Skip to main content
Erschienen in: CardioVascular and Interventional Radiology 10/2019

28.06.2019 | Technical Note

Endovascular Neck Stabilization Before EVAR for Infrarenal Aortic Aneurysm in Chronic Aortic Dissection

verfasst von: Yukihisa Ogawa, Hiroshi Nishimaki, Tomotaka Iraha, Nathan K. Itoga, Kiyoshi Chiba, Akiyuki Kotoku, Takaaki Maruhashi, Hidefumi Mimura, Amelia Claire Watkins, Takeshi Miyairi

Erschienen in: CardioVascular and Interventional Radiology | Ausgabe 10/2019

Einloggen, um Zugang zu erhalten

Abstract

Background

Endovascular treatment of infrarenal abdominal aortic aneurysm (AAA) with proximal chronic aortic dissection is challenging as a false and true lumen at the level of the infra-renal neck does not allow a sufficient landing zone. We describe staged endovascular neck stabilization prior to standard endovascular aortic repair (EVAR) for AAA with chronic aortic dissection.

Technique

To create a stable proximal neck (PN) by closing entry tears, thereby resulting in total false lumen thrombosis (FLT) prior to standard EVAR. Case 1 false lumen fenestrations were present at the descending aorta, the right renal artery orifice and PN. After closing the entry tear by thoracic EVAR, an aortic cuff was placed in the true lumen of the PN and renal stenting for the right renal artery was performed. After 2 months, total FLT was achieved, and EVAR was performed. Case 2 false lumen fenestrations were present at the descending, super celiac aorta and PN. After closing the entry by TEVAR, aortic cuffs were placed at infrarenal aorta to close residual entries. After 1 month of achieving total FLT, EVAR was performed. Both cases had no type 1 endoleak during follow-up.

Conclusion

The endovascular neck stabilization is a useful treatment option that facilitates standard EVAR for AAA in chronic aortic dissection.
Literatur
1.
Zurück zum Zitat Stern JR, Cafasso DE, Schneider DB, et al. Totally percutaneous fenestration via the “Cheese-Wire” technique to facilitate endovascular aneurysm repair in chronic aortic dissection. Vasc Endovasc Surg. 2018;52:218–21.CrossRef Stern JR, Cafasso DE, Schneider DB, et al. Totally percutaneous fenestration via the “Cheese-Wire” technique to facilitate endovascular aneurysm repair in chronic aortic dissection. Vasc Endovasc Surg. 2018;52:218–21.CrossRef
2.
Zurück zum Zitat Ullery BW, Chandra V, Dake M, et al. Cheese wire fenestration of a chronic juxtarenal dissection flap to facilitate proximal neck fixation during EVAR. Ann Vasc Surg. 2015;29:124.e1–5.CrossRef Ullery BW, Chandra V, Dake M, et al. Cheese wire fenestration of a chronic juxtarenal dissection flap to facilitate proximal neck fixation during EVAR. Ann Vasc Surg. 2015;29:124.e1–5.CrossRef
3.
Zurück zum Zitat Gissler MC, Ogawa Y, Lee JT, et al. Percutaneous septectomy in chronic dissection with abdominal aortic aneurysm creates uniluminal neck for EVAR. Cardiovasc Interv Radiol. 2017;40:1522–8.CrossRef Gissler MC, Ogawa Y, Lee JT, et al. Percutaneous septectomy in chronic dissection with abdominal aortic aneurysm creates uniluminal neck for EVAR. Cardiovasc Interv Radiol. 2017;40:1522–8.CrossRef
4.
Zurück zum Zitat Dong Z, Fu W, Wang Y, et al. Stent graft-induced new entry after endovascular repair for Stanford type B aortic dissection. J Vasc Surg. 2010;52:1450–7.CrossRefPubMed Dong Z, Fu W, Wang Y, et al. Stent graft-induced new entry after endovascular repair for Stanford type B aortic dissection. J Vasc Surg. 2010;52:1450–7.CrossRefPubMed
5.
Zurück zum Zitat Weng SH, Weng CF, Chen WY, et al. Reintervention for distal stent graft-induced new entry after endovascular repair with a stainless steel-based device in aortic dissection. J Vasc Surg. 2013;57:64–71.CrossRefPubMed Weng SH, Weng CF, Chen WY, et al. Reintervention for distal stent graft-induced new entry after endovascular repair with a stainless steel-based device in aortic dissection. J Vasc Surg. 2013;57:64–71.CrossRefPubMed
6.
Zurück zum Zitat Tashiro J, Baqai A, Goldstein LJ, et al. “Cheese wire” fenestration of a chronic aortic dissection flap for endovascular repair of a contained aneurysm rupture. J Vasc Surg. 2014;60:497–9.CrossRefPubMed Tashiro J, Baqai A, Goldstein LJ, et al. “Cheese wire” fenestration of a chronic aortic dissection flap for endovascular repair of a contained aneurysm rupture. J Vasc Surg. 2014;60:497–9.CrossRefPubMed
7.
Zurück zum Zitat Oliveira N, Gonçalves FB, Rijn MV, et al. Standard endovascular aneurysm repair in patients with wide infrarenal aneurysm necks is associated with increased risk of adverse events. J Vasc Surg. 2017;65:1608–16.CrossRefPubMed Oliveira N, Gonçalves FB, Rijn MV, et al. Standard endovascular aneurysm repair in patients with wide infrarenal aneurysm necks is associated with increased risk of adverse events. J Vasc Surg. 2017;65:1608–16.CrossRefPubMed
8.
Zurück zum Zitat AbuRahma AF, DerDerian T, AbuRahma ZT, et al. Comparative study of clinical outcome of endovascular aortic aneurysms repair in large diameter aortic necks (>31 mm) versus smaller necks. J Vasc Surg. 2018;68:1345–53.CrossRefPubMed AbuRahma AF, DerDerian T, AbuRahma ZT, et al. Comparative study of clinical outcome of endovascular aortic aneurysms repair in large diameter aortic necks (>31 mm) versus smaller necks. J Vasc Surg. 2018;68:1345–53.CrossRefPubMed
9.
Zurück zum Zitat Gargiulo M, Gallitto E, Wattez H, et al. Outcomes of endovascular aneurysm repair performed in abdominal aortic aneurysms with large infrarenal necks. J Vasc Surg. 2017;66:1065–72.CrossRefPubMed Gargiulo M, Gallitto E, Wattez H, et al. Outcomes of endovascular aneurysm repair performed in abdominal aortic aneurysms with large infrarenal necks. J Vasc Surg. 2017;66:1065–72.CrossRefPubMed
10.
Zurück zum Zitat Howard DPJ, Marron CD, Sideso E, et al. Influence of proximal aortic neck diameter on durability of aneurysm sealing and overall survival in patients undergoing endovascular aneurysm repair. Real world data from the Gore Global Registry for Endovascular Aortic Treatment (GREAT). Eur J Vasc Endovasc Surg. 2018;56:189–99.CrossRefPubMed Howard DPJ, Marron CD, Sideso E, et al. Influence of proximal aortic neck diameter on durability of aneurysm sealing and overall survival in patients undergoing endovascular aneurysm repair. Real world data from the Gore Global Registry for Endovascular Aortic Treatment (GREAT). Eur J Vasc Endovasc Surg. 2018;56:189–99.CrossRefPubMed
Metadaten
Titel
Endovascular Neck Stabilization Before EVAR for Infrarenal Aortic Aneurysm in Chronic Aortic Dissection
verfasst von
Yukihisa Ogawa
Hiroshi Nishimaki
Tomotaka Iraha
Nathan K. Itoga
Kiyoshi Chiba
Akiyuki Kotoku
Takaaki Maruhashi
Hidefumi Mimura
Amelia Claire Watkins
Takeshi Miyairi
Publikationsdatum
28.06.2019
Verlag
Springer US
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 10/2019
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-019-02277-8

Weitere Artikel der Ausgabe 10/2019

CardioVascular and Interventional Radiology 10/2019 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.