Skip to main content
Erschienen in: Neuroradiology 1/2019

01.12.2018 | Spinal Neuroradiology

Evaluation of a novel, patient-mounted system for CT-guided needle navigation—an ex vivo study

verfasst von: Anna Mokry, Florian Willmitzer, Rafael Hostettler, Henning Richter, Patrick Kircher, Sibylle Kneissl, Stephan Wetzel

Erschienen in: Neuroradiology | Ausgabe 1/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To describe the features of a novel patient-mounted system for CT-guided needle navigation, the Puncture Cube System (PCS), and to evaluate the accuracy and efficiency of the PCS by (a) applying numerical simulations and (b) by conducting punctures using the system in comparison to punctures using the free-hand method (FHM).

Methods

The PCS consists of a self-adhesive cube that is attached to the patient, with multiple through-holes in the upper and lower template plate and dedicated software that, using a computer vision algorithm, recognizes the cube in a planning scan. The target in the image dataset is connected by a line, here “virtual needle,” which passes through the cube. For any chosen path of the virtual needle, the entry points for the needle into the cube are displayed by the software for the upper and lower template on-the-fly.
The possible exactness of the system was investigated by using numerical simulations. Next, 72 punctures were performed by 6 interventionists using a phantom to compare for accuracy, time requirement, and number of CT scans for punctures with the system to the FHM ex vivo (phantom study).

Results

The theoretical precision to arrive at targets increased with the distance of the target but remained low. The mean error for targets up to 20 cm below the lower plate was computed to be well below 0.5 mm, and the worst-case error stayed below 1.3 mm.
Compared to a conventional free-hand procedure, the use of the navigation system resulted in a statistically significantly improved accuracy (3.4 mm ± 2.3 mm versus FHM 4.9 mm ± 3.2 mm) and overall lower intervention time (168 s ± 28.5 s versus FHM 200 s ± 44.8 s). Furthermore, the number of CT scans was reduced to 2.3 versus FHM 2.8).

Conclusion

The PCS is a promising technique to improve accuracy and reduce intervention time in CT-guided needle navigations compared to the FHM.
Literatur
2.
Zurück zum Zitat Begemann PG (2009) CT-guided interventions—indications, technique, pitfalls. In: Mahnken AH, Ricke J (eds) CT- and MR-guided interventions in radiology. Springer Berlin Heidelberg, Berlin, pp 11–20CrossRef Begemann PG (2009) CT-guided interventions—indications, technique, pitfalls. In: Mahnken AH, Ricke J (eds) CT- and MR-guided interventions in radiology. Springer Berlin Heidelberg, Berlin, pp 11–20CrossRef
3.
Zurück zum Zitat Hoeltje J, Bruening R, Kastler B et al (2013) Interventional pain managment. In: Mahnken AH, Wilhelm KE, Ricke J (eds) CT- and MR-guided interventions in radiology. Springer Berlin Heidelberg, Berlin, pp 363–419CrossRef Hoeltje J, Bruening R, Kastler B et al (2013) Interventional pain managment. In: Mahnken AH, Wilhelm KE, Ricke J (eds) CT- and MR-guided interventions in radiology. Springer Berlin Heidelberg, Berlin, pp 363–419CrossRef
6.
Zurück zum Zitat Loizides A, Peer S, Plaikner M et al (2011) Ultrasound-guided injections in the lumbar spine. Med Ultrason 13(1):54–58PubMed Loizides A, Peer S, Plaikner M et al (2011) Ultrasound-guided injections in the lumbar spine. Med Ultrason 13(1):54–58PubMed
11.
Zurück zum Zitat Putzer D, Arco D, Schamberger B, Schanda F, Mahlknecht J, Widmann G, Schullian P, Jaschke W, Bale R (2016) Comparison of two electromagnetic navigation systems for CT-guided punctures: a phantom study (Elektromagnetische Navigationssysteme im Vergleich: CT-gezielte Punktionen an einem phantom). Rofo 188(5):470–478. https://doi.org/10.1055/s-0042-103691 CrossRefPubMed Putzer D, Arco D, Schamberger B, Schanda F, Mahlknecht J, Widmann G, Schullian P, Jaschke W, Bale R (2016) Comparison of two electromagnetic navigation systems for CT-guided punctures: a phantom study (Elektromagnetische Navigationssysteme im Vergleich: CT-gezielte Punktionen an einem phantom). Rofo 188(5):470–478. https://​doi.​org/​10.​1055/​s-0042-103691 CrossRefPubMed
Metadaten
Titel
Evaluation of a novel, patient-mounted system for CT-guided needle navigation—an ex vivo study
verfasst von
Anna Mokry
Florian Willmitzer
Rafael Hostettler
Henning Richter
Patrick Kircher
Sibylle Kneissl
Stephan Wetzel
Publikationsdatum
01.12.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Neuroradiology / Ausgabe 1/2019
Print ISSN: 0028-3940
Elektronische ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-018-2107-0

Weitere Artikel der Ausgabe 1/2019

Neuroradiology 1/2019 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.