Skip to main content
Erschienen in:

26.11.2021 | Case Report

Excision of a median nerve schwannoma using the 3D microscope: a heads-up ergonomic approach to microsurgical tasks in hand surgery

verfasst von: Sonia Ubong, Theodora Papavasiliou, Lauren Uppal

Erschienen in: European Journal of Plastic Surgery | Ausgabe 5/2022

Einloggen, um Zugang zu erhalten

Abstract

Recent advances in technology and refinement of surgical techniques have facilitated exponential growth in the field of microsurgery. However, use of the traditional binocular microscope can expose surgeons to excessive neck and body fatigue that cause work-related musculoskeletal injuries. Thereby, ergonomic errors that lead to musculoskeletal symptoms can have a significant impact on performance in the operating room as well as home and work life. With the introduction of multi-imaging technologies, “heads-up”, a new 3-dimensional (3D) viewing system, allows the microsurgeon to operate in a physiologically comfortable position. Despite favourable reports in neurosurgery, it is yet to be scientifically determined whether the three-dimensional heads-up display technology may be unconditionally employed for more complex hand surgery such as an excision of a median nerve tumour. The following case report illustrates the utility of this technology, as an operative and education tool in the field of hand surgery.
Level of evidence: Level V, therapeutic study.
Literatur
1.
Zurück zum Zitat Tamai S (2009) History of microsurgery. Plast Reconstr Surg 124:e282–e294CrossRef Tamai S (2009) History of microsurgery. Plast Reconstr Surg 124:e282–e294CrossRef
2.
Zurück zum Zitat Mendez B, Chiodo M, Vandevender D, Patel P (2016) Heads-up 3D microscopy. Plast Reconstr Surg - Glob Open 4(5):e717CrossRef Mendez B, Chiodo M, Vandevender D, Patel P (2016) Heads-up 3D microscopy. Plast Reconstr Surg - Glob Open 4(5):e717CrossRef
3.
Zurück zum Zitat Damodaran O, Lee J, Lee G (2013) Microscope in modern spinal surgery: advantages, ergonomics and limitations. ANZ J Surg 83(4):211–214CrossRef Damodaran O, Lee J, Lee G (2013) Microscope in modern spinal surgery: advantages, ergonomics and limitations. ANZ J Surg 83(4):211–214CrossRef
4.
Zurück zum Zitat Capone A, Parikh P, Gatti M, Davidson B, Davison S (2010) Occupational injury in plastic surgeons. Plast Reconstr Surg 125(5):1555–1561CrossRef Capone A, Parikh P, Gatti M, Davidson B, Davison S (2010) Occupational injury in plastic surgeons. Plast Reconstr Surg 125(5):1555–1561CrossRef
5.
Zurück zum Zitat Guha D, Alotaibi N, Nguyen N, Gupta S, McFaul C, Yang V (2017) Augmented reality in neurosurgery: a review of current concepts and emerging applications. Can J Neurosci 44(3):235–245 Guha D, Alotaibi N, Nguyen N, Gupta S, McFaul C, Yang V (2017) Augmented reality in neurosurgery: a review of current concepts and emerging applications. Can J Neurosci 44(3):235–245
6.
Zurück zum Zitat Alaraj A, Lemole M, Finkle J, Yudkowsky R, Wallace A, Luciano C, Banerjee P, Rizzi S, Charbel F (2011) Virtual reality training in neurosurgery: review of current status and future applications. Surg Neurol Int 2(1):52CrossRef Alaraj A, Lemole M, Finkle J, Yudkowsky R, Wallace A, Luciano C, Banerjee P, Rizzi S, Charbel F (2011) Virtual reality training in neurosurgery: review of current status and future applications. Surg Neurol Int 2(1):52CrossRef
7.
Zurück zum Zitat Cabrilo I, Bijlenga P, Schaller K (2014) Augmented reality in the surgery of cerebral aneurysms: a technical report. Oper Neurosurg 10(2):252–261CrossRef Cabrilo I, Bijlenga P, Schaller K (2014) Augmented reality in the surgery of cerebral aneurysms: a technical report. Oper Neurosurg 10(2):252–261CrossRef
8.
Zurück zum Zitat Khansa I, Khansa L, Westvik T, Ahmad J, Lista F, Janis J (2018) Work-related musculoskeletal injuries in plastic surgeons in the United States, Canada, and Norway. Plast Reconstr Surg 141(1):165e–175eCrossRef Khansa I, Khansa L, Westvik T, Ahmad J, Lista F, Janis J (2018) Work-related musculoskeletal injuries in plastic surgeons in the United States, Canada, and Norway. Plast Reconstr Surg 141(1):165e–175eCrossRef
9.
Zurück zum Zitat Uluç K, Kujoth G, Başkaya M (2009) Operating microscopes: past, present, and future. Neurosurg Focus 27(3):E4CrossRef Uluç K, Kujoth G, Başkaya M (2009) Operating microscopes: past, present, and future. Neurosurg Focus 27(3):E4CrossRef
10.
Zurück zum Zitat Eckardt C, Ahdab K, Eckert T (2019) Use of mobile phones during heads-up surgery—a new way of teaching cataract and vitreoretinal surgery. Retina 39(1):S191–S193CrossRef Eckardt C, Ahdab K, Eckert T (2019) Use of mobile phones during heads-up surgery—a new way of teaching cataract and vitreoretinal surgery. Retina 39(1):S191–S193CrossRef
11.
Zurück zum Zitat Moura-Coelho N, Henriques J, Nascimento J, Dutra-Medeiros M (2019) Three-dimensional display systems in Opthalmic Surgery – a review. Eur J Ophthalmol Rev 13(1):31–36CrossRef Moura-Coelho N, Henriques J, Nascimento J, Dutra-Medeiros M (2019) Three-dimensional display systems in Opthalmic Surgery – a review. Eur J Ophthalmol Rev 13(1):31–36CrossRef
Metadaten
Titel
Excision of a median nerve schwannoma using the 3D microscope: a heads-up ergonomic approach to microsurgical tasks in hand surgery
verfasst von
Sonia Ubong
Theodora Papavasiliou
Lauren Uppal
Publikationsdatum
26.11.2021
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Plastic Surgery / Ausgabe 5/2022
Print ISSN: 0930-343X
Elektronische ISSN: 1435-0130
DOI
https://doi.org/10.1007/s00238-021-01907-0

Neu im Fachgebiet Chirurgie

Verbände und Cremes gegen Dekubitus: „Wir wissen nicht, was sie bringen!“

Die Datenlage zur Wirksamkeit von Verbänden oder topischen Mitteln zur Prävention von Druckgeschwüren sei schlecht, so die Verfasser einer aktuellen Cochrane-Studie. Letztlich bleibe es unsicher, ob solche Maßnahmen den Betroffenen nutzen oder schaden.

Nackenschmerzen nach Bandscheibenvorfall: Muskeltraining hilft!

Bei hartnäckigen Schmerzen aufgrund einer zervikalen Radikulopathie schlägt ein Team der Universität Istanbul vor, lokale Steroidinjektionen mit einem speziellen Trainingsprogramm zur Stabilisierung der Nackenmuskulatur zu kombinieren.

US-Team empfiehlt Gastropexie nach Hiatushernien-Op.

Zur Vermeidung von Rezidiven nach Reparatur einer paraösophagealen Hiatushernie sollte einem US-Team zufolge der Magen bei der Op. routinemäßig an der Bauchwand fixiert werden. Das Ergebnis einer randomisierten Studie scheint dafür zu sprechen.

Mit Lidocain kommt der Darm nicht schneller in Schwung

Verzögertes Wiederanspringen der Darmfunktion ist ein Hauptfaktor dafür, wenn Patientinnen und Patienten nach einer Kolonresektion länger als geplant im Krankenhaus bleiben müssen. Ob man diesem Problem mit Lidocain vorbeugen kann, war Thema einer Studie.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.