Skip to main content
Erschienen in: International Journal of Legal Medicine 3/2018

24.11.2017 | Original Article

Evaluation of four commercial quantitative real-time PCR kits with inhibited and degraded samples

verfasst von: Amy S. Holmes, Rachel Houston, Kyleen Elwick, David Gangitano, Sheree Hughes-Stamm

Erschienen in: International Journal of Legal Medicine | Ausgabe 3/2018

Einloggen, um Zugang zu erhalten

Abstract

DNA quantification is a vital step in forensic DNA analysis to determine the optimal input amount for DNA typing. A quantitative real-time polymerase chain reaction (qPCR) assay that can predict DNA degradation or inhibitors present in the sample prior to DNA amplification could aid forensic laboratories in creating a more streamlined and efficient workflow. This study compares the results from four commercial qPCR kits: (1) Investigator® Quantiplex® Pro Kit, (2) Quantifiler® Trio DNA Quantification Kit, (3) PowerQuant® System, and (4) InnoQuant® HY with high molecular weight DNA, low template samples, degraded samples, and DNA spiked with various inhibitors.The results of this study indicate that all kits were comparable in accurately predicting quantities of high quality DNA down to the sub-picogram level. However, the InnoQuant(R) HY kit showed the highest precision across the DNA concentration range tested in this study. In addition, all kits performed similarly with low concentrations of forensically relevant PCR inhibitors. However, in general, the Investigator® Quantiplex® Pro Kit was the most tolerant kit to inhibitors and provided the most accurate quantification results with higher concentrations of inhibitors (except with salt). PowerQuant® and InnoQuant® HY were the most sensitive to inhibitors, but they did indicate significant levels of PCR inhibition. When quantifying degraded samples, each kit provided different degradation indices (DI), with Investigator® Quantiplex® Pro indicating the largest DI and Quantifiler® Trio indicating the smallest DI. When the qPCR kits were paired with their respective STR kit to genotype highly degraded samples, the Investigator® 24plex QS and GlobalFiler® kits generated more complete profiles when the small target concentrations were used for calculating input amount.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
2.
Zurück zum Zitat Di Pasquale F, Cornelius S, König M, Scherer M, Schmid C, Dienemann C, Bochmann L, Prochnow A, Schnibbe T, Engel H (2011) Investigator® Quantiplex kit: for reliable quantification of human DNA in forensic samples. Forensic Sci Int Genet Suppl Ser 3(1):e413–e414. https://doi.org/10.1016/j.fsigss.2011.09.068 Di Pasquale F, Cornelius S, König M, Scherer M, Schmid C, Dienemann C, Bochmann L, Prochnow A, Schnibbe T, Engel H (2011) Investigator® Quantiplex kit: for reliable quantification of human DNA in forensic samples. Forensic Sci Int Genet Suppl Ser 3(1):e413–e414. https://​doi.​org/​10.​1016/​j.​fsigss.​2011.​09.​068
3.
Zurück zum Zitat Loftus A, Murphy G, Brown H, Montgomery A, Tabak J, Baus J, Carroll M, Green A, Sikka S, Sinha S (2017) Development and validation of InnoQuant® HY, a system for quantitation and quality assessment of total human and male DNA using high copy targets. Forensic Sci Int Genet 29:205–217. https://doi.org/10.1016/j.fsigen.2017.04.009 Loftus A, Murphy G, Brown H, Montgomery A, Tabak J, Baus J, Carroll M, Green A, Sikka S, Sinha S (2017) Development and validation of InnoQuant® HY, a system for quantitation and quality assessment of total human and male DNA using high copy targets. Forensic Sci Int Genet 29:205–217. https://​doi.​org/​10.​1016/​j.​fsigen.​2017.​04.​009
4.
Zurück zum Zitat Pineda GM, Montgomery AH, Thompson R, Indest B, Carroll M, Sinha SK (2014) Development and validation of InnoQuant™, a sensitive human DNA quantitation and degradation assessment method for forensic samples using high copy number mobile elements Alu and SVA. Forensic Sci Int Genet 13:224–235. https://doi.org/10.1016/j.fsigen.2014.08.007 Pineda GM, Montgomery AH, Thompson R, Indest B, Carroll M, Sinha SK (2014) Development and validation of InnoQuant™, a sensitive human DNA quantitation and degradation assessment method for forensic samples using high copy number mobile elements Alu and SVA. Forensic Sci Int Genet 13:224–235. https://​doi.​org/​10.​1016/​j.​fsigen.​2014.​08.​007
5.
Zurück zum Zitat Di Pasquale F, Cornelius S, König M, Scherer M, Prochnow A, Peist R (2015) Analysis and interpretation of difficult samples—the interaction of a DNA quantification kit with the right STR assay may facilitate processing of critical trace material. Forensic Sci Int Genet Suppl Ser 5:e407–e408. https://doi.org/10.1016/j.fsigss.2015.09.161 Di Pasquale F, Cornelius S, König M, Scherer M, Prochnow A, Peist R (2015) Analysis and interpretation of difficult samples—the interaction of a DNA quantification kit with the right STR assay may facilitate processing of critical trace material. Forensic Sci Int Genet Suppl Ser 5:e407–e408. https://​doi.​org/​10.​1016/​j.​fsigss.​2015.​09.​161
6.
11.
Zurück zum Zitat Alaeddini R, Walsh SJ, Abbas A (2010) Forensic implications of genetic analyses from degraded DNA—a review. Forensic Sci Int Genet 4(3):148–157. https://doi.org/10.1016/j.fsigen.2009.09.007 Alaeddini R, Walsh SJ, Abbas A (2010) Forensic implications of genetic analyses from degraded DNA—a review. Forensic Sci Int Genet 4(3):148–157. https://​doi.​org/​10.​1016/​j.​fsigen.​2009.​09.​007
14.
Zurück zum Zitat Alaeddini R (2012) Forensic implications of PCR inhibition—a review. Forensic Sci Int Genet 6(3):297–305. https://doi.org/10.1016/j.fsigen.2011.08.006 Alaeddini R (2012) Forensic implications of PCR inhibition—a review. Forensic Sci Int Genet 6(3):297–305. https://​doi.​org/​10.​1016/​j.​fsigen.​2011.​08.​006
16.
Zurück zum Zitat Investigator(R) Quantiplex(R) Pro Handbook (April 2017) Investigator(R) Quantiplex(R) Pro Handbook (April 2017)
17.
Zurück zum Zitat Quantifiler(R) HP and Trio DNA Quantification Kits User Guide (2017) Quantifiler(R) HP and Trio DNA Quantification Kits User Guide (2017)
18.
Zurück zum Zitat PowerQuant System Technical Manual (March 2015) PowerQuant System Technical Manual (March 2015)
19.
Zurück zum Zitat InnoQuant(R) HY User Guide v1.5 (Dec. 2016) InnoQuant(R) HY User Guide v1.5 (Dec. 2016)
20.
Zurück zum Zitat National Institute of Standards & Technology Certificte of Analysis Standard Reference Material (R) 2372 Human DNA Quantification Standard, Issued 1/13 (Jan. 2013) National Institute of Standards & Technology Certificte of Analysis Standard Reference Material (R) 2372 Human DNA Quantification Standard, Issued 1/13 (Jan. 2013)
21.
Zurück zum Zitat QIAamp(R) DNA Investigator Handbook (June 2012) QIAamp(R) DNA Investigator Handbook (June 2012)
22.
Zurück zum Zitat PrepFiler(R) and PrepFiler(R) BTA Forensic DNA Extraction Kits User Guide (2012) PrepFiler(R) and PrepFiler(R) BTA Forensic DNA Extraction Kits User Guide (2012)
23.
Zurück zum Zitat Isolation of DNA from forensic casework samples part B (purification) protocol sheet, version 2 (May 2008) Isolation of DNA from forensic casework samples part B (purification) protocol sheet, version 2 (May 2008)
24.
Zurück zum Zitat QIAamp(R) DNA FFPE Tissue Handbook (June 2012) QIAamp(R) DNA FFPE Tissue Handbook (June 2012)
25.
Zurück zum Zitat Investigator(R) 24plex QS Handbook (July 2016) Investigator(R) 24plex QS Handbook (July 2016)
26.
Zurück zum Zitat GlobalFiler™ PCR Amplification kit user guide (2016) GlobalFiler™ PCR Amplification kit user guide (2016)
27.
Zurück zum Zitat PowerPlex(R) Fusion 6C System for Use on the Applied Biosystems (R) Genetic Analyzers Technical Manual (April 2017) PowerPlex(R) Fusion 6C System for Use on the Applied Biosystems (R) Genetic Analyzers Technical Manual (April 2017)
Metadaten
Titel
Evaluation of four commercial quantitative real-time PCR kits with inhibited and degraded samples
verfasst von
Amy S. Holmes
Rachel Houston
Kyleen Elwick
David Gangitano
Sheree Hughes-Stamm
Publikationsdatum
24.11.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Legal Medicine / Ausgabe 3/2018
Print ISSN: 0937-9827
Elektronische ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-017-1745-9

Weitere Artikel der Ausgabe 3/2018

International Journal of Legal Medicine 3/2018 Zur Ausgabe

Neu im Fachgebiet Rechtsmedizin