Identification of anterior chamber angle parameters with a portable SD-OCT device compared to a non-portable SD-OCT

Zeitschrift:
International Ophthalmology > Ausgabe 1/2017
Autoren:
Handan Akil, Kenneth Marion, Anna Dastiridou, Dennis Jenkins, Brendan Kramer, Brian A. Francis, Vikas Chopra

Abstract

The aim of this study is to compare a portable spectral domain optical coherence tomography (SD-OCT) device with a non-portable SD-OCT for the identification of anterior chamber angle parameters based on location of Schwalbe’s line (SL) and to measure their reproducibility. 99 eyes from 46 normal, healthy participants underwent imaging of the inferior iridocorneal angle with the iVue and Cirrus SD-OCT under well-controlled low-light conditions. SL-angle opening distance (SL-AOD) and SL-trabecular iris space area (SL-TISA) were measured by masked, certified graders at the Doheny Image Reading Center using customized Image J grading software. Inter- and intrainstrument, as well as inter- and intraobserver reproducibility of SL-AOD and SL-TISA measurements were evaluated with intraclass correlation coefficients (ICCs) and Bland–Altman plots with limits of agreement. The mean SL-AOD was 0.814 ± 0.315 mm with the iVue and 0.797 ± 0.294 mm with the Cirrus. The mean SL-TISA was 0.247 ± 0.112 mm2 with iVue and 0.259 ± 0.113 mm2 with Cirrus. Interinstrument correlation coefficients (r) were 0.93 (P < 0.0001), 0.92 (P < 0.0001), and 0.92 (P < 0.0001) for SL_AOD and SL_TISA, respectively. Intraclass correlation coefficient showing the degree of agreement among SL-AOD and SL-TISA was 0.923 (95 % confidence interval 0.885–0.948) and 0.921 (95 % confidence interval 0.883–0.947) for both devices. The agreement for intrainstrument (ICCs > 0.95), intragrader (ICCs > 0.93), and intergrader (ICCs > 0.96) was excellent. Excellent agreement between the two devices was also documented with Bland–Altman analysis. Both instruments provide consistent and reproducible measurements of anterior chamber angle metrics.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag als Mediziner

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Jetzt e.Med zum Sonderpreis bestellen!

Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 1/2017

International Ophthalmology 1/2017 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

28.08.2020 | Leitthema | Ausgabe 10/2020

Künstliche Intelligenz in der Augenheilkunde

Leitfaden für Ärzte zur kritischen Bewertung von Studien