11.10.2019 | Original Research

Evaluating improvements in cardiac dosimetry in breast radiotherapy and comparison of cardiac sparing techniques

Zeitschrift:
Journal of Radiation Oncology
Autoren:
Ahmad M. Karimi, Martin C. Tom, Bindu V. Manyam, Elizabeth Obi, Rahul D. Tendulkar, Sheen Cherian, Christopher Fleming, Eva Suarez, Mihir Naik, Chirag Shah
Wichtige Hinweise

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Abstract

Purpose/objective(s)

Data from Darby et al. demonstrated that cardiac dose in patients undergoing breast radiation therapy is associated with cardiac events. Cardiac dose is primarily dependent on treatment laterality and treatment fields. More recently, techniques such deep inspiratory breath hold (DIBH) and prone positioning have been used as cardiac sparing techniques. The purpose of this study is to assess changes in cardiac dosimetry with cardiac sparing techniques.

Materials/methods

This retrospective study included breast cancer patients treated from 2010 to 2018 at a single institution. Mean heart dose (MHD) was analyzed with respect to treatment era, laterality, cardiac sparing technique, and treatment fields, including regional nodal irradiation (RNI) and internal mammary nodal irradiation (IMNI).

Results

Seven hundred sixty-five patients were included in this study. Average MHD was 1.87 Gy for left-sided cases and 0.71 Gy for right-sided cases (p < 0.0001). For left-sided cases, the average MHD without RNI, RNI without IMNI, and RNI with IMNI was 1.40 Gy, 2.01 Gy, and 3.48 Gy respectively. For left-sided cases without RNI, the average MHD decreased from 1.61 to 1.22 Gy using DIBH (p < 0.0001), and to 1.02 Gy with prone positioning (p < 0.0001). There was no difference in MHD between DIBH and prone techniques (p = 0.44). For left-sided cases with RNI, DIBH reduced the average MHD from 2.4 to 2.1 Gy (p = 0.04). Following the 2013 publication of Darby et al., the average MHD significantly decreased for left-sided RT cases (2.02 vs. 1.83 Gy, p = 0.03) due to increased institutional adoption of cardiac-sparing techniques.

Conclusion

Cardiac doses were lower following the 2013 publication of Darby et al. due to greater use of cardiac sparing techniques. Overall, the average MHD was < 1 Gy and < 2 Gy for right and left breast cancers, respectively, with lower doses achieved using DIBH and prone positioning as cardiac sparing techniques.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Jetzt e.Med zum Sonderpreis bestellen!

Weitere Produktempfehlungen anzeigen
Literatur
Über diesen Artikel
  1. Sie können e.Med Radiologie 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

  2. Das kostenlose Testabonnement läuft nach 14 Tagen automatisch und formlos aus. Dieses Abonnement kann nur einmal getestet werden.


 

Neu im Fachgebiet Onkologie

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Onkologie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise