Evaluation of a Novel Integrated Sensor System for Synchronous Measurement of Cardiac Vibrations and Cardiac Potentials

verfasst von: Yindar Chuo, Kouhyar Tavakolian, Bozena Kaminska

Erschienen in: Journal of Medical Systems | Ausgabe 4/2011

Einloggen, um Zugang zu erhalten

Abstract

The measurement of human body vibrations as a result of heart beating, simultaneously with cardiac potentials have been demonstrated in past studies to bring additional value to diagnostic cardiology through the detection of irregularities in the mechanical movement of the heart. The equipment currently available to the medical community is either large and bulky or difficult to synchronize. To address this problem, a novel integrated sensor system has been developed to record cardiac vibration and cardiac potential simultaneously and synchronously from a single compact site on the chest. The developed sensor system is lightweight, small in size, and suitable for mounting on active moving patients. The sensor is evaluated for its adequacy in measuring cardiac vibrations and potentials. In this evaluation, 45 independent signal recording are studied from 15 volunteers, and the morphology of the recorded signals are analyzed qualitatively (by visual inspection) and quantitatively (by computational methods) against larger devices used in established cardiac vibration studies (reference devices). It is found that the cardiac vibration signals acquired by the integrated sensor has 92.37% and 81.76% identically identifiable systolic and diastolic cardiac complexes, respectively, when compared to the cardiac vibration signals recorded simultaneously from the reference device. Further, the cardiac potential signals acquired by the integrated sensor show a high correlation coefficient of 0.8912 and a high estimated signal-to-noise-ratio of 22.00 dB when compared to the reference electrocardiograph (non-standard leads) acquired through a common clinical machine. The results suggest that the tiny, wearable, integrated sensor system that synchronously measures cardiac vibrations and cardiac potentials may be practical for use as an alternative or assistive cardiac diagnostic tool.
Literatur
1.
Zurück zum Zitat McKay, W., Gregson, P., McKay, B., and Militzer, J., Sternal acceleration ballistocardiography and arterial pressure wave analysis to determine stroke volume. Clin. Invest. Med. 22 (1)4–14, 1999. McKay, W., Gregson, P., McKay, B., and Militzer, J., Sternal acceleration ballistocardiography and arterial pressure wave analysis to determine stroke volume. Clin. Invest. Med. 22 (1)4–14, 1999.
2.
Zurück zum Zitat Salerno, D., and Zanetti, J., Seismocardiography: A new technique for recording cardiac vibrations. J. Cardiovasc Technol. 9:111–117, 1990. Salerno, D., and Zanetti, J., Seismocardiography: A new technique for recording cardiac vibrations. J. Cardiovasc Technol. 9:111–117, 1990.
3.
Zurück zum Zitat Tavakolian, K., Zadeh, F.M., Chuo, Y., Vaseghi, A., and Kaminska, B., Development of a novel contactless mechanocardiograph device. Int. J. Telemed. Appl. 436870, 2008. Tavakolian, K., Zadeh, F.M., Chuo, Y., Vaseghi, A., and Kaminska, B., Development of a novel contactless mechanocardiograph device. Int. J. Telemed. Appl. 436870, 2008.
4.
Zurück zum Zitat Tavakolian, K., Vaseghi, A., and Kaminska, B., Improvement of ballistocardiogram processing by inclusion of respiration information. J. Physiol. Meas. IOP. 29 (7)771–781, 2008.CrossRef Tavakolian, K., Vaseghi, A., and Kaminska, B., Improvement of ballistocardiogram processing by inclusion of respiration information. J. Physiol. Meas. IOP. 29 (7)771–781, 2008.CrossRef
5.
Zurück zum Zitat Crow, S. R., Hannan, P., Jacobs, D., Hedquist, L., and Salerno, D. M., Relationship between seismocardiogram and echocardiogram for events in the cardiac cycle. Am. J. Noninvas. Cardiol. 8:39–46, 1994. Crow, S. R., Hannan, P., Jacobs, D., Hedquist, L., and Salerno, D. M., Relationship between seismocardiogram and echocardiogram for events in the cardiac cycle. Am. J. Noninvas. Cardiol. 8:39–46, 1994.
6.
Zurück zum Zitat Castiglioni, P., Faini, A., Parati, G., Di Rienzo, M., Wearable seismocardiography. In: Proc 29th Ann Intl Conf IEEE EMBS, pp 3954–3957, 2007. Castiglioni, P., Faini, A., Parati, G., Di Rienzo, M., Wearable seismocardiography. In: Proc 29th Ann Intl Conf IEEE EMBS, pp 3954–3957, 2007.
7.
Zurück zum Zitat Starr, I., and Wood, E. C., Twenty-year studies with the ballistocardiograph, the relation between the amplitude of the first record of ‘healthy’ adults and eventual mortality and morbidity form heart disease. Circulation. 23:714–732, 1961. Starr, I., and Wood, E. C., Twenty-year studies with the ballistocardiograph, the relation between the amplitude of the first record of ‘healthy’ adults and eventual mortality and morbidity form heart disease. Circulation. 23:714–732, 1961.
8.
Zurück zum Zitat Eblen-Zajjur, A., A simple ballistocardiography system for medical cardiovascular physiology course. Adv. Physiol. Educ. 27:224–229, 2003.CrossRef Eblen-Zajjur, A., A simple ballistocardiography system for medical cardiovascular physiology course. Adv. Physiol. Educ. 27:224–229, 2003.CrossRef
9.
Zurück zum Zitat Elliott, R. V., Acceleration ballistocardiography: Design, construction, and application of a new instrument. Circulation. 9:281–291, 1954. Elliott, R. V., Acceleration ballistocardiography: Design, construction, and application of a new instrument. Circulation. 9:281–291, 1954.
10.
Zurück zum Zitat Starr, I., and Noordergraaf, A., Ballistocardiography in Cardiovascular Research. Lippincott, Philadelphia, 1967. Starr, I., and Noordergraaf, A., Ballistocardiography in Cardiovascular Research. Lippincott, Philadelphia, 1967.
11.
Zurück zum Zitat Chuo, Y., and Kaminska, B., Multiparameter single locus integrated multilayer polymer microsensor system. BIODEVICES. 1:36–43, 2008. Chuo, Y., and Kaminska, B., Multiparameter single locus integrated multilayer polymer microsensor system. BIODEVICES. 1:36–43, 2008.
12.
Zurück zum Zitat Chuo, Y., and Kaminska, B., Sensor layer of a multiparameter single-point integrated system. IEEE Trans. Biomed. Circuits Syst. 3 (4)229–240, 2009.CrossRef Chuo, Y., and Kaminska, B., Sensor layer of a multiparameter single-point integrated system. IEEE Trans. Biomed. Circuits Syst. 3 (4)229–240, 2009.CrossRef
13.
Zurück zum Zitat Afonso, V. X., Tompkins, W. J., Nguyen, T. Q., and Luo, S., ECG beat detection using filter banks. IEEE TBME. 46:192–202, 1999. Afonso, V. X., Tompkins, W. J., Nguyen, T. Q., and Luo, S., ECG beat detection using filter banks. IEEE TBME. 46:192–202, 1999.
14.
Zurück zum Zitat Bershad, N. J., and Rockmore, A. J., On estimating signal to noise ratio using the sample correlation coefficient. IEEE Trans. Inf. Theory. 20:112–113, 1974.MATHCrossRef Bershad, N. J., and Rockmore, A. J., On estimating signal to noise ratio using the sample correlation coefficient. IEEE Trans. Inf. Theory. 20:112–113, 1974.MATHCrossRef
Metadaten
Titel
Evaluation of a Novel Integrated Sensor System for Synchronous Measurement of Cardiac Vibrations and Cardiac Potentials
verfasst von
Yindar Chuo
Kouhyar Tavakolian
Bozena Kaminska
Publikationsdatum
01.08.2011
Verlag
Springer US
Erschienen in
Journal of Medical Systems / Ausgabe 4/2011
Print ISSN: 0148-5598
Elektronische ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-009-9380-8

Weitere Artikel der Ausgabe 4/2011

Journal of Medical Systems 4/2011 Zur Ausgabe