Estimation of local statistical noise in PET images induced by attenuation inside the body

verfasst von: Hideaki Kitamura, Kazumasa Inoue, Tatsuya Sasaki, Keisuke Tsuda, Hirotaka Fujimori, Takashi Tanaka, Masahiro Fukushi, Noriyuki Moriyama, Hirofumi Fujii

Erschienen in: Annals of Nuclear Medicine | Ausgabe 3/2010

Einloggen, um Zugang zu erhalten

Abstract

Objectives

In positron emission tomography/computed tomography (PET/CT) examinations, the standardized uptake value (SUV) is a commonly used index to evaluate the activity of cancer. The precision of SUV is directly affected by the local statistical noise in PET images because SUV is calculated based on the counts on PET image data. The purpose of this study was to estimate the local statistical noise in the PET image caused by attenuation of annihilation photons inside the body.

Methods

To estimate the local statistical noise, we defined the number proportional to the standard deviation of a voxel caused by attenuation using CT image data. The conversion table between the number obtained from the CT image data and the actually measured standard deviation of a voxel was made by performing experiments with different forms or sizes of phantoms and scattering bodies. We compared the standard deviation of a voxel estimated by the method we proposed with actually measured ones.

Results

The standard deviation of a voxel in the PET image varied according to the size of the phantom. The effect of attenuation on the standard deviation of a voxel was more significant in the 3D mode than in the 2D mode. The correlation coefficients between the estimated standard deviation and actually measured standard deviation were 0.98 and 0.99 in the 2D mode and 3D mode, respectively.

Conclusions

Our algorithm favorably estimated the local statistical noise in PET image data using CT image data, regardless of object size, although the consideration was limited for phantoms with homogeneous interiors.
Literatur
1.
Zurück zum Zitat Miller E, Metser U, Avrahami G, Dvir R, Valdman D, Sira LB, et al. Role of 18F-FDG PET/CT in staging and follow-up of lymphoma in pediatric and young adult patients. J Comput Assist Tomogr. 2006;30:689–94.CrossRefPubMed Miller E, Metser U, Avrahami G, Dvir R, Valdman D, Sira LB, et al. Role of 18F-FDG PET/CT in staging and follow-up of lymphoma in pediatric and young adult patients. J Comput Assist Tomogr. 2006;30:689–94.CrossRefPubMed
2.
Zurück zum Zitat Shankar LK, Hoffman JM, Bacharach S, Graham MM, Karp J, Lammertsma AA, et al. National Cancer Institute. National Cancer Institute. Consensus recommendations for the use of 18F-FDG PET as an indicator of therapeutic response in patients in National Cancer Institute Trials. J Nucl Med. 2006;47:1059–66.PubMed Shankar LK, Hoffman JM, Bacharach S, Graham MM, Karp J, Lammertsma AA, et al. National Cancer Institute. National Cancer Institute. Consensus recommendations for the use of 18F-FDG PET as an indicator of therapeutic response in patients in National Cancer Institute Trials. J Nucl Med. 2006;47:1059–66.PubMed
3.
Zurück zum Zitat Bradley JD, Perez CA, Dehdashti F, Siegel BA. Implementing biologic target volumes in radiation treatment planning for non-small cell lung cancer. J Nucl Med. 2004;45S:96S–101S. Bradley JD, Perez CA, Dehdashti F, Siegel BA. Implementing biologic target volumes in radiation treatment planning for non-small cell lung cancer. J Nucl Med. 2004;45S:96S–101S.
4.
Zurück zum Zitat Ho CL, Dehdashti F, Griffeth LK, Buse PE, Balfe DM, Siegel BA. FDG-PET evaluation of indeterminate pancreatic masses. J Comput Assist Tomogr. 1996;20:363–9.CrossRefPubMed Ho CL, Dehdashti F, Griffeth LK, Buse PE, Balfe DM, Siegel BA. FDG-PET evaluation of indeterminate pancreatic masses. J Comput Assist Tomogr. 1996;20:363–9.CrossRefPubMed
5.
Zurück zum Zitat Hellwig D, Graeter TP, Ukena D, Groeschel A, Sybrecht GW, Schaefers HJ, et al. 18F-FDG PET for mediastinal staging of lung cancer: which SUV threshold makes sense? J Nucl Med. 2007;48:1761–6.CrossRefPubMed Hellwig D, Graeter TP, Ukena D, Groeschel A, Sybrecht GW, Schaefers HJ, et al. 18F-FDG PET for mediastinal staging of lung cancer: which SUV threshold makes sense? J Nucl Med. 2007;48:1761–6.CrossRefPubMed
6.
Zurück zum Zitat Nickerson LD, Narayana S, Lancaster JL, Fox PT, Gao JH. Estimation of the local statistical noise in positron emission tomography revisited: practical implementation. Neuroimage. 2003;19 (2 Pt 1):442–456. Nickerson LD, Narayana S, Lancaster JL, Fox PT, Gao JH. Estimation of the local statistical noise in positron emission tomography revisited: practical implementation. Neuroimage. 2003;19 (2 Pt 1):442–456.
7.
Zurück zum Zitat Zhang B, Zeng GL. Study of noise propagation and the effects of insufficient numbers of projection angles and detector samplings for iterative reconstruction using planar-integral data. Med Phys. 2006;33:3124–34.CrossRefPubMed Zhang B, Zeng GL. Study of noise propagation and the effects of insufficient numbers of projection angles and detector samplings for iterative reconstruction using planar-integral data. Med Phys. 2006;33:3124–34.CrossRefPubMed
8.
Zurück zum Zitat Halpern BS, Dahlbom M, Auerbach MA, Schiepers C, Fueger BJ, Weber WA, et al. Optimizing imaging protocols for overweight and obese patients: a lutetium orthosilicate PET/CT study. J Nucl Med. 2005;46:603–7.PubMed Halpern BS, Dahlbom M, Auerbach MA, Schiepers C, Fueger BJ, Weber WA, et al. Optimizing imaging protocols for overweight and obese patients: a lutetium orthosilicate PET/CT study. J Nucl Med. 2005;46:603–7.PubMed
9.
Zurück zum Zitat Townsend DW. Physical principles and technology of clinical PET imaging. Ann Acad Med Singapore. 2004;33:133–45.PubMed Townsend DW. Physical principles and technology of clinical PET imaging. Ann Acad Med Singapore. 2004;33:133–45.PubMed
10.
Zurück zum Zitat Kinahan PE, Hasegawa BH, Beyer T. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners. Semin Nucl Med. 2003;33:166–79.CrossRefPubMed Kinahan PE, Hasegawa BH, Beyer T. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners. Semin Nucl Med. 2003;33:166–79.CrossRefPubMed
11.
Zurück zum Zitat Kak AC, Slaney M. Algorithms for reconstruction with non-diffracting sources. In: Principles of computerized tomographic imaging. Classics in applied mathematics, vol. 33. New York; The Society for Industrial and Applied Mathematics, 2001. p. 49–112. Kak AC, Slaney M. Algorithms for reconstruction with non-diffracting sources. In: Principles of computerized tomographic imaging. Classics in applied mathematics, vol. 33. New York; The Society for Industrial and Applied Mathematics, 2001. p. 49–112.
12.
Zurück zum Zitat Barrett HH, Wilson DW, Tsui BM. Noise properties of the EM algorithm: I. Theory. Phys Med Biol. 1994;39:833–46.CrossRefPubMed Barrett HH, Wilson DW, Tsui BM. Noise properties of the EM algorithm: I. Theory. Phys Med Biol. 1994;39:833–46.CrossRefPubMed
13.
Zurück zum Zitat Wang W, Gindi G. Noise analysis of MAP-EM algorithms for emission tomography. Phys Med Biol. 1997;42:2215–32.CrossRefPubMed Wang W, Gindi G. Noise analysis of MAP-EM algorithms for emission tomography. Phys Med Biol. 1997;42:2215–32.CrossRefPubMed
14.
Zurück zum Zitat Defrise M, Kinahan PE, Michel C. Image reconstruction algorithms in PET. In: Valk PE, Bailey DL, Townsend DW, Maisey MN, editors. Positron emission tomography. Basic science and clinical practice. London: Springer; 2003. p. 91–114. Defrise M, Kinahan PE, Michel C. Image reconstruction algorithms in PET. In: Valk PE, Bailey DL, Townsend DW, Maisey MN, editors. Positron emission tomography. Basic science and clinical practice. London: Springer; 2003. p. 91–114.
15.
Zurück zum Zitat Matej S, Karp JS, Lewitt RM, Becher AJ. Performance of the Fourier rebinning algorithm for PET with large acceptance angles. Phys Med Biol. 1998;43:787–95.CrossRefPubMed Matej S, Karp JS, Lewitt RM, Becher AJ. Performance of the Fourier rebinning algorithm for PET with large acceptance angles. Phys Med Biol. 1998;43:787–95.CrossRefPubMed
16.
Zurück zum Zitat Meilele SR, Badawi RD. Quantitative techniques in PET. In: Valk PE, Bailey DL, Townsend DW, Maisey MN, editors. Positron emission tomography. Basic science and clinical practice. London: Springer; 2003. p. 115–46. Meilele SR, Badawi RD. Quantitative techniques in PET. In: Valk PE, Bailey DL, Townsend DW, Maisey MN, editors. Positron emission tomography. Basic science and clinical practice. London: Springer; 2003. p. 115–46.
17.
Zurück zum Zitat Ollinger JM. Model-based scatter correction for fully 3D PET. Phys Med Biol. 1996;41:153–76.CrossRefPubMed Ollinger JM. Model-based scatter correction for fully 3D PET. Phys Med Biol. 1996;41:153–76.CrossRefPubMed
18.
Zurück zum Zitat Bettinardi V, Danna M, Savi A, Lecchi M, Castiglioni I, Gilardi MC, et al. Performance evaluation of the new whole-body PET/CT scanner: discovery ST. Eur J Nucl Med Mol Imaging. 2004;31:867–81.CrossRefPubMed Bettinardi V, Danna M, Savi A, Lecchi M, Castiglioni I, Gilardi MC, et al. Performance evaluation of the new whole-body PET/CT scanner: discovery ST. Eur J Nucl Med Mol Imaging. 2004;31:867–81.CrossRefPubMed
19.
Zurück zum Zitat Gies M, Kalender WA, Wolf H, Suess C. Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies. Med Phys. 1999;26:2235–47.CrossRefPubMed Gies M, Kalender WA, Wolf H, Suess C. Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies. Med Phys. 1999;26:2235–47.CrossRefPubMed
20.
Zurück zum Zitat El Fakhri G, Santos PA, Badawi RD, Holdsworth CH, Van Den Abbeele AD, Kijewski MF. Impact of acquisition geometry, image processing, and patient size on lesion detection in whole-body 18F-FDG PET. J Nucl Med. 2007;48:1951–60.CrossRefPubMed El Fakhri G, Santos PA, Badawi RD, Holdsworth CH, Van Den Abbeele AD, Kijewski MF. Impact of acquisition geometry, image processing, and patient size on lesion detection in whole-body 18F-FDG PET. J Nucl Med. 2007;48:1951–60.CrossRefPubMed
Metadaten
Titel
Estimation of local statistical noise in PET images induced by attenuation inside the body
verfasst von
Hideaki Kitamura
Kazumasa Inoue
Tatsuya Sasaki
Keisuke Tsuda
Hirotaka Fujimori
Takashi Tanaka
Masahiro Fukushi
Noriyuki Moriyama
Hirofumi Fujii
Publikationsdatum
01.04.2010
Verlag
Springer Japan
Erschienen in
Annals of Nuclear Medicine / Ausgabe 3/2010
Print ISSN: 0914-7187
Elektronische ISSN: 1864-6433
DOI
https://doi.org/10.1007/s12149-010-0355-0

Weitere Artikel der Ausgabe 3/2010

Annals of Nuclear Medicine 3/2010 Zur Ausgabe