001) The presence of proprioceptive mechanoreceptors in the remnants of ruptured ACL as possible source of reinnervation of ACL autograft. Knee Surg Sports Traumatol Arthrosc 9:364–368PubMedCrossRef Georgoulis AD, Pappa L, Moebius U et al (2001) The presence of proprioceptive mechanoreceptors in the remnants of ruptured ACL as possible source of reinnervation of ACL autograft. Knee Surg Sports Traumatol Arthrosc 9:364–368PubMedCrossRef
10.
Zurück zum Zitat Halata Z, Rettig T, Schulze W (1985) The ultrastructure of sensory nerve endings in human knee joint capsule. Anat. Embryol(Berl) 172:265–275CrossRef Halata Z, Rettig T, Schulze W (1985) The ultrastructure of sensory nerve endings in human knee joint capsule. Anat. Embryol(Berl) 172:265–275CrossRef
11.
Zurück zum Zitat Hogervorst T, Brand RA (1998) Mechanoreceptors in joint function. J Bone Joint Surg Am 80:1365–1378PubMed Hogervorst T, Brand RA (1998) Mechanoreceptors in joint function. J Bone Joint Surg Am 80:1365–1378PubMed
12.
Zurück zum Zitat Johansson H, Sjolander P, Sojka P (1991) A sensory role for the cruciate ligaments. Clin Orthop Relat Res 268:161–178PubMed Johansson H, Sjolander P, Sojka P (1991) A sensory role for the cruciate ligaments. Clin Orthop Relat Res 268:161–178PubMed
13.
Zurück zum Zitat Johansson H, Sjolander P, Sojka P (1991) Receptors in knee joint and their role in biomechanics of joint. Crit Rev Biomed Eng 18:341–368PubMed Johansson H, Sjolander P, Sojka P (1991) Receptors in knee joint and their role in biomechanics of joint. Crit Rev Biomed Eng 18:341–368PubMed
14.
Zurück zum Zitat Kennedy JC, Alexander IJ, Hayes KC (1982) Nerve supply of the human knee and its functional importance. Am J Sports Med 10:329–335PubMedCrossRef Kennedy JC, Alexander IJ, Hayes KC (1982) Nerve supply of the human knee and its functional importance. Am J Sports Med 10:329–335PubMedCrossRef
15.
Zurück zum Zitat Krauspe R, Schmidt M, Schaible HG (1992) Sensory innervation of the anterior cruciate ligament. An electrophysiological study of the response properties of single identified mechanoreceptors in the cat. J Bone Joint Surg Am 74:390–397PubMed Krauspe R, Schmidt M, Schaible HG (1992) Sensory innervation of the anterior cruciate ligament. An electrophysiological study of the response properties of single identified mechanoreceptors in the cat. J Bone Joint Surg Am 74:390–397PubMed
16.
Zurück zum Zitat Krauspe R, Schmitz F, Zöller G, Drenckhahn D (1995) Distribution of neurofilament-positive nerve fibres and sensory endings in the human anterior cruciate ligament. Arch Orthop Trauma Surg 114:194–198PubMedCrossRef Krauspe R, Schmitz F, Zöller G, Drenckhahn D (1995) Distribution of neurofilament-positive nerve fibres and sensory endings in the human anterior cruciate ligament. Arch Orthop Trauma Surg 114:194–198PubMedCrossRef
17.
Zurück zum Zitat Lee BI, Kwon SW, Kim JB et al (2008) Comparison of clinical results according to amount of preserved remnant in arthroscopic anterior cruciate ligament reconstruction using quadrupled hamstring graft. Arthroscopy 24:560–568PubMedCrossRef Lee BI, Kwon SW, Kim JB et al (2008) Comparison of clinical results according to amount of preserved remnant in arthroscopic anterior cruciate ligament reconstruction using quadrupled hamstring graft. Arthroscopy 24:560–568PubMedCrossRef
18.
Zurück zum Zitat Lee BI, Min KD, Choi HS et al (2009) Immunohistochemical study of mechanoreceptors in the tibial remnant of the ruptured anterior cruciate ligament in human knees. Knee Surg Sports Traumatol Arthrosc 17:1095–1101PubMedCrossRef Lee BI, Min KD, Choi HS et al (2009) Immunohistochemical study of mechanoreceptors in the tibial remnant of the ruptured anterior cruciate ligament in human knees. Knee Surg Sports Traumatol Arthrosc 17:1095–1101PubMedCrossRef
19.
Zurück zum Zitat Ochi M, Adachi N, Deie M, Kanaya A (2006) Anterior cruciate ligament augmentation procedure with a 1-incision technique: anteromedial bundle or posterolateral bundle reconstruction. Arthroscopy 22:463.e1–5 Ochi M, Adachi N, Deie M, Kanaya A (2006) Anterior cruciate ligament augmentation procedure with a 1-incision technique: anteromedial bundle or posterolateral bundle reconstruction. Arthroscopy 22:463.e1–5
20.
Zurück zum Zitat Schultz RA, Miller DC, Kerr CS, Micheli L (1984) Mechanoreceptors in human cruciate ligaments. A histological study. J Bone Joint Surg Am 66:1072–1076PubMed Schultz RA, Miller DC, Kerr CS, Micheli L (1984) Mechanoreceptors in human cruciate ligaments. A histological study. J Bone Joint Surg Am 66:1072–1076PubMed
21.
Zurück zum Zitat Schutte MJ, Dabezies EJ, Zimny ML, Happel LT (1987) Neural anatomy of the human anterior cruciate ligament. J Bone Joint Surg Am 69:243–247PubMed Schutte MJ, Dabezies EJ, Zimny ML, Happel LT (1987) Neural anatomy of the human anterior cruciate ligament. J Bone Joint Surg Am 69:243–247PubMed
22.
Zurück zum Zitat Shimizu T, Takahashi T, Wada Y et al (1999) Regeneration process of mechanoreceptors in the reconstructed anterior cruciate ligament. Arch Orthop Trauma Surg 119:405–409PubMedCrossRef Shimizu T, Takahashi T, Wada Y et al (1999) Regeneration process of mechanoreceptors in the reconstructed anterior cruciate ligament. Arch Orthop Trauma Surg 119:405–409PubMedCrossRef
23.
Zurück zum Zitat Zimny ML, Schutte M, Dabezies E (1986) Mechanoreceptors in the human anterior cruciate ligament. Anat Rec 214:204–209PubMedCrossRef Zimny ML, Schutte M, Dabezies E (1986) Mechanoreceptors in the human anterior cruciate ligament. Anat Rec 214:204–209PubMedCrossRef
Metadaten
Titel
Efficacy of immunohistological methods in detecting functionally viable mechanoreceptors in the remnant stumps of injured anterior cruciate ligaments and its clinical importance
verfasst von
Kamal Bali
Mandeep S. Dhillon
R. K. Vasistha
Nandita Kakkar
Rishi Chana
Sharad Prabhakar
Publikationsdatum
01.01.2012
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 1/2012
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-011-1526-9

Weitere Artikel der Ausgabe 1/2012

Knee Surgery, Sports Traumatology, Arthroscopy 1/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.