Skip to main content
Erschienen in: Clinical Oral Investigations 2/2016

01.03.2016 | Original Article

Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial

verfasst von: Danush Ahrberg, Hans Christoph Lauer, Martin Ahrberg, Paul Weigl

Erschienen in: Clinical Oral Investigations | Ausgabe 2/2016

Einloggen, um Zugang zu erhalten

Abstract

Objectives

The aim of this clinical trial was to evaluate the marginal and internal fit of CAD/CAM fabricated zirconia crowns and three-unit fixed dental prostheses (FDPs) resulting from direct versus indirect digitalization. The efficiency of both methods was analyzed.

Materials and methods

In 25 patients, 17 single crowns and eight three-unit FDPs were fabricated with all-ceramic zirconia using CAD/CAM technology. Each patient underwent two different impression methods; a computer-aided impression with Lava C.O.S. (CAI) and a conventional polyether impression with Impregum pent soft (CI). The working time for each group was recorded. Before insertion, the marginal and internal fit was recorded using silicone replicas of the frameworks. Each sample was cut into four sections and evaluated at four sites (marginal gap, mid-axial wall, axio-occlusal transition, centro-occlusal site) under ×64 magnification. The Mann–Whitney U test was used to detect significant differences between the two groups in terms of marginal and internal fit (α = 0.05).

Results

The mean for the marginal gap was 61.08 μm (±24.77 μm) for CAI compared with 70.40 μm (±28.87 μm) for CI, which was a statistically significant difference. The other mean values for CAI and CI, respectively, were as follows in micrometers (± standard deviation): 88.27 (±41.49) and 92.13 (±49.87) at the mid-axial wall; 144.78 (±46.23) and 155.60 (±55.77) at the axio-occlusal transition; and 155.57 (49.85) and 171.51 (±60.98) at the centro-occlusal site. The CAI group showed significantly lower values of internal fit at the centro-occlusal site.
A quadrant scan with a computer-aided impression was 5 min 6 s more time efficient when compared with a conventional impression, and a full-arch scan was 1 min 34 s more efficient.

Conclusions

Although both direct and indirect digitalization facilitate the fabrication of single crowns and three-unit FDPs with clinically acceptable marginal fit, a significantly better marginal fit was noted with direct digitalization. Digital impressions are also less time-consuming for the dental practitioner and the patient.

Clinical relevance

The results show that a direct, intraoral, digitalized impression technique is more accurate and efficient when compared with conventional impressions in fabricating single crowns and three-unit FDPs.
Literatur
1.
Zurück zum Zitat Christensen GJ (2008) Will digital impressions eliminate the current problems with conventional impressions? J Am Dent Assoc 139(6):761–763CrossRefPubMed Christensen GJ (2008) Will digital impressions eliminate the current problems with conventional impressions? J Am Dent Assoc 139(6):761–763CrossRefPubMed
2.
Zurück zum Zitat Beuer F, Schweiger J, Edelhoff D (2008) Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 204(9):505–511CrossRefPubMed Beuer F, Schweiger J, Edelhoff D (2008) Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 204(9):505–511CrossRefPubMed
3.
Zurück zum Zitat Christensen GJ (2008) The challenge to conventional impressions. J Am Dent Assoc 139(3):347–349CrossRefPubMed Christensen GJ (2008) The challenge to conventional impressions. J Am Dent Assoc 139(3):347–349CrossRefPubMed
4.
Zurück zum Zitat Yuzbasioglu E, Kurt H, Turunc R, Bilir H (2014) Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes. BMC Oral Health. doi:10.1186/1472-6831-14-10 PubMedCentralPubMed Yuzbasioglu E, Kurt H, Turunc R, Bilir H (2014) Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes. BMC Oral Health. doi:10.​1186/​1472-6831-14-10 PubMedCentralPubMed
5.
Zurück zum Zitat Breeding LC, Dixon DL (2000) Accuracy of casts generated from dual-arch impressions. J Prosthet Dent 84(4):403–407CrossRefPubMed Breeding LC, Dixon DL (2000) Accuracy of casts generated from dual-arch impressions. J Prosthet Dent 84(4):403–407CrossRefPubMed
6.
Zurück zum Zitat Cho GC, Chee WW (2004) Distortion of disposable plastic stock trays when used with putty vinyl polysi- loxane impression materials. J Prosthet Dent 92(4):354–358CrossRefPubMed Cho GC, Chee WW (2004) Distortion of disposable plastic stock trays when used with putty vinyl polysi- loxane impression materials. J Prosthet Dent 92(4):354–358CrossRefPubMed
7.
Zurück zum Zitat Luthardt RG et al (2006) Qualitative computer aided evaluation of dental impressions in vivo. Dent Mater 22(1):69–76CrossRefPubMed Luthardt RG et al (2006) Qualitative computer aided evaluation of dental impressions in vivo. Dent Mater 22(1):69–76CrossRefPubMed
8.
Zurück zum Zitat Luthardt RG, Walter MH, Weber A, Koch R, Rudolph H (2008) Clinical parameters influencing the accuracy of 1- and 2-stage impressions: a randomized controlled trial. Int J Prosthodont 21(4):322–327PubMed Luthardt RG, Walter MH, Weber A, Koch R, Rudolph H (2008) Clinical parameters influencing the accuracy of 1- and 2-stage impressions: a randomized controlled trial. Int J Prosthodont 21(4):322–327PubMed
9.
Zurück zum Zitat Balkenhol M, Ferger P, Wöstmann B (2007) Dimensional accuracy of 2-stage putty-wash impressions: influence of impression trays and viscosity. Int J Prosthodont 20(6):573–575PubMed Balkenhol M, Ferger P, Wöstmann B (2007) Dimensional accuracy of 2-stage putty-wash impressions: influence of impression trays and viscosity. Int J Prosthodont 20(6):573–575PubMed
10.
Zurück zum Zitat Di Felice R, Scotti R, Belser UC (2002) The influence of the mixing technique on the content of voids in two polyether impression materials. Schweiz Monatsschr Zahnmed 112(1):12–16PubMed Di Felice R, Scotti R, Belser UC (2002) The influence of the mixing technique on the content of voids in two polyether impression materials. Schweiz Monatsschr Zahnmed 112(1):12–16PubMed
11.
Zurück zum Zitat Persson AS, Andersson M, Oden A, Sandborgh-Englund G (2008) Computer aided analysis of digitized dental stone replicas by dental CAD/CAM technology. Dent Mater 24(8):1123–1130CrossRefPubMed Persson AS, Andersson M, Oden A, Sandborgh-Englund G (2008) Computer aided analysis of digitized dental stone replicas by dental CAD/CAM technology. Dent Mater 24(8):1123–1130CrossRefPubMed
12.
Zurück zum Zitat Belser UC, MacEntee MI, Richter WA (1985) Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study. J Prosthet Dent 53(1):24–29CrossRefPubMed Belser UC, MacEntee MI, Richter WA (1985) Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study. J Prosthet Dent 53(1):24–29CrossRefPubMed
13.
Zurück zum Zitat McLean JW, von Fraunhofer JA (1971) The estimation of cement film thickness by an in vivo technique. Br Dent J 131(3):107–111CrossRefPubMed McLean JW, von Fraunhofer JA (1971) The estimation of cement film thickness by an in vivo technique. Br Dent J 131(3):107–111CrossRefPubMed
14.
Zurück zum Zitat Sailer I, Feher A, Filser F, Gauckler LJ, Lüthy H, Hämmerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20(4):383–388PubMed Sailer I, Feher A, Filser F, Gauckler LJ, Lüthy H, Hämmerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20(4):383–388PubMed
15.
Zurück zum Zitat Padbury A Jr, Eber R, Wang HL (2003) Interactions between the gingiva and the margin of restorations. J Clin Periodontol 30(5):379–385CrossRefPubMed Padbury A Jr, Eber R, Wang HL (2003) Interactions between the gingiva and the margin of restorations. J Clin Periodontol 30(5):379–385CrossRefPubMed
16.
Zurück zum Zitat Lang NP, Kiel RA, Anderhalden K (1983) Clinical and microbiological effects of subgingival restorations with overhanging or clinically perfect margins. J Clin Periodontol 10(6):563–578CrossRefPubMed Lang NP, Kiel RA, Anderhalden K (1983) Clinical and microbiological effects of subgingival restorations with overhanging or clinically perfect margins. J Clin Periodontol 10(6):563–578CrossRefPubMed
17.
Zurück zum Zitat Wettstein F, Sailer I, Roos M, Hämmerle CH (2008) Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. Eur J Oral Sci 116(3):272–279CrossRefPubMed Wettstein F, Sailer I, Roos M, Hämmerle CH (2008) Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. Eur J Oral Sci 116(3):272–279CrossRefPubMed
18.
Zurück zum Zitat Thompson VP, Rekow DE (2004) Dental ceramics and the molar crown testing ground. J Appl Oral Sci 12(spe):26–36CrossRefPubMed Thompson VP, Rekow DE (2004) Dental ceramics and the molar crown testing ground. J Appl Oral Sci 12(spe):26–36CrossRefPubMed
19.
Zurück zum Zitat Conrad HJ, Seong WJ, Pesun IJ (2007) Current ceramic materials and systems with clinical recommendations: a systematic review. J Prosthet Dent 98(5):389–404CrossRefPubMed Conrad HJ, Seong WJ, Pesun IJ (2007) Current ceramic materials and systems with clinical recommendations: a systematic review. J Prosthet Dent 98(5):389–404CrossRefPubMed
21.
Zurück zum Zitat Koller M, Arnetzl GV, Holly L, Arnetzl G (2012) Lava ultimate resin nano ceramic for CAD/ CAM: customization case study. Int J Comput Dent 15(2):159–164PubMed Koller M, Arnetzl GV, Holly L, Arnetzl G (2012) Lava ultimate resin nano ceramic for CAD/ CAM: customization case study. Int J Comput Dent 15(2):159–164PubMed
22.
Zurück zum Zitat Rinke S, Schäfer S, Schmidt AK (2014) Einsatzmöglichkeiten zirkonverstärkter Lithiumsilikat- Keramiken. Quintessenz Zahntech 40(5):536–546 Rinke S, Schäfer S, Schmidt AK (2014) Einsatzmöglichkeiten zirkonverstärkter Lithiumsilikat- Keramiken. Quintessenz Zahntech 40(5):536–546
23.
Zurück zum Zitat Rosentritt M (2013) Verschleißuntersuchung an keramischen Werkstoffen, Report Number: 219_3; 02/2013. Universitätsklinikum Regensburg, Poliklinik für Zahnärztliche Prothetik, Regensburg Rosentritt M (2013) Verschleißuntersuchung an keramischen Werkstoffen, Report Number: 219_3; 02/2013. Universitätsklinikum Regensburg, Poliklinik für Zahnärztliche Prothetik, Regensburg
24.
Zurück zum Zitat Stawarczyk B, Eichberger M, Hoffmann R, Noack F, Schweiger J, Edelhoff D, Beuer F (2014) A novel CAD/ CAM base metal compared to conventional CoCrMo alloys: an in-vitro study of the long-term metal-ceramic bond strength. Oral Health Dent Manag 13(2):446–452PubMed Stawarczyk B, Eichberger M, Hoffmann R, Noack F, Schweiger J, Edelhoff D, Beuer F (2014) A novel CAD/ CAM base metal compared to conventional CoCrMo alloys: an in-vitro study of the long-term metal-ceramic bond strength. Oral Health Dent Manag 13(2):446–452PubMed
25.
Zurück zum Zitat Brawek PK, Wolfart S, Endres L, Kirsten A, Reich S (2013) The clinical accuracy of single crowns exclusively fabricated by digital workflow-the comparison of two systems. Clin Oral Investig 17(9):2119–2125CrossRefPubMed Brawek PK, Wolfart S, Endres L, Kirsten A, Reich S (2013) The clinical accuracy of single crowns exclusively fabricated by digital workflow-the comparison of two systems. Clin Oral Investig 17(9):2119–2125CrossRefPubMed
26.
Zurück zum Zitat Beuer F, Schweiger J, Eichberger M, Kappert HF, Gernet W, Edelhoff D (2009) High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings—a new fabrication mode for all-ceramic restorations. Dent Mater 25(1):121–128CrossRefPubMed Beuer F, Schweiger J, Eichberger M, Kappert HF, Gernet W, Edelhoff D (2009) High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings—a new fabrication mode for all-ceramic restorations. Dent Mater 25(1):121–128CrossRefPubMed
27.
Zurück zum Zitat Mehl A, Koch R, Zaruba M, Ender A (2013) 3D monitoring and quality control using intraoral optical camera systems. Int J Comput Dent 16(1):23–36PubMed Mehl A, Koch R, Zaruba M, Ender A (2013) 3D monitoring and quality control using intraoral optical camera systems. Int J Comput Dent 16(1):23–36PubMed
28.
Zurück zum Zitat Rekow ED (2006) Dental CAD/CAM systems: a 20-year success story. J Am Dent Assoc 137(Suppl):5S–6SCrossRefPubMed Rekow ED (2006) Dental CAD/CAM systems: a 20-year success story. J Am Dent Assoc 137(Suppl):5S–6SCrossRefPubMed
29.
Zurück zum Zitat Mörmann WH, Bindl A (1996) The new creativity in ceramic restorations: dental CAD-CIM. Quintessence Int 27(12):821–828PubMed Mörmann WH, Bindl A (1996) The new creativity in ceramic restorations: dental CAD-CIM. Quintessence Int 27(12):821–828PubMed
30.
Zurück zum Zitat Mehl A, Ender A, Mörmann W, Attin T (2009) Accuracy testing of a new intraoral 3D camera. Int J Comput Dent 12(1):11–28PubMed Mehl A, Ender A, Mörmann W, Attin T (2009) Accuracy testing of a new intraoral 3D camera. Int J Comput Dent 12(1):11–28PubMed
31.
Zurück zum Zitat Ziegler M (2009) Digital impression taking with reproducibly high precision. Int J Comput Dent 12(2):159–163PubMed Ziegler M (2009) Digital impression taking with reproducibly high precision. Int J Comput Dent 12(2):159–163PubMed
32.
Zurück zum Zitat Rohaly J (2009) The development of the Lava chairside oral scanner C.O.S. technology—masterstroke of a legion of talented and committed people. Int J Comput Dent 12(2):165–169PubMed Rohaly J (2009) The development of the Lava chairside oral scanner C.O.S. technology—masterstroke of a legion of talented and committed people. Int J Comput Dent 12(2):165–169PubMed
33.
Zurück zum Zitat Güth JF, Keul C, Stimmelmayr M, Beuer F, Edelhoff D (2013) Accuracy of digital models obtained by direct and indirect data capturing. Clin Oral Investig 17(4):1201–1208, PMID: 22847854CrossRefPubMed Güth JF, Keul C, Stimmelmayr M, Beuer F, Edelhoff D (2013) Accuracy of digital models obtained by direct and indirect data capturing. Clin Oral Investig 17(4):1201–1208, PMID: 22847854CrossRefPubMed
34.
Zurück zum Zitat Kachalia PR, Geissberger MJ (2010) Dentistry a la carte: in-office CAD/CAM technology. J Calif Dent Assoc 38(5):323–330PubMed Kachalia PR, Geissberger MJ (2010) Dentistry a la carte: in-office CAD/CAM technology. J Calif Dent Assoc 38(5):323–330PubMed
35.
Zurück zum Zitat Syrek A, Reich G, Ranftl D, Klein C, Cerny B, Brodesser J (2010) Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent 38(7):553–559CrossRefPubMed Syrek A, Reich G, Ranftl D, Klein C, Cerny B, Brodesser J (2010) Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent 38(7):553–559CrossRefPubMed
37.
Zurück zum Zitat Reich S et al (2005) Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J Oral Sci 113(2):174–179CrossRefPubMed Reich S et al (2005) Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J Oral Sci 113(2):174–179CrossRefPubMed
38.
Zurück zum Zitat Reich S, Kappe K, Teschner H, Schmitt J (2008) Clinical fit of four-unit zirconia posterior fixed dental prostheses. Eur J Oral Sci 116(6):579–584CrossRefPubMed Reich S, Kappe K, Teschner H, Schmitt J (2008) Clinical fit of four-unit zirconia posterior fixed dental prostheses. Eur J Oral Sci 116(6):579–584CrossRefPubMed
39.
Zurück zum Zitat Beuer F, Naumann M, Gernet W (2009) Precision of fit: zirconia three-unit fixed denta prostheses. Clin Oral Investig 13:343–349CrossRefPubMed Beuer F, Naumann M, Gernet W (2009) Precision of fit: zirconia three-unit fixed denta prostheses. Clin Oral Investig 13:343–349CrossRefPubMed
40.
Zurück zum Zitat Almeida e Silva JS, Erdelt K, Edelhoff D, Araujo E, Stimmelmayr M, Vieira LC, Güth JF (2014) Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig 18(2):515–523. doi:10.1007/s00784-013-0987-2 CrossRefPubMed Almeida e Silva JS, Erdelt K, Edelhoff D, Araujo E, Stimmelmayr M, Vieira LC, Güth JF (2014) Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig 18(2):515–523. doi:10.​1007/​s00784-013-0987-2 CrossRefPubMed
41.
Zurück zum Zitat Seelbach P, Brueckel C, Wöstmann B (2013) Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig 17(7):1759–1764CrossRefPubMed Seelbach P, Brueckel C, Wöstmann B (2013) Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig 17(7):1759–1764CrossRefPubMed
42.
Zurück zum Zitat Keul C, Stawarczyk B, Erdelt KJ, Beuer F, Edelhoff D, Güth JF (2014) Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization—a laboratory study. Dent Mater 30(4):400–407CrossRefPubMed Keul C, Stawarczyk B, Erdelt KJ, Beuer F, Edelhoff D, Güth JF (2014) Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization—a laboratory study. Dent Mater 30(4):400–407CrossRefPubMed
44.
Zurück zum Zitat Lee SJ, Gallucci GO (2014) Digital vs. conventional implant impressions: efficiency outcomes. Clin Oral Implants 24(1):111–115CrossRef Lee SJ, Gallucci GO (2014) Digital vs. conventional implant impressions: efficiency outcomes. Clin Oral Implants 24(1):111–115CrossRef
45.
Zurück zum Zitat Gozdowski S, Reich S (2009) A comparison of the fabrication times of all-ceramic partial crowns: Cerec 3D vs IPS Empress. Int J Comput Dent 12(3):279–289PubMed Gozdowski S, Reich S (2009) A comparison of the fabrication times of all-ceramic partial crowns: Cerec 3D vs IPS Empress. Int J Comput Dent 12(3):279–289PubMed
46.
Zurück zum Zitat Patzelt SB, Lamprinos C, Stampf S, Att W (2014) The time efficiency of intraoral scanner: an in vitro com-parative study. J Am Dent Assoc 145(6):542–551CrossRefPubMed Patzelt SB, Lamprinos C, Stampf S, Att W (2014) The time efficiency of intraoral scanner: an in vitro com-parative study. J Am Dent Assoc 145(6):542–551CrossRefPubMed
47.
Zurück zum Zitat Boening KW, Wolf BH, Schmidt AE, Kästner K, Walter MH (2000) Clinical fit of Procera AllCeram crowns. J Prosthet Dent 84(4):419–424CrossRefPubMed Boening KW, Wolf BH, Schmidt AE, Kästner K, Walter MH (2000) Clinical fit of Procera AllCeram crowns. J Prosthet Dent 84(4):419–424CrossRefPubMed
48.
Zurück zum Zitat Holmes JE, Sulik WD, Holland GA, Bayne SC (1992) Marginal fit of castable ceramic crowns. J Prosthet Dent 67(5):594–599CrossRefPubMed Holmes JE, Sulik WD, Holland GA, Bayne SC (1992) Marginal fit of castable ceramic crowns. J Prosthet Dent 67(5):594–599CrossRefPubMed
49.
Zurück zum Zitat Jacobs MS, Windeler AS (1991) An investigation of dental luting cement solubility as a function of the marginal gap. J Prosthet Dent 65(3):436–442CrossRefPubMed Jacobs MS, Windeler AS (1991) An investigation of dental luting cement solubility as a function of the marginal gap. J Prosthet Dent 65(3):436–442CrossRefPubMed
50.
Zurück zum Zitat Hmaidouch R, Neumann R, Mueller WD (2011) Influence of preparation form, luting space setting and cement type on the marginal and internal fit of CAD/CAM crown copings. Int J Comput Dent 14(3):219–226PubMed Hmaidouch R, Neumann R, Mueller WD (2011) Influence of preparation form, luting space setting and cement type on the marginal and internal fit of CAD/CAM crown copings. Int J Comput Dent 14(3):219–226PubMed
51.
Zurück zum Zitat Schweiger J, Beuer F, Edelhoff D (2011) Digital workflow teil 3. Quintessenz Zahntech 37:60–72 Schweiger J, Beuer F, Edelhoff D (2011) Digital workflow teil 3. Quintessenz Zahntech 37:60–72
52.
Zurück zum Zitat Rudolph H, Quaas S, Luthardt RG (2002) Matching point clouds: limits and possibilities. Int J Comput Dent 5(2–3):155–164PubMed Rudolph H, Quaas S, Luthardt RG (2002) Matching point clouds: limits and possibilities. Int J Comput Dent 5(2–3):155–164PubMed
53.
Zurück zum Zitat Ender A, Mehl A (2011) Full arch scans: conventional versus digital impressions—an in-vitro study. Int J Comput Dent 14(1):11–21PubMed Ender A, Mehl A (2011) Full arch scans: conventional versus digital impressions—an in-vitro study. Int J Comput Dent 14(1):11–21PubMed
54.
Zurück zum Zitat Quaas S, Loos R, Sporbeck H, Luthardt RG (2005) Analyse des Einflusses der Puderapplikation auf die Genauigkeit optischer Digitalisierungen. Dtsch Zahnärztl Z 60:96–99 Quaas S, Loos R, Sporbeck H, Luthardt RG (2005) Analyse des Einflusses der Puderapplikation auf die Genauigkeit optischer Digitalisierungen. Dtsch Zahnärztl Z 60:96–99
55.
Zurück zum Zitat Ender A, Mehl A (2013) Influence of scanning strategies on the accuracy of digital intraoral scanning systems. Int J Comput Dent 16(1):11–21PubMed Ender A, Mehl A (2013) Influence of scanning strategies on the accuracy of digital intraoral scanning systems. Int J Comput Dent 16(1):11–21PubMed
56.
Zurück zum Zitat Flugge TV, Schlager S, Nelson K, Nahles S, Metzger MC (2013) Precision of intraoral digital dental im- pressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofac Orthop 144(3):471–478CrossRef Flugge TV, Schlager S, Nelson K, Nahles S, Metzger MC (2013) Precision of intraoral digital dental im- pressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofac Orthop 144(3):471–478CrossRef
57.
Zurück zum Zitat Laurent M, Scheer P, Dejou J, Laborde G (2008) Clinical evaluation of the marginal fit of cast crowns—validation of the silicone replica method. J Oral Rehabil 35(2):116–122CrossRefPubMed Laurent M, Scheer P, Dejou J, Laborde G (2008) Clinical evaluation of the marginal fit of cast crowns—validation of the silicone replica method. J Oral Rehabil 35(2):116–122CrossRefPubMed
58.
Zurück zum Zitat Kohorst P, Brinkmann H, Dittmer MP, Borchers L, Stiesch M (2010) Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses. J Oral Rehabil 37(4):283–291CrossRefPubMed Kohorst P, Brinkmann H, Dittmer MP, Borchers L, Stiesch M (2010) Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses. J Oral Rehabil 37(4):283–291CrossRefPubMed
59.
Zurück zum Zitat Groten M, Axmann D, Probster L, Weber H (2000) Determination of the minimum number of marginal gap measurements required for practical in-vitro testing. J Prosthet Dent 83(1):p40–p49CrossRef Groten M, Axmann D, Probster L, Weber H (2000) Determination of the minimum number of marginal gap measurements required for practical in-vitro testing. J Prosthet Dent 83(1):p40–p49CrossRef
Metadaten
Titel
Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial
verfasst von
Danush Ahrberg
Hans Christoph Lauer
Martin Ahrberg
Paul Weigl
Publikationsdatum
01.03.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Oral Investigations / Ausgabe 2/2016
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-015-1504-6

Weitere Artikel der Ausgabe 2/2016

Clinical Oral Investigations 2/2016 Zur Ausgabe

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.