Erschienen in: Oral and Maxillofacial Surgery 1/2021

29.07.2020 | Original Article

Healing at implants installed from ~ 70- to < 10-Ncm insertion torques: an experimental study in dogs

verfasst von: Mitsuo Kotsu, Joaquin Urbizo Velez, Franco Bengazi, Margherita Tumedei, Shigeo Fujiwara, Shingo Kato, Daniele Botticelli

Erschienen in: Oral and Maxillofacial Surgery | Ausgabe 1/2021

Einloggen, um Zugang zu erhalten

Abstract

Objective

To evaluate histologically the early healing at implants installed with different insertion torques

Material and methods

Three months after the extraction of the mandibular premolars and of the first molars, two implants were installed monolaterally in the premolar and two in the molar regions of the edentulous alveolar ridge of twelve dogs. The recipient sites were prepared using drills of different diameter to obtain insertion torque of different values, i.e., 30 Ncm (control) or ~ 70 Ncm (test) in the premolar region, and < 10 Ncm (test) or ~ 50 Ncm (control) in the molar region. Six animals were euthanized after 4 weeks and six after 8 weeks of healing. Histological analyses were performed, and the Wilcoxon test was applied for statistical analyses.

Results

After 4 weeks of healing, in the premolar region, the new bone in contact with the implant surface was 65.0 ± 4.6% and 53.9 ± 13.5% at the ~ 30-Ncm and ~ 70-Ncm sites, respectively (p = 0.075). In the premolar region, new bone proportions were 51.4 ± 17.0% and 67.3 ± 7.0% at the < 10-Ncm and ~ 50-Ncm sites, respectively (p = 0.046). After 8 weeks of healing, in the premolar region, new bone reached fractions of 77.7 ± 16.2% at the ~ 30-Ncm sites, and 68.3 ± 12.1% at the ~ 70-Ncm sites (p = 0.028). In the molar region, new bone presented proportions of 70.2 ± 6.4% at the < 10-Ncm sites and 76.2 ± 9.4% at the ~ 50-Ncm sites (p = 0.173).

Conclusions

The insertion torque influenced the osseointegration of implants. Higher values of bone-to-implant contact percentages were registered for insertion torques of ~ 30 Ncm and ~ 50 Ncm. Implants inserted with torque < 10 Ncm became integrated with an optimal osseointegration.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
3.
Zurück zum Zitat Cesaretti G, Botticelli D, Renzi A, Rossi M, Rossi R, Lang NP (2016) Radiographic evaluation of immediately loaded implants supporting 2-3 units fixed bridges in the posterior maxilla: a 3-year follow-up prospective randomized controlled multicenter clinical study. Clin Oral Implants Res 27(4):399–405. https://doi.org/10.1111/clr.12565CrossRefPubMed Cesaretti G, Botticelli D, Renzi A, Rossi M, Rossi R, Lang NP (2016) Radiographic evaluation of immediately loaded implants supporting 2-3 units fixed bridges in the posterior maxilla: a 3-year follow-up prospective randomized controlled multicenter clinical study. Clin Oral Implants Res 27(4):399–405. https://​doi.​org/​10.​1111/​clr.​12565CrossRefPubMed
8.
Zurück zum Zitat Trisi P, Todisco M, Consolo U, Travaglini D (2011) High versus low implant insertion torque: a histologic, histomorphometric, and biomechanical study in the sheep mandible. Int J Oral Maxillofac Implants 26:837–849PubMed Trisi P, Todisco M, Consolo U, Travaglini D (2011) High versus low implant insertion torque: a histologic, histomorphometric, and biomechanical study in the sheep mandible. Int J Oral Maxillofac Implants 26:837–849PubMed
10.
Zurück zum Zitat Brunski JB (1988) The influence of force, motion, and related quantities on the response of bone to implants. In: Fitzgerald R Jr (ed) Non cemented total hip arthroplasty. Raven Press, New York, p 43 Brunski JB (1988) The influence of force, motion, and related quantities on the response of bone to implants. In: Fitzgerald R Jr (ed) Non cemented total hip arthroplasty. Raven Press, New York, p 43
11.
Zurück zum Zitat Søballe K, Brockstedt-Rasmussen H, Hansen ES, Bünger C (1992) Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs. Acta Orthop Scand 63(2):128–140CrossRef Søballe K, Brockstedt-Rasmussen H, Hansen ES, Bünger C (1992) Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs. Acta Orthop Scand 63(2):128–140CrossRef
16.
26.
Zurück zum Zitat Russell WMS, Burch RL (1959) The principles of human experimental technique. Methuen, London Russell WMS, Burch RL (1959) The principles of human experimental technique. Methuen, London
29.
Zurück zum Zitat Balshi SF, Wolfinger GJ, Balshi TJ (2007) A retrospective analysis of 44 implants with no rotational primary stability used for fixed prosthesis anchorage. Int J Oral Maxillofac Implants 22(3):467–471PubMed Balshi SF, Wolfinger GJ, Balshi TJ (2007) A retrospective analysis of 44 implants with no rotational primary stability used for fixed prosthesis anchorage. Int J Oral Maxillofac Implants 22(3):467–471PubMed
33.
Zurück zum Zitat Norton MR (2011) The influence of insertion torque on the survival of immediately placed and restored single-tooth implants. Int J Oral Maxillofac Implants 26(6):1333–1343PubMed Norton MR (2011) The influence of insertion torque on the survival of immediately placed and restored single-tooth implants. Int J Oral Maxillofac Implants 26(6):1333–1343PubMed
Metadaten
Titel
Healing at implants installed from ~ 70- to < 10-Ncm insertion torques: an experimental study in dogs
verfasst von
Mitsuo Kotsu
Joaquin Urbizo Velez
Franco Bengazi
Margherita Tumedei
Shigeo Fujiwara
Shingo Kato
Daniele Botticelli
Publikationsdatum
29.07.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
Oral and Maxillofacial Surgery / Ausgabe 1/2021
Print ISSN: 1865-1550
Elektronische ISSN: 1865-1569
DOI
https://doi.org/10.1007/s10006-020-00890-3

Weitere Artikel der Ausgabe 1/2021

Oral and Maxillofacial Surgery 1/2021 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.