Background

Osteopenia of the front half of the distal femur is a well-known problem after total knee arthroplasty (TKA) with secondary issues after years, especially when must be addressed fractures or revisions for loosening. Stress shielding has been recognized as a cause in different biomechanical studies of the bone.

Question/purposes

It was logical to look for a solution by changing the design to minimize stress shielding behind the femoral shield.

Patients and methods

It was proved that radiological measure of bone density was reliable although not so early and accurate as densitometry. We used a shield without posterior fixation of the trochlea in a series of 21 TKA with radiological measures, preoperative, at 3 months and at 5 years. We compared the results with those of a series of classical TKA in the same category of age and sex.

Results

The TKA without trochlea posterior fixation presented a significantly reduced osteopenia compared to the classical design of the femoral shield.

Conclusion

It seems that the non-fixation of the posterior surface of the trochlea may reduce osteopenia in TKA and so the risk of fractures and complications when revision surgery.

Level of evidence

2a.
Literatur
1.
Zurück zum Zitat Abu-Rajab RB, Watson WS, Walker B, Roberts J, Gallacher SJ, Meek R (2006) Peri-prosthetic bone mineral density after total knee arthroplasty: cemented versus cementless fixation. J Bone Joint Surg Br 88(5):606–613CrossRefPubMed Abu-Rajab RB, Watson WS, Walker B, Roberts J, Gallacher SJ, Meek R (2006) Peri-prosthetic bone mineral density after total knee arthroplasty: cemented versus cementless fixation. J Bone Joint Surg Br 88(5):606–613CrossRefPubMed
2.
Zurück zum Zitat Barink M, Verdonshot N, de Waal Malefit M (2003) A different fixation of the femoral component in total knee arthroplasty may lead to preservation of femoral bone stock. J Eng Med 217(5):325–332CrossRef Barink M, Verdonshot N, de Waal Malefit M (2003) A different fixation of the femoral component in total knee arthroplasty may lead to preservation of femoral bone stock. J Eng Med 217(5):325–332CrossRef
3.
Zurück zum Zitat Cameron HU, Cameron G (1987) Stress-relief osteoporosis of the anterior femoral condyles in total knee replacement: a study of 185 patients. Orthop Rev 16:449–456PubMed Cameron HU, Cameron G (1987) Stress-relief osteoporosis of the anterior femoral condyles in total knee replacement: a study of 185 patients. Orthop Rev 16:449–456PubMed
4.
Zurück zum Zitat Hernandez-Vaquero D, Garcia-Sandoval MA, Fernandez- Carreira JM, Suarez-Vázquez A, Perez-Hernández D (2005) Measurement of bone mineral density is possible with standard radiographs. A study involving total knee replacement. Acta Orthop 76(6):791–795CrossRefPubMed Hernandez-Vaquero D, Garcia-Sandoval MA, Fernandez- Carreira JM, Suarez-Vázquez A, Perez-Hernández D (2005) Measurement of bone mineral density is possible with standard radiographs. A study involving total knee replacement. Acta Orthop 76(6):791–795CrossRefPubMed
5.
Zurück zum Zitat Hirsh DM, Bhalla S, Roffman M (1981) Supracondylar fracture of the femur following total knee replacement. J Bone Joint Surg 63A:I62 Hirsh DM, Bhalla S, Roffman M (1981) Supracondylar fracture of the femur following total knee replacement. J Bone Joint Surg 63A:I62
6.
Zurück zum Zitat Karbowski A, Schwitalle M, Eckardt A, Heine J (1999) Periprosthetic bone remodelling after total knee arthroplasty: early assessment by dual energy X-ray absorptiometry. Arch Orthop Trauma Surg 119(5–6):324–326CrossRefPubMed Karbowski A, Schwitalle M, Eckardt A, Heine J (1999) Periprosthetic bone remodelling after total knee arthroplasty: early assessment by dual energy X-ray absorptiometry. Arch Orthop Trauma Surg 119(5–6):324–326CrossRefPubMed
7.
Zurück zum Zitat Kraay MJ, Goldberg VM, Figgie MP, Figgie HE (1992) Distal femoral replacement with allograft/prosthetic reconstrutcion for treatment of supracondylar fractures in patients with total knee arthroplasty. J Arthroplasty 7:7CrossRefPubMed Kraay MJ, Goldberg VM, Figgie MP, Figgie HE (1992) Distal femoral replacement with allograft/prosthetic reconstrutcion for treatment of supracondylar fractures in patients with total knee arthroplasty. J Arthroplasty 7:7CrossRefPubMed
8.
Zurück zum Zitat Lewis PL, Brewster NT, Graves SE (1998) The pathogenesis of bone loss following total knee arthroplasty. Orthop Clin North Am 29(2):187–197CrossRefPubMed Lewis PL, Brewster NT, Graves SE (1998) The pathogenesis of bone loss following total knee arthroplasty. Orthop Clin North Am 29(2):187–197CrossRefPubMed
9.
Zurück zum Zitat Mintzer CM, Robertson DD, Rackemann S, Ewald FC, Scott RD, Spector M (1990) Bone loss in the distal anterior femur after total knee arthroplasty. Clin Orthop Relat Res 260:135–143CrossRef Mintzer CM, Robertson DD, Rackemann S, Ewald FC, Scott RD, Spector M (1990) Bone loss in the distal anterior femur after total knee arthroplasty. Clin Orthop Relat Res 260:135–143CrossRef
10.
Zurück zum Zitat Mirsky EC, Einhorn TA (1998) Current concepts review. Bone densitometry in orthopaedic practice. J Bone Joint Surg (Am) 80(11):1687–1698CrossRef Mirsky EC, Einhorn TA (1998) Current concepts review. Bone densitometry in orthopaedic practice. J Bone Joint Surg (Am) 80(11):1687–1698CrossRef
11.
Zurück zum Zitat Petersen MM, Olsen C, Lauritzen JB, Lund B (1995) Changes in bone mineral density of the distal femur following uncemented total knee arthroplasty. J Arthroplasty 10(1):7–11CrossRefPubMed Petersen MM, Olsen C, Lauritzen JB, Lund B (1995) Changes in bone mineral density of the distal femur following uncemented total knee arthroplasty. J Arthroplasty 10(1):7–11CrossRefPubMed
12.
Zurück zum Zitat Robertson DD, Mintzer CM, Weissman BN, Ewald FC, LeBoff M, Spector M (1994) Distal loss of femoral bone following total knee arthroplasty. Measurement with visual and computer-processing of roentgenograms and dual-energy x-ray absorptiometry. J Bone Joint Surg (Am) 76(1):66–76CrossRef Robertson DD, Mintzer CM, Weissman BN, Ewald FC, LeBoff M, Spector M (1994) Distal loss of femoral bone following total knee arthroplasty. Measurement with visual and computer-processing of roentgenograms and dual-energy x-ray absorptiometry. J Bone Joint Surg (Am) 76(1):66–76CrossRef
13.
Zurück zum Zitat Seki T, Omori G, Koga Y, Susuki Y, Ishii Y, Takahashi HE (1999) Is bone density in the distal femur affected by use of cement and by femoral component design in total knee arthroplasty? J Orthop Sci 4(3):180–186CrossRefPubMed Seki T, Omori G, Koga Y, Susuki Y, Ishii Y, Takahashi HE (1999) Is bone density in the distal femur affected by use of cement and by femoral component design in total knee arthroplasty? J Orthop Sci 4(3):180–186CrossRefPubMed
14.
Zurück zum Zitat Soininvaara TA, Miettinen HJ, Jurvelin JS, Suomalainen OT, Alhava EM, Kröger HP (2004) Periprosthetic femoral bone loss after total knee arthroplasty: 1-year follow-up study of 69 patients. Knee 11(4):297–302CrossRefPubMed Soininvaara TA, Miettinen HJ, Jurvelin JS, Suomalainen OT, Alhava EM, Kröger HP (2004) Periprosthetic femoral bone loss after total knee arthroplasty: 1-year follow-up study of 69 patients. Knee 11(4):297–302CrossRefPubMed
15.
Zurück zum Zitat Tissakht M, Ahmed AM, Chan KC (1996) Calculated stress-shielding in the distal femur after total knee replacement corresponds to the reported location of bone loss. J Orthop Res 14(5):778–785CrossRefPubMed Tissakht M, Ahmed AM, Chan KC (1996) Calculated stress-shielding in the distal femur after total knee replacement corresponds to the reported location of bone loss. J Orthop Res 14(5):778–785CrossRefPubMed
16.
Zurück zum Zitat Van Lenthe GH, de Waal Malefijt MC, Huiskes R (1997) Stress shielding after total knee replacement may cause bone resorption in the distal femur. J Bone Joint Surg Br 79(1):117–122CrossRefPubMed Van Lenthe GH, de Waal Malefijt MC, Huiskes R (1997) Stress shielding after total knee replacement may cause bone resorption in the distal femur. J Bone Joint Surg Br 79(1):117–122CrossRefPubMed
17.
Zurück zum Zitat Van Loon CJ, de Waal Malefijt MC, Buma P, Verdonschot N, Veth RP (1999) Femoral bone loss in total knee arthroplasty. A review. Acta Orthop Belg 65(2):154–163PubMed Van Loon CJ, de Waal Malefijt MC, Buma P, Verdonschot N, Veth RP (1999) Femoral bone loss in total knee arthroplasty. A review. Acta Orthop Belg 65(2):154–163PubMed
18.
Zurück zum Zitat Wolff J (1892) Das Gesetz der Transformation der Knochen. Verlag von August Hirschwald, Berlin Wolff J (1892) Das Gesetz der Transformation der Knochen. Verlag von August Hirschwald, Berlin
Metadaten
Titel
How to reduce osteopenia in total knee arthroplasty?
verfasst von
Claude Schwartz
Publikationsdatum
16.08.2018
Verlag
Springer Paris
Erschienen in
European Journal of Orthopaedic Surgery & Traumatology / Ausgabe 1/2019
Print ISSN: 1633-8065
Elektronische ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-018-2290-z

Weitere Artikel der Ausgabe 1/2019

European Journal of Orthopaedic Surgery & Traumatology 1/2019 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.