Skip to main content
Erschienen in: Journal of Interventional Cardiac Electrophysiology 1/2017

07.02.2017 | REVIEWS

How to achieve ultrasound-guided femoral venous access: the new standard of care in the electrophysiology laboratory

verfasst von: Benedict M. Wiles, Nicholas Child, Paul R. Roberts

Erschienen in: Journal of Interventional Cardiac Electrophysiology | Ausgabe 1/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Bedside vascular ultrasound machines are increasingly available. They are used to facilitate safer vascular access across a number of different specialties. In the electrophysiology laboratory however, where patients are frequently anticoagulated and require the insertion of multiple venous sheaths, anatomical landmark techniques predominate. Despite the high number of vascular complications associated with electrophysiological procedures and the increasing evidence to support its use in electrophysiology, ultrasound remains underutilised. A new standard of care is required. A comprehensive technical report, providing a detailed explanation of this important technique, will provide other electrophysiology centres with the knowledge and justification for adopting ultrasound guidance as their standard practice.

Method

We review the increasing body of evidence which demonstrates that routine ultrasound usage can substantially improve the safety of femoral venous access in the electrophysiology laboratory. We offer a comprehensive technical report to guide operators through the process of ultrasound-guided venous access, with a specific focus on the electrophysiology laboratory. Additionally, we detail a novel technique which utilises real-time colour Doppler ultrasound to accurately identify needle tip location during venous puncture.

Conclusions

The use of vascular ultrasound to guide femoral venous cannulation is rapid, inexpensive and easily learnt. Ultrasound is readily available and offers the potential to significantly reduce vascular complications in the unique setting of the electrophysiology laboratory. Ultrasound guidance to achieve femoral venous access should be the new standard of care in electrophysiology.
Literatur
1.
Zurück zum Zitat Elliott TS, Faroqui MH, Armstrong RF, Hanson GC. Guidelines for good practice in central venous catheterization. Hospital Infection Society and the Research Unit of the Royal College of Physicians. J Hosp Infect. 1994;28:163–76.CrossRefPubMed Elliott TS, Faroqui MH, Armstrong RF, Hanson GC. Guidelines for good practice in central venous catheterization. Hospital Infection Society and the Research Unit of the Royal College of Physicians. J Hosp Infect. 1994;28:163–76.CrossRefPubMed
2.
Zurück zum Zitat Calvert N, Hind D, McWilliams RG, Thomas SM, Beverley C, Davidson A. The effectiveness and cost-effectiveness of ultrasound locating devices for central venous access: a systematic review and economic evaluation. Health Technol Assess. 2003;7:1–84.CrossRefPubMed Calvert N, Hind D, McWilliams RG, Thomas SM, Beverley C, Davidson A. The effectiveness and cost-effectiveness of ultrasound locating devices for central venous access: a systematic review and economic evaluation. Health Technol Assess. 2003;7:1–84.CrossRefPubMed
3.
Zurück zum Zitat Bazaral M, Harlan S. Ultrasonographic anatomy of the internal jugular vein relevant to percutaneous cannulation. Crit Care Med. 1981;9:307–10.CrossRefPubMed Bazaral M, Harlan S. Ultrasonographic anatomy of the internal jugular vein relevant to percutaneous cannulation. Crit Care Med. 1981;9:307–10.CrossRefPubMed
4.
Zurück zum Zitat Weiner MM, Geldard P, Mittnacht AJ. Ultrasound-guided vascular access: a comprehensive review. J Cardiothorac Vasc Anesth. 2013;27:345–60.CrossRefPubMed Weiner MM, Geldard P, Mittnacht AJ. Ultrasound-guided vascular access: a comprehensive review. J Cardiothorac Vasc Anesth. 2013;27:345–60.CrossRefPubMed
5.
Zurück zum Zitat Brass P, Hellmich M, Kolodziej L, Schick G, Smith AF. Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization (review). Cochrane Database Syst Rev. 2015;1:CD006962.PubMed Brass P, Hellmich M, Kolodziej L, Schick G, Smith AF. Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization (review). Cochrane Database Syst Rev. 2015;1:CD006962.PubMed
6.
Zurück zum Zitat National Institute for Health and Care Excellence. Guidance on the use of ultrasound locating devices for placing central venous catheters. Technology Appraisal Guidance [TA49], October 2002. Available online at http://www.nice.org.uk/guidance/ta49 (29th September 2016) National Institute for Health and Care Excellence. Guidance on the use of ultrasound locating devices for placing central venous catheters. Technology Appraisal Guidance [TA49], October 2002. Available online at http://​www.​nice.​org.​uk/​guidance/​ta49 (29th September 2016)
7.
Zurück zum Zitat Seto AH, Abu-Fadel MS, Sparling JM, et al. Real-time ultrasound guidance facilitates femoral arterial access and reduces vascular complications: FAUST (Femoral Arterial Access With Ultrasound Trial). JACC Cardiovasc Interv. 2010;3:751–8.CrossRefPubMed Seto AH, Abu-Fadel MS, Sparling JM, et al. Real-time ultrasound guidance facilitates femoral arterial access and reduces vascular complications: FAUST (Femoral Arterial Access With Ultrasound Trial). JACC Cardiovasc Interv. 2010;3:751–8.CrossRefPubMed
8.
Zurück zum Zitat Hussain SK, Eddy MM, Moorman L, et al. Major complications and mortality within 30 days of an electrophysiological procedure at an academic medical centre: implications for developing national standards. J Cardiovasc Electrophysiol. 2015;26:527–31.CrossRefPubMed Hussain SK, Eddy MM, Moorman L, et al. Major complications and mortality within 30 days of an electrophysiological procedure at an academic medical centre: implications for developing national standards. J Cardiovasc Electrophysiol. 2015;26:527–31.CrossRefPubMed
9.
Zurück zum Zitat Brass P, Hellmich M, Kolodziej L, Schick G, Smith AF. Ultrasound guidance versus anatomical landmarks for subclavian or femoral vein catheterization (review). Cochrane Database Syst Rev. 2015;1:CD011447.PubMed Brass P, Hellmich M, Kolodziej L, Schick G, Smith AF. Ultrasound guidance versus anatomical landmarks for subclavian or femoral vein catheterization (review). Cochrane Database Syst Rev. 2015;1:CD011447.PubMed
10.
Zurück zum Zitat Merrer J, De Jonghe B, Golliot F, French Catheter Study Group in Intensive Care, et al. Complications of femoral and subclavian venous catheterization in critically ill patients: a randomized controlled trial. JAMA. 2001;286:700–7.CrossRefPubMed Merrer J, De Jonghe B, Golliot F, French Catheter Study Group in Intensive Care, et al. Complications of femoral and subclavian venous catheterization in critically ill patients: a randomized controlled trial. JAMA. 2001;286:700–7.CrossRefPubMed
11.
Zurück zum Zitat Hughes P, Scott C, Bodenham A. Ultrasonography of the femoral vessels in the groin: implications for vascular access. Anaesthesia. 2000;55:1198–202.CrossRefPubMed Hughes P, Scott C, Bodenham A. Ultrasonography of the femoral vessels in the groin: implications for vascular access. Anaesthesia. 2000;55:1198–202.CrossRefPubMed
12.
Zurück zum Zitat Baum PA, Matsumoto AH, Teitelbaum GP, Zuurbier RA, Barth KH. Anatomic relationship between the common femoral artery and vein: CT evaluation and clinical significance. Radiology. 1989;173:775–7.CrossRefPubMed Baum PA, Matsumoto AH, Teitelbaum GP, Zuurbier RA, Barth KH. Anatomic relationship between the common femoral artery and vein: CT evaluation and clinical significance. Radiology. 1989;173:775–7.CrossRefPubMed
13.
Zurück zum Zitat Warkentine FH, Clyde Pierce M, Lorenz D, Kim IK. The anatomic relationship of femoral vein to femoral artery in euvolemic pediatric patients by ultrasonography: implications for pediatric femoral central venous access. Acad Emerg Med. 2008;15:426–30.CrossRefPubMed Warkentine FH, Clyde Pierce M, Lorenz D, Kim IK. The anatomic relationship of femoral vein to femoral artery in euvolemic pediatric patients by ultrasonography: implications for pediatric femoral central venous access. Acad Emerg Med. 2008;15:426–30.CrossRefPubMed
14.
Zurück zum Zitat Bhatia N, Sivaprakasam J, Alford M, Guruswamy V. The relative position of the femoral artery and vein in children under general anaesthesis—an ultrasound-guided observational study. Paediatr Anaesth. 2014;24:1164–8.CrossRefPubMed Bhatia N, Sivaprakasam J, Alford M, Guruswamy V. The relative position of the femoral artery and vein in children under general anaesthesis—an ultrasound-guided observational study. Paediatr Anaesth. 2014;24:1164–8.CrossRefPubMed
15.
Zurück zum Zitat Seyahi N, Kahveci A, Altiparmak MR, Serdengecti K, Erek E. Ultrasound imaging findings of femoral veins in patients with renal failure and its impact on vascular access. Nephrol Dial Transplant. 2005;20:1864–7.CrossRefPubMed Seyahi N, Kahveci A, Altiparmak MR, Serdengecti K, Erek E. Ultrasound imaging findings of femoral veins in patients with renal failure and its impact on vascular access. Nephrol Dial Transplant. 2005;20:1864–7.CrossRefPubMed
16.
Zurück zum Zitat Sobolev M, Shiloh AL, Di Biase L, Slovut DP. Ultrasound-guided cannulation of the femoral vein in electrophysiological procedures: a systematic review and meta-analysis. Europace 2016; published online 20 May 2016 (available on 29th September 2016 at doi:10.1093/europace/euw113) Sobolev M, Shiloh AL, Di Biase L, Slovut DP. Ultrasound-guided cannulation of the femoral vein in electrophysiological procedures: a systematic review and meta-analysis. Europace 2016; published online 20 May 2016 (available on 29th September 2016 at doi:10.​1093/​europace/​euw113)
17.
Zurück zum Zitat Kirchhof P, Bax J, Blomstrom-Lundquist C, et al. Early and comprehensive management of atrial fibrillation: proceedings from the 2nd AFNET/EHRA consensus conference on atrial fibrillation entitled ‘research perspectives in atrial fibrillation’. Europace. 2009;11:860–85.CrossRefPubMed Kirchhof P, Bax J, Blomstrom-Lundquist C, et al. Early and comprehensive management of atrial fibrillation: proceedings from the 2nd AFNET/EHRA consensus conference on atrial fibrillation entitled ‘research perspectives in atrial fibrillation’. Europace. 2009;11:860–85.CrossRefPubMed
18.
Zurück zum Zitat Errahmouni A, Bun SS, Latcu DG, Saoudi N. Ultrasound-guided venous puncture in electrophysiological procedures: a safe method, rapidly learned. Pacing Clin Electrophysiol. 2014;37:1023–8.CrossRefPubMed Errahmouni A, Bun SS, Latcu DG, Saoudi N. Ultrasound-guided venous puncture in electrophysiological procedures: a safe method, rapidly learned. Pacing Clin Electrophysiol. 2014;37:1023–8.CrossRefPubMed
19.
Zurück zum Zitat Hsu HT, Lu IC, Chang YL, et al. Lateral rotation of the lower extremity increases the distance between the femoral nerve and femoral artery: an ultrasonographic study. Kaohsiung J Med Sci. 2007;23:618–23.CrossRefPubMed Hsu HT, Lu IC, Chang YL, et al. Lateral rotation of the lower extremity increases the distance between the femoral nerve and femoral artery: an ultrasonographic study. Kaohsiung J Med Sci. 2007;23:618–23.CrossRefPubMed
21.
Zurück zum Zitat Troianos CA, Hartman GS, Glas KE, Councils on Intraoperative Echocardiography and Vascular Ultrasound of the American Society of Echocardiography, et al. Guidelines for performing ultrasound guided vascular cannulation: recommendations of the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists. J Am Soc Echocardiogr. 2011;24:1291–318.CrossRefPubMed Troianos CA, Hartman GS, Glas KE, Councils on Intraoperative Echocardiography and Vascular Ultrasound of the American Society of Echocardiography, et al. Guidelines for performing ultrasound guided vascular cannulation: recommendations of the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists. J Am Soc Echocardiogr. 2011;24:1291–318.CrossRefPubMed
22.
Zurück zum Zitat Sticherling C, Marin F, Birnie D, et al. Antithrombotic management in patients undergoing electrophysiological procedures: a European Heart Rhythm Association (EHRA) position document endorsed by the ESC Working Group Thrombosis, Heart Rhythm Society (HRS), and Asia Pacific Heart Rhythm Society (APHRS). Europace. 2015;17:1197–214.CrossRefPubMed Sticherling C, Marin F, Birnie D, et al. Antithrombotic management in patients undergoing electrophysiological procedures: a European Heart Rhythm Association (EHRA) position document endorsed by the ESC Working Group Thrombosis, Heart Rhythm Society (HRS), and Asia Pacific Heart Rhythm Society (APHRS). Europace. 2015;17:1197–214.CrossRefPubMed
23.
Zurück zum Zitat Aouad MT, Kanazi GE, Abdallah FW, et al. Femoral vein cannulation performed by residents: a comparison between ultrasound-guided and landmark technique in infants and children undergoing cardiac surgery. Anesth Analg. 2010;111:724–8.CrossRefPubMed Aouad MT, Kanazi GE, Abdallah FW, et al. Femoral vein cannulation performed by residents: a comparison between ultrasound-guided and landmark technique in infants and children undergoing cardiac surgery. Anesth Analg. 2010;111:724–8.CrossRefPubMed
24.
Zurück zum Zitat Iwashima S, Ishikawa T, Ohzeki T. Ultrasound-guided versus landmark-guided femoral vein access in pediatric cardiac catheterization. Pediatr Cardiol. 2008;29:339–42.CrossRefPubMed Iwashima S, Ishikawa T, Ohzeki T. Ultrasound-guided versus landmark-guided femoral vein access in pediatric cardiac catheterization. Pediatr Cardiol. 2008;29:339–42.CrossRefPubMed
25.
Zurück zum Zitat Kwon TH, Kim YL, Cho DK. Ultrasound-guided cannulation of the femoral vein for acute haemodialysis access. Nephrol Dial Transplant. 1997;12:1009–12.CrossRefPubMed Kwon TH, Kim YL, Cho DK. Ultrasound-guided cannulation of the femoral vein for acute haemodialysis access. Nephrol Dial Transplant. 1997;12:1009–12.CrossRefPubMed
26.
Zurück zum Zitat Prabhu MV, Juneja D, Gopal PB, et al. Ultrasound guided femoral dialysis access placement: a single-center randomized trial. Clin J Am Soc Nephrol. 2010;5:235–9.CrossRefPubMedPubMedCentral Prabhu MV, Juneja D, Gopal PB, et al. Ultrasound guided femoral dialysis access placement: a single-center randomized trial. Clin J Am Soc Nephrol. 2010;5:235–9.CrossRefPubMedPubMedCentral
27.
Zurück zum Zitat Tanaka-Esposito CC, Chung MK, Abraham JM, et al. Real-time ultrasound guidance reduces total and major vascular complications in patients undergoing pulmonary vein antral isolation on therapeutic warfarin. J Interv Card Electrophysiol. 2013;37:163–8.CrossRefPubMedPubMedCentral Tanaka-Esposito CC, Chung MK, Abraham JM, et al. Real-time ultrasound guidance reduces total and major vascular complications in patients undergoing pulmonary vein antral isolation on therapeutic warfarin. J Interv Card Electrophysiol. 2013;37:163–8.CrossRefPubMedPubMedCentral
28.
Zurück zum Zitat Wynn GJ, Haq I, Hung J, et al. Improving safety in catheter ablation for atrial fibrillation: a prospective study of the use of ultrasound to guide vascular access. J Cardiovasc Electrophysiol. 2014;25:680–5.CrossRefPubMed Wynn GJ, Haq I, Hung J, et al. Improving safety in catheter ablation for atrial fibrillation: a prospective study of the use of ultrasound to guide vascular access. J Cardiovasc Electrophysiol. 2014;25:680–5.CrossRefPubMed
29.
Zurück zum Zitat Rodriguez Munoz D, Franco Diez E, Moreno J, et al. Wireless ultrasound guidance for femoral venous cannulation in electrophysiology: impact on safety, efficacy, and procedural delay. Pacing Clin Electrophysiol. 2015;38:1058–65.CrossRefPubMed Rodriguez Munoz D, Franco Diez E, Moreno J, et al. Wireless ultrasound guidance for femoral venous cannulation in electrophysiology: impact on safety, efficacy, and procedural delay. Pacing Clin Electrophysiol. 2015;38:1058–65.CrossRefPubMed
30.
Zurück zum Zitat Raatikainen MJ, Arnar DO, Zeppenfeld K, Merino JL, Kuck KH, Hindricks G. Current trends in the use of cardiac implantable electronic devices and interventional electrophysiological procedures in the European Society of Cardiology member countries: 2015 report from the European Heart Rhythm Association. Europace. 2015;17:iv1–iv72.CrossRefPubMed Raatikainen MJ, Arnar DO, Zeppenfeld K, Merino JL, Kuck KH, Hindricks G. Current trends in the use of cardiac implantable electronic devices and interventional electrophysiological procedures in the European Society of Cardiology member countries: 2015 report from the European Heart Rhythm Association. Europace. 2015;17:iv1–iv72.CrossRefPubMed
Metadaten
Titel
How to achieve ultrasound-guided femoral venous access: the new standard of care in the electrophysiology laboratory
verfasst von
Benedict M. Wiles
Nicholas Child
Paul R. Roberts
Publikationsdatum
07.02.2017
Verlag
Springer US
Erschienen in
Journal of Interventional Cardiac Electrophysiology / Ausgabe 1/2017
Print ISSN: 1383-875X
Elektronische ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-017-0227-9

Weitere Artikel der Ausgabe 1/2017

Journal of Interventional Cardiac Electrophysiology 1/2017 Zur Ausgabe

Update Kardiologie