Skip to main content
Erschienen in: Pediatric Radiology 1/2019

26.09.2018 | Original Article

Extent of tube-current reduction using sinogram affirmed iterative reconstruction in pediatric computed tomography: phantom study

verfasst von: Ajit Brindhaban

Erschienen in: Pediatric Radiology | Ausgabe 1/2019

Einloggen, um Zugang zu erhalten

Abstract

Background

Iterative image reconstruction techniques can produce diagnostic-quality computed tomography (CT) images with lower radiation dose.

Objective

To quantify the reduction in x-ray tube-current setting and optimize pediatric CT scans using different strengths of an iterative reconstruction technique.

Materials and methods

The head, chest and abdomen regions of an anthropomorphic phantom representing a 5-year-old patient were scanned using standard CT protocols. Images were reconstructed using filtered back projection and different strengths of a sinogram affirmed iterative reconstruction technique. Repeated measurements of contrast-to-noise ratios in the lungs, bone and soft-tissue regions of the phantom were carried out. Maximum increase in contrast-to-noise ratio with iterative reconstruction strength was identified and a tube-current reduction factor was calculated. Head scans were repeated with reduced tube current and compared to filtered back projection images.

Results

Iterative reconstruction strength of 3 for head and chest images and 4 for abdomen images were optimum, resulting in contrast-to-noise ratio increase of about 50%. A tube-current reduction factor of 1.2 for head images was calculated. Images of the head acquired using reduced tube-current showed similar contrast-to-noise ratio as images form filtered back projection with full tube current.

Conclusion

Optimum strength of iterative reconstruction technique has been identified for head, chest and abdomen images. Reductions in tube current of 20%, resulting in similar radiation dose reduction, have been established.
Literatur
1.
Zurück zum Zitat Klink T, Obmann V, Heverhagen J et al (2014) Reducing CT radiation dose with iterative reconstruction algorithms: the influence of scan and reconstruction parameters on image quality and CTDIvol. Eur J Radiol 83:1645–1654CrossRefPubMed Klink T, Obmann V, Heverhagen J et al (2014) Reducing CT radiation dose with iterative reconstruction algorithms: the influence of scan and reconstruction parameters on image quality and CTDIvol. Eur J Radiol 83:1645–1654CrossRefPubMed
2.
Zurück zum Zitat Bosch de Basea M, Salotti JA, Pearce MS et al (2016) Trends and patterns in the use of computed tomography in children and young adults in Catalonia — results from the EPI-CT study. Pediatr Radiol 46:119–129CrossRefPubMed Bosch de Basea M, Salotti JA, Pearce MS et al (2016) Trends and patterns in the use of computed tomography in children and young adults in Catalonia — results from the EPI-CT study. Pediatr Radiol 46:119–129CrossRefPubMed
3.
Zurück zum Zitat Bae S, Kim M, Yoon C et al (2014) Effects of adaptive statistical iterative reconstruction on radiation dose reduction and diagnostic accuracy of pediatric abdominal CT. Pediatr Radiol 44:1541–1547CrossRefPubMed Bae S, Kim M, Yoon C et al (2014) Effects of adaptive statistical iterative reconstruction on radiation dose reduction and diagnostic accuracy of pediatric abdominal CT. Pediatr Radiol 44:1541–1547CrossRefPubMed
4.
Zurück zum Zitat Kim J, Kim M, Kim H, Lee M (2014) Radiation dose reduction and image quality in pediatric abdominal CT with kVp and mAs modulation and an iterative reconstruction technique. Clin Imaging 38:710–714CrossRefPubMed Kim J, Kim M, Kim H, Lee M (2014) Radiation dose reduction and image quality in pediatric abdominal CT with kVp and mAs modulation and an iterative reconstruction technique. Clin Imaging 38:710–714CrossRefPubMed
5.
Zurück zum Zitat Yu L, Fletcher J, Shiung M et al (2015) Radiation dose reduction in pediatric body CT using iterative reconstruction and a novel image-based denoising method. AJR Am J Roentgenol 205:1026–1037CrossRefPubMedPubMedCentral Yu L, Fletcher J, Shiung M et al (2015) Radiation dose reduction in pediatric body CT using iterative reconstruction and a novel image-based denoising method. AJR Am J Roentgenol 205:1026–1037CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Yoon H, Kim M-J, Yoon C-S et al (2015) Radiation dose and image quality in pediatric CT: effects of iterative reconstruction in normal and overweight children. Pediatr Radiol 45:337–344CrossRefPubMed Yoon H, Kim M-J, Yoon C-S et al (2015) Radiation dose and image quality in pediatric CT: effects of iterative reconstruction in normal and overweight children. Pediatr Radiol 45:337–344CrossRefPubMed
7.
Zurück zum Zitat Van den Harder A, Willemink M, Budde R et al (2015) Hybrid and model-based iterative reconstruction technique for pediatric CT. AJR Am J Roentgenol 204:645–653CrossRef Van den Harder A, Willemink M, Budde R et al (2015) Hybrid and model-based iterative reconstruction technique for pediatric CT. AJR Am J Roentgenol 204:645–653CrossRef
8.
Zurück zum Zitat Smarda M, Alexopoulou E, Mazioti A et al (2015) Pediatric chest HRCT using the iDose hybrid iterative reconstruction algorithm: which iDose level to choose? J Phys Conf Ser 637:1–4CrossRef Smarda M, Alexopoulou E, Mazioti A et al (2015) Pediatric chest HRCT using the iDose hybrid iterative reconstruction algorithm: which iDose level to choose? J Phys Conf Ser 637:1–4CrossRef
9.
Zurück zum Zitat McKnight C, Watcharotone K, Ibrahim M et al (2014) Adaptive statistical iterative reconstruction: reducing dose while preserving image quality in the pediatric head CT examination. Pediatr Radiol 44:997–1003CrossRefPubMed McKnight C, Watcharotone K, Ibrahim M et al (2014) Adaptive statistical iterative reconstruction: reducing dose while preserving image quality in the pediatric head CT examination. Pediatr Radiol 44:997–1003CrossRefPubMed
10.
Zurück zum Zitat Vorona G, Zuccoli G, Sutcavage T et al (2012) The use of adaptive statistical iterative reconstruction in pediatric head CT: a feasibility study. AJNR Am J Neuroradiol 34:205–211CrossRefPubMed Vorona G, Zuccoli G, Sutcavage T et al (2012) The use of adaptive statistical iterative reconstruction in pediatric head CT: a feasibility study. AJNR Am J Neuroradiol 34:205–211CrossRefPubMed
11.
Zurück zum Zitat Lee S, Kim M, Yoon C, Lee M (2012) Radiation dose reduction with the adaptive statistical iterative reconstruction (ASIR) technique for chest CT in children: an intra-individual comparison. Eur J Radiol 81:e938–e943CrossRefPubMed Lee S, Kim M, Yoon C, Lee M (2012) Radiation dose reduction with the adaptive statistical iterative reconstruction (ASIR) technique for chest CT in children: an intra-individual comparison. Eur J Radiol 81:e938–e943CrossRefPubMed
12.
Zurück zum Zitat Karmazyn B, Liang Y, Ai H et al (2014) Optimization of hybrid iterative reconstruction level in pediatric body CT. AJR Am J Roentgenol 202:426–431CrossRefPubMed Karmazyn B, Liang Y, Ai H et al (2014) Optimization of hybrid iterative reconstruction level in pediatric body CT. AJR Am J Roentgenol 202:426–431CrossRefPubMed
13.
Zurück zum Zitat Brady S, Moore B, Yee B, Kaufman R (2013) Pediatric CT: implementation of ASIR for substantial radiation dose reduction while maintaining pre-ASIR image noise. Radiology 270:223–231CrossRefPubMedPubMedCentral Brady S, Moore B, Yee B, Kaufman R (2013) Pediatric CT: implementation of ASIR for substantial radiation dose reduction while maintaining pre-ASIR image noise. Radiology 270:223–231CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Qiu D, Seeram E (2016) Does iterative reconstruction improve image quality and reduce dose in computed tomography? Radiol Open J 1:42–54CrossRef Qiu D, Seeram E (2016) Does iterative reconstruction improve image quality and reduce dose in computed tomography? Radiol Open J 1:42–54CrossRef
16.
Zurück zum Zitat Masuda T, Funama Y, Kiguchi M et al (2016) Radiation dose reduction based on CNR index with low-tube voltage scan for pediatric CT: experimental study using anthropomorphic phantoms. Springerplus 5:2064 Masuda T, Funama Y, Kiguchi M et al (2016) Radiation dose reduction based on CNR index with low-tube voltage scan for pediatric CT: experimental study using anthropomorphic phantoms. Springerplus 5:2064
Metadaten
Titel
Extent of tube-current reduction using sinogram affirmed iterative reconstruction in pediatric computed tomography: phantom study
verfasst von
Ajit Brindhaban
Publikationsdatum
26.09.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Pediatric Radiology / Ausgabe 1/2019
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-018-4260-3

Weitere Artikel der Ausgabe 1/2019

Pediatric Radiology 1/2019 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.