Skip to main content
Erschienen in:

06.11.2019 | KNEE

High congruency MB insert design: stabilizing knee joint even with PCL deficiency

verfasst von: Bernardo Innocenti

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 9/2020

Einloggen, um Zugang zu erhalten

Abstract

Purpose

PCL management and choice of insert design and mobility in total knee arthroplasty are still debated in the literature. Consequently, the purpose of this study was to analyze the biomechanics of a fixed and a mobile bearing total knee arthroplasty with conventional and ultra-congruent insert during walking and squat activities, using finite element analysis, and to check the performance in a knee with healthy and deficient PCL.

Methods

The study was based on an already validated and published knee model. Fixed bearing and mobile bearing cruciate-retain designs were selected for this study. Implant kinematics and kinetics were calculated, following previously experimental tests, during a walking cycle and a loaded squat in a knee with intact and with deficient PCL.

Results

Mobile bearing design, due to its higher congruency, was able to complete the task in intact and deficient PCL conditions, with similar internal–external femoral rotation and with a slight higher anterior translation of the one of the intact knees. Such outcomes were also in agreement with the results of different experimental studies of native knee specimens under similar boundary conditions. Contrariwise, fixed bearing design was able to accomplish the task only in healthy PCL conditions.

Conclusion

Results demonstrated how the high congruency of the mobile bearing design is able to guarantee proper knee stability and kinematics even when the PCL is deficient. Instead, the fixed bearing insert, with lower congruency, is not able, in the absence of the PCL, to stabilize the joint inducing irregular kinematic pattern and component dislocation. Surgeons will have to consider these findings to guarantee the best outcome for the patient and the related change in stability in case of PCL deficiency.
Literatur
1.
Zurück zum Zitat Andriacchi TP, Galante JO, Fermier RW (1982) The influence of total knee-replacement design on walking and stair-climbing. J Bone Jt Surg Am 64(9):1328–1335 Andriacchi TP, Galante JO, Fermier RW (1982) The influence of total knee-replacement design on walking and stair-climbing. J Bone Jt Surg Am 64(9):1328–1335
2.
Zurück zum Zitat Arnout N, Vanlommel L, Vanlommel J, Luyckx JP, Labey L, Innocenti B, Victor J, Bellemans J (2015) Post-cam mechanics and tibiofemoral kinematics: a dynamic in vitro analysis of eight posterior-stabilized total knee designs. Knee Surg Sports Traumatol Arthrosc 23(11):3343–3353PubMed Arnout N, Vanlommel L, Vanlommel J, Luyckx JP, Labey L, Innocenti B, Victor J, Bellemans J (2015) Post-cam mechanics and tibiofemoral kinematics: a dynamic in vitro analysis of eight posterior-stabilized total knee designs. Knee Surg Sports Traumatol Arthrosc 23(11):3343–3353PubMed
3.
Zurück zum Zitat Au AG, James Raso V, Liggins AB, Amrfazli A (2007) Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacements. J Biomech 40(6):1410–1416PubMed Au AG, James Raso V, Liggins AB, Amrfazli A (2007) Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacements. J Biomech 40(6):1410–1416PubMed
4.
Zurück zum Zitat Belvedere C, Leardini A, Catani F, Pianigiani S, Innocenti B (2017) In vivo kinematics of knee replacement during daily living activities: condylar and post-cam contact assessment by three-dimensional fluoroscopy and finite element analyses. J Orthop Res 35(7):1396–1403PubMed Belvedere C, Leardini A, Catani F, Pianigiani S, Innocenti B (2017) In vivo kinematics of knee replacement during daily living activities: condylar and post-cam contact assessment by three-dimensional fluoroscopy and finite element analyses. J Orthop Res 35(7):1396–1403PubMed
5.
Zurück zum Zitat Brihault J, Navacchia A, Pianigiani S, Labey L, De Corte R, Pascale V, Innocenti B (2016) All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 24(8):2550–2559PubMed Brihault J, Navacchia A, Pianigiani S, Labey L, De Corte R, Pascale V, Innocenti B (2016) All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 24(8):2550–2559PubMed
6.
Zurück zum Zitat Capella M, Dolfin M, Saccia F (2016) Mobile bearing and fixed bearing total knee arthroplasty. Ann Transl Med 4(7):127PubMedPubMedCentral Capella M, Dolfin M, Saccia F (2016) Mobile bearing and fixed bearing total knee arthroplasty. Ann Transl Med 4(7):127PubMedPubMedCentral
7.
Zurück zum Zitat Castellarin G, Pianigiani S, Innocenti B (2019) Asymmetric polyethylene inserts promote favorable kinematics and better clinical outcome compared to symmetric inserts in a mobile bearing total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 27(4):1096–1105PubMed Castellarin G, Pianigiani S, Innocenti B (2019) Asymmetric polyethylene inserts promote favorable kinematics and better clinical outcome compared to symmetric inserts in a mobile bearing total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 27(4):1096–1105PubMed
8.
Zurück zum Zitat Catani F, Belvedere C, Ensini A, Feliciangeli A, Giannini S, Leardini A (2011) In-vivo knee kinematics in rotationally unconstrained total knee arthroplasty. J Orthop Res 29(10):1484–1490PubMed Catani F, Belvedere C, Ensini A, Feliciangeli A, Giannini S, Leardini A (2011) In-vivo knee kinematics in rotationally unconstrained total knee arthroplasty. J Orthop Res 29(10):1484–1490PubMed
9.
Zurück zum Zitat Catani F, Ensini A, Belvedere C, Feliciangeli A, Benedetti MG, Leardini A, Giannini S (2009) In vivo kinematics and kinetics of a bi-cruciate substituting total knee arthroplasty: a combined fluoroscopic and gait analysis study. J Orthop Res 27(12):1569–1575PubMed Catani F, Ensini A, Belvedere C, Feliciangeli A, Benedetti MG, Leardini A, Giannini S (2009) In vivo kinematics and kinetics of a bi-cruciate substituting total knee arthroplasty: a combined fluoroscopic and gait analysis study. J Orthop Res 27(12):1569–1575PubMed
10.
Zurück zum Zitat Catani F, Leardini A, Ensini A, Cucca G, Bragonzoni L, Toksvig-Larsen S, Giannini S (2004) The stability of the cemented tibial component of total knee arthroplasty: posterior cruciate retaining versus posterior-stabilized design. J Arthroplast 19(6):775–782 Catani F, Leardini A, Ensini A, Cucca G, Bragonzoni L, Toksvig-Larsen S, Giannini S (2004) The stability of the cemented tibial component of total knee arthroplasty: posterior cruciate retaining versus posterior-stabilized design. J Arthroplast 19(6):775–782
11.
Zurück zum Zitat El-Zayat BF, Heyse TJ, Fanciullacci N, Labey L, Fuchs-Winkelmann S, Innocenti B (2016) Fixation techniques and stem dimensions in hinged total knee arthroplasty: a finite element study. Arch Orthop Trauma Surg 136(12):1741–1752PubMed El-Zayat BF, Heyse TJ, Fanciullacci N, Labey L, Fuchs-Winkelmann S, Innocenti B (2016) Fixation techniques and stem dimensions in hinged total knee arthroplasty: a finite element study. Arch Orthop Trauma Surg 136(12):1741–1752PubMed
12.
Zurück zum Zitat Ewald FC, Jacobs MA, Miegel RE, Walker PS, Poss R, Sledge CB (1984) Kinematic total knee replacement. J Bone Jt Surg Am 66(7):1032–1040 Ewald FC, Jacobs MA, Miegel RE, Walker PS, Poss R, Sledge CB (1984) Kinematic total knee replacement. J Bone Jt Surg Am 66(7):1032–1040
13.
Zurück zum Zitat Godest AC, Beaugonin M, Haug E, Taylor M, Gregson PJ (2002) Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis. J Biomech 35(2):267–275PubMed Godest AC, Beaugonin M, Haug E, Taylor M, Gregson PJ (2002) Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis. J Biomech 35(2):267–275PubMed
14.
Zurück zum Zitat Harner CD, Xerogeanes JW, Livesay GA, Carlin GJ, Smith GJ, Kusayama T, Kashiwaguchi S, Woo SL (1995) The human posterior cruciate ligament complex: an interdisciplinary study. Ligament morphology and biomechanical evaluation. Am J Sports Med 23(6):736–745PubMed Harner CD, Xerogeanes JW, Livesay GA, Carlin GJ, Smith GJ, Kusayama T, Kashiwaguchi S, Woo SL (1995) The human posterior cruciate ligament complex: an interdisciplinary study. Ligament morphology and biomechanical evaluation. Am J Sports Med 23(6):736–745PubMed
15.
Zurück zum Zitat Hazratwala K, Matthews B, Wilkinson M, Barroso-Rosa S (2016) Total knee arthroplasty in patients with extra-articular deformity. Arthroplast Today. 2(1):26–36PubMedPubMedCentral Hazratwala K, Matthews B, Wilkinson M, Barroso-Rosa S (2016) Total knee arthroplasty in patients with extra-articular deformity. Arthroplast Today. 2(1):26–36PubMedPubMedCentral
16.
Zurück zum Zitat Heiner AD, Brown TD (2001) Structural properties of a new design of composite replicate femurs and tibias. J Biomech 34(6):773–781PubMed Heiner AD, Brown TD (2001) Structural properties of a new design of composite replicate femurs and tibias. J Biomech 34(6):773–781PubMed
17.
Zurück zum Zitat In Y, Kim JM, Woo YK, Choi NY, Sohn JM, Koh HS (2009) Factors affecting flexion gap tightness in cruciate-retaining total knee arthroplasty. J Arthroplast 24(2):317–321 In Y, Kim JM, Woo YK, Choi NY, Sohn JM, Koh HS (2009) Factors affecting flexion gap tightness in cruciate-retaining total knee arthroplasty. J Arthroplast 24(2):317–321
18.
Zurück zum Zitat Ingrassia T, Nalbone L, Nigrelli V, Tumino V, Ricotta V (2013) Finite element analysis of two total knee prostheses. Int J Interact Des Manuf 7(2):91–101 Ingrassia T, Nalbone L, Nigrelli V, Tumino V, Ricotta V (2013) Finite element analysis of two total knee prostheses. Int J Interact Des Manuf 7(2):91–101
19.
Zurück zum Zitat Innocenti B, Bilgen ÖF, Labey L, van Lenthe GH, Sloten JV, Catani FC (2014) Load sharing and ligament strains in balanced, overstuffed and understuffed UKA. A validated finite element analysis. J Arthroplast 29(7):1491–1498 Innocenti B, Bilgen ÖF, Labey L, van Lenthe GH, Sloten JV, Catani FC (2014) Load sharing and ligament strains in balanced, overstuffed and understuffed UKA. A validated finite element analysis. J Arthroplast 29(7):1491–1498
20.
Zurück zum Zitat Innocenti B, Bellemans J, Catani F (2016) Deviations from optimal alignment in TKA: is there a biomechanical difference between femoral or tibial component alignment? J Arthroplast 31(1):295–301 Innocenti B, Bellemans J, Catani F (2016) Deviations from optimal alignment in TKA: is there a biomechanical difference between femoral or tibial component alignment? J Arthroplast 31(1):295–301
21.
Zurück zum Zitat Innocenti B, Pianigiani S, Labey L, Victor J, Bellemans J (2011) Contact forces in several TKA designs during squatting: a numerical sensitivity analysis. J Biomech 44(8):1573–1581PubMed Innocenti B, Pianigiani S, Labey L, Victor J, Bellemans J (2011) Contact forces in several TKA designs during squatting: a numerical sensitivity analysis. J Biomech 44(8):1573–1581PubMed
22.
Zurück zum Zitat Innocenti B, Pianigiani S, Ramundo G, Thienpont E (2017) Biomechanical effects of different varus and valgus alignments in medial unicompartmental knee arthroplasty. J Arthroplast 31(12):2685–2691 Innocenti B, Pianigiani S, Ramundo G, Thienpont E (2017) Biomechanical effects of different varus and valgus alignments in medial unicompartmental knee arthroplasty. J Arthroplast 31(12):2685–2691
23.
Zurück zum Zitat Innocenti B, Robledo H, Bernabe R, Pianigiani S (2015) Investigation on the effects induced by TKA features on tibio-femoral mechanics. Part I: femoral component designs. J Mech Med Biol 15(2):1540034 Innocenti B, Robledo H, Bernabe R, Pianigiani S (2015) Investigation on the effects induced by TKA features on tibio-femoral mechanics. Part I: femoral component designs. J Mech Med Biol 15(2):1540034
24.
Zurück zum Zitat Innocenti B, Salandra P, Pascale W, Pianigiani S (2016) How accurate and reproducible are the identification of cruciate and collateral ligament insertions using MRI? Knee 23(4):575–581PubMed Innocenti B, Salandra P, Pascale W, Pianigiani S (2016) How accurate and reproducible are the identification of cruciate and collateral ligament insertions using MRI? Knee 23(4):575–581PubMed
25.
Zurück zum Zitat Innocenti B, Truyens E, Labey L, Wong P, Victor J, Bellemans J (2009) Can medio-lateral baseplate position and load sharing induce asymptomatic local bone resorption of the proximal tibia? A finite element study. J Orthop Surg Res 4:26PubMedPubMedCentral Innocenti B, Truyens E, Labey L, Wong P, Victor J, Bellemans J (2009) Can medio-lateral baseplate position and load sharing induce asymptomatic local bone resorption of the proximal tibia? A finite element study. J Orthop Surg Res 4:26PubMedPubMedCentral
26.
Zurück zum Zitat Insall JN, Hood RW, Flawn LB, Sullivan DJ (1983) The total condylar knee prosthesis in gonarthrosis. A five to nine-year follow-up of the first one hundred consecutive replacements. J Bone Jt Surg Am 65(5):619–628 Insall JN, Hood RW, Flawn LB, Sullivan DJ (1983) The total condylar knee prosthesis in gonarthrosis. A five to nine-year follow-up of the first one hundred consecutive replacements. J Bone Jt Surg Am 65(5):619–628
27.
Zurück zum Zitat Kelman GJ, Biden EN, Wyatt MP, Ritter MA, Colwell CW Jr (1999) Gait laboratory analysis of a posterior cruciate-sparing total knee arthroplasty in stair ascent and descent. Clin Orthop Relat Res 248:21–25 Kelman GJ, Biden EN, Wyatt MP, Ritter MA, Colwell CW Jr (1999) Gait laboratory analysis of a posterior cruciate-sparing total knee arthroplasty in stair ascent and descent. Clin Orthop Relat Res 248:21–25
28.
Zurück zum Zitat Kim H, Pelker RR, Gibson DH, Irving JF, Lynch JK (1997) Rollback in posterior cruciate ligament-retaining total knee arthroplasty. A radiographic analysis. J Arthroplast 12(5):553–561 Kim H, Pelker RR, Gibson DH, Irving JF, Lynch JK (1997) Rollback in posterior cruciate ligament-retaining total knee arthroplasty. A radiographic analysis. J Arthroplast 12(5):553–561
29.
Zurück zum Zitat Kwak SD, Ahmad CS, Gardner TR, Grelsamer RP, Henry JH, Blankevoort L, Ateshian GA, Mow VC (2000) Hamstrings and iliotibial band forces affect knee kinematics and contact pattern. J Orthop Res 18(1):101–108PubMed Kwak SD, Ahmad CS, Gardner TR, Grelsamer RP, Henry JH, Blankevoort L, Ateshian GA, Mow VC (2000) Hamstrings and iliotibial band forces affect knee kinematics and contact pattern. J Orthop Res 18(1):101–108PubMed
30.
Zurück zum Zitat Laskin RS, Maruyama Y, Villaneuva M, Bourne R (2000) Deep-dish congruent tibial component use in total knee arthroplasty: a randomized prospective study. Clin Orthop Relat Res 380:36–44 Laskin RS, Maruyama Y, Villaneuva M, Bourne R (2000) Deep-dish congruent tibial component use in total knee arthroplasty: a randomized prospective study. Clin Orthop Relat Res 380:36–44
31.
Zurück zum Zitat Li G, Most E, Otterberg E, Sabbag K, Zayontz S, Johnson T, Rubash H (2002) Biomechanics of posterior-substituting total knee arthroplasty: an in vitro study. Clin Orthop Relat Res 404:214–225 Li G, Most E, Otterberg E, Sabbag K, Zayontz S, Johnson T, Rubash H (2002) Biomechanics of posterior-substituting total knee arthroplasty: an in vitro study. Clin Orthop Relat Res 404:214–225
32.
Zurück zum Zitat Luyckx T, Didden K, Vandenneucker H, Labey L, Innocenti B, Bellemans J (2009) Is there a biomechanical explanation for anterior knee pain in patients with patella alta? Influence of patellar height on patellofemoral contact force, contact area and contact pressure. J Bone Jt Surg (Br) 91(3):344–350 Luyckx T, Didden K, Vandenneucker H, Labey L, Innocenti B, Bellemans J (2009) Is there a biomechanical explanation for anterior knee pain in patients with patella alta? Influence of patellar height on patellofemoral contact force, contact area and contact pressure. J Bone Jt Surg (Br) 91(3):344–350
33.
Zurück zum Zitat Maniar R (2006) Rationale for the posterior-stabilized rotating platform knee. Orthopedics 29(9):S23–27PubMed Maniar R (2006) Rationale for the posterior-stabilized rotating platform knee. Orthopedics 29(9):S23–27PubMed
34.
Zurück zum Zitat Mazzucchelli L, Deledda D, Rosso F, Ratto N, Bruzzone M, Bonasia DE, Rossi R (2016) Cruciate retaining and cruciate substituting ultra-congruent insert. Ann Transl Med 4(1):2PubMedPubMedCentral Mazzucchelli L, Deledda D, Rosso F, Ratto N, Bruzzone M, Bonasia DE, Rossi R (2016) Cruciate retaining and cruciate substituting ultra-congruent insert. Ann Transl Med 4(1):2PubMedPubMedCentral
35.
Zurück zum Zitat Moskal JT, Capp SG (2014) Rotating-platform TKA no different from fixed-bearing TKA regarding survivorship or performance: a meta-analysis. Clin Orthop Relat Res 472:2185–2193PubMedPubMedCentral Moskal JT, Capp SG (2014) Rotating-platform TKA no different from fixed-bearing TKA regarding survivorship or performance: a meta-analysis. Clin Orthop Relat Res 472:2185–2193PubMedPubMedCentral
36.
Zurück zum Zitat Most E, Zayontz S, Li G, Otterberg E, Sabbag K, Rubash HE (2003) Femoral rollback after cruciate-retaining and stabilizing total knee arthroplasty. Clin Orthop Relat Res 410:101–113 Most E, Zayontz S, Li G, Otterberg E, Sabbag K, Rubash HE (2003) Femoral rollback after cruciate-retaining and stabilizing total knee arthroplasty. Clin Orthop Relat Res 410:101–113
37.
Zurück zum Zitat Nakayama K, Matsuda S, Miura H, Iwamoto Y, Higaki H, Otsuka K (2005) Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplasty. J Bone Jt Surg Br 87(4):483–488 Nakayama K, Matsuda S, Miura H, Iwamoto Y, Higaki H, Otsuka K (2005) Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplasty. J Bone Jt Surg Br 87(4):483–488
38.
Zurück zum Zitat Paratte S, Pagnano MW, Trousdale RT, Berry DJ (2010) Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Jt Surg Am 92(12):2143–2149 Paratte S, Pagnano MW, Trousdale RT, Berry DJ (2010) Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Jt Surg Am 92(12):2143–2149
39.
Zurück zum Zitat Peters CL, Mulkey P, Erickson J, Anderson MB, Pelt CE (2014) Comparison of total knee arthroplasty with highly congruent anterior-stabilized bearings versus a cruciate-retaining design. Clin Orthop Relat Res 472:175–180PubMed Peters CL, Mulkey P, Erickson J, Anderson MB, Pelt CE (2014) Comparison of total knee arthroplasty with highly congruent anterior-stabilized bearings versus a cruciate-retaining design. Clin Orthop Relat Res 472:175–180PubMed
40.
Zurück zum Zitat Pianigiani S, Alario Bernabé R, Robledo Yagüe H, Innocenti B (2015) Investigation on the effects induced by TKA features on tibio-femoral mechanics part II: tibial insert designs. J Mech Med Biol 15(2):1540035 Pianigiani S, Alario Bernabé R, Robledo Yagüe H, Innocenti B (2015) Investigation on the effects induced by TKA features on tibio-femoral mechanics part II: tibial insert designs. J Mech Med Biol 15(2):1540035
41.
Zurück zum Zitat Pianigiani S, Chevalier Y, Labey L, Pascale V, Innocenti B (2012) Tibio-femoral kinematics in different total knee arthroplasty designs during a loaded squat: a numerical sensitivity study. J Biomech 45(13):2315–2323PubMed Pianigiani S, Chevalier Y, Labey L, Pascale V, Innocenti B (2012) Tibio-femoral kinematics in different total knee arthroplasty designs during a loaded squat: a numerical sensitivity study. J Biomech 45(13):2315–2323PubMed
42.
Zurück zum Zitat Pianigiani S, Vander Sloten J, Pascale W, Labey L, Innocenti B (2015) A new graphical method to display data sets representing biomechanical knee behaviour. J Exp Orthop 2(1):18PubMedPubMedCentral Pianigiani S, Vander Sloten J, Pascale W, Labey L, Innocenti B (2015) A new graphical method to display data sets representing biomechanical knee behaviour. J Exp Orthop 2(1):18PubMedPubMedCentral
43.
Zurück zum Zitat Ranawat CS, Komistek RD, Rodriguez JA, Dennis DA, Anderle M (2004) In vivo kinematics for fixed and mobile-bearing posterior stabilized knee prostheses. Clin Orthop Relat Res 418:184–190 Ranawat CS, Komistek RD, Rodriguez JA, Dennis DA, Anderle M (2004) In vivo kinematics for fixed and mobile-bearing posterior stabilized knee prostheses. Clin Orthop Relat Res 418:184–190
44.
Zurück zum Zitat Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA (2011) The effect of alignment and BMI on failure of total knee replacement. J Bone Jt Surg Am 93(17):1588–1596 Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA (2011) The effect of alignment and BMI on failure of total knee replacement. J Bone Jt Surg Am 93(17):1588–1596
45.
Zurück zum Zitat Rodriguez JA, Bhende H, Ranawat CS (2001) Total condylar knee replacement: a 20-year followup study. Clin Orthop Relat Res 388:10–17 Rodriguez JA, Bhende H, Ranawat CS (2001) Total condylar knee replacement: a 20-year followup study. Clin Orthop Relat Res 388:10–17
46.
Zurück zum Zitat Sarathi Kopparti P, Lewis G (2007) Influence of three variables on the stresses in a three-dimensional model of a proximal tibia-total knee implant construct. Biomed Mater Eng 17(1):19–28PubMed Sarathi Kopparti P, Lewis G (2007) Influence of three variables on the stresses in a three-dimensional model of a proximal tibia-total knee implant construct. Biomed Mater Eng 17(1):19–28PubMed
47.
Zurück zum Zitat Schultz RA, Miller DC, Kerr CS, Micheli L (1984) Mechanoreceptors in human cruciate ligaments. A histological study. J Bone Jt Surg Am 66(7):1072–1076 Schultz RA, Miller DC, Kerr CS, Micheli L (1984) Mechanoreceptors in human cruciate ligaments. A histological study. J Bone Jt Surg Am 66(7):1072–1076
48.
Zurück zum Zitat Sobieraj MC, Rimnac CM (2009) Ultra high molecular weight polyethylene: mechanics, morphology, and clinical behavior. J Mech Behav Biomed Mater 2(5):433–443PubMed Sobieraj MC, Rimnac CM (2009) Ultra high molecular weight polyethylene: mechanics, morphology, and clinical behavior. J Mech Behav Biomed Mater 2(5):433–443PubMed
49.
Zurück zum Zitat Soenen M, Baracchi M, De Corte R, Labey L, Innocenti B (2013) Stemmed TKA in a femur with a total hip arthroplasty: is there a safe distance between the stem tips? J Arthroplast 28(8):1437–1445 Soenen M, Baracchi M, De Corte R, Labey L, Innocenti B (2013) Stemmed TKA in a femur with a total hip arthroplasty: is there a safe distance between the stem tips? J Arthroplast 28(8):1437–1445
50.
Zurück zum Zitat Stern SH, Insall JN (1992) Posterior stabilized prosthesis. Results after follow-up of nine to twelve years. J Bone Jt Surg Am 74(7):980–986 Stern SH, Insall JN (1992) Posterior stabilized prosthesis. Results after follow-up of nine to twelve years. J Bone Jt Surg Am 74(7):980–986
51.
Zurück zum Zitat Stronach BM, Adams JC, Jones LC, Farrell SM, Hydrick JM (2019) The effect of sacrificing the posterior cruciate ligament in total knee arthroplasties that use a highly congruent polyethylene component. J Arthroplast 34(2):286–289 Stronach BM, Adams JC, Jones LC, Farrell SM, Hydrick JM (2019) The effect of sacrificing the posterior cruciate ligament in total knee arthroplasties that use a highly congruent polyethylene component. J Arthroplast 34(2):286–289
52.
Zurück zum Zitat Vaninbroukx M, Labey L, Innocenti B, Bellemans J (2009) Cementing the femoral component in total arthroplasty: which technique is the best? Knee 16(4):265–268PubMed Vaninbroukx M, Labey L, Innocenti B, Bellemans J (2009) Cementing the femoral component in total arthroplasty: which technique is the best? Knee 16(4):265–268PubMed
53.
Zurück zum Zitat Vanlommel J, Luyckx JP, Labey L, Innocenti B, De Corte R, Bellemans J (2011) Cementing the tibial component in total knee arthroplasty: which technique is the best? J Arthroplast 26(3):492–496 Vanlommel J, Luyckx JP, Labey L, Innocenti B, De Corte R, Bellemans J (2011) Cementing the tibial component in total knee arthroplasty: which technique is the best? J Arthroplast 26(3):492–496
54.
Zurück zum Zitat Victor J, Banks S, Bellemans J (2005) Kinematics of posterior cruciate ligament-retaining and -substituting total knee arthroplasty: a prospective randomised outcome study. J Bone Jt Surg Br 87-B:646–655 Victor J, Banks S, Bellemans J (2005) Kinematics of posterior cruciate ligament-retaining and -substituting total knee arthroplasty: a prospective randomised outcome study. J Bone Jt Surg Br 87-B:646–655
55.
Zurück zum Zitat Victor J, Labey L, Wong P, Innocenti B, Bellemans J (2010) The Influence of muscle load on tibio-femoral knee kinematics. J Orthop Res 28(4):419–428PubMed Victor J, Labey L, Wong P, Innocenti B, Bellemans J (2010) The Influence of muscle load on tibio-femoral knee kinematics. J Orthop Res 28(4):419–428PubMed
56.
Zurück zum Zitat Victor J, Van Doninck D, Labey L, Innocenti B, Parizel PM, Bellemans J (2009) How precise can bony landmarks be determined on a CT scan of the knee? Knee 16(5):358–365PubMed Victor J, Van Doninck D, Labey L, Innocenti B, Parizel PM, Bellemans J (2009) How precise can bony landmarks be determined on a CT scan of the knee? Knee 16(5):358–365PubMed
57.
Zurück zum Zitat Victor J, Van Glabbeek F, Vander Sloten J, Parizel PM, Somville J, Bellemans J (2009) An experimental model for kinematic analysis of the knee. J Bone Jt Surg Am 91(Suppl 6):150–163 Victor J, Van Glabbeek F, Vander Sloten J, Parizel PM, Somville J, Bellemans J (2009) An experimental model for kinematic analysis of the knee. J Bone Jt Surg Am 91(Suppl 6):150–163
58.
Zurück zum Zitat Waanders D, Janssen D, Mann K, Verdonschot N (2010) The mechanical effects of different levels of cement penetration at the cement–bone interface. J Biomech 43(6):1167–1175PubMedPubMedCentral Waanders D, Janssen D, Mann K, Verdonschot N (2010) The mechanical effects of different levels of cement penetration at the cement–bone interface. J Biomech 43(6):1167–1175PubMedPubMedCentral
59.
Zurück zum Zitat Walker PS, Sussman-Fort JM, Yildirim G, Boyer J (2009) Design features of total knees for achieving normal knee motion characteristics. J Arthroplast 24(3):475–483 Walker PS, Sussman-Fort JM, Yildirim G, Boyer J (2009) Design features of total knees for achieving normal knee motion characteristics. J Arthroplast 24(3):475–483
60.
Zurück zum Zitat Wang H, Simpson KJ, Ferrara MS, Chamnongkich S, Kinsey T, Mahoney OM (2006) Biomechanical differences exhibited during sit-to-stand between total knee arthroplasty designs of varying radii. J Arthroplast 21(8):1193–1199 Wang H, Simpson KJ, Ferrara MS, Chamnongkich S, Kinsey T, Mahoney OM (2006) Biomechanical differences exhibited during sit-to-stand between total knee arthroplasty designs of varying radii. J Arthroplast 21(8):1193–1199
Metadaten
Titel
High congruency MB insert design: stabilizing knee joint even with PCL deficiency
verfasst von
Bernardo Innocenti
Publikationsdatum
06.11.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 9/2020
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-019-05764-0

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie erweitert durch Fallbeispiele, Videos und Abbildungen. Zur Fortbildung und Wissenserweiterung, verfasst und geprüft von Expertinnen und Experten der Gesellschaft für Arthroskopie und Gelenkchirurgie (AGA).


Jetzt entdecken!

Neu im Fachgebiet Orthopädie und Unfallchirurgie

Nackenschmerzen nach Bandscheibenvorfall: Muskeltraining hilft!

Bei hartnäckigen Schmerzen aufgrund einer zervikalen Radikulopathie schlägt ein Team der Universität Istanbul vor, lokale Steroidinjektionen mit einem speziellen Trainingsprogramm zur Stabilisierung der Nackenmuskulatur zu kombinieren.

Die elektronische Patientenakte kommt: Das sollten Sie jetzt wissen

Am 15. Januar geht die „ePA für alle“ zunächst in den Modellregionen an den Start. Doch schon bald soll sie in allen Praxen zum Einsatz kommen. Was ist jetzt zu tun? Was müssen Sie wissen? Wir geben in einem FAQ Antworten auf 21 Fragen.

Was sich Menschen mit Frozen Shoulder wünschen

Die Capsulitis adhaesiva des Glenohumeralgelenks, auch als Frozen Shoulder bezeichnet, belastet die Betroffenen weit über die körperlichen Beschwerden hinaus, wie eine italienische Studie ergeben hat.

Restriktive Sauerstoffgabe ohne Vorteil bei schwerem Trauma

Ob schwer verletzte Personen besser restriktiv oder liberal mit Sauerstoff versorgt werden sollten, hat die Arbeitsgruppe der TRAUMOX2-Studie untersucht – mit klarem Ergebnis.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.