Expectant management of prolonged hemolysis following complete transcatheter coil closure of a patent ductus arteriosus after previous pulmonary artery banding: a case report

verfasst von: Mao-Sheng Hwang, Ching-Chia Kuo, Hung-Tao Chung, Hsin-Mao Hsu, Jaw-Ji Chu, Chao-Jan Wang

Erschienen in: BMC Cardiovascular Disorders | Ausgabe 1/2021

Abstract

Background

Transcatheter coil occlusion has been the treatment of choice for closure of small patent ductus arteriosus (PDA). In spite of its safety, complications such as hemolysis still occasionally occur. And the hemolysis almost always occurs following partial transcatheter closure of PDA; hence, it occurs extremely rarely following complete transcatheter closure of PDA without residual ductal flow.

Case presentation

Here, we describe a male newborn who developed prolonged hemolysis following complete transcatheter coil closure of his PDA after previous palliative pulmonary artery banding. Over the following days, we corrected his refractory anemia by repeated blood transfusion with packed red blood cells and frequently monitored his hemoglobin, serum total bilirubin, and serum lactate dehydrogenase. We speculated that the high-velocity pulmonary blood flow jet coming into contact with the extruded part of the coil led to red blood cell mechanical injury, thereby resulting in the hemolysis. We adopted expectant management in expectation of the endothelialization of the coil with a resultant reduction in the hemolysis. The hemolysis, as expected, was reduced gradually until it spontaneously resolved 81 days after coil implantation.

Conclusions

This case reminds us that hemolysis can still potentially occur following complete transcatheter coil closure of PDA. It also highlights the importance of preventing coils from extruding into the pulmonary artery in patients after previous pulmonary artery banding.
Begleitmaterial
Additional file 1: Video 1. Suprasternal long-axis view with the transducer rotated and oriented to the right scapular tip (simultaneous 2-dimensional [right] and color flow Doppler [left] recordings) revealed right aortic arch without residual ductal shunting, but part of the coil was extruded into the bifurcation of the main pulmonary artery, in addition to the high-velocity mosaic pulmonary flow jet resulting from the previously performed pulmonary artery banding. It also showed the high-velocity pulmonary flow jet hit the extruded coil.
Additional file 2: Video 2. Modified apical five-chamber view (simultaneous 2-dimensional [right] and color flow Doppler [left] recordings) showed no residual ductal shunting, but part of the coil was extruded into the bifurcation of the main pulmonary artery, in addition to the high-velocity mosaic pulmonary flow jet resulting from the previously performed pulmonary artery banding. It also showed the direct collision of the high-velocity pulmonary flow jet with the extruded coil.
Hinweise

Supplementary Information

The online version contains supplementary material available at https://​doi.​org/​10.​1186/​s12872-021-02365-z.
Mao-Sheng Hwang and Ching-Chia Kuo have equally contributed to this work

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
PDA
Patent ductus arteriosus
RBC
Red blood cell

Background

Transcatheter coil occlusion has been the treatment of choice for closure of small patent ductus arteriosus (PDA). In spite of its safety, complications such as hemolysis still occasionally occur [1]. And the hemolysis almost always occurs following partial transcatheter closure of PDA [1]; hence, it exceedingly rarely occurs following complete transcatheter closure of PDA without residual ductal flow [2]. In one study, the authors presumed that aortic blood contact with the extruded part of the coil (Flipper detachable coil, Bloomington, Indiana, USA) led to red blood cell (RBC) mechanical injury, thereby resulting in hemolysis [2]. We recently treated a unique male newborn who, unexpectedly, developed prolonged hemolysis following complete transcatheter coil closure of his PDA after previous palliative pulmonary artery banding. To our knowledge, this is probably the second case of hemolysis occurring following complete transcatheter closure of PDA, with likely sharing a similar mechanism with the first patient but occurring in a different scenario.

Case presentation

A 1-day-old full-term male newborn with birth body weight 2930 gm was diagnosed with a double-outlet right ventricle {S, D, D} with a subpulmonary ventricular septal defect (Taussig-Bing anomaly) and a right aortic arch associated with a right-sided PDA. He underwent palliative pulmonary artery banding through left minithoracotomy when he was 20 days old, but the PDA was not ligated at that time due to its right-sided position. The postoperative Doppler echocardiography showed peak velocity of the systolic jet across the main pulmonary artery band was 4.0 m/s, which indicated the estimated peak pressure gradient across the band was 64 mmHg. However, the heart failure in the newborn was still uncontrollable despite adequately performed and hemodynamically effective pulmonary artery banding. Thus, transcatheter occlusion of the PDA (Krichenko Type A1, 1.7 mm at its narrowest potion) (Fig. 1a) was performed via a retrograde route using a Gianturco coil (MWCE-38-6-4, Cook, Inc., Bloomington, IN) on the 25th day of life. Postimplantation aortography showed no residual shunting, but approximately half of the coil was extruded into the pulmonary artery with a resultant redundant and bulky appearance (Fig. 1b).
Unexpectedly, he developed gross hematuria 3 h later. The laboratory data 1 day after coil implantation revealed elevated serum total bilirubin (from 9.1 to 14.7 mg/dl; normal range 0.1–1.2 mg/dl), increased serum lactate dehydrogenase (1796 U/L; normal range 135–260 U/L), decreased hemoglobin (from 11.8 to 11.2 g/dl; normal range 9.6–12.8 g/dl) (Fig. 2) and reduced serum haptoglobin (< 7.69 mg/dl; normal range 30–200 mg/dl). The postimplantation echocardiography showed no residual ductal shunting, but part of the coil was extruded into the bifurcation of the main pulmonary artery, in addition to the high-velocity mosaic pulmonary flow jet resulting from the previously performed pulmonary artery banding. It also showed the high-velocity pulmonary flow jet hit the extruded coil. (Fig. 3 and Additional file 1: Video 1; Fig. 4 and Additional file 2: Video 2). The postimplantation computed tomography angiography more clearly demonstrated that part of the coil was extruded into the junction of the main and right pulmonary arteries (Figs. 5, 6, 7). We did not know the exact cause of the suspected hemolysis at this time. Over the following days, we were only able to correct his refractory anemia by repeated blood transfusion with packed RBCs and frequently monitor his hemoglobin, serum total bilirubin, and serum lactate dehydrogenase (Fig. 2).
At day 24 postimplantation, reticulocytosis (reticulocyte count 5.4%; normal range 0.4–2.8%) was noted. A peripheral blood smear showed schistocytes and fragmented RBCs. Both direct and indirect Coombs tests were negative. Thus, intravascular nonimmune hemolysis was more definitively diagnosed. After review of a previous similar case report [2] and the postimplantation images (Figs. 3, 4, 5, 6, 7 and Additional file 1: Video 1; Additional file 2: Video 2), we speculated that a high-velocity pulmonary blood flow jet coming into contact with the extruded part of the coil led to RBC mechanical injury, thereby resulting in the hemolysis [2, 3]. The high-velocity pulmonary blood flow jet resulted from the previously performed pulmonary artery banding.
At that time, we decided to adopt expectant management in expectation of the endothelialization of the coil with a resultant reduction in the hemolysis [4]. Fortunately, the degree of hemolysis began decreasing gradually until spontaneous resolution 81 days postimplantation, as reflected in the gradual reduction in serum total bilirubin and lactate dehydrogenase and a reduced need for blood transfusion (total amount of transfused packed RBCs: 1127 ml/36 transfusions) (Fig. 2). The patient then underwent Jatene procedure at 111 days of age (day 86 postimplantation). Unfortunately, he expired 9 h postoperatively due to low cardiac output syndrome after the extracorporeal membrane oxygenation support was removed.
Timeline of the relevant events is summarized in Table 1.
Table 1
Timeline of relevant events
Age
Relevant events
1 D/O
Diagnosed with a double-outlet right ventricle {S, D, D} with a subpulmonary ventricular septal defect (Taussig-Bing anomaly) and a right aortic arch associated with a patent ductus arteriosus
20 D/O
Pulmonary artery banding performed
25 D/O
Transcatheter coil occlusion of the patent ductus arteriosus; hematuria developing 3 h later
26 D/O
Hemolysis suspected and start of repeated blood transfusion to correct its refractory anemia
49 D/O
Intravascular nonimmune hemolysis more definitively diagnosed
96 D/O
Stop of blood transfusion
106 D/O
Spontaneous resolution of hemolysis presumed
111 D/O
Jatene procedure performed
112 D/O
Expired after the extracorporeal membrane oxygenation support removed
D/O days old

Discussion and conclusions

Herein, we describe a case of prolonged hemolysis following complete transcatheter coil closure of PDA after previous palliative pulmonary artery banding. We speculate that a high-velocity pulmonary blood flow jet coming into contact with the extruded part of the coil led to RBC mechanical injury. Thus, the underlying mechanism of hemolysis in this patient was probably similar to that in the aforementioned case, although the authors of that study did not further elaborate on the possible underlying mechanisms [2].
The possible underlying mechanisms of hemolysis in our patient might be extrapolated from those that occur after mitral valve repair [5]. The following two mechanisms are probably involved: direct collision of the high-velocity pulmonary blood flow jet with the coil and/or fragmentation of the high-velocity pulmonary blood flow jet by the coil [5]. These two mechanisms are associated with high shear stress, and the high-velocity pulmonary blood flow jet hitting the nonendothelialized coil surface might generate such stress, leading to traumatic disruption of the RBCs [5].
The possible clinical course of this rarely occurring hemolysis has not been well established, although the hemolysis in the previous similar case still persisted 47 days postimplantation before rescue surgery [2]. Prosthetic materials usually become rapidly endothelialized within several weeks [4, 5], and the degree of hemolysis presumably will be gradually reduced as the coil gradually becomes endothelialized [4]. However, the high-velocity pulmonary blood flow jet might denude the endothelium [5], thereby delaying the endothelialization process and hence prolonging the hemolytic course to the 81st day postimplantation.
With regard to potentially better management strategies of our patient, we retrospectively consider that the earlier percutaneous pulling of a large part of the coil grasped with a snare from the aortic end of the ductus away from the pulmonary artery to the aortic end of the ductus, leaving approximately 1 loop of the coil in the pulmonary end of the ductus, might have shortened the duration of hemolysis. The potential benefit of this attempt is that it might prevent the high-velocity pulmonary blood flow jet from coming into contact with the coil, thereby avoiding the direct collision of the high-velocity pulmonary blood flow jet with the coil and/or fragmentation of the high-velocity pulmonary blood flow jet by the coil [5]. If this attempt succeeds, the hemolysis probably could resolve more quickly and, in addition, it could avoid the much invasive rescue surgery as described in the first case [2]. The potential risk of this attempt is that pulling of too large part of the coil away from the pulmonary artery to the aortic end of the ductus might result in embolization of the coil, aortic coarctation, or hemolysis as described in the first case [2]. But strict adherence to the method of leaving approximately 1 loop of the coil in the pulmonary end of the ductus and avoiding pulling through the ductus might prevent its embolization [6]. Moreover, the space of the aortic ampulla of the ductus of this particular patient is large enough to accommodate the large part of the coil without causing aortic coarctation or hemolysis (Fig. 1a, b).
But prevention is better than cure. Then, what could be done to prevent this hemolytic complication? We think that strict adherence to the method of allowing 1 loop of the coil to form in the pulmonary artery during the first step of deploying the coil is of paramount importance [6]. With this 1 loop formed in the pulmonary artery, the catheter with pusher wire and the partially extruded coil all together are withdrawn until the exposed loop of the coil touches the pulmonary end of the ductus [6]. During the following maneuver of deploying the remainder of the coil into the aortic end of the ductus, the pulmonary loop of coil is observed closely to be sure that the single loop of coil in the pulmonary end of the ductus remains in the proper location and is not pulled through the ductus or pushed back into the pulmonary artery [6]. This method should prevent the coil from extruding into the pulmonary artery, thereby avoiding the hemolytic complication.
In conclusion, this case reminds us that hemolysis can still potentially occur following complete transcatheter coil closure of PDA, and we should prevent the coil from extruding into the pulmonary artery in patients who had previously undergone pulmonary artery banding or other similar scenarios that resulted in the high-velocity pulmonary blood flow jet. It also demonstrates the protracted course of hemolysis with the potential for spontaneous resolution; earlier rescue strategies could probably markedly shorten the duration of hemolysis.

Acknowledgements

None.

Declarations

The case report was approved by the Chang Gung Medical Foundation Institutional Review Board.
Written informed consent for publication of their clinical details and/or clinical images was obtained from the parent of the patient. A copy of the consent form is available for review by the Editor of this journal.

Competing interests

The authors declare that they have no competing interests.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Anhänge

Supplementary Information

Additional file 1: Video 1. Suprasternal long-axis view with the transducer rotated and oriented to the right scapular tip (simultaneous 2-dimensional [right] and color flow Doppler [left] recordings) revealed right aortic arch without residual ductal shunting, but part of the coil was extruded into the bifurcation of the main pulmonary artery, in addition to the high-velocity mosaic pulmonary flow jet resulting from the previously performed pulmonary artery banding. It also showed the high-velocity pulmonary flow jet hit the extruded coil.
Additional file 2: Video 2. Modified apical five-chamber view (simultaneous 2-dimensional [right] and color flow Doppler [left] recordings) showed no residual ductal shunting, but part of the coil was extruded into the bifurcation of the main pulmonary artery, in addition to the high-velocity mosaic pulmonary flow jet resulting from the previously performed pulmonary artery banding. It also showed the direct collision of the high-velocity pulmonary flow jet with the extruded coil.
Literatur
1.
Zurück zum Zitat Shim D, Wechsler DS, Lloyd TR, Beekman RH III. Hemolysis following coil embolization of a patent ductus arteriosus. Cathet Cardiovasc Diagn. 1996;39:287–90.CrossRef Shim D, Wechsler DS, Lloyd TR, Beekman RH III. Hemolysis following coil embolization of a patent ductus arteriosus. Cathet Cardiovasc Diagn. 1996;39:287–90.CrossRef
2.
Zurück zum Zitat Cace N, Ahel V, Bilic I. Complete transcatheter closure of a patent arterial duct with subsequent haemolysis. Cardiol Young. 2010;20:462–4.CrossRef Cace N, Ahel V, Bilic I. Complete transcatheter closure of a patent arterial duct with subsequent haemolysis. Cardiol Young. 2010;20:462–4.CrossRef
3.
Zurück zum Zitat Anil SR, Sivakumar K, Philip AK, Francis E, Kumar K. Clinical course and management strategies for hemolysis after transcatheter closure of patent arterial ducts. Catheter Cardiovasc Interv. 2003;59:538–43.CrossRef Anil SR, Sivakumar K, Philip AK, Francis E, Kumar K. Clinical course and management strategies for hemolysis after transcatheter closure of patent arterial ducts. Catheter Cardiovasc Interv. 2003;59:538–43.CrossRef
4.
Zurück zum Zitat Inoue M, Kaku B, Kanaya H, Ohka T, Ueda M, Masahiro S, Shimizu M, Mabuchi H. Reduction of hemolysis without reoperation following mitral valve repair. Circ J. 2003;67:799–801.CrossRef Inoue M, Kaku B, Kanaya H, Ohka T, Ueda M, Masahiro S, Shimizu M, Mabuchi H. Reduction of hemolysis without reoperation following mitral valve repair. Circ J. 2003;67:799–801.CrossRef
5.
Zurück zum Zitat Yeo TC, Freeman WK, Schaff HV, Orszulak TA. Mechanisms of hemolysis after mitral valve repair: assessment by serial echocardiography. J Am Coll Cardiol. 1998;32(3):717–23.CrossRef Yeo TC, Freeman WK, Schaff HV, Orszulak TA. Mechanisms of hemolysis after mitral valve repair: assessment by serial echocardiography. J Am Coll Cardiol. 1998;32(3):717–23.CrossRef
6.
Zurück zum Zitat Mullins CE. Transcatheter occlusion of the patent ductus arteriosus (PDA). In: Mullins CE, editor. Cardiac catheterization in congenital heart disease: pediatric and adult. Malden: Blackwell Futura Inc; 2006. p. 693–727. Mullins CE. Transcatheter occlusion of the patent ductus arteriosus (PDA). In: Mullins CE, editor. Cardiac catheterization in congenital heart disease: pediatric and adult. Malden: Blackwell Futura Inc; 2006. p. 693–727.
Metadaten
Titel
Expectant management of prolonged hemolysis following complete transcatheter coil closure of a patent ductus arteriosus after previous pulmonary artery banding: a case report
verfasst von
Mao-Sheng Hwang
Ching-Chia Kuo
Hung-Tao Chung
Hsin-Mao Hsu
Jaw-Ji Chu
Chao-Jan Wang
Publikationsdatum
01.12.2021
Verlag
BioMed Central
Erschienen in
BMC Cardiovascular Disorders / Ausgabe 1/2021
Elektronische ISSN: 1471-2261
DOI
https://doi.org/10.1186/s12872-021-02365-z

Weitere Artikel der Ausgabe 1/2021

BMC Cardiovascular Disorders 1/2021 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.