26.11.2018 | Original Article

Feasibility of simultaneous dual isotope acquisition for myocardial perfusion imaging with a cadmium zinc telluride camera

Zeitschrift:
Journal of Nuclear Cardiology
Autoren:
MD Bernard Songy, MD Mohamed Guernou, MD David Lussato, MD Mathieu Queneau, MD Gerald Bonardel, MD Jean-François Grellier, MSc Ludovic Flahaut, MD Duc Nguyen
Wichtige Hinweise

Electronic supplementary material

The online version of this article (https://​doi.​org/​10.​1007/​s12350-018-1452-z) contains supplementary material, which is available to authorized users.
The authors of this article have provided a PowerPoint file, available for download at SpringerLink, which summarizes the contents of the paper and is free for re-use at meetings and presentations. Search for the article DOI on SpringerLink.com.

Abstract

Background

We studied the impact of technetium-99m (99mTc) in the thallium-201 (201Tl) energy window (70 keV) to determine if CZT cardiac cameras allow us to perform simultaneous dual-isotope acquisition for myocardial perfusion imaging.

Methods

We included 117 consecutive patients. We injected 0.7 MBq/kg of 201Tl at stress, performed the first scan (image T1), then injected at rest 2 MBq/kg of 99mTc-tetrofosmin and immediately acquired a second scan with reconstruction in the energy window of thallium (image T2). A corrected thallium image was created by the subtraction of 99mTc downscattered photons (image TS). We compared spectra, image quality, and semiquantitative scores on T1, T2, and TS images.

Results

Though T2 images were of worse quality, TS images were of equal quality compared to T1 images in most cases. Scores show an underestimation of abnormalities in 20% of patients on T2 images and in 10% on TS images.

Conclusions

Despite the improved energy resolution of CZT cameras, downscatter of technetium in the 201Tl window leads to an underestimation of the pathological territory in 10% to 20% of cases. It does not allow us to use simultaneous dual-isotope acquisition in clinical practice without additional tools for scatter correction.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Weitere Produktempfehlungen anzeigen
Zusatzmaterial
Supplementary material 1 (PPTX 1100 kb)
12350_2018_1452_MOESM1_ESM.pptx
Literatur
Über diesen Artikel
  1. Das kostenlose Testabonnement läuft nach 14 Tagen automatisch und formlos aus. Dieses Abonnement kann nur einmal getestet werden.

  2. Das kostenlose Testabonnement läuft nach 14 Tagen automatisch und formlos aus. Dieses Abonnement kann nur einmal getestet werden.

Neu im Fachgebiet Kardiologie

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Kardiologie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise