Evaluating the effect of low-level laser therapy on pain induced by orthodontic separation: a randomized split-mouth clinical trial

verfasst von: Seema Gupta, Sachin Ahuja, Eenal Bhambri, Surbhi Sharma, Rohini Sharma, Himanshu Kalia

Erschienen in: Lasers in Dental Science | Ausgabe 4/2018

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Pain is the most common sequela reported by patients undergoing orthodontic treatment. It is a prime concern as despite the desire, the orthodontic treatment is refuted by most patients because of the associated pain and discomfort. Recently, there is an abundance of research going on in the field of orthodontics regarding the causes of orthodontic pain and the measures that could efficiently reduce it. One such method is the administration of lasers to reduce the intensity of pain. Therefore, the aim of this study was to assess the effect of low-level laser therapy on spontaneous pain and pain on chewing caused by elastomeric separators.

Method

Forty patients were randomly selected for this single-blind, split-mouth study. Elastomeric separators were placed mesial and distal to the permanent first molars in all the four quadrants. The arches were divided into experimental and control sides. The experimental side was treated with low-level laser therapy on two points on the buccal and lingual mucosa for 20 s each, with a 940-nm gallium-aluminum-arsenic diode laser on continuous mode and power set at 200 mW. The other side received placebo laser therapy without turning on the laser. A visual analogue scale was used to assess the intensity of spontaneous pain and pain on chewing, and the subjects were asked to mark the pain scores in a questionnaire given to them at different time intervals. The independent samples t test and analysis of variance with the post hoc Tukey test was used to analyze the results.

Results

The subjects reported less intensity of pain on chewing as well as spontaneous pain at the sites which were given low-level laser therapy as compared to the placebo side. The difference between the pain intensity on the low-level laser therapy side and placebo side was found to be statistically significant (p ≤ 0.05).

Conclusion

A single dose of low-level laser therapy is an effective modality in significantly reducing the intensity of both spontaneous and pain on chewing caused after the placement of elastomeric separators.
Literatur
1.
Zurück zum Zitat Turhani D, Scheriau M, Kapral D, Benesch T, Jonke E, Bantleon HP (2006) Pain relief by single low-level laser irradiation in orthodontic patients undergoing fixed appliance therapy. Am J Orthod Dentofac Orthop 130:371–377CrossRef Turhani D, Scheriau M, Kapral D, Benesch T, Jonke E, Bantleon HP (2006) Pain relief by single low-level laser irradiation in orthodontic patients undergoing fixed appliance therapy. Am J Orthod Dentofac Orthop 130:371–377CrossRef
2.
Zurück zum Zitat Deshpande P, Patil K, Mahima VG, Shivalinga BM, Suchetha M, Ranjan A (2016) Low-level laser therapy for alleviation of pain from fixed orthodontic appliance therapy: a randomized controlled trial. J Adv Clin Res Insights 3:43–46CrossRef Deshpande P, Patil K, Mahima VG, Shivalinga BM, Suchetha M, Ranjan A (2016) Low-level laser therapy for alleviation of pain from fixed orthodontic appliance therapy: a randomized controlled trial. J Adv Clin Res Insights 3:43–46CrossRef
3.
Zurück zum Zitat Abtahi SM, Mousavi SA, Shafaee H, Tanbakuchi B (2013) Effect of low-level laser therapy on dental pain induced by separator force in orthodontic treatment. Dent Res J 10:647–651 Abtahi SM, Mousavi SA, Shafaee H, Tanbakuchi B (2013) Effect of low-level laser therapy on dental pain induced by separator force in orthodontic treatment. Dent Res J 10:647–651
4.
Zurück zum Zitat Shi Q, Yang S, Jia F, Xu J (2015) Does low level laser therapy relieve the pain caused by the placement of the orthodontic separators? A meta-analysis. Head Face Med 11(1):28CrossRefPubMedPubMedCentral Shi Q, Yang S, Jia F, Xu J (2015) Does low level laser therapy relieve the pain caused by the placement of the orthodontic separators? A meta-analysis. Head Face Med 11(1):28CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Bergius M, Kiliaridis S, Berggren U (2000) Pain in orthodontics. A review and discussion of the literature. J Orofac Orthop 61(2):125–137CrossRefPubMed Bergius M, Kiliaridis S, Berggren U (2000) Pain in orthodontics. A review and discussion of the literature. J Orofac Orthop 61(2):125–137CrossRefPubMed
6.
Zurück zum Zitat Qamruddin I, Alam MK, Fida M, Khan AG (2016) Effect of a single dose of low-level laser therapy on spontaneous and chewing pain caused by elastomeric separators. Am J Orthod Dentofac Orthop 149(1):62–66CrossRef Qamruddin I, Alam MK, Fida M, Khan AG (2016) Effect of a single dose of low-level laser therapy on spontaneous and chewing pain caused by elastomeric separators. Am J Orthod Dentofac Orthop 149(1):62–66CrossRef
7.
Zurück zum Zitat Scheurer PA, Firestone AR, Burgin WB (1996) Perception of pain as a result of orthodontic treatment with fixed appliances. Eur J Orthod 18:349–357CrossRefPubMed Scheurer PA, Firestone AR, Burgin WB (1996) Perception of pain as a result of orthodontic treatment with fixed appliances. Eur J Orthod 18:349–357CrossRefPubMed
8.
Zurück zum Zitat Ngan P, Kess B, Wilson S (1989) Perception of discomfort by patients undergoing orthodontic treatment. Am J Orthod Dentofac Orthop 96:47–53CrossRef Ngan P, Kess B, Wilson S (1989) Perception of discomfort by patients undergoing orthodontic treatment. Am J Orthod Dentofac Orthop 96:47–53CrossRef
9.
Zurück zum Zitat Mester E, Szende B (1967) Influence of laser on hair growth of mice. Kiserl Orvostud 19:628–631 Mester E, Szende B (1967) Influence of laser on hair growth of mice. Kiserl Orvostud 19:628–631
10.
Zurück zum Zitat Oltra-Arimon D, Spain-Tost AJ, Berini-Aytés L, Gay-Escoda C (2004) Low-power laser applications in dentistry. RCOE 9(5):517–524CrossRef Oltra-Arimon D, Spain-Tost AJ, Berini-Aytés L, Gay-Escoda C (2004) Low-power laser applications in dentistry. RCOE 9(5):517–524CrossRef
11.
Zurück zum Zitat Eslamian L, Borzabadi-Farahani A, Hassanzadeh-Azhiri A, Badiee MR, Fekrazad R. The effect of 810-nm low-level laser therapy on pain caused by orthodontic elastomeric separators. Lasers Med Sci 2014;29:559–564. 22CrossRefPubMed Eslamian L, Borzabadi-Farahani A, Hassanzadeh-Azhiri A, Badiee MR, Fekrazad R. The effect of 810-nm low-level laser therapy on pain caused by orthodontic elastomeric separators. Lasers Med Sci 2014;29:559–564. 22CrossRefPubMed
12.
Zurück zum Zitat Marini I, Bartolucci ML, Bortolotti F, Innocenti G, Gatto MR, Bonetti GA (2015) The effect of diode superpulsed low-level laser therapy on experimental orthodontic pain caused by elastomeric separators: a randomized controlled clinical trial. Lasers Med Sci 30:35–41CrossRefPubMed Marini I, Bartolucci ML, Bortolotti F, Innocenti G, Gatto MR, Bonetti GA (2015) The effect of diode superpulsed low-level laser therapy on experimental orthodontic pain caused by elastomeric separators: a randomized controlled clinical trial. Lasers Med Sci 30:35–41CrossRefPubMed
13.
Zurück zum Zitat Farias RD, Closs LQ, Miguens SAQ Jr (2016) Evaluation of the use of low-level laser therapy in pain control in orthodontic patients: a randomized split-mouth clinical trial. Angle Orthod 86(2):193–198CrossRefPubMed Farias RD, Closs LQ, Miguens SAQ Jr (2016) Evaluation of the use of low-level laser therapy in pain control in orthodontic patients: a randomized split-mouth clinical trial. Angle Orthod 86(2):193–198CrossRefPubMed
14.
Zurück zum Zitat Lim HM, Lew KK, Tay DK (1995) A clinical investigation of the efficacy of low level laser therapy in reducing orthodontic post adjustment pain. Am J Orthod Dentofac Orthop 108:614–622CrossRef Lim HM, Lew KK, Tay DK (1995) A clinical investigation of the efficacy of low level laser therapy in reducing orthodontic post adjustment pain. Am J Orthod Dentofac Orthop 108:614–622CrossRef
15.
Zurück zum Zitat Zawawi KH (2014) Acceptance of orthodontic miniscrews as temporary anchorage devices. Patient Prefer Adherence 30(8):933–937CrossRef Zawawi KH (2014) Acceptance of orthodontic miniscrews as temporary anchorage devices. Patient Prefer Adherence 30(8):933–937CrossRef
16.
Zurück zum Zitat Farivar S, Malekshahabi T, Shiari R (2014) Biological effects of low level laser therapy. J Lasers Med Sci 5(2):58–62PubMedPubMedCentral Farivar S, Malekshahabi T, Shiari R (2014) Biological effects of low level laser therapy. J Lasers Med Sci 5(2):58–62PubMedPubMedCentral
17.
Zurück zum Zitat Doshi-Mehta G, Bhad-Patil WA (2012 Mar 31) Efficacy of low-intensity laser therapy in reducing treatment time and orthodontic pain: a clinical investigation. Am J Orthod Dentofac Orthop 141(3):289–297CrossRef Doshi-Mehta G, Bhad-Patil WA (2012 Mar 31) Efficacy of low-intensity laser therapy in reducing treatment time and orthodontic pain: a clinical investigation. Am J Orthod Dentofac Orthop 141(3):289–297CrossRef
18.
Zurück zum Zitat Rosas S, Paço M, Lemos C, Pinho T (2017) Comparison between the Visual Analog Scale and the Numerical Rating Scale in the perception of esthetics and pain. Int Orthod 15(4):543–560PubMed Rosas S, Paço M, Lemos C, Pinho T (2017) Comparison between the Visual Analog Scale and the Numerical Rating Scale in the perception of esthetics and pain. Int Orthod 15(4):543–560PubMed
19.
Zurück zum Zitat Chow R, Armati P, Laakso EL, Bjordal JM, Baxter GD (2011) Inhibitory effects of laser irradiation on peripheral mammalian nerves and relevance to analgesic effects: a systematic review. Photomed Laser Surg 29(6):356–381CrossRef Chow R, Armati P, Laakso EL, Bjordal JM, Baxter GD (2011) Inhibitory effects of laser irradiation on peripheral mammalian nerves and relevance to analgesic effects: a systematic review. Photomed Laser Surg 29(6):356–381CrossRef
20.
Zurück zum Zitat Laakso EL, Cabot PJ (2005) Nociceptive scores and endorphin-containing cells reduced by low-level laser therapy (LLLT) in inflamed paws of Wistar rat. Photomed Laser Surg 23(1):32–35CrossRefPubMed Laakso EL, Cabot PJ (2005) Nociceptive scores and endorphin-containing cells reduced by low-level laser therapy (LLLT) in inflamed paws of Wistar rat. Photomed Laser Surg 23(1):32–35CrossRefPubMed
21.
Zurück zum Zitat Asiry MA, Albarakati SF, Al-Marwan MS, Al-Shammari RR (2014) Perception of pain and discomfort from elastomeric separators in Saudi adolescents. Saudi Med J 35:504–507PubMed Asiry MA, Albarakati SF, Al-Marwan MS, Al-Shammari RR (2014) Perception of pain and discomfort from elastomeric separators in Saudi adolescents. Saudi Med J 35:504–507PubMed
22.
Zurück zum Zitat Kapoor P, Singh H, Ghai GS, Ghai GK (2013) Perception of pain and discomfort from three types of orthodontic separators. Indian J Dent Sci 5:9–13 Kapoor P, Singh H, Ghai GS, Ghai GK (2013) Perception of pain and discomfort from three types of orthodontic separators. Indian J Dent Sci 5:9–13
Metadaten
Titel
Evaluating the effect of low-level laser therapy on pain induced by orthodontic separation: a randomized split-mouth clinical trial
verfasst von
Seema Gupta
Sachin Ahuja
Eenal Bhambri
Surbhi Sharma
Rohini Sharma
Himanshu Kalia
Publikationsdatum
16.08.2018
Verlag
Springer International Publishing
Erschienen in
Lasers in Dental Science / Ausgabe 4/2018
Elektronische ISSN: 2367-2587
DOI
https://doi.org/10.1007/s41547-018-0040-5

Weitere Artikel der Ausgabe 4/2018

Lasers in Dental Science 4/2018 Zur Ausgabe

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.