Skip to main content
Erschienen in: Rheumatology International 6/2016

19.03.2016 | Imaging

How does a cadaver model work for testing ultrasound diagnostic capability for rheumatic-like tendon damage?

verfasst von: Iustina Janta, Julio Morán, Esperanza Naredo, Juan Carlos Nieto, Jacqueline Uson, Ingrid Möller, David Bong, George A. W. Bruyn, Maria Antonietta D´Agostino, Emilio Filippucci, Hilde Berner Hammer, Annamaria Iagnocco, Lene Terslev, Jorge Murillo González, José Ramón Mérida, Luis Carreño

Erschienen in: Rheumatology International | Ausgabe 6/2016

Einloggen, um Zugang zu erhalten

Abstract

To establish whether a cadaver model can serve as an effective surrogate for the detection of tendon damage characteristic of rheumatoid arthritis (RA). In addition, we evaluated intraobserver and interobserver agreement in the grading of RA-like tendon tears shown by US, as well as the concordance between the US findings and the surgically induced lesions in the cadaver model. RA-like tendon damage was surgically induced in the tibialis anterior tendon (TAT) and tibialis posterior tendon (TPT) of ten ankle/foot fresh-frozen cadaveric specimens. Of the 20 tendons examined, six were randomly assigned a surgically induced partial tear; six a complete tear; and eight left undamaged. Three rheumatologists, experts in musculoskeletal US, assessed from 1 to 5 the quality of US imaging of the cadaveric models on a Likert scale. Tendons were then categorized as having either no damage, (0); partial tear, (1); or complete tear (2). All 20 tendons were blindly and independently evaluated twice, over two rounds, by each of the three observers. Overall, technical performance was satisfactory for all items in the two rounds (all values over 2.9 in a Likert scale 1–5). Intraobserver and interobserver agreement for US grading of tendon damage was good (mean κ values 0.62 and 0.71, respectively), with greater reliability found in the TAT than the TPT. Concordance between US findings and experimental tendon lesions was acceptable (70–100 %), again greater for the TAT than for the TPT. A cadaver model with surgically created tendon damage can be useful in evaluating US metric properties of RA tendon lesions
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Pap T, Distler O (2005) Linking angiogenesis to bone destruction in arthritis. Arthritis Rheum 52:1346–1348CrossRefPubMed Pap T, Distler O (2005) Linking angiogenesis to bone destruction in arthritis. Arthritis Rheum 52:1346–1348CrossRefPubMed
2.
Zurück zum Zitat Boutry N, Larde A, Lapegue F, Solau-Gervais E, Flipo RM, Cotten A (2003) Magnetic resonance imaging appearance of the hands and feet in patients with early rheumatoid arthritis. J Rheumatol 30:671–679PubMed Boutry N, Larde A, Lapegue F, Solau-Gervais E, Flipo RM, Cotten A (2003) Magnetic resonance imaging appearance of the hands and feet in patients with early rheumatoid arthritis. J Rheumatol 30:671–679PubMed
3.
Zurück zum Zitat Eshedı E, Feist CE, Althoff Hamm B, Konen E, Burmester GR, Backhaus M, Hermann KG (2009) Tenosynovitis of the flexor tendons of the hand detected by MRI: an early indicator of rheumatoid arthritis. Rheumatology 48:887–891. doi:10.1093/rheumatology/kep136 CrossRef Eshedı E, Feist CE, Althoff Hamm B, Konen E, Burmester GR, Backhaus M, Hermann KG (2009) Tenosynovitis of the flexor tendons of the hand detected by MRI: an early indicator of rheumatoid arthritis. Rheumatology 48:887–891. doi:10.​1093/​rheumatology/​kep136 CrossRef
4.
Zurück zum Zitat Jain A, Nanchahal J, Troeberg L, Green P, Brennan F (2001) Production of cytokines, vascular endothelial growth factor, matrix metalloproteinases and tissue inhibitor of metalloproteinases by tenosynovium demonstrates its potential for tendon destruction in rheumatoid arthritis. Arthritis Rheum 44:1754–1760CrossRefPubMed Jain A, Nanchahal J, Troeberg L, Green P, Brennan F (2001) Production of cytokines, vascular endothelial growth factor, matrix metalloproteinases and tissue inhibitor of metalloproteinases by tenosynovium demonstrates its potential for tendon destruction in rheumatoid arthritis. Arthritis Rheum 44:1754–1760CrossRefPubMed
5.
Zurück zum Zitat Fornage BD, Rifkin MD (1988) Ultrasound examination of tendons. Radiol Clin N Am 26(1):87–107PubMed Fornage BD, Rifkin MD (1988) Ultrasound examination of tendons. Radiol Clin N Am 26(1):87–107PubMed
6.
Zurück zum Zitat Rockett MS, Waitches G, Sudakoff G, Brage M (1998) Use of ultrasonography versus magnetic resonance imaging for tendon abnormalities around the ankle. Foot Ankle Int 19:604–612CrossRefPubMed Rockett MS, Waitches G, Sudakoff G, Brage M (1998) Use of ultrasonography versus magnetic resonance imaging for tendon abnormalities around the ankle. Foot Ankle Int 19:604–612CrossRefPubMed
7.
Zurück zum Zitat Waitches GM, Rockett M, Brage M, Sudakoff G (1998) Ultrasonographic-surgical correlation of ankle tendon tears. J Ultrasound Med 17:249–256PubMed Waitches GM, Rockett M, Brage M, Sudakoff G (1998) Ultrasonographic-surgical correlation of ankle tendon tears. J Ultrasound Med 17:249–256PubMed
8.
Zurück zum Zitat Swen WA, Jacobs JW, Hubach PC, Klasens JH, Algra PR, Bijlsma JW (2000) Comparison of sonography and magnetic resonance imaging for the diagnosis of partial tears of finger extensor tendons in rheumatoid arthritis. Rheumatology 39:55–62CrossRefPubMed Swen WA, Jacobs JW, Hubach PC, Klasens JH, Algra PR, Bijlsma JW (2000) Comparison of sonography and magnetic resonance imaging for the diagnosis of partial tears of finger extensor tendons in rheumatoid arthritis. Rheumatology 39:55–62CrossRefPubMed
9.
Zurück zum Zitat Kovacs P, Behensky H, Lottersberger C, Bodner G, Brenner E, Moriggl B (2001) Can the dimensions of artificial tendon lesions be predicted ultrasonographically? A cadaveric study. J Ultrasound Med 20:459–464PubMed Kovacs P, Behensky H, Lottersberger C, Bodner G, Brenner E, Moriggl B (2001) Can the dimensions of artificial tendon lesions be predicted ultrasonographically? A cadaveric study. J Ultrasound Med 20:459–464PubMed
10.
Zurück zum Zitat Premkumar A, Perry MB, Dwyer AJ, Gerber LH, Johnson D, Venzon D, Shawker TH (2002) Sonography and MR imaging of posterior tibial tendinopathy. AJR Am J Roentgenol 178:223–232CrossRefPubMed Premkumar A, Perry MB, Dwyer AJ, Gerber LH, Johnson D, Venzon D, Shawker TH (2002) Sonography and MR imaging of posterior tibial tendinopathy. AJR Am J Roentgenol 178:223–232CrossRefPubMed
11.
Zurück zum Zitat Gerling MC, Pfirrmann CW, Farooki S, Kim C, Boyd GJ, Aronoff MD, Feng SA, Jacobson JA, Resnick D, Brage ME (2003) Posterior tibialis tendon tears: comparison of the diagnostic efficacy of magnetic resonance imaging and ultrasonography for the detection of surgically created longitudinal tears in cadavers. Investig Radiol 38:51–56CrossRef Gerling MC, Pfirrmann CW, Farooki S, Kim C, Boyd GJ, Aronoff MD, Feng SA, Jacobson JA, Resnick D, Brage ME (2003) Posterior tibialis tendon tears: comparison of the diagnostic efficacy of magnetic resonance imaging and ultrasonography for the detection of surgically created longitudinal tears in cadavers. Investig Radiol 38:51–56CrossRef
12.
13.
Zurück zum Zitat Martinoli C, Derchi LE, Pastorino C, Bertolotto M, Silvestri E (1993) Analysis of echotexture of tendons with US. Radiology 186:839–843CrossRefPubMed Martinoli C, Derchi LE, Pastorino C, Bertolotto M, Silvestri E (1993) Analysis of echotexture of tendons with US. Radiology 186:839–843CrossRefPubMed
14.
Zurück zum Zitat Coakley FV, Samanta AK, Finlay DB (1994) Ultrasonography of the tibialis posterior tendon in rheumatoid arthritis. Br J Rheumatol 33:273–277CrossRefPubMed Coakley FV, Samanta AK, Finlay DB (1994) Ultrasonography of the tibialis posterior tendon in rheumatoid arthritis. Br J Rheumatol 33:273–277CrossRefPubMed
15.
Zurück zum Zitat Grassi W, Filippucci E, Farina A, Cervini C (2000) Sonographic imaging of tendons. Arthritis Rheum 43:969–976CrossRefPubMed Grassi W, Filippucci E, Farina A, Cervini C (2000) Sonographic imaging of tendons. Arthritis Rheum 43:969–976CrossRefPubMed
17.
Zurück zum Zitat Alcalde M, D’Agostino MA, Bruyn GAW, Möller I, Iagnocco A, Wakefield RJ, Naredo E (2012) A systematic literature review of ultrasound definitions, scoring systems and validity according to the OMERACT filter for tendon lesion in rheumatoid arthritis and other inflammatory joint disease. Rheumatology 51:1246–1260. doi:10.1093/rheumatology/kes018 CrossRefPubMed Alcalde M, D’Agostino MA, Bruyn GAW, Möller I, Iagnocco A, Wakefield RJ, Naredo E (2012) A systematic literature review of ultrasound definitions, scoring systems and validity according to the OMERACT filter for tendon lesion in rheumatoid arthritis and other inflammatory joint disease. Rheumatology 51:1246–1260. doi:10.​1093/​rheumatology/​kes018 CrossRefPubMed
18.
19.
Zurück zum Zitat Bruyn GA, Möller I, Garrido J, Bong D, D’Agostino MA, Iagnocco A, Karim Z, Terslev L, Swen N, Balint P, Baudoin P, van Reesema DS, Pineda C, Wakefield RJ, Naredo E (2012) Reliability testing of tendon disease using two different scanning methods in patients with rheumatoid arthritis. First step towards an ultrasonography scoring index. Rheumatology 51:1655–1661. doi:10.1093/rheumatology/kes103 CrossRefPubMed Bruyn GA, Möller I, Garrido J, Bong D, D’Agostino MA, Iagnocco A, Karim Z, Terslev L, Swen N, Balint P, Baudoin P, van Reesema DS, Pineda C, Wakefield RJ, Naredo E (2012) Reliability testing of tendon disease using two different scanning methods in patients with rheumatoid arthritis. First step towards an ultrasonography scoring index. Rheumatology 51:1655–1661. doi:10.​1093/​rheumatology/​kes103 CrossRefPubMed
20.
Zurück zum Zitat Bruyn GA, Hanova P, Iagnocco A, d’Agostino MA, Moller I, Terslev L, Backhaus M, Balint PV, Filippucci E, Baudoin P, van Vugt R, Pineda C, Wakefield R, Garrido J, Pecha O, Naredo E, OMERACT Ultrasound Task Force (2014) Ultrasound definition of tendon damage in patients with rheumatoid arthritis. Results of a OMERACT consensus-based ultrasound score focussing on the diagnostic reliability. Ann Rheum Dis 73:1929–1934. doi:10.1136/annrheumdis-2013-203596 CrossRefPubMed Bruyn GA, Hanova P, Iagnocco A, d’Agostino MA, Moller I, Terslev L, Backhaus M, Balint PV, Filippucci E, Baudoin P, van Vugt R, Pineda C, Wakefield R, Garrido J, Pecha O, Naredo E, OMERACT Ultrasound Task Force (2014) Ultrasound definition of tendon damage in patients with rheumatoid arthritis. Results of a OMERACT consensus-based ultrasound score focussing on the diagnostic reliability. Ann Rheum Dis 73:1929–1934. doi:10.​1136/​annrheumdis-2013-203596 CrossRefPubMed
21.
Zurück zum Zitat Backhaus M, Burmester GR, Gerber T, Grassi W, Machold KP, Swen WA, Wakefield RJ, Manger B, Working Group for Musculoskeletal Ultrasound in the EULAR Standing Committee on International Clinical Studies including Therapeutic Trials (2001) Guidelines for musculoskeletal ultrasound in rheumatology. Ann Rheum Dis 60:641–649CrossRefPubMedPubMedCentral Backhaus M, Burmester GR, Gerber T, Grassi W, Machold KP, Swen WA, Wakefield RJ, Manger B, Working Group for Musculoskeletal Ultrasound in the EULAR Standing Committee on International Clinical Studies including Therapeutic Trials (2001) Guidelines for musculoskeletal ultrasound in rheumatology. Ann Rheum Dis 60:641–649CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Naredo E, Rodriguez M, Campos C, Rodríguez-Heredia JM, Medina JA, Giner E, Martínez O, Toyos FJ, Ruíz T, Ros I, Pujol M, Miquel X, García L, Aznar JJ, Chamizo E, Páez M, Morales P, Rueda A, Tuneu R, Corominas H, de Agustín JJ, Moragues C, Mínguez D, Willisch A, González-Cruz I, Aragón A, Iglesias G, Armas C, Pablo Valdazo J, Vargas C, Calvo-Alén J, Juan-Mas A, Salvador G, Puigdollers A, Galíndez E, Garrido N, Salaberri J, Raya E, Salles M, Díaz C, Cuadra JL, Garrido J, Ultrasound Group of The Spanish Society of Rheumatology (2008) Validity, reproducibility, and responsiveness of a twelve-joint simplified power doppler ultrasonographic assessment of joint inflammation in rheumatoid arthritis. Arthritis Rheum 59:515–522. doi:10.1002/art.23529 CrossRefPubMed Naredo E, Rodriguez M, Campos C, Rodríguez-Heredia JM, Medina JA, Giner E, Martínez O, Toyos FJ, Ruíz T, Ros I, Pujol M, Miquel X, García L, Aznar JJ, Chamizo E, Páez M, Morales P, Rueda A, Tuneu R, Corominas H, de Agustín JJ, Moragues C, Mínguez D, Willisch A, González-Cruz I, Aragón A, Iglesias G, Armas C, Pablo Valdazo J, Vargas C, Calvo-Alén J, Juan-Mas A, Salvador G, Puigdollers A, Galíndez E, Garrido N, Salaberri J, Raya E, Salles M, Díaz C, Cuadra JL, Garrido J, Ultrasound Group of The Spanish Society of Rheumatology (2008) Validity, reproducibility, and responsiveness of a twelve-joint simplified power doppler ultrasonographic assessment of joint inflammation in rheumatoid arthritis. Arthritis Rheum 59:515–522. doi:10.​1002/​art.​23529 CrossRefPubMed
23.
Zurück zum Zitat Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed
24.
Zurück zum Zitat Wakefield RJ, D´Agostino MA, Iagnocco A, Filippucci E, Backhaus M, Scheel AK, Joshua F, Naredo E, Schmidt WA, Grassi W, Moller I, Pineda C, Klauser A, Szkudlarek M, Terslev L, Balint P, Bruyn GA, Swen WA, Jousse-Joulin S, Kane D, Koski JM, O’Connor P, Milutinovic S, Conaghan PG (2007) The OMERACT Ultrasound Group: status of current activities and research directions. J Rheumatol 34:848–851PubMed Wakefield RJ, D´Agostino MA, Iagnocco A, Filippucci E, Backhaus M, Scheel AK, Joshua F, Naredo E, Schmidt WA, Grassi W, Moller I, Pineda C, Klauser A, Szkudlarek M, Terslev L, Balint P, Bruyn GA, Swen WA, Jousse-Joulin S, Kane D, Koski JM, O’Connor P, Milutinovic S, Conaghan PG (2007) The OMERACT Ultrasound Group: status of current activities and research directions. J Rheumatol 34:848–851PubMed
25.
Zurück zum Zitat D’Agostino MA, Conaghan PG, Naredo E, Aegerter P, Iagnocco A, Freeston JE, Filippucci E, Moller I, Pineda C, Joshua F, Backhaus M, Keen HI, Kaeley G, Ziswiler HR, Schmidt WA, Balint PV, Bruyn GA, Jousse-Joulin S, Kane D, Moller I, Szkudlarek M, Terslev L, Wakefield RJ (2009) The OMERACT Ultrasound Task Force—advances and priorities. J Rheumatol 36:1829–1832CrossRefPubMed D’Agostino MA, Conaghan PG, Naredo E, Aegerter P, Iagnocco A, Freeston JE, Filippucci E, Moller I, Pineda C, Joshua F, Backhaus M, Keen HI, Kaeley G, Ziswiler HR, Schmidt WA, Balint PV, Bruyn GA, Jousse-Joulin S, Kane D, Moller I, Szkudlarek M, Terslev L, Wakefield RJ (2009) The OMERACT Ultrasound Task Force—advances and priorities. J Rheumatol 36:1829–1832CrossRefPubMed
26.
Zurück zum Zitat Naredo E, Wakefield RJ, Iagnocco A, Terslev L, Filippucci E, Gandjbakhch F, Aegerter P, Aydin S, Backhaus M, Balint PV, Bruyn GA, Collado P, Finzel S, Freeston JE, Gutierrez M, Joshua F, Jousse-Joulin S, Kane D, Keen HI, Moller I, Mandl P, Ohrndorf S, Pineda C, Schmidt WA, Szkudlarek M, Conaghan PG, D’Agostino MA (2011) The OMERACT ultrasound task force. Summary of advances and priorities. J Rheumatol 38:2063–2067. doi:10.3899/jrheum.110425 CrossRefPubMed Naredo E, Wakefield RJ, Iagnocco A, Terslev L, Filippucci E, Gandjbakhch F, Aegerter P, Aydin S, Backhaus M, Balint PV, Bruyn GA, Collado P, Finzel S, Freeston JE, Gutierrez M, Joshua F, Jousse-Joulin S, Kane D, Keen HI, Moller I, Mandl P, Ohrndorf S, Pineda C, Schmidt WA, Szkudlarek M, Conaghan PG, D’Agostino MA (2011) The OMERACT ultrasound task force. Summary of advances and priorities. J Rheumatol 38:2063–2067. doi:10.​3899/​jrheum.​110425 CrossRefPubMed
27.
Zurück zum Zitat Iagnocco A, Naredo E, Wakefield R, Bruyn GAW, Collado P, Jousse-Joulin S, Finzel S, Ohrndorf S, Delle Sedie A, Backhaus M, Berner-Hammer H, Gandjbakhch F, Kaeley G, Loeuille D, Moller I, Terslev L, Aegerter P, Aydin S, Balint PV, Filippucci E, Mandl P, Pineda C, Roth J, Magni-Manzoni S, Tzaribachev N, Schmidt WA, Conaghan PG, D’Agostino MA (2014) Responsiveness in rheumatoid arthritis. A report from the OMERACT 11 Ultrasound Workshop. J Rheumatol 41:379–382. doi:10.3899/jrheum.131084 CrossRefPubMed Iagnocco A, Naredo E, Wakefield R, Bruyn GAW, Collado P, Jousse-Joulin S, Finzel S, Ohrndorf S, Delle Sedie A, Backhaus M, Berner-Hammer H, Gandjbakhch F, Kaeley G, Loeuille D, Moller I, Terslev L, Aegerter P, Aydin S, Balint PV, Filippucci E, Mandl P, Pineda C, Roth J, Magni-Manzoni S, Tzaribachev N, Schmidt WA, Conaghan PG, D’Agostino MA (2014) Responsiveness in rheumatoid arthritis. A report from the OMERACT 11 Ultrasound Workshop. J Rheumatol 41:379–382. doi:10.​3899/​jrheum.​131084 CrossRefPubMed
28.
Zurück zum Zitat Bruyn GA, Naredo E, Iagnocco A, Balint PV, Backhaus M, Gandjbakhch F, Gutierrez M, Filer A, Finzel S, Ikeda K, Kaeley GS, Magni Manzoni S, Ohrndorf S, Pineda C, Richards B, Roth J, Schmidt WA, Terslev L, D’Agostino MA (2015) OMERACT Ultrasound Task Force. The OMERACT Ultrasound Working Group 10 Years On: Update at OMERACT 12. J Rheumatol 42(11):2172–2176 Bruyn GA, Naredo E, Iagnocco A, Balint PV, Backhaus M, Gandjbakhch F, Gutierrez M, Filer A, Finzel S, Ikeda K, Kaeley GS, Magni Manzoni S, Ohrndorf S, Pineda C, Richards B, Roth J, Schmidt WA, Terslev L, D’Agostino MA (2015) OMERACT Ultrasound Task Force. The OMERACT Ultrasound Working Group 10 Years On: Update at OMERACT 12. J Rheumatol 42(11):2172–2176
Metadaten
Titel
How does a cadaver model work for testing ultrasound diagnostic capability for rheumatic-like tendon damage?
verfasst von
Iustina Janta
Julio Morán
Esperanza Naredo
Juan Carlos Nieto
Jacqueline Uson
Ingrid Möller
David Bong
George A. W. Bruyn
Maria Antonietta D´Agostino
Emilio Filippucci
Hilde Berner Hammer
Annamaria Iagnocco
Lene Terslev
Jorge Murillo González
José Ramón Mérida
Luis Carreño
Publikationsdatum
19.03.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Rheumatology International / Ausgabe 6/2016
Print ISSN: 0172-8172
Elektronische ISSN: 1437-160X
DOI
https://doi.org/10.1007/s00296-016-3460-0

Weitere Artikel der Ausgabe 6/2016

Rheumatology International 6/2016 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.