Skip to main content
Erschienen in: Clinical Neuroradiology 1/2017

05.05.2015 | Original Article

Extensive pneumatized air cells causing susceptibility artifacts in the petrosus part of the ICA

verfasst von: M.R. McCoy, MD, E. Broussalis, MD, M. Killer, MD, PhD, J. Steinbacher, DI Dr., F. Klausner, MD

Erschienen in: Clinical Neuroradiology | Ausgabe 1/2017

Einloggen, um Zugang zu erhalten

Abstract

Introduction

3D-Time-of-flight magnetic-resonance-angiography (TOF MRA) is an established method in vessel analysis. However, many artifacts that occur may lead to a false diagnosis. This retrospective study evaluates the coherence of MR artifacts to extensive pneumatized air cells surrounding the internal carotid artery (ICA) in the petrosus part of the temporal bone.

Materials and methods

Patients who received 3D-TOF MRA and multidetector helical computed tomography (CT) angiography were registered from April 2012 to April 2013. Of these patients, both ICAs in the petrosus part were analyzed. Vertical maximum intensity projection (MIP) artifacts were graduated as normal, mild to moderate, and severe artifacts. The distinction of the vertical part of the pneumatized air cells was also categorized in three groups, regarding the circumference of the ICA in pneumatization ≤ 90°, between 90° and 180°, and ≥ 180°.

Results

A total of 203 vessels were collected for analysis. The more extensive the pneumatized air cells were present, the more band-like artifacts and pseudostenosis at the vertical portion of the petrosus part of the ICA were registered.

Conclusion

Careful examination of the source images and evaluation of the size of the pneumatized air cells with CT scan are essential to avoid false positive diagnosis in the distal petrosus part of the ICA.
Literatur
1.
Zurück zum Zitat Gizewski ER, Ladd ME, Paul A, Wanke I, Goricke S, Forsting M. Water excitation: a possible pitfall in cerebral time-of-flight angiography. AJNR Am J Neuroradiol. 2005;26:152–5.PubMed Gizewski ER, Ladd ME, Paul A, Wanke I, Goricke S, Forsting M. Water excitation: a possible pitfall in cerebral time-of-flight angiography. AJNR Am J Neuroradiol. 2005;26:152–5.PubMed
2.
Zurück zum Zitat Chiowanich P, Mitchell DG, Ortega HV, Mohamed F. Arterial pseudostenosis on first-pass gadolinium-enhanced three-dimensional MR angiography: new observation of a potential pitfall. AJR Am J Roentgenol. 2000;175:523–7.CrossRefPubMed Chiowanich P, Mitchell DG, Ortega HV, Mohamed F. Arterial pseudostenosis on first-pass gadolinium-enhanced three-dimensional MR angiography: new observation of a potential pitfall. AJR Am J Roentgenol. 2000;175:523–7.CrossRefPubMed
4.
Zurück zum Zitat Miyazaki M, Kojima F, Ichinose N, Onozato Y, Igarashi H. A novel saturation transfer contrast method for 3d time-of-flight magnetic resonance angiography: a slice-selective off-resonance sinc pulse (SORS) technique. Magn Reson Med. 1994;32:52–9.CrossRefPubMed Miyazaki M, Kojima F, Ichinose N, Onozato Y, Igarashi H. A novel saturation transfer contrast method for 3d time-of-flight magnetic resonance angiography: a slice-selective off-resonance sinc pulse (SORS) technique. Magn Reson Med. 1994;32:52–9.CrossRefPubMed
5.
Zurück zum Zitat Wilcock DJ, Jaspan T, Worthington BS. Problems and pitfalls of 3-D TOF magnetic resonance angiography of the intracranial circulation. Clin Radiol. 1995;50:526–32. Wilcock DJ, Jaspan T, Worthington BS. Problems and pitfalls of 3-D TOF magnetic resonance angiography of the intracranial circulation. Clin Radiol. 1995;50:526–32.
6.
Zurück zum Zitat Fisher CM, Ojemann RG, Roberson GH. Spontaneous dissection of cervico-cerebral arteries. Can J Neurol Sci. 1978;5:9–19.CrossRefPubMed Fisher CM, Ojemann RG, Roberson GH. Spontaneous dissection of cervico-cerebral arteries. Can J Neurol Sci. 1978;5:9–19.CrossRefPubMed
7.
Zurück zum Zitat Ramalho J, Castillo M. Vascular imaging of the central nervous system: physical principles, clinical applications and emerging techniques. Vol. 10. John Wiley & Sons, Inc., Hoboken; 2013. Ramalho J, Castillo M. Vascular imaging of the central nervous system: physical principles, clinical applications and emerging techniques. Vol. 10. John Wiley & Sons, Inc., Hoboken; 2013.
8.
Zurück zum Zitat Teitelbaum GP, Bradley WG, Jr., Klein BD. MR imaging artifacts, ferromagnetism, and magnetic torque of intravascular filters, stents, and coils. Radiology. 1988;166:657–64.CrossRefPubMed Teitelbaum GP, Bradley WG, Jr., Klein BD. MR imaging artifacts, ferromagnetism, and magnetic torque of intravascular filters, stents, and coils. Radiology. 1988;166:657–64.CrossRefPubMed
9.
Zurück zum Zitat Schuster L, Hauser T, Essig M. Significance of MR angiography for imaging diagnostics of carotid artery diseases. Radiologe. 2010;50:597–606. Schuster L, Hauser T, Essig M. Significance of MR angiography for imaging diagnostics of carotid artery diseases. Radiologe. 2010;50:597–606.
10.
Zurück zum Zitat Huang YC, Chen CM, Lai SL, Lee TH, Chen ST, Chin SC, Chen YC. Spontaneous intrapetrous internal carotid artery dissection: a case report and literature review. J Neurol Sci. 2007;253:90–3.CrossRefPubMed Huang YC, Chen CM, Lai SL, Lee TH, Chen ST, Chin SC, Chen YC. Spontaneous intrapetrous internal carotid artery dissection: a case report and literature review. J Neurol Sci. 2007;253:90–3.CrossRefPubMed
11.
Zurück zum Zitat Leclerc X, Gauvrit JY, Nicol L, Pruvo JP. Contrast-enhanced MR angiography of the craniocervical vessels: a review. Neuroradiology. 1999;41:867–74.CrossRefPubMed Leclerc X, Gauvrit JY, Nicol L, Pruvo JP. Contrast-enhanced MR angiography of the craniocervical vessels: a review. Neuroradiology. 1999;41:867–74.CrossRefPubMed
12.
Zurück zum Zitat Yang CW, Carr JC, Futterer SF, Morasch MD, Yang BP, Shors SM, Finn JP. Contrast-enhanced MR angiography of the carotid and vertebrobasilar circulations. AJNR Am J Neuroradiol. 2005;26:2095–101.PubMed Yang CW, Carr JC, Futterer SF, Morasch MD, Yang BP, Shors SM, Finn JP. Contrast-enhanced MR angiography of the carotid and vertebrobasilar circulations. AJNR Am J Neuroradiol. 2005;26:2095–101.PubMed
13.
Zurück zum Zitat Remonda L, Senn P, Barth A, Arnold M, Lovblad KO, Schroth G. Contrast-enhanced 3D MR angiography of the carotid artery: comparison with conventional digital subtraction angiography. AJNR Am J Neuroradiol. 2002;23:213–9. Remonda L, Senn P, Barth A, Arnold M, Lovblad KO, Schroth G. Contrast-enhanced 3D MR angiography of the carotid artery: comparison with conventional digital subtraction angiography. AJNR Am J Neuroradiol. 2002;23:213–9.
14.
Zurück zum Zitat Marckmann P, Skov L. Nephrogenic systemic fibrosis: clinical picture and treatment. Radiol Clin North Am. 2009;47:833–40.CrossRefPubMed Marckmann P, Skov L. Nephrogenic systemic fibrosis: clinical picture and treatment. Radiol Clin North Am. 2009;47:833–40.CrossRefPubMed
15.
Zurück zum Zitat Virapongse C, Sarwar M, Bhimani S, Sasaki C, Shapiro R. Computed tomography of temporal bone pneumatization: 1. Normal pattern and morphology. AJR Am J Roentgenol. 1985;145:473–81.CrossRefPubMed Virapongse C, Sarwar M, Bhimani S, Sasaki C, Shapiro R. Computed tomography of temporal bone pneumatization: 1. Normal pattern and morphology. AJR Am J Roentgenol. 1985;145:473–81.CrossRefPubMed
16.
Zurück zum Zitat Schenck JF. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys. 1996;23:815–50.CrossRefPubMed Schenck JF. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys. 1996;23:815–50.CrossRefPubMed
17.
Zurück zum Zitat Stanescu T, Wachowicz K, Jaffray DA. Characterization of tissue magnetic susceptibility-induced distortions for MRIgRT. Med Phys. 2012;39:7185–193. Stanescu T, Wachowicz K, Jaffray DA. Characterization of tissue magnetic susceptibility-induced distortions for MRIgRT. Med Phys. 2012;39:7185–193.
18.
Zurück zum Zitat Moser E, Stahlberg F, Ladd ME, Trattnig S. 7-T MR—from research to clinical applications? NMR Biomed. 2012;25:695–716. Moser E, Stahlberg F, Ladd ME, Trattnig S. 7-T MR—from research to clinical applications? NMR Biomed. 2012;25:695–716.
Metadaten
Titel
Extensive pneumatized air cells causing susceptibility artifacts in the petrosus part of the ICA
verfasst von
M.R. McCoy, MD
E. Broussalis, MD
M. Killer, MD, PhD
J. Steinbacher, DI Dr.
F. Klausner, MD
Publikationsdatum
05.05.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Neuroradiology / Ausgabe 1/2017
Print ISSN: 1869-1439
Elektronische ISSN: 1869-1447
DOI
https://doi.org/10.1007/s00062-015-0392-0

Weitere Artikel der Ausgabe 1/2017

Clinical Neuroradiology 1/2017 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.