Skip to main content
Erschienen in: European Radiology 6/2019

14.12.2018 | Musculoskeletal

High-resolution flat panel CT versus 3-T MR arthrography of the wrist: initial results in vivo

verfasst von: L. Sonnow, S. Koennecker, R. Luketina, T. Werncke, J. B. Hinrichs, B. C. Meyer, F. K. Wacker, C. von Falck

Erschienen in: European Radiology | Ausgabe 6/2019

Einloggen, um Zugang zu erhalten

Abstract

Objectives

The objective of this study was to compare the diagnostic performance of direct C-arm flat panel computed tomography arthrography (FPCT-A) with direct magnetic resonance arthrography (MR-A) of the wrist in patients with clinically suspected pathologies.

Methods

Forty-nine patients underwent tri-compartmental wrist arthrography. FPCT-A was acquired using a high-resolution acquisition mode, followed by a 3-T MR exam using a dedicated wrist coil. Image quality and artifacts of FPCT-A and MR-A were evaluated with regard to the depictability of anatomical structures. The time stamps for the different image acquisitions were recorded for workflow assessment.

Results

Image quality was rated significantly superior for all structures for FPCT-A (p < 0.001) as compared to MR-A including intrinsic ligaments, TFCC, cartilage, subchondral bone, and trabeculae. The differences in image quality were highest for cartilage (2.0) and lowest for TFCC (0.9). The artifacts were rated lower in MR-A than in FPCT-A (p < 0.001). The procedure was more time-efficient in FPCT-A than in MR-A.

Conclusions

FPCT-A of the wrist provides superior image quality and optimized workflow as compared to MR-A. Therefore, FPCT-A should be considered in patients scheduled for dedicated imaging of the intrinsic structures of the wrist.

Key Points

• FPCT arthrography allows high-resolution imaging of the intrinsic wrist structures.
• The image quality is superior as compared to MR arthrography.
• The procedure is more time-efficient than MR arthrography.
Literatur
1.
Zurück zum Zitat Kümmel A, Ebner L, Kraus M et al (2014) Magnet resonance imaging in common injuries of the wrist. Unfallchirurg 117:221–226CrossRefPubMed Kümmel A, Ebner L, Kraus M et al (2014) Magnet resonance imaging in common injuries of the wrist. Unfallchirurg 117:221–226CrossRefPubMed
2.
Zurück zum Zitat Rohman EM, Agel J, Putnam MD, Adams JE (2014) Scapholunate interosseous ligament injuries: a retrospective review of treatment and outcomes in 82 wrists. J Hand Surg Am 39:2020–2026CrossRefPubMed Rohman EM, Agel J, Putnam MD, Adams JE (2014) Scapholunate interosseous ligament injuries: a retrospective review of treatment and outcomes in 82 wrists. J Hand Surg Am 39:2020–2026CrossRefPubMed
3.
Zurück zum Zitat Magee T (2009) Comparison of 3-T MRI and arthroscopy of intrinsic wrist ligament and TFCC tears. AJR Am J Roentgenol 192:80–85CrossRef Magee T (2009) Comparison of 3-T MRI and arthroscopy of intrinsic wrist ligament and TFCC tears. AJR Am J Roentgenol 192:80–85CrossRef
4.
Zurück zum Zitat Smith TO, Drew B, Toms AP, Jerosch-Herold C, Chojnowski AJ (2012) Diagnostic accuracy of magnetic resonance imaging and magnetic resonance arthrography for triangular fibrocartilaginous complex injury: a systematic review and meta-analysis. J Bone Joint Surg Am 94:824–832 Smith TO, Drew B, Toms AP, Jerosch-Herold C, Chojnowski AJ (2012) Diagnostic accuracy of magnetic resonance imaging and magnetic resonance arthrography for triangular fibrocartilaginous complex injury: a systematic review and meta-analysis. J Bone Joint Surg Am 94:824–832
5.
Zurück zum Zitat Štouračová A, Šprláková-Puková A, Čižmář I, Procházková J, Janoušová E, Vališ P (2016) High-resolution MR examination of the scapholunate ligament using a microscopic coil: comparison with direct MR arthrography and arthroscopy findings. Acta Chir Orthop Traumatol Cech 83:327–331 Štouračová A, Šprláková-Puková A, Čižmář I, Procházková J, Janoušová E, Vališ P (2016) High-resolution MR examination of the scapholunate ligament using a microscopic coil: comparison with direct MR arthrography and arthroscopy findings. Acta Chir Orthop Traumatol Cech 83:327–331
6.
Zurück zum Zitat Moser T, Dosch JC, Moussaoui A, Dietemann JL (2007) Wrist ligament tears: evaluation of MRI and combined MDCT and MR arthrography. AJR Am J Roentgenol 188:1278–1286CrossRefPubMed Moser T, Dosch JC, Moussaoui A, Dietemann JL (2007) Wrist ligament tears: evaluation of MRI and combined MDCT and MR arthrography. AJR Am J Roentgenol 188:1278–1286CrossRefPubMed
7.
Zurück zum Zitat Schmid MR, Schertler T, Pfirrmann CW et al (2005) Interosseous ligament tears of the wrist: comparison of multi-detector row CT arthrography and MR imaging. Radiology 237:1008–1013CrossRefPubMed Schmid MR, Schertler T, Pfirrmann CW et al (2005) Interosseous ligament tears of the wrist: comparison of multi-detector row CT arthrography and MR imaging. Radiology 237:1008–1013CrossRefPubMed
8.
Zurück zum Zitat Fischer W, Bohndorf K, Kreitner KF, Schmitt R, Wörtler K, Zentner J (2009) Indications for CT and MR arthrography--recommendations of the musculoskeletal workgroup of the DRG. Rofo 181:441–446 Fischer W, Bohndorf K, Kreitner KF, Schmitt R, Wörtler K, Zentner J (2009) Indications for CT and MR arthrography--recommendations of the musculoskeletal workgroup of the DRG. Rofo 181:441–446
9.
Zurück zum Zitat Guggenberger R, Fischer MA, Hodler J, Pfammatter T, Andreisek G (2012) Flat-panel CT arthrography: feasibility study and comparison to multidetector CT arthrography. Invest Radiol 47:312–318 Guggenberger R, Fischer MA, Hodler J, Pfammatter T, Andreisek G (2012) Flat-panel CT arthrography: feasibility study and comparison to multidetector CT arthrography. Invest Radiol 47:312–318
10.
Zurück zum Zitat Kyriakou Y, Struffert T, Dörfler A, Kalender WA (2009) Basic principles of flat detector computed tomography (FD-CT). Radiologe 49:811–819CrossRefPubMed Kyriakou Y, Struffert T, Dörfler A, Kalender WA (2009) Basic principles of flat detector computed tomography (FD-CT). Radiologe 49:811–819CrossRefPubMed
11.
Zurück zum Zitat Guggenberger R, Morsbach F, Alkadhi H et al (2013) C-arm flat-panel CT arthrography of the wrist and elbow: first experiences in human cadavers. Skeletal Radiol 42:419–429CrossRefPubMed Guggenberger R, Morsbach F, Alkadhi H et al (2013) C-arm flat-panel CT arthrography of the wrist and elbow: first experiences in human cadavers. Skeletal Radiol 42:419–429CrossRefPubMed
13.
Zurück zum Zitat McHugh ML (2012) Interrater reliability: the kappa statistic. Biochem Med (Zagreb) 22:276–282CrossRef McHugh ML (2012) Interrater reliability: the kappa statistic. Biochem Med (Zagreb) 22:276–282CrossRef
14.
Zurück zum Zitat Robinson G, Chung T, Finlay K, Friedman L (2006) Axial oblique MR imaging of the intrinsic ligaments of the wrist: initial experience. Skeletal Radiol 35:765–773CrossRefPubMed Robinson G, Chung T, Finlay K, Friedman L (2006) Axial oblique MR imaging of the intrinsic ligaments of the wrist: initial experience. Skeletal Radiol 35:765–773CrossRefPubMed
15.
Zurück zum Zitat Lee RK, Ng AW, Tong CS et al (2013) Intrinsic ligament and triangular fibrocartilage complex tears of the wrist: comparison of MDCT arthrography, conventional 3-T MRI, and MR arthrography. Skeletal Radiol 42:1277–1285CrossRefPubMed Lee RK, Ng AW, Tong CS et al (2013) Intrinsic ligament and triangular fibrocartilage complex tears of the wrist: comparison of MDCT arthrography, conventional 3-T MRI, and MR arthrography. Skeletal Radiol 42:1277–1285CrossRefPubMed
16.
Zurück zum Zitat Daenen BR, Ferrara MA, Marcelis S, Dondelinger RF (1998) Evaluation of patellar cartilage surface lesions: comparison of CT arthrography and fat-suppressed FLASH 3D MR imaging. Eur Radiol 8:981–985CrossRefPubMed Daenen BR, Ferrara MA, Marcelis S, Dondelinger RF (1998) Evaluation of patellar cartilage surface lesions: comparison of CT arthrography and fat-suppressed FLASH 3D MR imaging. Eur Radiol 8:981–985CrossRefPubMed
17.
Zurück zum Zitat El-Khoury GY, Alliman KJ, Lundberg HJ, Rudert MJ, Brown TD, Saltzman CL (2004) Cartilage thickness in cadaveric ankles: measurement with double-contrast multi-detector row CT arthrography versus MR imaging. Radiology 233:768–773 El-Khoury GY, Alliman KJ, Lundberg HJ, Rudert MJ, Brown TD, Saltzman CL (2004) Cartilage thickness in cadaveric ankles: measurement with double-contrast multi-detector row CT arthrography versus MR imaging. Radiology 233:768–773
18.
Zurück zum Zitat Sahin M, Calisir C, Omeroglu H, Inan U, Mutlu F, Kaya T (2014) Evaluation of labral pathology and hip articular cartilage in patients with femoroacetabular impingement (FAI): comparison of multidetector CT arthrography and MR arthrography. Pol J Radiol 79:374–380 Sahin M, Calisir C, Omeroglu H, Inan U, Mutlu F, Kaya T (2014) Evaluation of labral pathology and hip articular cartilage in patients with femoroacetabular impingement (FAI): comparison of multidetector CT arthrography and MR arthrography. Pol J Radiol 79:374–380
19.
Zurück zum Zitat Acid S, Le Corroller T, Aswad R, Pauly V, Champsaur P (2012) Preoperative imaging of anterior shoulder instability: diagnostic effectiveness of MDCT arthrography and comparison with MR arthrography and arthroscopy. AJR Am J Roentgenol 198:661–667 Acid S, Le Corroller T, Aswad R, Pauly V, Champsaur P (2012) Preoperative imaging of anterior shoulder instability: diagnostic effectiveness of MDCT arthrography and comparison with MR arthrography and arthroscopy. AJR Am J Roentgenol 198:661–667
21.
Zurück zum Zitat Guggenberger R, Winklhofer S, Spiczak JV, Andreisek G, Alkadhi H (2013) In vitro high-resolution flat-panel computed tomographic arthrography for artificial cartilage defect detection: comparison with multidetector computed tomography. Invest Radiol 48:614–621 Guggenberger R, Winklhofer S, Spiczak JV, Andreisek G, Alkadhi H (2013) In vitro high-resolution flat-panel computed tomographic arthrography for artificial cartilage defect detection: comparison with multidetector computed tomography. Invest Radiol 48:614–621
22.
Zurück zum Zitat Werncke T, Sonnow L, Meyer BC et al (2017) Ultra-high resolution C-arm CT arthrography of the wrist: radiation dose and image quality compared to conventional multidetector computed tomography. Eur J Radiol 89:191–199CrossRefPubMed Werncke T, Sonnow L, Meyer BC et al (2017) Ultra-high resolution C-arm CT arthrography of the wrist: radiation dose and image quality compared to conventional multidetector computed tomography. Eur J Radiol 89:191–199CrossRefPubMed
23.
Zurück zum Zitat Chemouni D, Champsaur P, Guenoun D, Desrousseaux J, Pauly V, Le Corroller T (2014) Diagnostic performance of flat-panel CT arthrography for cartilage defect detection in the ankle joint: comparison with MDCT arthrography with gross anatomy as the reference standard. AJR Am J Roentgenol 203:1069–1074 Chemouni D, Champsaur P, Guenoun D, Desrousseaux J, Pauly V, Le Corroller T (2014) Diagnostic performance of flat-panel CT arthrography for cartilage defect detection in the ankle joint: comparison with MDCT arthrography with gross anatomy as the reference standard. AJR Am J Roentgenol 203:1069–1074
Metadaten
Titel
High-resolution flat panel CT versus 3-T MR arthrography of the wrist: initial results in vivo
verfasst von
L. Sonnow
S. Koennecker
R. Luketina
T. Werncke
J. B. Hinrichs
B. C. Meyer
F. K. Wacker
C. von Falck
Publikationsdatum
14.12.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 6/2019
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-018-5901-5

Weitere Artikel der Ausgabe 6/2019

European Radiology 6/2019 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.