Skip to main content
Erschienen in: Documenta Ophthalmologica 2/2010

01.10.2010 | Case report

Electrodiagnostic and two-wavelength fundus autofluorescence imaging investigations in acute idiopathic maculopathy

verfasst von: Alexander C. Day, Tryfon Rotsos, Graham E. Holder, Adnan Tufail, Anthony G. Robson

Erschienen in: Documenta Ophthalmologica | Ausgabe 2/2010

Einloggen, um Zugang zu erhalten

Abstract

The aim is to characterise a case of acute idiopathic maculopathy (AIM) using detailed electrophysiology and 2-wavelength fundus autofluorescence (FAF) imaging. A 32-year-old woman presented with reduced visual acuity in her right eye. Imaging investigations performed included 1 & 2 wavelength FAF, fluorescein and ICG angiography and Fourier domain OCT imaging. International-standard pattern and full-field electroretinography (PERG; ERG), electro-oculography (EOG) and multifocal ERG testing were performed. Multifocal ERGs demonstrated evidence of localised macular dysfunction consistent with mild right pattern ERG P50 reduction. Full-field ERGs were within normal limits. The EOG was normal bilaterally. The use of 1 & 2 wavelength FAF imaging revealed a low density macular area, not explained by luteal pigment absorption, that was associated with macular dysfunction. Two-wavelength FAF imaging allows the accurate quantification of macular pigment and the imaging of the underlying relative distribution of lipofuscin. AIM was characterised by a discrete area of disrupted retinal pigment epithelium metabolism and atrophy associated with localised macular dysfunction. Complimentary use of dual-wavelength FAF imaging and electrophysiology may have application to disorders other than AIM.
Literatur
1.
Zurück zum Zitat Yannuzzi LA, Jampol LM, Rabb MF, Sorenson JA, Beyrer C, Wilcox LM Jr (1991) Unilateral acute idiopathic maculopathy. Arch Ophthalmol 109(10):1411–1416PubMed Yannuzzi LA, Jampol LM, Rabb MF, Sorenson JA, Beyrer C, Wilcox LM Jr (1991) Unilateral acute idiopathic maculopathy. Arch Ophthalmol 109(10):1411–1416PubMed
2.
Zurück zum Zitat Freund KB, Yannuzzi LA, Barile GR, Spaide RF, Milewski SA, Guyer DR (1996) The expanding clinical spectrum of unilateral acute idiopathic maculopathy. Arch Ophthalmol 114(5):555–559PubMed Freund KB, Yannuzzi LA, Barile GR, Spaide RF, Milewski SA, Guyer DR (1996) The expanding clinical spectrum of unilateral acute idiopathic maculopathy. Arch Ophthalmol 114(5):555–559PubMed
3.
Zurück zum Zitat Beck AP, Jampol LM, Glaser DA, Pollack JS (1996) Is coxsackievirus the cause of unilateral acute idiopathic maculopathy? Arch Ophthalmol 114(5):555–559 Beck AP, Jampol LM, Glaser DA, Pollack JS (1996) Is coxsackievirus the cause of unilateral acute idiopathic maculopathy? Arch Ophthalmol 114(5):555–559
4.
Zurück zum Zitat Aggio FB, Farah ME, Meirelles RL, de Souza EC (2006) STRATUSOCT and multifocal ERG in unilateral acute maculopathy. Graefe’s Arch Clin Exp Ophthalmol 244:510–516CrossRef Aggio FB, Farah ME, Meirelles RL, de Souza EC (2006) STRATUSOCT and multifocal ERG in unilateral acute maculopathy. Graefe’s Arch Clin Exp Ophthalmol 244:510–516CrossRef
5.
Zurück zum Zitat Mathew MR, Webb LA, Bennett HG, Hammer HM (2002) Unilateral acute idiopathic maculopathy (UAIM) masquerading as Best’s disease. Eye 16(4):496–497CrossRefPubMed Mathew MR, Webb LA, Bennett HG, Hammer HM (2002) Unilateral acute idiopathic maculopathy (UAIM) masquerading as Best’s disease. Eye 16(4):496–497CrossRefPubMed
6.
Zurück zum Zitat Lam BL, Lopez PF, Dubovy SR, Liu M (2009) Transient electro-oculogram impairment in unilateral acute idiopathic maculopathy. Doc Ophthalmol 119:157–161CrossRefPubMed Lam BL, Lopez PF, Dubovy SR, Liu M (2009) Transient electro-oculogram impairment in unilateral acute idiopathic maculopathy. Doc Ophthalmol 119:157–161CrossRefPubMed
7.
Zurück zum Zitat Nakazawa T, Yamaguchi K, Shimura M, Yoshida M, Yoshioka Y, Tamai M (2003) Clinical features of bilateral acute idiopathic maculopathy. Jpn J Ophthalmol 47(4):385–391CrossRefPubMed Nakazawa T, Yamaguchi K, Shimura M, Yoshida M, Yoshioka Y, Tamai M (2003) Clinical features of bilateral acute idiopathic maculopathy. Jpn J Ophthalmol 47(4):385–391CrossRefPubMed
8.
Zurück zum Zitat Ghazi NG, Daccache A, Conway BP (2007) Acute idiopathic maculopathy: report of a bilateral case manifesting a macular hole. Ophthalmology 114(5):e1–e6CrossRefPubMed Ghazi NG, Daccache A, Conway BP (2007) Acute idiopathic maculopathy: report of a bilateral case manifesting a macular hole. Ophthalmology 114(5):e1–e6CrossRefPubMed
9.
Zurück zum Zitat Gass JD (1997) Stereoscopic atlas of macular diseases, 4th edn. Mosby-Year Book, St. Louis, p 676 Gass JD (1997) Stereoscopic atlas of macular diseases, 4th edn. Mosby-Year Book, St. Louis, p 676
10.
Zurück zum Zitat Macular pigment optical density measurements V2.3.0.5 (2005) Heidelberg Engineering GmbH. Gerhart Hauptmann Strasse 30, 69221 Dossenheim Macular pigment optical density measurements V2.3.0.5 (2005) Heidelberg Engineering GmbH. Gerhart Hauptmann Strasse 30, 69221 Dossenheim
11.
Zurück zum Zitat Wolf S, Wolf-Schnurrbusch UEK (2007) Macular pigment measurement—theoretical background. In: Holz FG, Schmitz-Valckenberg S, Spaide RF, Bird AC (eds) Atlas of fundus autofluorescence imaging. Springer, New York Wolf S, Wolf-Schnurrbusch UEK (2007) Macular pigment measurement—theoretical background. In: Holz FG, Schmitz-Valckenberg S, Spaide RF, Bird AC (eds) Atlas of fundus autofluorescence imaging. Springer, New York
12.
Zurück zum Zitat Wüstemeyer H, Jahn C, Nestler A, Barth T, Wolf S (2002) A new instrument for the quantification of macular pigment density: first results in patients with AMD and healthy subjects. Graefes Arch Clin Exp Ophthalmol 240(8):666–671CrossRefPubMed Wüstemeyer H, Jahn C, Nestler A, Barth T, Wolf S (2002) A new instrument for the quantification of macular pigment density: first results in patients with AMD and healthy subjects. Graefes Arch Clin Exp Ophthalmol 240(8):666–671CrossRefPubMed
13.
Zurück zum Zitat Marmor MF, Fulton AB, Holder GE, Miyake Y, Brigell M, Bach M (2009) International society for clinical electrophysiology of vision. ISCEV Standard for full-field clinical electroretinography (2008 update). Doc Ophthalmol 118:69–77CrossRefPubMed Marmor MF, Fulton AB, Holder GE, Miyake Y, Brigell M, Bach M (2009) International society for clinical electrophysiology of vision. ISCEV Standard for full-field clinical electroretinography (2008 update). Doc Ophthalmol 118:69–77CrossRefPubMed
14.
Zurück zum Zitat Brown M, Marmor M, Vaegan ZE, Brigell M, Bach M (2006) ISCEV standard for clinical electro-oculography (EOG) 2006. Doc Ophthalmol 113:205–212CrossRefPubMed Brown M, Marmor M, Vaegan ZE, Brigell M, Bach M (2006) ISCEV standard for clinical electro-oculography (EOG) 2006. Doc Ophthalmol 113:205–212CrossRefPubMed
15.
Zurück zum Zitat Holder GE, Brigell MG, Hawlina M, Meigen T, Vargan, Bach M (2007) ISCEV standard for clinical pattern electroretinography (2007 update). Doc Ophthalmol 114:111–116CrossRefPubMed Holder GE, Brigell MG, Hawlina M, Meigen T, Vargan, Bach M (2007) ISCEV standard for clinical pattern electroretinography (2007 update). Doc Ophthalmol 114:111–116CrossRefPubMed
16.
Zurück zum Zitat Hood DC, Bach M, Brigell M, Keating D, Kondo M, Lyons JS, Palmowski-Wolfe AM (2008) ISCEV guidelines for clinical multifocal electroretinography (2007 edition). Doc Ophthalmol 116:1–11CrossRefPubMed Hood DC, Bach M, Brigell M, Keating D, Kondo M, Lyons JS, Palmowski-Wolfe AM (2008) ISCEV guidelines for clinical multifocal electroretinography (2007 edition). Doc Ophthalmol 116:1–11CrossRefPubMed
17.
Zurück zum Zitat Robson AG, Moreland JD, Pauleikhoff D, Morrissey T, Holder GE, Fitzke FW, Bird AC, van Kuijk FJGM (2003) Macular pigment density and distribution: comparison of fundus autofluorescence with minimum motion photometry. Vis Res 43:1765–1775CrossRefPubMed Robson AG, Moreland JD, Pauleikhoff D, Morrissey T, Holder GE, Fitzke FW, Bird AC, van Kuijk FJGM (2003) Macular pigment density and distribution: comparison of fundus autofluorescence with minimum motion photometry. Vis Res 43:1765–1775CrossRefPubMed
18.
Zurück zum Zitat Framme C, Roider J, Sachs HG, Brinkmann R, Gabel VP (2005) Noninvasive imaging and monitoring of retinal pigment epithelium patterns using fundus autofluorescence—review. Curr Med Imaging Rev 1:89–103CrossRef Framme C, Roider J, Sachs HG, Brinkmann R, Gabel VP (2005) Noninvasive imaging and monitoring of retinal pigment epithelium patterns using fundus autofluorescence—review. Curr Med Imaging Rev 1:89–103CrossRef
19.
Zurück zum Zitat Robson AG, Michaelides M, Saihan Z, Bird AC, Webster AR, Moore AT, Fitzke FW, Holder GE (2008) Functional characteristics of patients with retinal dystrophy that manifest abnormal parafoveal annuli of high density fundus autofluorescence; a review and update. Doc Ophthalmol 116(2):79–89CrossRefPubMed Robson AG, Michaelides M, Saihan Z, Bird AC, Webster AR, Moore AT, Fitzke FW, Holder GE (2008) Functional characteristics of patients with retinal dystrophy that manifest abnormal parafoveal annuli of high density fundus autofluorescence; a review and update. Doc Ophthalmol 116(2):79–89CrossRefPubMed
20.
Zurück zum Zitat Delori FC, Goger DG, Hammond BR, Snodderly DM, Burns SA (2001) Macular pigment density measured by autofluorescence spectrometry: comparison with reflectometry and heterochromatic flicker photometry. J Opt Soc Am A Opt Image Sci Vis 18(6):1212–1230CrossRefPubMed Delori FC, Goger DG, Hammond BR, Snodderly DM, Burns SA (2001) Macular pigment density measured by autofluorescence spectrometry: comparison with reflectometry and heterochromatic flicker photometry. J Opt Soc Am A Opt Image Sci Vis 18(6):1212–1230CrossRefPubMed
21.
Zurück zum Zitat Issa PC, der Veen LP, Stijfs A, Holz FG, Scholl HP, Berendschot TT (2009) Quantification of reduced macular pigment optical density in the central retina in macular telangiectasia type 2. Exp Eye Res 89(1):25–31CrossRef Issa PC, der Veen LP, Stijfs A, Holz FG, Scholl HP, Berendschot TT (2009) Quantification of reduced macular pigment optical density in the central retina in macular telangiectasia type 2. Exp Eye Res 89(1):25–31CrossRef
Metadaten
Titel
Electrodiagnostic and two-wavelength fundus autofluorescence imaging investigations in acute idiopathic maculopathy
verfasst von
Alexander C. Day
Tryfon Rotsos
Graham E. Holder
Adnan Tufail
Anthony G. Robson
Publikationsdatum
01.10.2010
Verlag
Springer-Verlag
Erschienen in
Documenta Ophthalmologica / Ausgabe 2/2010
Print ISSN: 0012-4486
Elektronische ISSN: 1573-2622
DOI
https://doi.org/10.1007/s10633-010-9235-0

Weitere Artikel der Ausgabe 2/2010

Documenta Ophthalmologica 2/2010 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.