Excerpt

https://static-content.springer.com/image/art%3A10.1007%2Fs00586-015-4115-7/MediaObjects/586_2015_4115_Figa_HTML.jpg The authors have to be commended for this interesting manuscript addressing the surgical challenge of correcting a severe cervical kyphosis in patients with additional severe osteoporosis [1]. …
Literatur
1.
Zurück zum Zitat Mattei TA, Rehman AA, Issawi A, Fassett DR (2015) Surgical challenges in the management of cervical kyphotic deformity in patients with severe osteoporosis: an illustrative case of a patient with Hajdu-Cheney syndrome. Eur Spine J. doi:10.1007/s00586-015-4092-x Mattei TA, Rehman AA, Issawi A, Fassett DR (2015) Surgical challenges in the management of cervical kyphotic deformity in patients with severe osteoporosis: an illustrative case of a patient with Hajdu-Cheney syndrome. Eur Spine J. doi:10.​1007/​s00586-015-4092-x
2.
Zurück zum Zitat Pitzen T, Brabier D, Tintinger F, Steudel WI, Strowitzki M (2002) screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical plating. Eur Spine J 11:494–499PubMedCentralCrossRefPubMed Pitzen T, Brabier D, Tintinger F, Steudel WI, Strowitzki M (2002) screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical plating. Eur Spine J 11:494–499PubMedCentralCrossRefPubMed
3.
Zurück zum Zitat Pitzen TR, Drumm J, Bruchmann B, Barbier DD, Steudel WI (2006) Effectiviness of cemented rescue screws for anterior cervical plate fixation. J Neurosurg Spine 4:60–63CrossRefPubMed Pitzen TR, Drumm J, Bruchmann B, Barbier DD, Steudel WI (2006) Effectiviness of cemented rescue screws for anterior cervical plate fixation. J Neurosurg Spine 4:60–63CrossRefPubMed
4.
Zurück zum Zitat Oppenlander ME, Bina R, Snyder L, Dickmann CA (2014) Intravertebral polymethylmethacrylate augmentation of anterior cervical discectomy fusion and plating in the setting of osteoporosis. J Spinal Disord Tech 27:185–188CrossRefPubMed Oppenlander ME, Bina R, Snyder L, Dickmann CA (2014) Intravertebral polymethylmethacrylate augmentation of anterior cervical discectomy fusion and plating in the setting of osteoporosis. J Spinal Disord Tech 27:185–188CrossRefPubMed
5.
Zurück zum Zitat Wsachke A, Walter J, Duenisch P, Kalff R, Ewald C (2013) Anterior cervical intercorporal fusion in patients with osteoporotic or tumorous fractures using a cement augmented cervical plate system: first results of a single-center prospective study. J Spinal Disord Tech 26(3):E112–E117CrossRef Wsachke A, Walter J, Duenisch P, Kalff R, Ewald C (2013) Anterior cervical intercorporal fusion in patients with osteoporotic or tumorous fractures using a cement augmented cervical plate system: first results of a single-center prospective study. J Spinal Disord Tech 26(3):E112–E117CrossRef
6.
Zurück zum Zitat Koller H, Hempfing A, Acosta F, Fox M, Scheiter A, Tuber M, Holz U, Resch H, Hitzl W (2008) Cervical anterior transpedicular screw fixation. Part I: study on morphological feasibility, indications and technical prerequisites. Eur Spine J 17:523–538PubMedCentralCrossRefPubMed Koller H, Hempfing A, Acosta F, Fox M, Scheiter A, Tuber M, Holz U, Resch H, Hitzl W (2008) Cervical anterior transpedicular screw fixation. Part I: study on morphological feasibility, indications and technical prerequisites. Eur Spine J 17:523–538PubMedCentralCrossRefPubMed
7.
Zurück zum Zitat Koller H, Acosta F, Tauber M, Fox M, Hudelmaier M, Forstner R, Augat P, Penzkofer R, Pirich C, Kässmann H, Resch H, Hitzl W (2008) Cervical anterior transpedicular screw fixation (ATPS)-Part II. Accuracy of manual insertion and pull-out strength of ATPS. Eur Spine J 17:523–538PubMedCentralCrossRefPubMed Koller H, Acosta F, Tauber M, Fox M, Hudelmaier M, Forstner R, Augat P, Penzkofer R, Pirich C, Kässmann H, Resch H, Hitzl W (2008) Cervical anterior transpedicular screw fixation (ATPS)-Part II. Accuracy of manual insertion and pull-out strength of ATPS. Eur Spine J 17:523–538PubMedCentralCrossRefPubMed
8.
Zurück zum Zitat Wu C, Chen C, Wu W, Zhao W, Sun P, Fan J, Bi Z, Zhang J, Ouyang J (2014) Biomechanical analysis of differential pull-out strengths of bone screws using cervical anterior transpedicular technique in normal and osteoporotic cervical cadaveric spines. Spine 40(1):E1–E8CrossRef Wu C, Chen C, Wu W, Zhao W, Sun P, Fan J, Bi Z, Zhang J, Ouyang J (2014) Biomechanical analysis of differential pull-out strengths of bone screws using cervical anterior transpedicular technique in normal and osteoporotic cervical cadaveric spines. Spine 40(1):E1–E8CrossRef
Metadaten
Titel
Expert’s comment concerning Grand Rounds case entitled “Surgical challenges in the management of cervical kyphotic deformity in patients with severe osteoporosis: an illustrative case of a patient with Hajdu-Cheney syndrome” (T. A. Mattei, A. A. Rehman, A. Issawi, D. R. Fassett)
verfasst von
Luca Papavero
Publikationsdatum
01.12.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe 12/2015
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-015-4115-7

Weitere Artikel der Ausgabe 12/2015

European Spine Journal 12/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.