Zum Inhalt

Erratum to: Osseointegration of standard and mini dental implants: a histomorphometric comparison

  • Open Access
  • 01.12.2017
  • Erratum
Erschienen in:
download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN
The online version of the original article can be found under doi:10.1186/s40729-017-0079-1.
This erratum was published to acknowlege corrections to the Statistical Methods and Results sections. The original manuscript is also available online.

Erratum

Upon Publication of the original manuscript [1] several discrepancies were highlighted in the following sections; Statistical methods and Results. These errors have since been acknowledged and corrected in this erratum.
The text in the subsection “Statistical methods” originally read:
“Mean values and standard deviations were calculated for bone implant contact (BIC). Univariate analysis was done for all the evaluations. Analysis of variance (ANOVA) was used to analyze the differences between the two implants. P value <0.05 was considered significant. Statistical analyses were carried out with the help of SPSS statistical software version 18.”
This should read:
“Mean values and standard deviations were calculated for bone implant contact (BIC). The mean differences of % BIC between the groups were verified through a Mann–Whitney nonparametric test, P value <0.05 was considered significant. Statistical analyses were carried out with the help of SPSS statistical software version 18.”
The final paragraph of the results section reads:
The median value of% BIC was 58.5 and the MDI group (IQR 7) and control group was 57.0 (IQR 5.0) (Tables 1 and 2).The mean differences of % BIC between the groups were verified through Mann–Whitney nonparametric test. There was no significant difference between the % bone implant contact (BIC) length of both the implants (P value >0.05).
This should read:
Percentage of BIC ranged from 45 to 67% in both the groups. The median value of % BIC was 58.5, MDI group (IQR 8), and control group was 57.0 (IQR 5.5) (Tables 1 and 2). The mean differences of % BIC between the groups were verified through a Mann–Whitney nonparametric test. There was no significant difference between the % bone implant contact (BIC) length of both the implants (P value >0 .05).
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
download
DOWNLOAD
print
DRUCKEN
Titel
Erratum to: Osseointegration of standard and mini dental implants: a histomorphometric comparison
Verfasst von
Jagjit S. Dhaliwal
Rubens F. Albuquerque Jr
Monzur Murshed
Jocelyne S. Feine
Publikationsdatum
01.12.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Implant Dentistry / Ausgabe 1/2017
Elektronische ISSN: 2198-4034
DOI
https://doi.org/10.1186/s40729-017-0088-0
1.
Zurück zum Zitat Dhaliwal JS, Albuquerque RF, Murshed M, Feine JS. Osseointegration of standard and mini dental implants: a histomorphometric comparison. Int J Implant Dent. 2017;3(1):15.CrossRefPubMedPubMedCentral

Neu im Fachgebiet Zahnmedizin

Krankenkassen erklären sich bereit, therapeutische Wundprodukte weiterhin zu erstatten

  • 05.12.2025
  • EBM
  • Nachrichten

Aktuell gesteigertes Regressrisiko bei der Verordnung therapeutischer Wundauflagen? Vielerorts signalisieren Kassen und KVen schon Entwarnung.

Betriebliche Weihnachtsfeier: So ist die Gesetzliche Unfallversicherung mit von der Partie

Damit die Gesetzliche Unfallversicherung auch dann leistet, wenn während der betrieblichen Weihnachtsfeier gestolpert wird und hingeschlagen, sind einige Voraussetzungen zu beachten.

gematik verlängert Frist für Austausch der E-Arztausweise

Nachdem die Berichte über Probleme beim Austausch der E-Arztausweise für die digitale Signatur in der Telematikinfrastruktur nicht abrissen, hat die gematik jetzt die Notbremsung eingeleitet: Demnach können eHBA der alten Version nun bis 30. Juni 2026 genutzt werden. Für alte Konnektoren gibt es keinen Aufschub.

Oft genug, aber nicht sauber genug

Viele Deutsche putzen regelmäßig ihre Zähne – doch die meisten erreichen keine Plaquefreiheit. Studien zeigen: Unsystematisches Putzen führt oft zu Zahnfleischentzündungen. Forschende wollen mit KI und gezielter Anleitung die Mundhygiene verbessern..

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise
Versorgung einer infizierten Wunde bei diabetischem Fuß/© kirov1969 / Stock.adobe.com (Symbolbild mit Fotomodellen), Glatte Straße mit Schnee bedeckt/© Urheber / Agentur (Symbolbild mit Fotomodell), Arztausweis/© Ulrich Zillmann / FotoMedienService / picture alliance (Symbolbild mit Fotomodell)