Abstract

Purpose

Off-pump coronary artery bypass (OPCAB) is known to reduce operative morbidity, intensive care and hospital stay and blood usage. Recent reports have highlighted the poor results after off-pump coronary artery bypass. So, we decided to look at the angiographic patency of our patients at the end of 3 months.

Methods

Out of 265 patients who underwent isolated primary coronary artery bypass graft surgery (CABG) in a 2-year period at our institution, 118 are the subjects for this study. The anticoagulation and antiplatelet protocols are explained in detail. These patients underwent computerised tomography (CT) of coronary arteries to evaluate the graft patency. The results were studied by a competent radiologist with advanced Windows 4.7 workstation.

Results

There were 118 patients with a total of 380 anastomoses for evaluation. Twenty patients (16.95%) had some of their grafts blocked. Out of a total of 380 anastomoses, 24 were found to be blocked (6.3%). Left internal mammary artery had 98.3% patency. Left radial artery showed a patency rate of 96%. Saphenous vein grafts had a patency rate of 91.2%. The anterior and inferior territory grafts were patent in greater than 95% of patients, whereas lateral wall grafts were patent in 86% of patients. There was no mortality in this series. One patient reported angina. Fifty-eight patients had a treadmill test and 51 were negative and 7 had positive results for inducible ischemia.

Conclusions

OPCAB is a safe technique with acceptable clinical outcome and angiographic patency in experienced hands.
Literatur
1.
Zurück zum Zitat Wijeysundera DN, Beattie WS, Djaiani G, et al. Off pump coronary artery surgery for reducing mortality and morbidity – meta analysis of randomised and observational studies. J Am Coll Cardiol. 2005; 46:872–82. Wijeysundera DN, Beattie WS, Djaiani G, et al. Off pump coronary artery surgery for reducing mortality and morbidity – meta analysis of randomised and observational studies. J Am Coll Cardiol. 2005; 46:872–82.
2.
Zurück zum Zitat Ascione R, Lloyd CT, Underwood MJ, Lotto AA, Pitsis AA, Angelini GD. Economic outcome of off-pump coronary artery bypass surgery. A prospective randomised study. Ann Thorac Surg. 1999;68:2237–42. Ascione R, Lloyd CT, Underwood MJ, Lotto AA, Pitsis AA, Angelini GD. Economic outcome of off-pump coronary artery bypass surgery. A prospective randomised study. Ann Thorac Surg. 1999;68:2237–42.
3.
Zurück zum Zitat Puskas JD, Williams WH, Mahoney EM, et al. Off-pump vs conventional coronary artery bypass grafting: early and 1-year graft patency, cost and quality- of- life outcomes: a randomised trial. JAMA. 2004;291;1841–9. Puskas JD, Williams WH, Mahoney EM, et al. Off-pump vs conventional coronary artery bypass grafting: early and 1-year graft patency, cost and quality- of- life outcomes: a randomised trial. JAMA. 2004;291;1841–9.
4.
Zurück zum Zitat Nathoe HM, van Dijk D, Jansen EW, et al. A comparison of on-pump and off-pump coronary bypass surgery in low risk patients. N Engl J Med. 2003;348:394–402. Nathoe HM, van Dijk D, Jansen EW, et al. A comparison of on-pump and off-pump coronary bypass surgery in low risk patients. N Engl J Med. 2003;348:394–402.
5.
Zurück zum Zitat Cleveland JC Jr, Shroyer AL, Chen AY, Peterson E, Grover FL. Off-pump coronary artery bypass grafting decreases risk adjusted mortality and morbidity. Ann Thorac Surg. 2001;72:1282–8. Cleveland JC Jr, Shroyer AL, Chen AY, Peterson E, Grover FL. Off-pump coronary artery bypass grafting decreases risk adjusted mortality and morbidity. Ann Thorac Surg. 2001;72:1282–8.
6.
Zurück zum Zitat Keogh BE, Kinsman R. Fifth national adult cardiac surgical database report for 2003. Henley on Thames, United Kingdom: Dendrite clinical systems; 2004. Keogh BE, Kinsman R. Fifth national adult cardiac surgical database report for 2003. Henley on Thames, United Kingdom: Dendrite clinical systems; 2004.
7.
Zurück zum Zitat Sajja LR. The journey of surgery for coronary artery disease in India: Adoption,Customization and Innovation. Sadasivam Oration. Ind J Thorac Cardiovasc Surg. 2014;30:116–128. Sajja LR. The journey of surgery for coronary artery disease in India: Adoption,Customization and Innovation. Sadasivam Oration. Ind J Thorac Cardiovasc Surg. 2014;30:116–128.
8.
Zurück zum Zitat Sajja LR, Mannan G, Sompally S. Extrafascially harvested radial artery graft in CABG: technique of harvest, complications, and mid-term angiographic patency. J Card Surg. 2005;20:440–448. Sajja LR, Mannan G, Sompally S. Extrafascially harvested radial artery graft in CABG: technique of harvest, complications, and mid-term angiographic patency. J Card Surg. 2005;20:440–448.
9.
Zurück zum Zitat Widimsky P, Straka Z, Stros P, et al. One-Year coronary bypass graft patency – A randomised comparison between off-pump and on-pump surgery Angiographic results of the PRAGUE 4 Trial. Circulation. 2004;110:3418–3423. Widimsky P, Straka Z, Stros P, et al. One-Year coronary bypass graft patency – A randomised comparison between off-pump and on-pump surgery Angiographic results of the PRAGUE 4 Trial. Circulation. 2004;110:3418–3423.
10.
Zurück zum Zitat Lamy A, Devereaux PJ, Prabhakaran D, et al. Off-pump or on-pump coronary- artery bypass grafting at 30 days. N Engl J Med. 2012;366:1489–97. Lamy A, Devereaux PJ, Prabhakaran D, et al. Off-pump or on-pump coronary- artery bypass grafting at 30 days. N Engl J Med. 2012;366:1489–97.
11.
Zurück zum Zitat Lamy A, Devereaux PJ, Prabhakaran D, et al. Five-year outcomes after off-pump or on-pump coronary-artery bypass grafting. N Engl J Med. 2016;375:2359–68. Lamy A, Devereaux PJ, Prabhakaran D, et al. Five-year outcomes after off-pump or on-pump coronary-artery bypass grafting. N Engl J Med. 2016;375:2359–68.
12.
Zurück zum Zitat Hattler B, Messenger JC, Shroyer AL, et al. Off-pump coronary artery bypass surgery is associated with worse arterial and saphenous vein graft patency and less effective revascularisation. Results from the Veterans Affairs Randomised On/Off Bypass (ROOBY) Trial. Circulation. 2012;125:2827–2835. Hattler B, Messenger JC, Shroyer AL, et al. Off-pump coronary artery bypass surgery is associated with worse arterial and saphenous vein graft patency and less effective revascularisation. Results from the Veterans Affairs Randomised On/Off Bypass (ROOBY) Trial. Circulation. 2012;125:2827–2835.
13.
Zurück zum Zitat Houlind K, Fenger-Gron M, Holme SJ, et al. Graft Patency after off-pump coronary artery bypass surgery is inferior even with identical heparinisation protocols: Results from Danish on-pump versus off-pump randomisation study (DOORS). J Thorac Cardiovasc Surg. 2014;148:1812–9. Houlind K, Fenger-Gron M, Holme SJ, et al. Graft Patency after off-pump coronary artery bypass surgery is inferior even with identical heparinisation protocols: Results from Danish on-pump versus off-pump randomisation study (DOORS). J Thorac Cardiovasc Surg. 2014;148:1812–9.
14.
Zurück zum Zitat Angelini GD, Culliford L, Smith DK, et al. Effect of on- and off-pump coronary artery surgery on graft patency, survival and health related quality of life: Long-term follow-up of 2 randomized controlled trials. J Thorac Cardiovasc Surg. 2009;137:295–303. Angelini GD, Culliford L, Smith DK, et al. Effect of on- and off-pump coronary artery surgery on graft patency, survival and health related quality of life: Long-term follow-up of 2 randomized controlled trials. J Thorac Cardiovasc Surg. 2009;137:295–303.
15.
Zurück zum Zitat Diegler A, Borgermann J, Kappert U, et al. Off-Pump versus On-Pump Coronary-Artery Bypass Grafting in Elderly Patients N Engl J Med. 2013;368:1189–98. Diegler A, Borgermann J, Kappert U, et al. Off-Pump versus On-Pump Coronary-Artery Bypass Grafting in Elderly Patients N Engl J Med. 2013;368:1189–98.
16.
Zurück zum Zitat Nicolini F, Fortuna D, Contini GA, et al. Comparison between off and on-pump coronary artery bypass grafting: long-term results of a real world registry. Eur J Cardiothorac Surg. 2016;50:528–535. Nicolini F, Fortuna D, Contini GA, et al. Comparison between off and on-pump coronary artery bypass grafting: long-term results of a real world registry. Eur J Cardiothorac Surg. 2016;50:528–535.
17.
Zurück zum Zitat Fukui T, Tabata M, Manabe S, Shimokawa T, Takanashi S. Graft selection and one-year patency rates in patients undergoing coronary artery bypass grafting. Ann Thorac Surg. 2010;89:1901–5. Fukui T, Tabata M, Manabe S, Shimokawa T, Takanashi S. Graft selection and one-year patency rates in patients undergoing coronary artery bypass grafting. Ann Thorac Surg. 2010;89:1901–5.
18.
Zurück zum Zitat Goldman S, Zadina K, Moritz T, et al. Long-term patency of saphenous vein and left internal mammary artery grafts after coronary artery bypass surgery. Results from a Department of Veteran affairs cooperative study. J Am Coll Cardiol. 2004;44:2149–56. Goldman S, Zadina K, Moritz T, et al. Long-term patency of saphenous vein and left internal mammary artery grafts after coronary artery bypass surgery. Results from a Department of Veteran affairs cooperative study. J Am Coll Cardiol. 2004;44:2149–56.
19.
Zurück zum Zitat Yoo KJ, Choi D, Choi BW, Lim SH, Chang BC. The comparison of graft patency after coronary artery bypass grafting using coronary angiography and multi-slice computed tomography. Eur J Cardiothorac Surg. 2003;24:86–91. Yoo KJ, Choi D, Choi BW, Lim SH, Chang BC. The comparison of graft patency after coronary artery bypass grafting using coronary angiography and multi-slice computed tomography. Eur J Cardiothorac Surg. 2003;24:86–91.
20.
Zurück zum Zitat Yammamoto M, Kimura F, Niinami H, Suda Y, Ueno E, Takeuchi Y. Noninvasive assessment of off-pump coronary artery bypass surgery by 16-channel multidetector-row computed tomography. Ann Thorac Surg. 2006;81:820–7. Yammamoto M, Kimura F, Niinami H, Suda Y, Ueno E, Takeuchi Y. Noninvasive assessment of off-pump coronary artery bypass surgery by 16-channel multidetector-row computed tomography. Ann Thorac Surg. 2006;81:820–7.
21.
Zurück zum Zitat Bassri H, Salari F, Noohi F, et al. Evaluation of early graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography. BMC Cardiovasc Disord. 2009;9:53. Bassri H, Salari F, Noohi F, et al. Evaluation of early graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography. BMC Cardiovasc Disord. 2009;9:53.
Metadaten
Titel
Graft patency study in off-pump coronary artery bypass surgery
verfasst von
Arani Raghavendra Rao Raghuram
Krishnaswamy Subramanyan
Subbiah Sivakumaran
Purushothaman Chandrasekar
Subramanian Harikrishnan
Govindarajan Arunkumar
Publikationsdatum
29.08.2017
Verlag
Springer Singapore
Erschienen in
Indian Journal of Thoracic and Cardiovascular Surgery / Ausgabe 1/2018
Print ISSN: 0970-9134
Elektronische ISSN: 0973-7723
DOI
https://doi.org/10.1007/s12055-017-0587-x

Weitere Artikel der Ausgabe 1/2018

Indian Journal of Thoracic and Cardiovascular Surgery 1/2018 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.