Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 7/2018

28.02.2018 | Original Paper

Healing score of the Xinsorb scaffold in the treatment of de novo lesions: 6-month imaging outcomes

verfasst von: Xucheng Lv, Li Shen, Yizhe Wu, Lei Ge, Jiahui Chen, Jiasheng Yin, Rui Wang, Meng Ji, Bin Hong, Junbo Ge

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 7/2018

Einloggen, um Zugang zu erhalten

Abstract

The objectives of this study are to assess the healing score (HS) and neointimal thickness of the Xinsorb scaffold, and explore the relationships between the implanted patterns, neointimal thickness, and HS. The Xinsorb bioresorbable sirolimus-eluting scaffold is the first domestically designed and fabricated bioresorbable scaffold in China. The 6-month follow-up found it to be safe and effective in the treatment of single de novo coronary lesions. The Xinsorb scaffolds were implanted in 30 patients with symptomatic ischemic coronary disease. A 6-month follow-up was performed in a subset of 19 patients; the HS and neointimal thickness were evaluated by optical coherence tomography. Struts were classified as ApposedCovered, ApposedUncovered, MalapposedCovered, MalapposedUncovered, jailing and presence of intraluminal masses. The implanted pressure, implanted duration, and post-expansion pressure were recorded during the operation. We evaluated the relationship between the HS or neointimal thickness and the implanted pressure, holding time, and post-expansion pressure. The device and procedure success rates were both 100%. No major adverse cardiac or scaffold-thrombus related events occurred. At 6 months, 12,295 struts were analyzed to determine the HS (6.23) and neointimal thickness (0.1021 ± 0.05718 mm) in the Xinsorb scaffolds. There was a strong negative relationship between the HS and the implantation duration (Pearson r = − 0.518, p = 0.023). A significant negative relationship also existed between the HS and post-dilatation (Pearson r = − 0.631, p = 0.004). The Xinsorb scaffold HS appears negative correlated with the implanted duration and post-dilatation. We will further evaluate the HS of randomized controlled trial of the Xissorb scaffold.
Literatur
1.
Zurück zum Zitat Ellis SG, Kereiakes DJ, Metzger DC et al (2015) Everolimus-eluting bioresorbable scaffolds for coronary artery disease. N Engl J Med 373(20):1905–1915CrossRefPubMed Ellis SG, Kereiakes DJ, Metzger DC et al (2015) Everolimus-eluting bioresorbable scaffolds for coronary artery disease. N Engl J Med 373(20):1905–1915CrossRefPubMed
2.
Zurück zum Zitat Wu Y, Shen L, Wang Q et al (2012) Comparison of acute recoil between bioabsorbable poly-L-lactic acid XINSORB scaffold and metallic stent in porcine model. J Biomed Biotechnol 2012:413956PubMedPubMedCentral Wu Y, Shen L, Wang Q et al (2012) Comparison of acute recoil between bioabsorbable poly-L-lactic acid XINSORB scaffold and metallic stent in porcine model. J Biomed Biotechnol 2012:413956PubMedPubMedCentral
3.
Zurück zum Zitat Shen L, Wang Q Wu Y et al (2012) Short-term effects of fully bioabsorbable PLLA coronary stents in a porcine model. Polym Bull 68:1171–1181CrossRef Shen L, Wang Q Wu Y et al (2012) Short-term effects of fully bioabsorbable PLLA coronary stents in a porcine model. Polym Bull 68:1171–1181CrossRef
4.
Zurück zum Zitat Shen L, Wu Y, Ge L et al (2017) A head to head comparison of XINSORB bioresorbable sirolimus-eluting scaffold versus metallic sirolimus-eluting stent: 180 days follow-up in a porcine model. Int J Cardiovasc Imag 10:1473–1481CrossRef Shen L, Wu Y, Ge L et al (2017) A head to head comparison of XINSORB bioresorbable sirolimus-eluting scaffold versus metallic sirolimus-eluting stent: 180 days follow-up in a porcine model. Int J Cardiovasc Imag 10:1473–1481CrossRef
5.
Zurück zum Zitat Chen JH, Wu YZ, Shen L et al (2015) First-in-man Implantation of the Xinsorb bioresorbable sirolimus eluting scaffold in China. Chin Med J (Engl) 128(9):1275–1276CrossRef Chen JH, Wu YZ, Shen L et al (2015) First-in-man Implantation of the Xinsorb bioresorbable sirolimus eluting scaffold in China. Chin Med J (Engl) 128(9):1275–1276CrossRef
6.
Zurück zum Zitat Wu Y, Shen L, Ge L et al (2016) Six-month outcomes of the XINSORB bioresorbable sirolimus-eluting scaffold in treating single de novo lesions in human coronary artery. Catheter Cardiovas Interv 87(S1):630–637CrossRef Wu Y, Shen L, Ge L et al (2016) Six-month outcomes of the XINSORB bioresorbable sirolimus-eluting scaffold in treating single de novo lesions in human coronary artery. Catheter Cardiovas Interv 87(S1):630–637CrossRef
7.
Zurück zum Zitat de Ribamar Costa J Jr, Mintz GS, Carlier SG et al (2007) Intravascular ultrasound assessment of drug-eluting stent expansion. Am Heart J 153(2):297–303CrossRefPubMed de Ribamar Costa J Jr, Mintz GS, Carlier SG et al (2007) Intravascular ultrasound assessment of drug-eluting stent expansion. Am Heart J 153(2):297–303CrossRefPubMed
8.
Zurück zum Zitat Yamaji K, Räber L, Windecker S (2017) What determines long-term outcomes using fully bioresorbable scaffolds—the device, the operator or the lesion? EuroIntervention 12:1684–1687CrossRefPubMed Yamaji K, Räber L, Windecker S (2017) What determines long-term outcomes using fully bioresorbable scaffolds—the device, the operator or the lesion? EuroIntervention 12:1684–1687CrossRefPubMed
9.
Zurück zum Zitat Serruys PW, Onuma Y (2017) Dmax for sizing, PSP-1, PSP-2, PSP-3 or OCT guidance: interventionalist’s jargon or indispensable implantation techniques for short- and long-term outcomes of Absorb BRS? Eurointervention 12:2047–2056CrossRefPubMed Serruys PW, Onuma Y (2017) Dmax for sizing, PSP-1, PSP-2, PSP-3 or OCT guidance: interventionalist’s jargon or indispensable implantation techniques for short- and long-term outcomes of Absorb BRS? Eurointervention 12:2047–2056CrossRefPubMed
10.
Zurück zum Zitat Puricel S, Cuculi F, Weissner M et al (2016) Bioresorbable coronary scaffold thrombosis: multicenter comprehensive analysis of clinical presentation, mechanisms, and predictors. J Am Coll Cardiol 67(8):921–931CrossRefPubMed Puricel S, Cuculi F, Weissner M et al (2016) Bioresorbable coronary scaffold thrombosis: multicenter comprehensive analysis of clinical presentation, mechanisms, and predictors. J Am Coll Cardiol 67(8):921–931CrossRefPubMed
11.
Zurück zum Zitat Garcíagarcía HM, Muramatsu T, Nakatani S et al (2014) Serial optical frequency domain imaging in STEMI patients: the follow-up report of TROFI study. Eur Heart J Cardiovasc Imag 15(9):987–995CrossRef Garcíagarcía HM, Muramatsu T, Nakatani S et al (2014) Serial optical frequency domain imaging in STEMI patients: the follow-up report of TROFI study. Eur Heart J Cardiovasc Imag 15(9):987–995CrossRef
12.
Zurück zum Zitat Raber L, Onuma Y, Brugaletta S et al (2015) Arterial healing following primary PCI using the Absorb everolimus-eluting bioresorbable vascular scaffold (Absorb BVS) versus the durable polymer everolimus-eluting metallic stent (XIENCE) in patients with acute ST-elevation myocardial infarction: rationale and design of the randomised TROFI II study. EuroIntervention 12:482–489CrossRef Raber L, Onuma Y, Brugaletta S et al (2015) Arterial healing following primary PCI using the Absorb everolimus-eluting bioresorbable vascular scaffold (Absorb BVS) versus the durable polymer everolimus-eluting metallic stent (XIENCE) in patients with acute ST-elevation myocardial infarction: rationale and design of the randomised TROFI II study. EuroIntervention 12:482–489CrossRef
13.
Zurück zum Zitat Suwannasom P, Onuma Y, Benit E et al (2016) Evaluation of vascular healing of polymer-free sirolimus-eluting stents in native coronary artery stenosis: a serial follow-up at three and six months with optical coherence tomography imaging. Eurointervention 12(5):e574CrossRefPubMed Suwannasom P, Onuma Y, Benit E et al (2016) Evaluation of vascular healing of polymer-free sirolimus-eluting stents in native coronary artery stenosis: a serial follow-up at three and six months with optical coherence tomography imaging. Eurointervention 12(5):e574CrossRefPubMed
14.
Zurück zum Zitat Gonzalo N, Garciagarcia HM, Serruys PW et al (2009) Reproducibility of quantitative optical coherence tomography for stent analysis. Eurointervention 5(2):224–232CrossRefPubMed Gonzalo N, Garciagarcia HM, Serruys PW et al (2009) Reproducibility of quantitative optical coherence tomography for stent analysis. Eurointervention 5(2):224–232CrossRefPubMed
15.
Zurück zum Zitat Muramatsu T, Garcia-Garcia HM, Lee IS et al (2012) Quantitative optical frequency domain imaging assessment of in-stent structures in patients with ST-segment elevation myocardial infarction. Circ J 76:2822–2831CrossRefPubMed Muramatsu T, Garcia-Garcia HM, Lee IS et al (2012) Quantitative optical frequency domain imaging assessment of in-stent structures in patients with ST-segment elevation myocardial infarction. Circ J 76:2822–2831CrossRefPubMed
16.
Zurück zum Zitat Onuma Y, Thuesen L, van Geuns RJ et al (2013) Randomized study to assess the effect of thrombus aspiration on flow area in patients with ST-elevation myocardial infarction: an optical frequency domain imaging study—TROFI trial. Eur Heart J 34:1050–1060CrossRefPubMed Onuma Y, Thuesen L, van Geuns RJ et al (2013) Randomized study to assess the effect of thrombus aspiration on flow area in patients with ST-elevation myocardial infarction: an optical frequency domain imaging study—TROFI trial. Eur Heart J 34:1050–1060CrossRefPubMed
17.
Zurück zum Zitat Gonzalo N, Serruys PW, Okamura T et al (2009) Optical coherence tomography assessment of the acute effects of stent implantation on the vessel wall: a systematic quantitative approach. Heart 95:1913–1919CrossRefPubMed Gonzalo N, Serruys PW, Okamura T et al (2009) Optical coherence tomography assessment of the acute effects of stent implantation on the vessel wall: a systematic quantitative approach. Heart 95:1913–1919CrossRefPubMed
18.
Zurück zum Zitat Gomez-Lara J, Radu M, Brugaletta S et al (2011) Serial analysis of the malapposed and uncovered struts of the new generation of everolimus-eluting bioresorbable scaffold with optical coherence tomography. JACC Cardiovasc Interv 4(9):992–1001CrossRefPubMed Gomez-Lara J, Radu M, Brugaletta S et al (2011) Serial analysis of the malapposed and uncovered struts of the new generation of everolimus-eluting bioresorbable scaffold with optical coherence tomography. JACC Cardiovasc Interv 4(9):992–1001CrossRefPubMed
19.
Zurück zum Zitat Pfisterer M, BrunnerLa Rocca HP, Buser PT et al (2007) Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting stents: an observational study of drug-eluting versus bare-metal stents. J Am Coll Cardiol 48(12):2584–2591CrossRef Pfisterer M, BrunnerLa Rocca HP, Buser PT et al (2007) Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting stents: an observational study of drug-eluting versus bare-metal stents. J Am Coll Cardiol 48(12):2584–2591CrossRef
20.
Zurück zum Zitat Sabaté M, Windecker S, Iñiguez A et al (2016) Everolimus-eluting bioresorbable stent vs. durable polymer everolimus-eluting metallic stent in patients with ST-segment elevation myocardial infarction: results of the randomized ABSORB ST-segment elevation myocardial infarction-TROFI II trial. Eur Heart J 37(3):229–240CrossRefPubMed Sabaté M, Windecker S, Iñiguez A et al (2016) Everolimus-eluting bioresorbable stent vs. durable polymer everolimus-eluting metallic stent in patients with ST-segment elevation myocardial infarction: results of the randomized ABSORB ST-segment elevation myocardial infarction-TROFI II trial. Eur Heart J 37(3):229–240CrossRefPubMed
21.
Zurück zum Zitat Yamaji K, Brugaletta S, Sabaté M et al (2017) Effect of post-dilatation following primary PCI with everolimus-eluting bioresorbable scaffold versus everolimus-eluting metallic stent implantation: an angiographic and optical coherence tomography TROFI II substudy. JACC Cardiovasc Interv 10(18):1867–1877CrossRefPubMed Yamaji K, Brugaletta S, Sabaté M et al (2017) Effect of post-dilatation following primary PCI with everolimus-eluting bioresorbable scaffold versus everolimus-eluting metallic stent implantation: an angiographic and optical coherence tomography TROFI II substudy. JACC Cardiovasc Interv 10(18):1867–1877CrossRefPubMed
Metadaten
Titel
Healing score of the Xinsorb scaffold in the treatment of de novo lesions: 6-month imaging outcomes
verfasst von
Xucheng Lv
Li Shen
Yizhe Wu
Lei Ge
Jiahui Chen
Jiasheng Yin
Rui Wang
Meng Ji
Bin Hong
Junbo Ge
Publikationsdatum
28.02.2018
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 7/2018
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-018-1326-0

Weitere Artikel der Ausgabe 7/2018

The International Journal of Cardiovascular Imaging 7/2018 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.