Efficacy of ultrasound-guided axillary/subclavian venous approaches for pacemaker and defibrillator lead implantation: a randomized study

verfasst von: Mattia Liccardo, Pasquale Nocerino, Salzano Gaia, Carmine Ciardiello

Erschienen in: Journal of Interventional Cardiac Electrophysiology | Ausgabe 2/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Subclavian access is a reliable technique for lead insertion in pacemaker and defibrillator (ICD) implantation, but it is often accompanied by complications. The aim of this study was to compare the efficacy of the ultrasound-guided axillary approach to the subclavian method.

Methods

This randomized comparative study was performed on 174 patients: as a first attempt, 116 patients underwent the ultrasound-guided axillary access and 58 patients underwent the subclavian approach. A total of 364 leads were placed. Operators were trained in ultrasound-guided vein access technique.

Results

Axillary access was successful in 69% of patients (32/46), in the training phase and, as a first attempt, in 91.4% of patients (106/116), in the randomized phase. When axillary approach failed, we performed the following: subclavian access in 5.2% of patients (6/116), cephalic approach in 2.6% of patients (3/116), surgical method in 0.9% of patients (1/116). The subclavian technique was effective, as a first attempt, in 55 patients (94.8%). When the subclavian access failed, the ultrasound axillary approach successfully performed in all three cases. During a mean follow-up of 18 ± 6 months, the number of lead complications was similar in the subclavian group compared to the axillary group (p = 0.664).

Conclusions

As first attempt, ultrasound-guided axillary method showed similarly high-success rate than subclavian approach and well performed when the first attempt in subclavian group failed. Axillary access can be considered a safe and effective alternative technique to the conventional subclavian method for device implantation.
Literatur
3.
Zurück zum Zitat Chauhan A, Grace AA, Newell SA, Stone DL, Shapiro LM, Schofield PM, et al. Early complications after dual chamber versus single chamber pacemaker implantation. Pacing Clin Electrophysiol. 1994;17(Pt. II):2012–3.CrossRefPubMed Chauhan A, Grace AA, Newell SA, Stone DL, Shapiro LM, Schofield PM, et al. Early complications after dual chamber versus single chamber pacemaker implantation. Pacing Clin Electrophysiol. 1994;17(Pt. II):2012–3.CrossRefPubMed
10.
Zurück zum Zitat Calkins H, Ramza BM, Brinker J, Atiga W, Donahue K, Nsah E, et al. Prospective randomized comparison of the safety and effectiveness of placement of endocardial pacemaker and defibrillator leads using the extrathoracic subclavian vein guided by contrast venography versus the cephalic approach. Pacing Clin Electrophysiol. 2001;24(4):456–64. https://doi.org/10.1046/j.1460-9592.2001.00456.x.CrossRefPubMed Calkins H, Ramza BM, Brinker J, Atiga W, Donahue K, Nsah E, et al. Prospective randomized comparison of the safety and effectiveness of placement of endocardial pacemaker and defibrillator leads using the extrathoracic subclavian vein guided by contrast venography versus the cephalic approach. Pacing Clin Electrophysiol. 2001;24(4):456–64. https://​doi.​org/​10.​1046/​j.​1460-9592.​2001.​00456.​x.CrossRefPubMed
13.
Zurück zum Zitat Sommerkamp SK, Romaniuk VM, Witting MD, Ford DR, Allison MG, Euerle BD. A Comparison of longitudinal and transverse approaches to ultrasound-guided axillary vein cannulation. Am J Emerg Med. 2013;3:478–81.CrossRef Sommerkamp SK, Romaniuk VM, Witting MD, Ford DR, Allison MG, Euerle BD. A Comparison of longitudinal and transverse approaches to ultrasound-guided axillary vein cannulation. Am J Emerg Med. 2013;3:478–81.CrossRef
15.
Zurück zum Zitat Yaminisharif A, Soofizadeh N, Shafiee A, Kazemisaeid A, Jalali A, Vasheghani-Farahani A. Generator and lead-related complications of implantable cardioverter defibrillators. Int Cardiovasc Res J. 2014;8(2):66–70.PubMedPubMedCentral Yaminisharif A, Soofizadeh N, Shafiee A, Kazemisaeid A, Jalali A, Vasheghani-Farahani A. Generator and lead-related complications of implantable cardioverter defibrillators. Int Cardiovasc Res J. 2014;8(2):66–70.PubMedPubMedCentral
26.
Zurück zum Zitat Franco E, Muñoz DR, Matìa R, Hernandez-Madrid A, Carbonell San Román A, Sánchez I, et al. Wireless ultrasound-guided axillary vein cannulation for the implantation of cardiovascular implantable electric devices. J Cardiovasc Electrophysiol. 2016;27(4):482–7. https://doi.org/10.1111/jce.12917.CrossRefPubMed Franco E, Muñoz DR, Matìa R, Hernandez-Madrid A, Carbonell San Román A, Sánchez I, et al. Wireless ultrasound-guided axillary vein cannulation for the implantation of cardiovascular implantable electric devices. J Cardiovasc Electrophysiol. 2016;27(4):482–7. https://​doi.​org/​10.​1111/​jce.​12917.CrossRefPubMed
Metadaten
Titel
Efficacy of ultrasound-guided axillary/subclavian venous approaches for pacemaker and defibrillator lead implantation: a randomized study
verfasst von
Mattia Liccardo
Pasquale Nocerino
Salzano Gaia
Carmine Ciardiello
Publikationsdatum
15.01.2018
Verlag
Springer US
Erschienen in
Journal of Interventional Cardiac Electrophysiology / Ausgabe 2/2018
Print ISSN: 1383-875X
Elektronische ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-018-0313-7

Weitere Artikel der Ausgabe 2/2018

Journal of Interventional Cardiac Electrophysiology 2/2018 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.