Sustained interest and an increase of possible indications endorse the role of robot-assisted surgery of the head and neck region. However, broad clinical application is impeded by substantial extra cost, time exposure and a supposed deficit of haptic and tactile feedback. The role of haptic feedback has barely been examined in this context, and literature provides only limited objective validation. This point of criticism applies to all commercially available systems. We created an experimental setup to evaluate, quantify and compare the performance of surgical systems. The daVinci system (Intuitive Surgical), the Flex system (Medrobotics) and standard rigid instruments (23 cm laryngoscopic grasper, Karl Storz) were compared with the human hand by head and neck surgeons (n = 15), performing a variety of surgical tasks. Specific samples with different rigidity were sorted with all devices, and the resulting orders were analyzed by permutation analysis, indicating differences in precision and accuracy of haptic and tactile feedback. The human hand was superior in all trials, acting as reference modality. The flexible instruments of the Flex system performed better than the electro-mechanically decoupled instruments of the daVinci system for the majority of measures recorded, suggesting a benefit in terms of haptic and tactile feedback in this context. While not all aspects of haptic and tactile feedback were accessible, this first objective comparison endorses the inferiority of robot-assisted surgery in terms of haptic and tactile feedback, compared to the human sense or standard surgical tools. Furthermore, the immediate force transmission of the Flex system seems to be superior to the electro-mechanical transformation of the daVinci system, indicating an advantage in terms of haptic and tactile feedback in immediate comparison. This study is providing a basis for further experiments and the development of robotic surgery towards an implementation in clinical routine.
Literatur
1.
Zurück zum Zitat Friedrich DT, Scheithauer MO, Greve J, Hoffmann TK, Schuler PJ (2016) Recent advances in robot-assisted head and neck surgery. Int J Med Robot Comput Assist Surg MRCAS doi:10.1002/rcs.1744 Friedrich DT, Scheithauer MO, Greve J, Hoffmann TK, Schuler PJ (2016) Recent advances in robot-assisted head and neck surgery. Int J Med Robot Comput Assist Surg MRCAS doi:10.​1002/​rcs.​1744
2.
Zurück zum Zitat Dombree M, Crott R, Lawson G, Janne P, Castiaux A, Krug B (2014) Cost comparison of open approach, transoral laser microsurgery and transoral robotic surgery for partial and total laryngectomies. Eur Arch Otorhinolaryngol 271(10):2825–2834. doi:10.1007/s00405-014-3056-9 CrossRefPubMed Dombree M, Crott R, Lawson G, Janne P, Castiaux A, Krug B (2014) Cost comparison of open approach, transoral laser microsurgery and transoral robotic surgery for partial and total laryngectomies. Eur Arch Otorhinolaryngol 271(10):2825–2834. doi:10.​1007/​s00405-014-3056-9 CrossRefPubMed
5.
Zurück zum Zitat Schuler PJ, Duvvuri U, Friedrich DT, Rotter N, Scheithauer MO, Hoffmann TK (2015) First use of a computer-assisted operator-controlled flexible endoscope for transoral surgery. The Laryngoscope 125(3):645–648. doi:10.1002/lary.24957 CrossRefPubMed Schuler PJ, Duvvuri U, Friedrich DT, Rotter N, Scheithauer MO, Hoffmann TK (2015) First use of a computer-assisted operator-controlled flexible endoscope for transoral surgery. The Laryngoscope 125(3):645–648. doi:10.​1002/​lary.​24957 CrossRefPubMed
6.
Zurück zum Zitat Friedrich DT, Scheithauer MO, Greve J, Duvvuri U, Sommer F, Hoffmann TK, Schuler PJ (2015) Potential advantages of a single-port, operator-controlled flexible endoscope system for transoral surgery of the larynx. Ann Otol Rhinol Laryngol. doi:10.1177/0003489415575548 PubMed Friedrich DT, Scheithauer MO, Greve J, Duvvuri U, Sommer F, Hoffmann TK, Schuler PJ (2015) Potential advantages of a single-port, operator-controlled flexible endoscope system for transoral surgery of the larynx. Ann Otol Rhinol Laryngol. doi:10.​1177/​0003489415575548​ PubMed
7.
Zurück zum Zitat Schuler PJ, Hoffmann TK, Veit JA, Rotter N, Friedrich DT, Greve J, Scheithauer MO (2016) Hybrid procedure for total laryngectomy with a flexible robot-assisted surgical system. Int J Med Robot Comput Assist Surg MRCAS doi:10.1002/rcs.1749 Schuler PJ, Hoffmann TK, Veit JA, Rotter N, Friedrich DT, Greve J, Scheithauer MO (2016) Hybrid procedure for total laryngectomy with a flexible robot-assisted surgical system. Int J Med Robot Comput Assist Surg MRCAS doi:10.​1002/​rcs.​1749
9.
Zurück zum Zitat Lederman SJ, Klatzky RL (1993) Extracting object properties through haptic exploration. Acta Psychol (Amst) 84(1):29–40CrossRef Lederman SJ, Klatzky RL (1993) Extracting object properties through haptic exploration. Acta Psychol (Amst) 84(1):29–40CrossRef
11.
Zurück zum Zitat Hoffmann TK, Schuler PJ, Bankfalvi A, Greve J, Heusgen L, Lang S, Mattheis S (2014) Comparative analysis of resection tools suited for transoral robot-assisted surgery. Eur Arch Otorhinolaryngol 271(5):1207–1213. doi:10.1007/s00405-013-2615-9 CrossRefPubMed Hoffmann TK, Schuler PJ, Bankfalvi A, Greve J, Heusgen L, Lang S, Mattheis S (2014) Comparative analysis of resection tools suited for transoral robot-assisted surgery. Eur Arch Otorhinolaryngol 271(5):1207–1213. doi:10.​1007/​s00405-013-2615-9 CrossRefPubMed
12.
Zurück zum Zitat Liu WP, Azizian M, Sorger J, Taylor RH, Reilly BK, Cleary K, Preciado D (2014) Cadaveric feasibility study of da Vinci Si-assisted cochlear implant with augmented visual navigation for otologic surgery. JAMA Otolaryngol Head Neck Surg 140(3):208–214. doi:10.1001/jamaoto.2013.6443 CrossRefPubMed Liu WP, Azizian M, Sorger J, Taylor RH, Reilly BK, Cleary K, Preciado D (2014) Cadaveric feasibility study of da Vinci Si-assisted cochlear implant with augmented visual navigation for otologic surgery. JAMA Otolaryngol Head Neck Surg 140(3):208–214. doi:10.​1001/​jamaoto.​2013.​6443 CrossRefPubMed
14.
Zurück zum Zitat Schuler PJ, Hoffmann TK, Duvvuri U, Rotter N, Greve J, Scheithauer MO (2016) Demonstration of nasopharyngeal surgery with a single port operator-controlled flexible endoscope system. Head Neck 38(3):370–374. doi:10.1002/hed.23910 CrossRefPubMed Schuler PJ, Hoffmann TK, Duvvuri U, Rotter N, Greve J, Scheithauer MO (2016) Demonstration of nasopharyngeal surgery with a single port operator-controlled flexible endoscope system. Head Neck 38(3):370–374. doi:10.​1002/​hed.​23910 CrossRefPubMed
15.
Zurück zum Zitat Tavakoli M, Patel RV, Moallem M (2005) Haptic interaction in robot-assisted endoscopic surgery: a sensorized end-effector. Int J Med Robot Comput Assist Surg MRCAS 1(2):53–63. doi:10.1002/rcs.16 CrossRef Tavakoli M, Patel RV, Moallem M (2005) Haptic interaction in robot-assisted endoscopic surgery: a sensorized end-effector. Int J Med Robot Comput Assist Surg MRCAS 1(2):53–63. doi:10.​1002/​rcs.​16 CrossRef
16.
Zurück zum Zitat Liu C, Moreira P, Zemiti N, Poignet P (2011) 3D force control for robotic-assisted beating heart surgery based on viscoelastic tissue model. Conf Proc Ann Int Conf IEEE Eng Med Biol Soc IEEE Eng Med Biol Soc Conf 2011:7054–7058. doi:10.1109/IEMBS.2011.6091783 Liu C, Moreira P, Zemiti N, Poignet P (2011) 3D force control for robotic-assisted beating heart surgery based on viscoelastic tissue model. Conf Proc Ann Int Conf IEEE Eng Med Biol Soc IEEE Eng Med Biol Soc Conf 2011:7054–7058. doi:10.​1109/​IEMBS.​2011.​6091783
17.
Zurück zum Zitat Byrn JC, Schluender S, Divino CM, Conrad J, Gurland B, Shlasko E, Szold A (2007) Three-dimensional imaging improves surgical performance for both novice and experienced operators using the da Vinci Robot System. Am J Surg 193(4):519–522. doi:10.1016/j.amjsurg.2006.06.042 CrossRefPubMed Byrn JC, Schluender S, Divino CM, Conrad J, Gurland B, Shlasko E, Szold A (2007) Three-dimensional imaging improves surgical performance for both novice and experienced operators using the da Vinci Robot System. Am J Surg 193(4):519–522. doi:10.​1016/​j.​amjsurg.​2006.​06.​042 CrossRefPubMed
Metadaten
Titel
Features of haptic and tactile feedback in TORS-a comparison of available surgical systems
verfasst von
Daniel T. Friedrich
L. Dürselen
B. Mayer
S. Hacker
F. Schall
J. Hahn
T. K. Hoffmann
P. J. Schuler
J. Greve
Publikationsdatum
03.05.2017
Verlag
Springer London
Erschienen in
Journal of Robotic Surgery / Ausgabe 1/2018
Print ISSN: 1863-2483
Elektronische ISSN: 1863-2491
DOI
https://doi.org/10.1007/s11701-017-0702-4

Weitere Artikel der Ausgabe 1/2018

Journal of Robotic Surgery 1/2018 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

CME: 2 Punkte

Prof. Dr. med. Gregor Antoniadis Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

CME: 2 Punkte

Dr. med. Benjamin Meyknecht, PD Dr. med. Oliver Pieske Das Webinar S2e-Leitlinie „Distale Radiusfraktur“ beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

CME: 2 Punkte

Dr. med. Mihailo Andric
Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.