Skip to main content
Erschienen in: Journal of Digital Imaging 5/2016

18.02.2016

Estimation of Radiation Dose in CT Based on Projection Data

verfasst von: Xiaoyu Tian, Zhye Yin, Bruno De Man, Ehsan Samei

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 5/2016

Einloggen, um Zugang zu erhalten

Abstract

Managing and optimizing radiation dose has become a core problem for the CT community. As a fundamental step for dose optimization, accurate and computationally efficient dose estimates are crucial. The purpose of this study was to devise a computationally efficient projection-based dose metric. The absorbed energy and object mass were individually modeled using the projection data. The absorbed energy was estimated using the difference between intensity of the primary photon and the exit photon. The mass was estimated using the volume under the attenuation profile. The feasibility of the approach was evaluated across phantoms with a broad size range, various kVp settings, and two bowtie filters, using a simulation tool, the Computer Assisted Tomography SIMulator (CATSIM) software. The accuracy of projection-based dose estimation was validated against Monte Carlo (MC) simulations. The relationship between projection-based dose metric and MC dose estimate was evaluated using regression models. The projection-based dose metric showed a strong correlation with Monte Carlo dose estimates (R 2 > 0.94). The prediction errors for the projection-based dose metric were all below 15 %. This study demonstrated the feasibility of computationally efficient dose estimation requiring only the projection data.
Literatur
2.
Zurück zum Zitat Berdahl CT, Vermeulen MJ, Larson DB, Schull MJ: Emergency department computed tomography utilization in the United States and Canada. Ann Emerg Med 2013 Berdahl CT, Vermeulen MJ, Larson DB, Schull MJ: Emergency department computed tomography utilization in the United States and Canada. Ann Emerg Med 2013
3.
Zurück zum Zitat IMV: CT Market Outlook Report, 2012. IMV Medical Information Division, Des Plaines, 2012 IMV: CT Market Outlook Report, 2012. IMV Medical Information Division, Des Plaines, 2012
4.
Zurück zum Zitat Brenner DJ, Hall EJ: Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284, 2007CrossRefPubMed Brenner DJ, Hall EJ: Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284, 2007CrossRefPubMed
5.
Zurück zum Zitat Pearce MS, Salotti JA, Little MP, McHugh K, Lee C, Kim KP, et al: Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet 380:499–505, 2012CrossRefPubMedPubMedCentral Pearce MS, Salotti JA, Little MP, McHugh K, Lee C, Kim KP, et al: Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet 380:499–505, 2012CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat FDA: Draft guidance for industry and food and drug administration staff: pediatric information for x-ray imaging device premarket notifications, in guidance documents (medical devices and radiation-emitting products) 2012. U.S. Department of Health and Human Services: Rockville FDA: Draft guidance for industry and food and drug administration staff: pediatric information for x-ray imaging device premarket notifications, in guidance documents (medical devices and radiation-emitting products) 2012. U.S. Department of Health and Human Services: Rockville
7.
Zurück zum Zitat McCollough CH, Chen GH, Kalender W, Leng S, Samei E, Taguchi K, et al: Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT. Radiology 264:567–580, 2012CrossRefPubMedPubMedCentral McCollough CH, Chen GH, Kalender W, Leng S, Samei E, Taguchi K, et al: Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT. Radiology 264:567–580, 2012CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Boone JM, Hendee WR, McNitt-Gray MF, Seltzer SE: Radiation exposure from CT scans: how to close our knowledge gaps, monitor and safeguard exposure—proceedings and recommendations of the Radiation Dose Summit, sponsored by NIBIB, February 24–25, 2011. Radiology 265:544–554, 2012CrossRefPubMedPubMedCentral Boone JM, Hendee WR, McNitt-Gray MF, Seltzer SE: Radiation exposure from CT scans: how to close our knowledge gaps, monitor and safeguard exposure—proceedings and recommendations of the Radiation Dose Summit, sponsored by NIBIB, February 24–25, 2011. Radiology 265:544–554, 2012CrossRefPubMedPubMedCentral
9.
12.
13.
Zurück zum Zitat Tian X, Li X, Segars WP, Paulson EK, Frush DP, Samei E: Pediatric chest and abdominopelvic CT: organ dose estimation based on 42 patient models. Radiology 270:535–547, 2014CrossRefPubMedPubMedCentral Tian X, Li X, Segars WP, Paulson EK, Frush DP, Samei E: Pediatric chest and abdominopelvic CT: organ dose estimation based on 42 patient models. Radiology 270:535–547, 2014CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Frush DP: Patient-specific radiation dose and cancer risk for pediatric chest CT. Radiology 259:862–874, 2011CrossRefPubMedPubMedCentral Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Frush DP: Patient-specific radiation dose and cancer risk for pediatric chest CT. Radiology 259:862–874, 2011CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Geyer AM, O’Reilly S, Lee C, Long DJ, Bolch WE: The UF/NCI family of hybrid computational phantoms representing the current US population of male and female children, adolescents, and adults-application to CT dosimetry. Phys Med Biol 59:5225–5242, 2014CrossRefPubMed Geyer AM, O’Reilly S, Lee C, Long DJ, Bolch WE: The UF/NCI family of hybrid computational phantoms representing the current US population of male and female children, adolescents, and adults-application to CT dosimetry. Phys Med Biol 59:5225–5242, 2014CrossRefPubMed
16.
Zurück zum Zitat De Man B, Basu S, Chandra N, Dunham B, Edic P, Iatrou M, McOlash S, Sainath P, Shaughnessy C, Tower B, Williams E: “CatSim: a new computer assisted tomography simulation environment”. Proc. SPIE 6510, Medical Imaging 2007: Physics of Medical Imaging De Man B, Basu S, Chandra N, Dunham B, Edic P, Iatrou M, McOlash S, Sainath P, Shaughnessy C, Tower B, Williams E: “CatSim: a new computer assisted tomography simulation environment”. Proc. SPIE 6510, Medical Imaging 2007: Physics of Medical Imaging
18.
Zurück zum Zitat Ay MR, Mehranian A, Maleki A, Ghadiri H, Ghafarian P, Zaidi H: Experimental assessment of the influence of beam hardening filters on image quality and patient dose in volumetric 64-slice X-ray CT scanners. Phys Med 29:249–260, 2013CrossRefPubMed Ay MR, Mehranian A, Maleki A, Ghadiri H, Ghafarian P, Zaidi H: Experimental assessment of the influence of beam hardening filters on image quality and patient dose in volumetric 64-slice X-ray CT scanners. Phys Med 29:249–260, 2013CrossRefPubMed
19.
Zurück zum Zitat Habibzadeh MA, Ay MR, Asl AR, Ghadiri H, Zaidi H: Impact of miscentering on patient dose and image noise in x-ray CT imaging: phantom and clinical studies. Phys Med 28:191–199, 2012CrossRefPubMed Habibzadeh MA, Ay MR, Asl AR, Ghadiri H, Zaidi H: Impact of miscentering on patient dose and image noise in x-ray CT imaging: phantom and clinical studies. Phys Med 28:191–199, 2012CrossRefPubMed
20.
Zurück zum Zitat Tsalafoutas IA, Georgolopoulou P, Abatzoglou I: CT dosimetry considerations in non typical conditions: the effect of scan field of view and table height selection. Phys Med 28:83–90, 2012CrossRefPubMed Tsalafoutas IA, Georgolopoulou P, Abatzoglou I: CT dosimetry considerations in non typical conditions: the effect of scan field of view and table height selection. Phys Med 28:83–90, 2012CrossRefPubMed
Metadaten
Titel
Estimation of Radiation Dose in CT Based on Projection Data
verfasst von
Xiaoyu Tian
Zhye Yin
Bruno De Man
Ehsan Samei
Publikationsdatum
18.02.2016
Verlag
Springer International Publishing
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 5/2016
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-016-9869-x

Weitere Artikel der Ausgabe 5/2016

Journal of Digital Imaging 5/2016 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.