Skip to main content
Erschienen in: Pediatric Cardiology 5/2021

15.04.2021 | Original Article

Evaluating Left Ventricular Systolic Synchronicity with Real-Time 3D Echocardiography in Newborns

verfasst von: Min Xu, Weidong Ren, Feng Xiong, Shuzhen Wang, Lijuan Zhang, Chunxia Liu, Xiaofeng Huang, Yali Lei

Erschienen in: Pediatric Cardiology | Ausgabe 5/2021

Einloggen, um Zugang zu erhalten

Abstract

Knowing the normal values of left ventricular (LV) systolic synchronicity in the early neonatal period is very important for understanding myocardial function. This retrospective study analyzed data of 105 newborns who were examined using real-time 3-dimensional echocardiography (RT3DE). The time to the point of minimal regional systolic volume (Tmsv) was measured from volume–time curves in each segment. Standard deviation (SD) and maximal difference (Dif) of Tmsv were calculated from 16 (6 basal/6 mid/4 apical), 12 (6 basal/6 mid), and 6 (basal) LV segments with the corresponding parameters adjusted for the R–R interval. Influences of age, sex, gestational age, birth weight, and heart rate on parameters were explored. Data showed no significant difference among Tmsv-16-SD, Tmsv-12-SD, and Tmsv-6-SD. A strong correlation was found between Tmsv-6-SD and Tmsv-6-Dif (r = 0.83, P < 0.001), Tmsv-12-SD and Tmsv-6-SD (r = 0.77, P < 0.001), and Tmsv-12-Dif and Tmsv-6-Dif (r = 0.76, P < 0.001) and a moderate correlation was found between Tmsv-16-SD and Tmsv-16-Dif (r = 0.66, P < 0.001), Tmsv-6-SD and Tmsv-12-Dif (r = 0.62, P < 0.001), and Tmsv-12-SD and Tmsv-6-Dif (r = 0.61, P < 0.001). Heart rate correlated negatively with Tmsv (r = − 0.03 to − 0.11, P < 0.004–0.000), but had no effect on parameters adjusted for %R–R. Age, sex, gestational age, and birth weight did not affect any of these parameters. Tmsv-Dif and Tmsv-SD measured from 16 segments using RT3DE are useful as possible parameters for evaluating LV systolic synchronicity in normal newborns.
Literatur
1.
Zurück zum Zitat Nestaas E, Stoylen A, Brunvand L et al (2009) Tissue Doppler derived longitudinal strain and strain rate during the first 3 days of life in healthy term neonates. Pediatr Res 65:357–362CrossRef Nestaas E, Stoylen A, Brunvand L et al (2009) Tissue Doppler derived longitudinal strain and strain rate during the first 3 days of life in healthy term neonates. Pediatr Res 65:357–362CrossRef
2.
Zurück zum Zitat Marcus KA, Janousek J, Barends ME et al (2011) Synchronicity of systolic deformation in healthy pediatric and young adult subjects: a two-dimensional strain echocardiography study. Am J Physiol Heart Circ Physiol 302:196–205CrossRef Marcus KA, Janousek J, Barends ME et al (2011) Synchronicity of systolic deformation in healthy pediatric and young adult subjects: a two-dimensional strain echocardiography study. Am J Physiol Heart Circ Physiol 302:196–205CrossRef
3.
Zurück zum Zitat Dorosz JL, Lezotte DC, Weitzenkamp DA et al (2012) Performance of 3-dimensional echocardiography in measuring left ventricular volumes and ejection fraction: a systematic review and meta-analysis. J Am Coll Cardiol 59:1799–1808CrossRef Dorosz JL, Lezotte DC, Weitzenkamp DA et al (2012) Performance of 3-dimensional echocardiography in measuring left ventricular volumes and ejection fraction: a systematic review and meta-analysis. J Am Coll Cardiol 59:1799–1808CrossRef
4.
Zurück zum Zitat Monaghan MJ (2006) Role of real time 3D echocardiography in evaluating the left ventricle. Heart 92:131–136CrossRef Monaghan MJ (2006) Role of real time 3D echocardiography in evaluating the left ventricle. Heart 92:131–136CrossRef
5.
Zurück zum Zitat Kapetanakis S, Kearney MT, Siva A et al (2005) Real-time three-dimensional echocardiography: a novel technique to quantify global left ventricular mechanical dyssynchrony. Circulation 112:992–1000CrossRef Kapetanakis S, Kearney MT, Siva A et al (2005) Real-time three-dimensional echocardiography: a novel technique to quantify global left ventricular mechanical dyssynchrony. Circulation 112:992–1000CrossRef
6.
Zurück zum Zitat Balluz R, Liu L, Zhou X et al (2013) Real time three-dimensional echocardiography for quantification of ventricular volumes, mass, and function in children with congenital and acquired heart diseases. Echocardiography 30:472–482CrossRef Balluz R, Liu L, Zhou X et al (2013) Real time three-dimensional echocardiography for quantification of ventricular volumes, mass, and function in children with congenital and acquired heart diseases. Echocardiography 30:472–482CrossRef
7.
Zurück zum Zitat Singh Y (2019) Evolution of left ventricular function in preterm infants: long-term significance. Kardiol Pol 77:417–418CrossRef Singh Y (2019) Evolution of left ventricular function in preterm infants: long-term significance. Kardiol Pol 77:417–418CrossRef
8.
Zurück zum Zitat Sun JP, Super DM, Salvator A et al (2002) Quantification of regional left ventricular wall motion in newborns by color kinesis. J Am Soc Echocardiogr 15:356–363CrossRef Sun JP, Super DM, Salvator A et al (2002) Quantification of regional left ventricular wall motion in newborns by color kinesis. J Am Soc Echocardiogr 15:356–363CrossRef
9.
Zurück zum Zitat Cui W, Roberson DA, Chen Z et al (2008) Systolic and diastolic time intervals measured from Doppler tissue imaging: normal values and Z-score tables, and effects of age, heart rate, and body surface area. J Am Soc Echocardiogr 21:361–370CrossRef Cui W, Roberson DA, Chen Z et al (2008) Systolic and diastolic time intervals measured from Doppler tissue imaging: normal values and Z-score tables, and effects of age, heart rate, and body surface area. J Am Soc Echocardiogr 21:361–370CrossRef
10.
Zurück zum Zitat Krell K, Laser KT, Dalla-Pozza R et al (2018) Real-time three-dimensional echocardiography of the left ventricle-pediatric percentiles and head-to-head comparison of different contour-finding algorithms: a multicenter study. J Am Soc Echocardiogr 31:702–711CrossRef Krell K, Laser KT, Dalla-Pozza R et al (2018) Real-time three-dimensional echocardiography of the left ventricle-pediatric percentiles and head-to-head comparison of different contour-finding algorithms: a multicenter study. J Am Soc Echocardiogr 31:702–711CrossRef
11.
Zurück zum Zitat Alp H, Karaarslan S, Baysal T et al (2012) Normal values of left and right ventricular function measured by M-mode, pulsed doppler and Doppler tissue imaging in healthy term neonates during a 1-year period. Early Hum Dev 88:853–859CrossRef Alp H, Karaarslan S, Baysal T et al (2012) Normal values of left and right ventricular function measured by M-mode, pulsed doppler and Doppler tissue imaging in healthy term neonates during a 1-year period. Early Hum Dev 88:853–859CrossRef
12.
Zurück zum Zitat Nagasawa H (2014) Evaluation of left ventricular volumes in the early neonatal period using three-dimensional echocardiography. Cardiol Young 24:685–693CrossRef Nagasawa H (2014) Evaluation of left ventricular volumes in the early neonatal period using three-dimensional echocardiography. Cardiol Young 24:685–693CrossRef
13.
Zurück zum Zitat Ha KS, Choi BM, Lee EH et al (2018) Chronological echocardiographic changes in healthy term neonates within postnatal 72 hours using Doppler studies. J Korean Med Sci 33:e155CrossRef Ha KS, Choi BM, Lee EH et al (2018) Chronological echocardiographic changes in healthy term neonates within postnatal 72 hours using Doppler studies. J Korean Med Sci 33:e155CrossRef
14.
Zurück zum Zitat Homma Y, Hayabuchi Y, Terada T et al (2018) Early diastolic left ventricular relaxation in normal neonates is influenced by ventricular stiffness and longitudinal systolic function. Int Heart J 59:149–153CrossRef Homma Y, Hayabuchi Y, Terada T et al (2018) Early diastolic left ventricular relaxation in normal neonates is influenced by ventricular stiffness and longitudinal systolic function. Int Heart J 59:149–153CrossRef
15.
Zurück zum Zitat Mori K, Nakagawa R, Nii M et al (2004) Pulsed wave Doppler tissue echocardiography assessment of the long axis function of the right and left ventricles during the early neonatal period. Heart 90:175–180CrossRef Mori K, Nakagawa R, Nii M et al (2004) Pulsed wave Doppler tissue echocardiography assessment of the long axis function of the right and left ventricles during the early neonatal period. Heart 90:175–180CrossRef
16.
Zurück zum Zitat Nagasawa H (2010) Novel regression equations of left ventricular dimensions in infants less than 1 year of age and premature neonates obtained from echocardiographic examination. Cardiol Young 20:526–531CrossRef Nagasawa H (2010) Novel regression equations of left ventricular dimensions in infants less than 1 year of age and premature neonates obtained from echocardiographic examination. Cardiol Young 20:526–531CrossRef
17.
Zurück zum Zitat Eidem BW, McMahon CJ, Cohen RR et al (2004) Impact of cardiac growth on Doppler tissue imaging velocities: a study in healthy children. J Am Soc Echocardiogr 17:212–221CrossRef Eidem BW, McMahon CJ, Cohen RR et al (2004) Impact of cardiac growth on Doppler tissue imaging velocities: a study in healthy children. J Am Soc Echocardiogr 17:212–221CrossRef
18.
Zurück zum Zitat Pena JL, da Silva MG, Faria SC et al (2009) Quantification of regional left and right ventricular deformation indices in healthy neonates by using strain rate and strain imaging. J Am Soc Echocardiogr 22:369–375CrossRef Pena JL, da Silva MG, Faria SC et al (2009) Quantification of regional left and right ventricular deformation indices in healthy neonates by using strain rate and strain imaging. J Am Soc Echocardiogr 22:369–375CrossRef
19.
Zurück zum Zitat Nestaas E, Schubert U, de Boode WP et al (2018) Tissue Doppler velocity imaging and event timings in neonates: a guide to image acquisition, measurement, interpretation, and reference values. Pediatr Res 84:18–29CrossRef Nestaas E, Schubert U, de Boode WP et al (2018) Tissue Doppler velocity imaging and event timings in neonates: a guide to image acquisition, measurement, interpretation, and reference values. Pediatr Res 84:18–29CrossRef
20.
Zurück zum Zitat Ma CY, Liu S, Zhang Q et al (2014) Calibration of the normal cutoff values of systolic dyssynchrony of the left ventricular synchronicity in normal subjects using real-time 3-dimensional echocardiography and the effects of age and heart rate. Cell Biochem Biophys 69:115–121CrossRef Ma CY, Liu S, Zhang Q et al (2014) Calibration of the normal cutoff values of systolic dyssynchrony of the left ventricular synchronicity in normal subjects using real-time 3-dimensional echocardiography and the effects of age and heart rate. Cell Biochem Biophys 69:115–121CrossRef
21.
Zurück zum Zitat de Boode WP, van der Lee R, Horsberg Eriksen B et al (2018) The role of neonatologist performed echocardiography in the assessment and management of neonatal shock. Pediatr Res 84:57–67CrossRef de Boode WP, van der Lee R, Horsberg Eriksen B et al (2018) The role of neonatologist performed echocardiography in the assessment and management of neonatal shock. Pediatr Res 84:57–67CrossRef
22.
Zurück zum Zitat Boettler P, Hartmann M, Watzl K et al (2005) Heart rate effects on strain and strain rate in healthy children. J Am Soc Echocardiogr 18:1121–1130CrossRef Boettler P, Hartmann M, Watzl K et al (2005) Heart rate effects on strain and strain rate in healthy children. J Am Soc Echocardiogr 18:1121–1130CrossRef
23.
Zurück zum Zitat Lorch SM, Ludomirsky A, Singh GK (2008) Maturational and growth-related changes in left ventricular longitudinal strain and strain rate measured by two-dimensional speckle tracking echocardiography in healthy pediatric population. J Am Soc Echocardiogr 21:1207–1215CrossRef Lorch SM, Ludomirsky A, Singh GK (2008) Maturational and growth-related changes in left ventricular longitudinal strain and strain rate measured by two-dimensional speckle tracking echocardiography in healthy pediatric population. J Am Soc Echocardiogr 21:1207–1215CrossRef
24.
Zurück zum Zitat Liu BH, Zhu XM, Li GJ et al (2009) Quantitative assessment of left ventricular segmental motion synchronicity in patients of heart failure using illustration of the bull eye with real-time three-dimensional echocardiography. Chin J Med Imaging Technol 25:1407–1410 Liu BH, Zhu XM, Li GJ et al (2009) Quantitative assessment of left ventricular segmental motion synchronicity in patients of heart failure using illustration of the bull eye with real-time three-dimensional echocardiography. Chin J Med Imaging Technol 25:1407–1410
25.
Zurück zum Zitat Natakanishi T, Okuda H, Kamata K et al (1987) Development of myocardial contractile system in the fetal rabbit. Pediatr Res 22:201–207CrossRef Natakanishi T, Okuda H, Kamata K et al (1987) Development of myocardial contractile system in the fetal rabbit. Pediatr Res 22:201–207CrossRef
Metadaten
Titel
Evaluating Left Ventricular Systolic Synchronicity with Real-Time 3D Echocardiography in Newborns
verfasst von
Min Xu
Weidong Ren
Feng Xiong
Shuzhen Wang
Lijuan Zhang
Chunxia Liu
Xiaofeng Huang
Yali Lei
Publikationsdatum
15.04.2021
Verlag
Springer US
Erschienen in
Pediatric Cardiology / Ausgabe 5/2021
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-021-02601-5

Weitere Artikel der Ausgabe 5/2021

Pediatric Cardiology 5/2021 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.