Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 5/2008

01.05.2008 | Original Article

Hybrid Total Knee Arthroplasty

13-year Survivorship of AGC Total Knee Systems with Average 7 Years Followup

verfasst von: Philip M. Faris, MD, E. Michael Keating, MD, Alex Farris, John B. Meding, MD, Merrill A. Ritter, MD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 5/2008

Einloggen, um Zugang zu erhalten

Abstract

A retrospective study of 201 anatomic graduated component total knee arthroplasties implanted with hybrid fixation at the authors’ center was performed in response to conflicting data in the literature concerning the benefits of a hybrid method. Selection for hybrid fixation was nonrandomized and based on femoral component fit. Survivorship analysis was performed, and rates of radiolucent lines surrounding the femoral component and occurrence of osteolysis were noted. At 7 and 13 years, survivorship with tibial or femoral revision as the end point was 0.9926 and 0.9732, respectively. Radiolucencies were found adjacent to 15 femoral components at final followup (seven in Zone 1, three in Zone 2, five in Zone 3, one in Zone 4, two in Zone 5, zero in Zone 6). Osteolysis was observed in one knee after secondary evaluation. Hybrid fixation in a selected patient population can result in excellent results in middle to long-term followup.
Level of Evidence: Level IV, prognostic study. See the Guidelines for Authors for a complete description of levels of evidence.
Literatur
1.
Zurück zum Zitat Arora J, Ogden AC. Osteolysis in a surface-cemented, primary, modular Freeman-Samuelson total knee replacement. J Bone Joint Surg Br. 2005;87:1502–1506.PubMedCrossRef Arora J, Ogden AC. Osteolysis in a surface-cemented, primary, modular Freeman-Samuelson total knee replacement. J Bone Joint Surg Br. 2005;87:1502–1506.PubMedCrossRef
2.
Zurück zum Zitat Bauer GC. What price progress? Failed innovations of the knee prosthesis. Acta Orthop Scand. 1992;63:245–246.PubMedCrossRef Bauer GC. What price progress? Failed innovations of the knee prosthesis. Acta Orthop Scand. 1992;63:245–246.PubMedCrossRef
3.
Zurück zum Zitat Berry DJ, Wold LE, Rand JA. Extensive osteolysis around an aseptic, stable, uncemented total knee replacement. Clin Orthop Relat Res. 1993;293:204–207.PubMed Berry DJ, Wold LE, Rand JA. Extensive osteolysis around an aseptic, stable, uncemented total knee replacement. Clin Orthop Relat Res. 1993;293:204–207.PubMed
4.
Zurück zum Zitat Bozic KJ, Kinder J, Menegini M, Zurakowski D, Rosenberg AG, Galante JO. Implant survivorship and complication rates after total knee arthroplasty with a third-generation cemented system: 5 to 8 years followup. Clin Orthop Relat Res. 2005;430:117–124.PubMedCrossRef Bozic KJ, Kinder J, Menegini M, Zurakowski D, Rosenberg AG, Galante JO. Implant survivorship and complication rates after total knee arthroplasty with a third-generation cemented system: 5 to 8 years followup. Clin Orthop Relat Res. 2005;430:117–124.PubMedCrossRef
5.
Zurück zum Zitat Bulstrode CJ, Murray DW, Carr AJ, Pynsent PB, Carter SR. Designer hips: don’t let your patient become a fashion victim. BMJ. 1993;306:732–733.PubMedCrossRef Bulstrode CJ, Murray DW, Carr AJ, Pynsent PB, Carter SR. Designer hips: don’t let your patient become a fashion victim. BMJ. 1993;306:732–733.PubMedCrossRef
6.
Zurück zum Zitat Campbell MD, Duffy GP, Trousdale RT. Femoral component failure in hybrid total knee arthroplasty. Clin Orthop Relat Res. 1998;356:58–65.PubMedCrossRef Campbell MD, Duffy GP, Trousdale RT. Femoral component failure in hybrid total knee arthroplasty. Clin Orthop Relat Res. 1998;356:58–65.PubMedCrossRef
7.
Zurück zum Zitat Carlsson Å, Björkman A, Besjakov J, Önsten I. Cemented tibial component fixation performs better than cementless fixation: a randomized radiostereometric study comparing porous-coated, hydroxyapatite-coated and cemented tibial components over 5 years. Acta Orthop. 2005;76:362–369.PubMedCrossRef Carlsson Å, Björkman A, Besjakov J, Önsten I. Cemented tibial component fixation performs better than cementless fixation: a randomized radiostereometric study comparing porous-coated, hydroxyapatite-coated and cemented tibial components over 5 years. Acta Orthop. 2005;76:362–369.PubMedCrossRef
8.
Zurück zum Zitat Collier JP, Mayor MB, Surprenant VA, Dauphinais LA, Surprenant HP, Jensen RE, Chae JC, Spector M, Shortkroff S, Sledge CB, et al. Advances in implant-bone interface. Instr Course Lect. 1991;40:89–113.PubMed Collier JP, Mayor MB, Surprenant VA, Dauphinais LA, Surprenant HP, Jensen RE, Chae JC, Spector M, Shortkroff S, Sledge CB, et al. Advances in implant-bone interface. Instr Course Lect. 1991;40:89–113.PubMed
9.
Zurück zum Zitat Collier MB, Engh CA Jr, McAuley JP, Ginn SD, Engh GA. Osteolysis after total knee arthroplasty: influence of tibial baseplate surface finish and sterilization of polyethylene insert. J Bone Joint Surg Am. 2005;87:2702–2708.PubMedCrossRef Collier MB, Engh CA Jr, McAuley JP, Ginn SD, Engh GA. Osteolysis after total knee arthroplasty: influence of tibial baseplate surface finish and sterilization of polyethylene insert. J Bone Joint Surg Am. 2005;87:2702–2708.PubMedCrossRef
10.
Zurück zum Zitat Conditt MA, Thompson MT, Usrey MM, Ismaily SK, Noble PC. Backside wear of polyethylene tibial inserts: mechanism and magnitude of material loss. J Bone Joint Surg Am. 2005;87:326–331.PubMedCrossRef Conditt MA, Thompson MT, Usrey MM, Ismaily SK, Noble PC. Backside wear of polyethylene tibial inserts: mechanism and magnitude of material loss. J Bone Joint Surg Am. 2005;87:326–331.PubMedCrossRef
11.
Zurück zum Zitat Cook SD, Thomas KA, Haddad RJ Jr. Histologic analysis of retrieved human porous-coated total joint components. Clin Orthop Relat Res. 1988;234:90–101.PubMed Cook SD, Thomas KA, Haddad RJ Jr. Histologic analysis of retrieved human porous-coated total joint components. Clin Orthop Relat Res. 1988;234:90–101.PubMed
12.
Zurück zum Zitat Duffy GP, Berry DJ, Rand JA. Cement versus cementless fixation in total knee arthroplasty. Clin Orthop Relat Res. 1998;356:66–72.PubMedCrossRef Duffy GP, Berry DJ, Rand JA. Cement versus cementless fixation in total knee arthroplasty. Clin Orthop Relat Res. 1998;356:66–72.PubMedCrossRef
13.
Zurück zum Zitat Duffy GP, Murray BE, Trousdale RR. Hybrid total knee arthroplasty: analysis of component failures at an average of 15 years. J Arthroplasty. 2007;22:1112–1115.PubMedCrossRef Duffy GP, Murray BE, Trousdale RR. Hybrid total knee arthroplasty: analysis of component failures at an average of 15 years. J Arthroplasty. 2007;22:1112–1115.PubMedCrossRef
14.
Zurück zum Zitat Engh GA, Dwyer KA, Hanes CK. Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses. J Bone Joint Surg Br. 1992;74:9–17.PubMed Engh GA, Dwyer KA, Hanes CK. Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses. J Bone Joint Surg Br. 1992;74:9–17.PubMed
15.
Zurück zum Zitat Engh GA, Parks NL, Ammeen DJ. Tibial osteolysis in cementless total knee arthroplasty: a review of 25 cases treated with and without tibial component revision. Clin Orthop Relat Res. 1994;309:33–43.PubMed Engh GA, Parks NL, Ammeen DJ. Tibial osteolysis in cementless total knee arthroplasty: a review of 25 cases treated with and without tibial component revision. Clin Orthop Relat Res. 1994;309:33–43.PubMed
16.
Zurück zum Zitat Ezzet KA, Garcia R, Barrack RL. Effect of component fixation method on osteolysis in total knee arthroplasty. Clin Orthop Relat Res. 1995;321:86–91.PubMed Ezzet KA, Garcia R, Barrack RL. Effect of component fixation method on osteolysis in total knee arthroplasty. Clin Orthop Relat Res. 1995;321:86–91.PubMed
17.
Zurück zum Zitat Furnes O, Espehaug B, Lie SA, Furnes O, Havelin LI. Early failures among 7,174 primary total knee replacements: a follow-up study from the Norwegian Arthroplasty Register 1994–2000. Acta Orthop Scand. 2002;73:117–129.PubMedCrossRef Furnes O, Espehaug B, Lie SA, Furnes O, Havelin LI. Early failures among 7,174 primary total knee replacements: a follow-up study from the Norwegian Arthroplasty Register 1994–2000. Acta Orthop Scand. 2002;73:117–129.PubMedCrossRef
18.
Zurück zum Zitat Gioe TJ, Bowman KR. A randomized comparison of all-polyethylene and metal-backed tibial components. Clin Orthop Relat Res. 2000;380:108–115.PubMedCrossRef Gioe TJ, Bowman KR. A randomized comparison of all-polyethylene and metal-backed tibial components. Clin Orthop Relat Res. 2000;380:108–115.PubMedCrossRef
19.
Zurück zum Zitat Gioe TJ, Killeen KK, Grimm K, Mehle S, Scheltema K. Why are total knee replacements revised?: analysis of early revision in a community knee implant registry. Clin Orthop Relat Res. 2004;428:100–106.PubMedCrossRef Gioe TJ, Killeen KK, Grimm K, Mehle S, Scheltema K. Why are total knee replacements revised?: analysis of early revision in a community knee implant registry. Clin Orthop Relat Res. 2004;428:100–106.PubMedCrossRef
20.
Zurück zum Zitat Goldberg VM, Kraay M. The outcome of the cementless tibial component: a minimum 14-year clinical evaluation. Clin Orthop Relat Res. 2004;428:214–220.PubMedCrossRef Goldberg VM, Kraay M. The outcome of the cementless tibial component: a minimum 14-year clinical evaluation. Clin Orthop Relat Res. 2004;428:214–220.PubMedCrossRef
21.
Zurück zum Zitat Goodfellow J. Editorials. Knee prostheses—one step forward, two steps back. J Bone Joint Surg Br. 1992;74:1–2.PubMed Goodfellow J. Editorials. Knee prostheses—one step forward, two steps back. J Bone Joint Surg Br. 1992;74:1–2.PubMed
22.
Zurück zum Zitat Hsu RW, Tsai YH, Huang TJ, Chang JC. Hybrid total knee arthroplasty: a 3- to 6-year outcome analysis. J Formos Med Assoc. 1998;97:410–415.PubMed Hsu RW, Tsai YH, Huang TJ, Chang JC. Hybrid total knee arthroplasty: a 3- to 6-year outcome analysis. J Formos Med Assoc. 1998;97:410–415.PubMed
23.
Zurück zum Zitat Huang CH, Ma HM, Liau JJ, Ho FY, Cheng CK. Osteolysis in failed total knee arthroplasty: a comparison of mobile-bearing and fixed-bearing knees. J Bone Joint Surg Am. 2002;84:2224–2229.PubMed Huang CH, Ma HM, Liau JJ, Ho FY, Cheng CK. Osteolysis in failed total knee arthroplasty: a comparison of mobile-bearing and fixed-bearing knees. J Bone Joint Surg Am. 2002;84:2224–2229.PubMed
24.
Zurück zum Zitat Illgen R, Tueting J, Enright T, Schreibman K, McBeath A, Heiner J. Hybrid total knee arthroplasty: a retrospective analysis of clinical and radiographic outcomes at average 10 years follow-up. J Arthroplasty. 2004;19(7 suppl 2):95–100.PubMedCrossRef Illgen R, Tueting J, Enright T, Schreibman K, McBeath A, Heiner J. Hybrid total knee arthroplasty: a retrospective analysis of clinical and radiographic outcomes at average 10 years follow-up. J Arthroplasty. 2004;19(7 suppl 2):95–100.PubMedCrossRef
25.
Zurück zum Zitat Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:457–481.CrossRef Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:457–481.CrossRef
26.
Zurück zum Zitat Kilgus DJ, Funahashi TT, Campbell PA. Massive femoral osteolysis and early disintegration of a polyethylene-bearing surface of a total knee replacement: a case report. J Bone Joint Surg Am. 1992;74:770–774.PubMed Kilgus DJ, Funahashi TT, Campbell PA. Massive femoral osteolysis and early disintegration of a polyethylene-bearing surface of a total knee replacement: a case report. J Bone Joint Surg Am. 1992;74:770–774.PubMed
27.
Zurück zum Zitat Kim YH, Oh JH, Oh SH. Osteolysis around cementless porous-coated anatomic knee prostheses. J Bone Joint Surg Br. 1995;77:236–241.PubMed Kim YH, Oh JH, Oh SH. Osteolysis around cementless porous-coated anatomic knee prostheses. J Bone Joint Surg Br. 1995;77:236–241.PubMed
28.
Zurück zum Zitat Kobs JK, Lachiewicz PF. Hybrid total knee arthroplasty: two- to five-year results using the Miller-Galante prosthesis. Clin Orthop Relat Res. 1993;286:78–87.PubMed Kobs JK, Lachiewicz PF. Hybrid total knee arthroplasty: two- to five-year results using the Miller-Galante prosthesis. Clin Orthop Relat Res. 1993;286:78–87.PubMed
29.
Zurück zum Zitat König A, Kirschner S, Walther M, Eisert M, Eulert J. Hybrid total knee arthroplasty. Arch Orthop Trauma Surg. 1998;118:66–69.PubMedCrossRef König A, Kirschner S, Walther M, Eisert M, Eulert J. Hybrid total knee arthroplasty. Arch Orthop Trauma Surg. 1998;118:66–69.PubMedCrossRef
30.
Zurück zum Zitat Kraay MJ, Meyers SA, Goldberg VM, Figgie HE II, Conroy PA. “Hybrid” total knee arthroplasty with the Miller-Galante prosthesis: a prospective clinical and roentgenographic evaluation. Clin Orthop Relat Res. 1991;273:32–41.PubMed Kraay MJ, Meyers SA, Goldberg VM, Figgie HE II, Conroy PA. “Hybrid” total knee arthroplasty with the Miller-Galante prosthesis: a prospective clinical and roentgenographic evaluation. Clin Orthop Relat Res. 1991;273:32–41.PubMed
31.
Zurück zum Zitat Lachiewicz PF, Soileau ES. The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement: results at 5–14 years. J Bone Joint Surg Am. 2004;86:525–530.PubMedCrossRef Lachiewicz PF, Soileau ES. The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement: results at 5–14 years. J Bone Joint Surg Am. 2004;86:525–530.PubMedCrossRef
32.
Zurück zum Zitat Lewis P, Rorabeck CH, Bourne RB, Devane P. Posteromedial tibial polyethylene failure in total knee replacements. Clin Orthop Relat Res. 1994;299:11–17.PubMed Lewis P, Rorabeck CH, Bourne RB, Devane P. Posteromedial tibial polyethylene failure in total knee replacements. Clin Orthop Relat Res. 1994;299:11–17.PubMed
33.
Zurück zum Zitat Li MG, Nilsson KG. The effect of the preoperative bone quality on the fixation of the tibial component in total knee arthroplasty. J Arthroplasty. 2000;15:744–753.PubMedCrossRef Li MG, Nilsson KG. The effect of the preoperative bone quality on the fixation of the tibial component in total knee arthroplasty. J Arthroplasty. 2000;15:744–753.PubMedCrossRef
34.
Zurück zum Zitat Mitsui H. Hybrid total knee arthroplasties in rheumatoid arthritis. Bull Hosp Jt Dis. 1993;53:19–20.PubMed Mitsui H. Hybrid total knee arthroplasties in rheumatoid arthritis. Bull Hosp Jt Dis. 1993;53:19–20.PubMed
35.
Zurück zum Zitat Miura H, Matsuda S, Okazaki K, Kawano T, Kawamura H, Iwamoto Y. Validity of an oblique posterior condylar radiographic view for revision total knee arthroplasty. J Bone Joint Surg Br. 2005;87:1643–1646.PubMedCrossRef Miura H, Matsuda S, Okazaki K, Kawano T, Kawamura H, Iwamoto Y. Validity of an oblique posterior condylar radiographic view for revision total knee arthroplasty. J Bone Joint Surg Br. 2005;87:1643–1646.PubMedCrossRef
36.
Zurück zum Zitat O’Rourke MR, Callaghan JJ, Goetz DD, Sullivan PM, Johnston RC. Osteolysis associated with a cemented modular posterior-cruciate-substituting total knee design: five to eight-year follow-up. J Bone Joint Surg Am. 2002;84:1362–1371.PubMed O’Rourke MR, Callaghan JJ, Goetz DD, Sullivan PM, Johnston RC. Osteolysis associated with a cemented modular posterior-cruciate-substituting total knee design: five to eight-year follow-up. J Bone Joint Surg Am. 2002;84:1362–1371.PubMed
37.
Zurück zum Zitat Peters PC Jr, Engh GA, Dwyer KA, Vinh TN. Osteolysis after total knee arthroplasty without cement. J Bone Joint Surg Am. 1992;74:864–876.PubMed Peters PC Jr, Engh GA, Dwyer KA, Vinh TN. Osteolysis after total knee arthroplasty without cement. J Bone Joint Surg Am. 1992;74:864–876.PubMed
38.
Zurück zum Zitat Puloske SK, McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB. Tibial post wear in posterior stabilized total knee arthroplasty: an unrecognized source of polyethylene debris. J Bone Joint Surg Am. 2001;83:390–397. Puloske SK, McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB. Tibial post wear in posterior stabilized total knee arthroplasty: an unrecognized source of polyethylene debris. J Bone Joint Surg Am. 2001;83:390–397.
39.
Zurück zum Zitat Rand JA, Ilstrup DM. Survivorship analysis of total knee arthroplasty: cumulative rates of survival of 9200 total knee arthroplasties. J Bone Joint Surg Am. 1991;73:397–409.PubMed Rand JA, Ilstrup DM. Survivorship analysis of total knee arthroplasty: cumulative rates of survival of 9200 total knee arthroplasties. J Bone Joint Surg Am. 1991;73:397–409.PubMed
40.
Zurück zum Zitat Rand JA, Trousdale RT, Ilstrup DM, Harmsen WS. Factors affecting the durability of primary total knee prostheses. J Bone Joint Surg Am. 2003;85:259–265.PubMed Rand JA, Trousdale RT, Ilstrup DM, Harmsen WS. Factors affecting the durability of primary total knee prostheses. J Bone Joint Surg Am. 2003;85:259–265.PubMed
41.
Zurück zum Zitat Rao AR, Engh GA, Collier MB, Lounici S. Tibial interface wear in retrieved total knee components and correlations with modular insert motion. J Bone Joint Surg Am. 2002;84:1849–1855.PubMed Rao AR, Engh GA, Collier MB, Lounici S. Tibial interface wear in retrieved total knee components and correlations with modular insert motion. J Bone Joint Surg Am. 2002;84:1849–1855.PubMed
42.
Zurück zum Zitat Ritter MA. Screw and cement fixation of large defects in total knee arthroplasty. J Arthroplasty. 1986;1:125–129.PubMedCrossRef Ritter MA. Screw and cement fixation of large defects in total knee arthroplasty. J Arthroplasty. 1986;1:125–129.PubMedCrossRef
43.
Zurück zum Zitat Ritter MA, Berend ME, Meding JB, Keating EM, Faris PM, Crites BM. Long-term follow-up of Anatomic Graduated Components posterior cruciate-retaining total knee replacement. Clin Orthop Relat Res. 2001;388:51–57.PubMedCrossRef Ritter MA, Berend ME, Meding JB, Keating EM, Faris PM, Crites BM. Long-term follow-up of Anatomic Graduated Components posterior cruciate-retaining total knee replacement. Clin Orthop Relat Res. 2001;388:51–57.PubMedCrossRef
44.
Zurück zum Zitat Ritter MA, Harty LD. Medial screws and cement: a possible mechanical augmentation in total knee arthroplasty. J Arthroplasty. 2004;19:587–589.PubMedCrossRef Ritter MA, Harty LD. Medial screws and cement: a possible mechanical augmentation in total knee arthroplasty. J Arthroplasty. 2004;19:587–589.PubMedCrossRef
45.
Zurück zum Zitat Ritter MA, Herbst SA, Keating EM, Faris PM, Meding JB. Long-term survival analysis of a posterior-cruciate-retaining total condylar total knee arthroplasty. Clin Orthop Relat Res. 1994;309:136–145.PubMed Ritter MA, Herbst SA, Keating EM, Faris PM, Meding JB. Long-term survival analysis of a posterior-cruciate-retaining total condylar total knee arthroplasty. Clin Orthop Relat Res. 1994;309:136–145.PubMed
46.
Zurück zum Zitat Ritter MA, Keating EM, Faris PM. Screw and cement fixation of large defects in total knee arthroplasty a sequel. J Arthroplasty. 1993;8:63–65.PubMed Ritter MA, Keating EM, Faris PM. Screw and cement fixation of large defects in total knee arthroplasty a sequel. J Arthroplasty. 1993;8:63–65.PubMed
47.
Zurück zum Zitat Robinson EJ, Mulliken BD, Bourne RB, Rorabeck CH, Alvarez C. Catastrophic osteolysis in total knee replacement: a report of 17 cases. Clin Orthop Relat Res. 1995;321:98–105.PubMed Robinson EJ, Mulliken BD, Bourne RB, Rorabeck CH, Alvarez C. Catastrophic osteolysis in total knee replacement: a report of 17 cases. Clin Orthop Relat Res. 1995;321:98–105.PubMed
48.
Zurück zum Zitat Rodriguez JA, Baez N, Rasquinha V, Ranawat CS. Metal-backed and all-polyethylene tibial components in total knee replacement. Clin Orthop Relat Res. 2001;392:174–183.PubMedCrossRef Rodriguez JA, Baez N, Rasquinha V, Ranawat CS. Metal-backed and all-polyethylene tibial components in total knee replacement. Clin Orthop Relat Res. 2001;392:174–183.PubMedCrossRef
49.
Zurück zum Zitat Rorabeck CH, Bourne RB, Lewis PL, Nott L. The Miller-Galante knee prosthesis for the treatment of osteoarthrosis: a comparison of the results of partial fixation with cement and fixation without any cement. J Bone Joint Surg Am. 1993;75:402–408.PubMed Rorabeck CH, Bourne RB, Lewis PL, Nott L. The Miller-Galante knee prosthesis for the treatment of osteoarthrosis: a comparison of the results of partial fixation with cement and fixation without any cement. J Bone Joint Surg Am. 1993;75:402–408.PubMed
50.
Zurück zum Zitat Schmalzried TP, Callaghan JJ. Current concepts review: wear in total hip and knee replacements. J Bone Joint Surg Am. 1999;81:115–136.PubMed Schmalzried TP, Callaghan JJ. Current concepts review: wear in total hip and knee replacements. J Bone Joint Surg Am. 1999;81:115–136.PubMed
51.
Zurück zum Zitat Schrøder HM, Berthelsen A, Hassani G, Hansen EB, Solgaard S. Cementless porous-coated total knee arthroplasty: 10-year results in a consecutive series. J Arthroplasty. 2001;16:559–567.PubMedCrossRef Schrøder HM, Berthelsen A, Hassani G, Hansen EB, Solgaard S. Cementless porous-coated total knee arthroplasty: 10-year results in a consecutive series. J Arthroplasty. 2001;16:559–567.PubMedCrossRef
52.
Zurück zum Zitat Smith S, Naima VS, Freeman MA. The natural history of tibial radiolucent lines in a proximally cemented stemmed total knee arthroplasty. J Arthroplasty. 1998;13:3–8. Smith S, Naima VS, Freeman MA. The natural history of tibial radiolucent lines in a proximally cemented stemmed total knee arthroplasty. J Arthroplasty. 1998;13:3–8.
53.
Zurück zum Zitat Tanner MG, Whiteside LA, White SE. Effect of polyethylene quality on wear in total knee arthroplasty. Clin Orthop Relat Res. 1995;317:83–88.PubMed Tanner MG, Whiteside LA, White SE. Effect of polyethylene quality on wear in total knee arthroplasty. Clin Orthop Relat Res. 1995;317:83–88.PubMed
54.
Zurück zum Zitat Vigorita VJ, Minkowitz B, Dichiara JF, Higham PA. A histomorphometric and histologic analysis of the implant interface in five successful, autopsy-retrieved, noncemented porous-coated knee arthroplasties. Clin Orthop Relat Res. 1993;293:211–218.PubMed Vigorita VJ, Minkowitz B, Dichiara JF, Higham PA. A histomorphometric and histologic analysis of the implant interface in five successful, autopsy-retrieved, noncemented porous-coated knee arthroplasties. Clin Orthop Relat Res. 1993;293:211–218.PubMed
55.
Zurück zum Zitat Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res. 1994;299:31–43.PubMed Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res. 1994;299:31–43.PubMed
56.
Zurück zum Zitat Wasielewski RC, Parks N, Williams SI, Surprenant H, Collier JP, Engh G. Tibia insert undersurface as a contributing source of polyethylene wear debris. Clin Orthop Relat Res. 1997;345:53–59.PubMedCrossRef Wasielewski RC, Parks N, Williams SI, Surprenant H, Collier JP, Engh G. Tibia insert undersurface as a contributing source of polyethylene wear debris. Clin Orthop Relat Res. 1997;345:53–59.PubMedCrossRef
57.
Zurück zum Zitat Whiteside LA. Effect of porous-coating configuration on tibial osteolysis after total knee arthroplasty. Clin Orthop Relat Res. 1995;321:92–97.PubMed Whiteside LA. Effect of porous-coating configuration on tibial osteolysis after total knee arthroplasty. Clin Orthop Relat Res. 1995;321:92–97.PubMed
58.
Zurück zum Zitat Wright RJ, Lima J, Scott RD, Thornhill TS. Two- to four-year results of posterior cruciate-sparing condylar total knee arthroplasty with an uncemented femoral component. Clin Orthop Relat Res. 1990;260:80–86.PubMed Wright RJ, Lima J, Scott RD, Thornhill TS. Two- to four-year results of posterior cruciate-sparing condylar total knee arthroplasty with an uncemented femoral component. Clin Orthop Relat Res. 1990;260:80–86.PubMed
Metadaten
Titel
Hybrid Total Knee Arthroplasty
13-year Survivorship of AGC Total Knee Systems with Average 7 Years Followup
verfasst von
Philip M. Faris, MD
E. Michael Keating, MD
Alex Farris
John B. Meding, MD
Merrill A. Ritter, MD
Publikationsdatum
01.05.2008
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 5/2008
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-008-0195-6

Weitere Artikel der Ausgabe 5/2008

Clinical Orthopaedics and Related Research® 5/2008 Zur Ausgabe

Case Report

Case Report

Symposium: Molecular and Surgical Advances in Osteonecrosis

Transtrochanteric Posterior Rotational Osteotomy for Osteonecrosis

Orthopaedic • Radiology • Pathology Conference

Knee Lesion in a 62-year-old Woman

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.