Skip to main content
Erschienen in:

13.11.2021 | Scientific Article

Fully automated deep learning for knee alignment assessment in lower extremity radiographs: a cross-sectional diagnostic study

verfasst von: Sebastian Simon, Gilbert M. Schwarz, Alexander Aichmair, Bernhard J. H. Frank, Allan Hummer, Matthew D. DiFranco, Martin Dominkus, Jochen G. Hofstaetter

Erschienen in: Skeletal Radiology | Ausgabe 6/2022

Einloggen, um Zugang zu erhalten

Abstract

Objectives

Accurate assessment of knee alignment and leg length discrepancy is currently measured manually from standing long-leg radiographs (LLR), a process that is both time consuming and poorly reproducible. The aim was to assess the performance of a commercial available AI software by comparing its outputs with manually performed measurements.

Materials and methods

The AI was trained on over 15,000 radiographs to measure various clinical angles and lengths from LLRs. We performed a retrospective single-center analysis on 295 LLRs obtained between 2015 and 2020 from male and female patients over 18 years. AI and expert measurements were performed independently. Kellgren-Lawrence score and reading time were assessed. All measurements were compared and non-inferiority, mean-absolute-deviation (sMAD), and intra-class-correlation (ICC) were calculated.

Results

A total of 295 LLRs from 284 patients (mean age, 65 years (18; 90); 97 (34.2%) men) were analyzed. The AI model produces outputs on 98.0% of the LLRs. Manually annotations were considered as 100% accurate. For each measurement, its divergence was calculated, resulting in an overall accuracy of 89.2% when comparing the AI outputs to the manually measured. AI vs. mean observer revealed an sMAD between 0.39 and 2.19° for angles and 1.45–5.00 mm for lengths. AI showed good reliability in all lengths and angles (ICC ≥ 0.87). Non-inferiority comparing AI to the mean observer revealed an equivalence-index (γ) between 0.54 and 3.03° for angles and − 0.70–1.95 mm for lengths. On average, AI was 130 s faster than clinicians.

Conclusion

Automated measurements of knee alignment and length measurements produced with an AI tool result in reproducible, accurate measures with a time savings compared to manually acquired measurements.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
5.
Zurück zum Zitat McDaniel G, Mitchell KL, Charles C, Kraus VB. A comparison of five approaches to measurement of anatomic knee alignment from radiographs. Osteoarthr Cartil. NIH Public Access; 2010 [cited 2020 Sep 8];18:273–7. Available from:/pmc/articles/PMC2818371/?report=abstract McDaniel G, Mitchell KL, Charles C, Kraus VB. A comparison of five approaches to measurement of anatomic knee alignment from radiographs. Osteoarthr Cartil. NIH Public Access; 2010 [cited 2020 Sep 8];18:273–7. Available from:/pmc/articles/PMC2818371/?report=abstract
9.
Zurück zum Zitat Duron L, Ducarouge A, Gillibert A, Lainé J, Allouche C, Cherel N, et al. Assessment of an AI aid in detection of adult appendicular skeletal fractures by emergency physicians and radiologists: a multicenter cross-sectional diagnostic study. Radiology. 2021 [cited 2021 Aug 2];203886. Available from: http://pubs.rsna.org/doi/10.1148/radiol.2021203886 Duron L, Ducarouge A, Gillibert A, Lainé J, Allouche C, Cherel N, et al. Assessment of an AI aid in detection of adult appendicular skeletal fractures by emergency physicians and radiologists: a multicenter cross-sectional diagnostic study. Radiology. 2021 [cited 2021 Aug 2];203886. Available from: http://​pubs.​rsna.​org/​doi/​10.​1148/​radiol.​2021203886
18.
Zurück zum Zitat Waldt, Simone, Matthias Eiber and KW. Messverfahren und Klassifikationen in der muskuloskelettalen Radiologie. 2nd ed. Verlag GT, editor. Stuttgart; 2017. Waldt, Simone, Matthias Eiber and KW. Messverfahren und Klassifikationen in der muskuloskelettalen Radiologie. 2nd ed. Verlag GT, editor. Stuttgart; 2017.
23.
Zurück zum Zitat J. M. Mellado1, I. Quintana, N. Yanguas, J. Salceda Artola, I. Sanmartin RMCC. Normal anatomy and variations of the proximal femur: a reappraisal with 64-slice MDCT. Eur Congr Radiol. 2014 [cited 2021 Jun 11]; Available from: https://doi.org/10.1594/ecr2014/C-1825 J. M. Mellado1, I. Quintana, N. Yanguas, J. Salceda Artola, I. Sanmartin RMCC. Normal anatomy and variations of the proximal femur: a reappraisal with 64-slice MDCT. Eur Congr Radiol. 2014 [cited 2021 Jun 11]; Available from: https://​doi.​org/​10.​1594/​ecr2014/​C-1825
26.
Zurück zum Zitat Babazadeh S, Dowsey MM, Bingham RJ, Ek ET, Stoney JD, Choong PFM. The long leg radiograph is a reliable method of assessing alignment when compared to computer-assisted navigation and computer tomography. Knee. 2013 [cited 2021 Jun 11];20:242–9. Available from: http://www.ncbi.nlm.nih.gov/pubmed/22892197 Babazadeh S, Dowsey MM, Bingham RJ, Ek ET, Stoney JD, Choong PFM. The long leg radiograph is a reliable method of assessing alignment when compared to computer-assisted navigation and computer tomography. Knee. 2013 [cited 2021 Jun 11];20:242–9. Available from: http://​www.​ncbi.​nlm.​nih.​gov/​pubmed/​22892197
27.
28.
Zurück zum Zitat Bowman A, Shunmugam M, Watts AR, Bramwell DC, Wilson C, Krishnan J. Inter-observer and intra-observer reliability of mechanical axis alignment before and after total knee arthroplasty using long leg radiographs. Knee. Elsevier B.V.; 2016;23:203–8. Bowman A, Shunmugam M, Watts AR, Bramwell DC, Wilson C, Krishnan J. Inter-observer and intra-observer reliability of mechanical axis alignment before and after total knee arthroplasty using long leg radiographs. Knee. Elsevier B.V.; 2016;23:203–8.
Metadaten
Titel
Fully automated deep learning for knee alignment assessment in lower extremity radiographs: a cross-sectional diagnostic study
verfasst von
Sebastian Simon
Gilbert M. Schwarz
Alexander Aichmair
Bernhard J. H. Frank
Allan Hummer
Matthew D. DiFranco
Martin Dominkus
Jochen G. Hofstaetter
Publikationsdatum
13.11.2021
Verlag
Springer Berlin Heidelberg
Erschienen in
Skeletal Radiology / Ausgabe 6/2022
Print ISSN: 0364-2348
Elektronische ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-021-03948-9

Neu im Fachgebiet Radiologie

Röntgen-Thorax oder LDCT fürs Lungenscreening nach HNSCC?

Personen, die an einem Plattenepithelkarzinom im Kopf-Hals-Bereich erkrankt sind, haben ein erhöhtes Risiko für Metastasen oder zweite Primärmalignome der Lunge. Eine Studie hat untersucht, wie die radiologische Überwachung aussehen sollte.

Statine: Was der G-BA-Beschluss für Praxen bedeutet

Nach dem G-BA-Beschluss zur erweiterten Verordnungsfähigkeit von Lipidsenkern rechnet die DEGAM mit 200 bis 300 neuen Dauerpatienten pro Praxis. Im Interview erläutert Präsidiumsmitglied Erika Baum, wie Hausärztinnen und Hausärzte am besten vorgehen.

Brustdichte nicht mit Multivitaminpräparat-Einnahme assoziiert

Der regelmäßige Gebrauch von Nahrungsergänzungsmitteln scheint nicht die mammografische Brustdichte zu erhöhen. In einer US-amerikanischen Studie jedenfalls ließ sich ein derartiger Zusammenhang nicht bestätigen.

Erhöhte Suizidrate unter US-Ärztinnen

Während der Arztberuf Männer eher vor Suizid schützt, erhöht er das Risiko bei Frauen – zumindest in den USA: Die Suizidinzidenz unter Ärztinnen ist um die Hälfte höher als unter Frauen mit anderen Berufen. Männliche Ärzte töten sich dennoch wesentlich häufiger selbst als weibliche.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.