Skip to main content
Erschienen in: Clinical Neuroradiology 2/2018

11.12.2016 | Original Article

Evaluation of Cerebral Hyperperfusion After Carotid Artery Stenting Using C‑Arm CT Measurements of Cerebral Blood Volume

verfasst von: Michio Fujimoto, Hiroshi Itokawa, Masao Moriya, Noriyoshi Okamoto, Jinichi Sasanuma

Erschienen in: Clinical Neuroradiology | Ausgabe 2/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Hyperperfusion syndrome (HPS) after carotid artery stenting (CAS) causes serious symptoms; therefore, early evaluation after CAS is considered to be important. Measurement of cerebral blood volume using C‑arm computed tomography (C-arm CBV) has recently become possible. Here, the usefulness of C‑arm CBV for the evaluation of hyperperfusion was investigated.

Methods

C-arm CBV was measured before and immediately after CAS in 30 patients. The regions of interest (ROI) were set in the bilateral middle cerebral artery perfused regions, and the affected/healthy side ratio of measured C‑arm CBV (CBV ratios) was determined to evaluate cerebral perfusion. For comparing values before and after CAS, the CBV ratio increase rate (postoperative CBV ratios/preoperative CBV ratios) was also determined.

Results

C-arm CBV was successfully measured in 30 patients. Intracerebral hemorrhage (ICH) was detected in 3 patients, and no other patient had hyperperfusion syndrome. In the patients who developed ICH, postoperative C‑arm CBV on the affected side was high, and a marked increase was confirmed in the postoperative CBV ratios. Postoperative CBV ratios were 1.03 ± 0.40 and 1.45 ± 0.68 in the non-ICH and ICH groups, and CBV ratio increase rates were 2.7 ± 24.0% and 28.5 ± 26.7% in the non-ICH and ICH groups, respectively; these differences were statistically significant (P < 0.01).

Conclusion

C-arm CT allows CBV measurements immediately after CAS without requiring transport of the patient out of the angiography room, and it may enable the evaluation of hyperperfusion before and after CAS.
Literatur
1.
Zurück zum Zitat Brott TG, Hobson RW 2nd, Howard G, Roubin GS, Clark WM, Brooks W, Mackey A, Hill MD, Leimgruber PP, Sheffet AJ, Howard VJ, Moore WS, Voeks JH, Hopkins LN, Cutlip DE, Cohen DJ, Popma JJ, Ferguson RD, Cohen SN, Blackshear JL, Silver FL, Mohr JP, Lal BK, Meschia JF, CREST Investigators. Stenting versus endarterectomy for treatment of carotid-artery Stenosis. N Engl J Med. 2010;363:11–23.CrossRefPubMedPubMedCentral Brott TG, Hobson RW 2nd, Howard G, Roubin GS, Clark WM, Brooks W, Mackey A, Hill MD, Leimgruber PP, Sheffet AJ, Howard VJ, Moore WS, Voeks JH, Hopkins LN, Cutlip DE, Cohen DJ, Popma JJ, Ferguson RD, Cohen SN, Blackshear JL, Silver FL, Mohr JP, Lal BK, Meschia JF, CREST Investigators. Stenting versus endarterectomy for treatment of carotid-artery Stenosis. N Engl J Med. 2010;363:11–23.CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Moulakakis KG, Mylonas SN, Sfyroeras GS, Andrikopoulos V. Hyperperfusion syndrome after carotid revascularization. J Vasc Surg. 2009;49:1060–8.CrossRefPubMed Moulakakis KG, Mylonas SN, Sfyroeras GS, Andrikopoulos V. Hyperperfusion syndrome after carotid revascularization. J Vasc Surg. 2009;49:1060–8.CrossRefPubMed
3.
Zurück zum Zitat van Mook WN, Rennenberg RJ, Schurink GW, van Oostenbrugge RJ, Mess WH, Hofman PA, de Leeuw PW. Cerebral hyperperfusion syndrome. Lancet Neurol. 2005;4:877–88.CrossRefPubMed van Mook WN, Rennenberg RJ, Schurink GW, van Oostenbrugge RJ, Mess WH, Hofman PA, de Leeuw PW. Cerebral hyperperfusion syndrome. Lancet Neurol. 2005;4:877–88.CrossRefPubMed
4.
Zurück zum Zitat Buczek J, Karliński M, Kobayashi A, Białek P, Członkowska A. Hyperperfusion syndrome after carotid endarterectomy and carotid stenting. Cerebrovasc Dis. 2013;35:531–7.CrossRefPubMed Buczek J, Karliński M, Kobayashi A, Białek P, Członkowska A. Hyperperfusion syndrome after carotid endarterectomy and carotid stenting. Cerebrovasc Dis. 2013;35:531–7.CrossRefPubMed
5.
Zurück zum Zitat Komoribayashi N, Ogasawara K, Kobayashi M, Saitoh H, Terasaki K, Inoue T, Ogawa A. Cerebral hyperperfusion after carotid endarterectomy is associated with preoperative hemodynamic impairment and intraoperative cerebral ischemia. J Cereb Blood Flow Metab. 2006;26:878–84.CrossRefPubMed Komoribayashi N, Ogasawara K, Kobayashi M, Saitoh H, Terasaki K, Inoue T, Ogawa A. Cerebral hyperperfusion after carotid endarterectomy is associated with preoperative hemodynamic impairment and intraoperative cerebral ischemia. J Cereb Blood Flow Metab. 2006;26:878–84.CrossRefPubMed
6.
Zurück zum Zitat Sundt TM Jr, Sharbrough FW, Piepgras DG, Kearns TP, Messick JM Jr, O’Fallon WM. Correlation of cerebral blood flow and electroencephalographic changes during carotid endarterectomy, with results of surgery and hemodynamics of cerebral ischemia. Mayo Clin Proc. 1981;56:533–43.PubMed Sundt TM Jr, Sharbrough FW, Piepgras DG, Kearns TP, Messick JM Jr, O’Fallon WM. Correlation of cerebral blood flow and electroencephalographic changes during carotid endarterectomy, with results of surgery and hemodynamics of cerebral ischemia. Mayo Clin Proc. 1981;56:533–43.PubMed
7.
Zurück zum Zitat Ogasawara K, Sakai N, Kuroiwa T, Hosoda K, Iihara K, Toyoda K, Sakai C, Nagata I, Ogawa A. Japanese society for treatment at neck in cerebrovascular disease study group. Intracranial hemorrhage associated with cerebral hyperperfusion syndrome following carotid endarterectomy and carotid artery stenting: Retrospective review of 4494 patients. J Neurosurg. 2007;107:1130–6.CrossRefPubMed Ogasawara K, Sakai N, Kuroiwa T, Hosoda K, Iihara K, Toyoda K, Sakai C, Nagata I, Ogawa A. Japanese society for treatment at neck in cerebrovascular disease study group. Intracranial hemorrhage associated with cerebral hyperperfusion syndrome following carotid endarterectomy and carotid artery stenting: Retrospective review of 4494 patients. J Neurosurg. 2007;107:1130–6.CrossRefPubMed
8.
Zurück zum Zitat Mordasini P, El-Koussy M, Brekenfeld C, Schroth G, Fischer U, Beck J, Gralla J. Applicability of tableside flat panel detector CT parenchymal cerebral blood volume measurement in neurovascular interventions: preliminary clinical experience. AJNR Am J Neuroradiol. 2012;33:154–8.CrossRefPubMed Mordasini P, El-Koussy M, Brekenfeld C, Schroth G, Fischer U, Beck J, Gralla J. Applicability of tableside flat panel detector CT parenchymal cerebral blood volume measurement in neurovascular interventions: preliminary clinical experience. AJNR Am J Neuroradiol. 2012;33:154–8.CrossRefPubMed
9.
Zurück zum Zitat Struffert T, Deuerling-Zheng Y, Kloska S, Engelhorn T, Boese J, Zellerhoff M, Schwab S, Doerfler A. Cerebral blood volume imaging by flat detector computed tomography in comparison to conventional multislice perfusion CT. Eur Radiol. 2011;21:882–9.CrossRefPubMed Struffert T, Deuerling-Zheng Y, Kloska S, Engelhorn T, Boese J, Zellerhoff M, Schwab S, Doerfler A. Cerebral blood volume imaging by flat detector computed tomography in comparison to conventional multislice perfusion CT. Eur Radiol. 2011;21:882–9.CrossRefPubMed
10.
Zurück zum Zitat Struffert T, Deuerling-Zheng Y, Kloska S, Engelhorn T, Strother CM, Kalender WA, Köhrmann M, Schwab S, Doerfler A. Flat detector CT in the evaluation of brain parenchyma, intracranial vasculature, and cerebral blood volume: A pilot study in patients with acute symptoms of cerebral ischemia. AJNR Am J Neuroradiol. 2010;31:1462–9.CrossRefPubMed Struffert T, Deuerling-Zheng Y, Kloska S, Engelhorn T, Strother CM, Kalender WA, Köhrmann M, Schwab S, Doerfler A. Flat detector CT in the evaluation of brain parenchyma, intracranial vasculature, and cerebral blood volume: A pilot study in patients with acute symptoms of cerebral ischemia. AJNR Am J Neuroradiol. 2010;31:1462–9.CrossRefPubMed
11.
Zurück zum Zitat Ahmed AS, Zellerhoff M, Strother CM, Pulfer KA, Redel T, Deuerling-Zheng Y, Royalty K, Consigny D, Niemann DB. C‑arm CT measurement of cerebral blood volume: An experimental study in canines. AJNR Am J Neuroradiol. 2009;30:917–22.CrossRefPubMed Ahmed AS, Zellerhoff M, Strother CM, Pulfer KA, Redel T, Deuerling-Zheng Y, Royalty K, Consigny D, Niemann DB. C‑arm CT measurement of cerebral blood volume: An experimental study in canines. AJNR Am J Neuroradiol. 2009;30:917–22.CrossRefPubMed
12.
Zurück zum Zitat Yang M, Wu J, Ma L, Pan L, Li J, Chen G, Struffert T, Sun Q, Beilner J, Deuerling-Zheng Y. The value of syngo DynaPBV Neuro during neuro-interventional hypotensive balloon occlusion test. Clin Neuroradiol. 2005;25:387–95.CrossRef Yang M, Wu J, Ma L, Pan L, Li J, Chen G, Struffert T, Sun Q, Beilner J, Deuerling-Zheng Y. The value of syngo DynaPBV Neuro during neuro-interventional hypotensive balloon occlusion test. Clin Neuroradiol. 2005;25:387–95.CrossRef
13.
Zurück zum Zitat Fiorella D, Turk A, Chaudry I, Turner R, Dunkin J, Roque C, Sarmiento M, Deuerling-Zheng Y, Denice CM, Baumeister M, Parker AT, Woo HH. A prospective, multicenter pilot study investigating the utility of flat detector derived parenchymal blood volume maps to estimate cerebral blood volume in stroke patients. J NeuroInterv Surg. 2014;6:451–6.CrossRefPubMed Fiorella D, Turk A, Chaudry I, Turner R, Dunkin J, Roque C, Sarmiento M, Deuerling-Zheng Y, Denice CM, Baumeister M, Parker AT, Woo HH. A prospective, multicenter pilot study investigating the utility of flat detector derived parenchymal blood volume maps to estimate cerebral blood volume in stroke patients. J NeuroInterv Surg. 2014;6:451–6.CrossRefPubMed
14.
Zurück zum Zitat Ogasawara K, Inoue T, Kobayashi M, Endo H, Yoshida K, Fukuda T, Terasaki K, Ogawa A. Cerebral hyperperfusion following carotid endarterectomy: diagnostic utility of intraoperative transcranial Doppler ultrasonography compared with single-photon emission computed tomography study. AJNR Am J Neuroradiol. 2005;26:252–7.PubMed Ogasawara K, Inoue T, Kobayashi M, Endo H, Yoshida K, Fukuda T, Terasaki K, Ogawa A. Cerebral hyperperfusion following carotid endarterectomy: diagnostic utility of intraoperative transcranial Doppler ultrasonography compared with single-photon emission computed tomography study. AJNR Am J Neuroradiol. 2005;26:252–7.PubMed
15.
Zurück zum Zitat Bley T, Strother CM, Pulfer K, Royalty K, Zellerhoff M, Deuerling-Zheng Y, Bender F, Consigny D, Yasuda R, Niemann D. C‑arm CT measurement of cerebral blood volume in ischemic stroke: An experimental study in canines. AJNR Am J Neuroradiol. 2010;31:536–40.CrossRefPubMed Bley T, Strother CM, Pulfer K, Royalty K, Zellerhoff M, Deuerling-Zheng Y, Bender F, Consigny D, Yasuda R, Niemann D. C‑arm CT measurement of cerebral blood volume in ischemic stroke: An experimental study in canines. AJNR Am J Neuroradiol. 2010;31:536–40.CrossRefPubMed
16.
Zurück zum Zitat Itokawa H, Moriya M, Fujimoto M, Itokawa H, Moriya M, Fujimoto M, Tomita Y, Okamoto N, Kikuchi N, Shibata N, Awane A. Evaluation of the aortic arch injection method using 50 % diluted-contrast medium for the measurement of cerebral blood volume with an angiographic C‑arm system. J Neuroendovasc Ther. 2013;7:145–55.CrossRef Itokawa H, Moriya M, Fujimoto M, Itokawa H, Moriya M, Fujimoto M, Tomita Y, Okamoto N, Kikuchi N, Shibata N, Awane A. Evaluation of the aortic arch injection method using 50 % diluted-contrast medium for the measurement of cerebral blood volume with an angiographic C‑arm system. J Neuroendovasc Ther. 2013;7:145–55.CrossRef
17.
Zurück zum Zitat Merckel LG, Van der Heijden J, Jongen LM, van Es HW, Prokop M, Waaijer A. Effect of stenting on cerebral CT perfusion in symptomatic and asymptomatic patients with carotid artery stenosis. AJNR Am J Neuroradiol. 2012;33:280–5.CrossRefPubMed Merckel LG, Van der Heijden J, Jongen LM, van Es HW, Prokop M, Waaijer A. Effect of stenting on cerebral CT perfusion in symptomatic and asymptomatic patients with carotid artery stenosis. AJNR Am J Neuroradiol. 2012;33:280–5.CrossRefPubMed
18.
Zurück zum Zitat Zhang Q, Wang B, Han J, Zhang Z, Sun Q, Beilner J, Shen C, He Z, Dai Y, Xu R. Feasibility study of perfusion imaging using flat detector CT with an intra-arterial injection protocol compared to conventional multi-slice perfusion CT with an intravenous injection protocol. Interv Neuroradiol. 2013;19:409–15.CrossRefPubMedPubMedCentral Zhang Q, Wang B, Han J, Zhang Z, Sun Q, Beilner J, Shen C, He Z, Dai Y, Xu R. Feasibility study of perfusion imaging using flat detector CT with an intra-arterial injection protocol compared to conventional multi-slice perfusion CT with an intravenous injection protocol. Interv Neuroradiol. 2013;19:409–15.CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Hosoda K, Kawaguchi T, Shibata Y, Kamei M, Kidoguchi K, Koyama J, Fujita S, Tamaki N. Cerebral vasoreactivity and internal carotid artery flow help to identify patients at risk for hyperperfusion after carotid endarterectomy. Stroke. 2001;32:1567–73.CrossRefPubMed Hosoda K, Kawaguchi T, Shibata Y, Kamei M, Kidoguchi K, Koyama J, Fujita S, Tamaki N. Cerebral vasoreactivity and internal carotid artery flow help to identify patients at risk for hyperperfusion after carotid endarterectomy. Stroke. 2001;32:1567–73.CrossRefPubMed
20.
Zurück zum Zitat Chang CH, Chang TY, Chang YJ, Huang KL, Chin SC, Ryu SJ, Yang TC, Lee TH. The role of perfusion computed tomography in the prediction of cerebral hyperperfusion syndrome. PLOS ONE. 2011;6:e10886. Chang CH, Chang TY, Chang YJ, Huang KL, Chin SC, Ryu SJ, Yang TC, Lee TH. The role of perfusion computed tomography in the prediction of cerebral hyperperfusion syndrome. PLOS ONE. 2011;6:e10886.
22.
Zurück zum Zitat Qureshi AI, Luft AR, Sharma M, Janardhan V, Lopes DK, Khan J, Guterman LR, Hopkins LN. Frequency and determinants of postprocedural hemodynamic instability after carotid angioplasty and stenting. Stroke. 1999;30:2086–93.CrossRefPubMed Qureshi AI, Luft AR, Sharma M, Janardhan V, Lopes DK, Khan J, Guterman LR, Hopkins LN. Frequency and determinants of postprocedural hemodynamic instability after carotid angioplasty and stenting. Stroke. 1999;30:2086–93.CrossRefPubMed
23.
Zurück zum Zitat Nagata S, Kazekawa K, Aikawa H, Tsutsumi M, Kodama T, Iko M, Nii K, Matsubara S, Go Y, Tanaka A. Hemodynamic stability under general anesthesia in carotid artery stenting. Radiat Med. 2005;23:427–31.PubMed Nagata S, Kazekawa K, Aikawa H, Tsutsumi M, Kodama T, Iko M, Nii K, Matsubara S, Go Y, Tanaka A. Hemodynamic stability under general anesthesia in carotid artery stenting. Radiat Med. 2005;23:427–31.PubMed
24.
Zurück zum Zitat Abou-Chebl A, Reginelli J, Bajzer CT, Yadav JS. Intensive treatment of hypertension decreases the risk of hypertension and intracerebral hemorrhage following carotid artery stenting. Catheter Cardiovasc Interv. 2007;69:690–6.CrossRefPubMed Abou-Chebl A, Reginelli J, Bajzer CT, Yadav JS. Intensive treatment of hypertension decreases the risk of hypertension and intracerebral hemorrhage following carotid artery stenting. Catheter Cardiovasc Interv. 2007;69:690–6.CrossRefPubMed
Metadaten
Titel
Evaluation of Cerebral Hyperperfusion After Carotid Artery Stenting Using C‑Arm CT Measurements of Cerebral Blood Volume
verfasst von
Michio Fujimoto
Hiroshi Itokawa
Masao Moriya
Noriyoshi Okamoto
Jinichi Sasanuma
Publikationsdatum
11.12.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Neuroradiology / Ausgabe 2/2018
Print ISSN: 1869-1439
Elektronische ISSN: 1869-1447
DOI
https://doi.org/10.1007/s00062-016-0552-x

Weitere Artikel der Ausgabe 2/2018

Clinical Neuroradiology 2/2018 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.