Skip to main content
Erschienen in: Critical Care 3/2009

01.06.2009 | Commentary

Hippocrates is alive and weaning in Brazil

verfasst von: Nalan Adigüzel, Gökay Güngör, Martin J Tobin

Erschienen in: Critical Care | Ausgabe 3/2009

Einloggen, um Zugang zu erhalten

Abstract

In a group of postoperative patients, Taniguchi and coworkers compared the effect of a computerized system for weaning against 'manual care'. The computerized system involved automatic adjustments to the level of pressure support to achieve a target respiratory rate. Manual care involved adjustments to the level of pressure support to keep the ratio of respiratory frequency to tidal volume below 80. The duration of ventilator weaning was equivalent with the two approaches. The level of pressure support, however, was lower with manual care than with computerized ventilation. The study adds support to the notion that ventilator duration is shortened when weaning is contemplated at the earliest possible time. The findings also emphasize the importance of the Hippocratic dictum that patient outcome is improved when care is individualized rather than delivered according to a protocol.
Literatur
1.
Zurück zum Zitat Taniguchi C, Eid RC, Saghabi C, Souza R, Silva E, Knobel E, Paes T, Barbas CS: Automatic versus manual pressure support reduction in the weaning of post-operative patients: a randomized controlled trial. Crit Care 2009, 13: R6. 10.1186/cc7695PubMedCentralCrossRefPubMed Taniguchi C, Eid RC, Saghabi C, Souza R, Silva E, Knobel E, Paes T, Barbas CS: Automatic versus manual pressure support reduction in the weaning of post-operative patients: a randomized controlled trial. Crit Care 2009, 13: R6. 10.1186/cc7695PubMedCentralCrossRefPubMed
2.
Zurück zum Zitat Tobin MJ: Remembrance of weaning past: the seminal papers. Intensive Care Med 2006, 32: 1485-1493. 10.1007/s00134-006-0338-8CrossRefPubMed Tobin MJ: Remembrance of weaning past: the seminal papers. Intensive Care Med 2006, 32: 1485-1493. 10.1007/s00134-006-0338-8CrossRefPubMed
3.
Zurück zum Zitat Tobin MJ, Jubran A: Weaning from mechanical ventilation. In Principles and Practice of Mechanical Ventilation. 2nd edition. Edited by: Tobin MJ. New York, NY: McGraw-Hill, Inc; 2006:1185-1220. Tobin MJ, Jubran A: Weaning from mechanical ventilation. In Principles and Practice of Mechanical Ventilation. 2nd edition. Edited by: Tobin MJ. New York, NY: McGraw-Hill, Inc; 2006:1185-1220.
4.
Zurück zum Zitat Lellouche F, Mancebo J, Jolliet P, Roeseler J, Schortgen F, Dojat M, Cabello B, Bouadma L, Rodriguez P, Maggiore S, Reynaert M, Mersmann S, Brochard L: A multicenter randomized trial of computer-driven protocolized weaning from mechanical ventilation. Am J Respir Crit Care Med 2006, 174: 894-900. 10.1164/rccm.200511-1780OCCrossRefPubMed Lellouche F, Mancebo J, Jolliet P, Roeseler J, Schortgen F, Dojat M, Cabello B, Bouadma L, Rodriguez P, Maggiore S, Reynaert M, Mersmann S, Brochard L: A multicenter randomized trial of computer-driven protocolized weaning from mechanical ventilation. Am J Respir Crit Care Med 2006, 174: 894-900. 10.1164/rccm.200511-1780OCCrossRefPubMed
5.
Zurück zum Zitat Rose L, Presneill JJ, Johnston L, Cade JF: A randomised, controlled trial of conventional versus automated weaning from mechanical ventilation using SmartCare/PS. Intensive Care Med 2008, 34: 1788-1795. 10.1007/s00134-008-1179-4CrossRefPubMed Rose L, Presneill JJ, Johnston L, Cade JF: A randomised, controlled trial of conventional versus automated weaning from mechanical ventilation using SmartCare/PS. Intensive Care Med 2008, 34: 1788-1795. 10.1007/s00134-008-1179-4CrossRefPubMed
6.
Zurück zum Zitat Yang K, Tobin MJ: A prospective study of indexes predicting the outcome of trials of weaning from mechanical ventilation. N Engl J Med 1991, 324: 1445-1450.CrossRefPubMed Yang K, Tobin MJ: A prospective study of indexes predicting the outcome of trials of weaning from mechanical ventilation. N Engl J Med 1991, 324: 1445-1450.CrossRefPubMed
7.
Zurück zum Zitat Tobin MJ, Jubran A: Variable performance of weaning-predictor tests: role of Bayes' theorem and spectrum and test-referral bias. Intensive Care Med 2006, 32: 2002-2012. 10.1007/s00134-006-0439-4CrossRefPubMed Tobin MJ, Jubran A: Variable performance of weaning-predictor tests: role of Bayes' theorem and spectrum and test-referral bias. Intensive Care Med 2006, 32: 2002-2012. 10.1007/s00134-006-0439-4CrossRefPubMed
8.
Zurück zum Zitat Nuland SB: The totem of medicine: Hippocrates. In Doctors: the biography of medicine. New York: Alfred A Knopf; 1988:3-30. Nuland SB: The totem of medicine: Hippocrates. In Doctors: the biography of medicine. New York: Alfred A Knopf; 1988:3-30.
9.
Zurück zum Zitat Ely EW, Meade MO, Haponik EF, Kollef MH, Cook DJ, Guyatt GH, Stoller JK: Mechanical ventilator weaning protocols driven by nonphysician health-care professionals: evidence-based clinical practice guidelines. Chest 2001, 120: 454S-463S. 10.1378/chest.120.6_suppl.454SCrossRefPubMed Ely EW, Meade MO, Haponik EF, Kollef MH, Cook DJ, Guyatt GH, Stoller JK: Mechanical ventilator weaning protocols driven by nonphysician health-care professionals: evidence-based clinical practice guidelines. Chest 2001, 120: 454S-463S. 10.1378/chest.120.6_suppl.454SCrossRefPubMed
Metadaten
Titel
Hippocrates is alive and weaning in Brazil
verfasst von
Nalan Adigüzel
Gökay Güngör
Martin J Tobin
Publikationsdatum
01.06.2009
Verlag
BioMed Central
Erschienen in
Critical Care / Ausgabe 3/2009
Elektronische ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc7746

Weitere Artikel der Ausgabe 3/2009

Critical Care 3/2009 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.