Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 5/2019

17.01.2019 | Original Paper

Image quality and radiation dose of two prospective ECG-triggered protocols using 128-slice dual-source CT angiography in infants with congenital heart disease

verfasst von: Baojin Chen, Shuo Zhao, Yang Gao, Zhaoping Cheng, Yanhua Duan, Pritam Das, Ximing Wang

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 5/2019

Einloggen, um Zugang zu erhalten

Abstract

This study aims to investigate the image quality and radiation dose of prospective ECG-triggered 128-slice dual-source CT (DSCT) angiography in the delineation of coronary arteries in infants with congenital heart disease (CHD). Sixty-three infants with CHD were randomly assigned into two groups: prospective ECG-triggered sequential protocol (group 1) and high-pitch spiral protocol (group 2). Patients were selected to the protocols randomly. A five-point scoring system was applied to study the capability of detecting coronary arteries. A score of < 3 represents non-diagnostic. Effective radiation dose (ED) was calculated. The visualized rate for original, proximal, middle and distal segments of the coronary arteries was 98%, 95%, 94% and 83%, respectively in group 1, 93%, 82%, 53% and 34%, respectively in group 2. There were no significant demographic differences in the identification rate between the two groups as to the original and most of the proximal segments. Significant demographic differences were found in middle and distal segments (p < 0.05). The mean ED of the high pitch group and the sequential group was 0.33 ± 0.11 mSv and 0.63 ± 0.16 mSv, respectively. Both the prospective ECG-gated high-pitch mode and the sequential mode for 128-slice DSCT allow satisfactory delineation of original and most of the proximal segments of coronary arteries in infants with CHD. However, an ECG-gated sequential mode is recommended when detailed anatomic assessment of the whole coronary arteries are needed since the ECG-gated high-pitch mode is limited in the delineation of middle and distal segments of the coronary arteries.
Literatur
1.
Zurück zum Zitat Goo HW, Seo DM, Yun TJ, Park JJ, Park IS, Ko JK, Kim YH (2009) Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: multislice CT findings. Pediatr Radiol 39(3):265–273CrossRefPubMed Goo HW, Seo DM, Yun TJ, Park JJ, Park IS, Ko JK, Kim YH (2009) Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: multislice CT findings. Pediatr Radiol 39(3):265–273CrossRefPubMed
2.
Zurück zum Zitat Yu FF, Lu B, Gao Y, Hou ZH, Schoepf UJ, Spearman JV, Cao HL, Sun ML, Jiang SL (2013) Congenital anomalies of coronary arteries in complex congenital heart disease: diagnosis and analysis with dual-source CT. J Cardiovasc Comput Tomogr 7(6):383–390CrossRefPubMed Yu FF, Lu B, Gao Y, Hou ZH, Schoepf UJ, Spearman JV, Cao HL, Sun ML, Jiang SL (2013) Congenital anomalies of coronary arteries in complex congenital heart disease: diagnosis and analysis with dual-source CT. J Cardiovasc Comput Tomogr 7(6):383–390CrossRefPubMed
3.
Zurück zum Zitat Lowry AW, Olabiyi OO, Adachi I, Moodie DS, Knudson JD (2013) Coronary artery anatomy in congenital heart disease. Congenit Heart Dis 8(3):187–202CrossRefPubMed Lowry AW, Olabiyi OO, Adachi I, Moodie DS, Knudson JD (2013) Coronary artery anatomy in congenital heart disease. Congenit Heart Dis 8(3):187–202CrossRefPubMed
4.
Zurück zum Zitat Zhang Q, Duan Y, Hongxin L, Wenbin G (2017) An innovative technique of perventricular device closure of a coronary artery fistula through a left parasternal approach. Eur Heart J 38(42):3177CrossRefPubMed Zhang Q, Duan Y, Hongxin L, Wenbin G (2017) An innovative technique of perventricular device closure of a coronary artery fistula through a left parasternal approach. Eur Heart J 38(42):3177CrossRefPubMed
5.
Zurück zum Zitat Angeli E, Formigari R, Pace Napoleone C, Oppido G, Ragni L, Picchio FM, Gargiulo G (2010) Long-term coronary artery outcome after arterial switch operation for transposition of the great arteries. Eur J Cardio-thorac Surg 38(6):714–720CrossRef Angeli E, Formigari R, Pace Napoleone C, Oppido G, Ragni L, Picchio FM, Gargiulo G (2010) Long-term coronary artery outcome after arterial switch operation for transposition of the great arteries. Eur J Cardio-thorac Surg 38(6):714–720CrossRef
6.
Zurück zum Zitat Yao LP, Zhang L, Li HM, Ding M, Yu LW, Yang X, Li XM, Sun K (2017) Assessment of coronary artery by prospective ECG-triggered 256 multi-slice CT on children with congenital heart disease. Int J Cardiovasc Imaging 33(12):2021–2028CrossRefPubMed Yao LP, Zhang L, Li HM, Ding M, Yu LW, Yang X, Li XM, Sun K (2017) Assessment of coronary artery by prospective ECG-triggered 256 multi-slice CT on children with congenital heart disease. Int J Cardiovasc Imaging 33(12):2021–2028CrossRefPubMed
7.
Zurück zum Zitat Goo HW (2018) Identification of coronary artery anatomy on dual-source cardiac computed tomography before arterial switch operation in newborns and young infants: comparison with transthoracic echocardiography. Pediatr Radiol 48(2):176–185CrossRefPubMed Goo HW (2018) Identification of coronary artery anatomy on dual-source cardiac computed tomography before arterial switch operation in newborns and young infants: comparison with transthoracic echocardiography. Pediatr Radiol 48(2):176–185CrossRefPubMed
8.
Zurück zum Zitat Kanie Y, Sato S, Tada A, Kanazawa S (2017) Image quality of coronary arteries on non-electrocardiography-gated high-pitch dual-source computed tomography in children with congenital heart disease. Pediatr Cardiol 38(7):1393–1399CrossRefPubMed Kanie Y, Sato S, Tada A, Kanazawa S (2017) Image quality of coronary arteries on non-electrocardiography-gated high-pitch dual-source computed tomography in children with congenital heart disease. Pediatr Cardiol 38(7):1393–1399CrossRefPubMed
9.
Zurück zum Zitat Han BK, Lindberg J, Grant K, Schwartz RS, Lesser JR (2011) Accuracy and safety of high pitch computed tomography imaging in young children with complex congenital heart disease. Am J Cardiol 107(10):1541–1546CrossRefPubMed Han BK, Lindberg J, Grant K, Schwartz RS, Lesser JR (2011) Accuracy and safety of high pitch computed tomography imaging in young children with complex congenital heart disease. Am J Cardiol 107(10):1541–1546CrossRefPubMed
10.
Zurück zum Zitat Goo HW (2010) State-of-the-art CT imaging techniques for congenital heart disease. Korean J Radiol 11(1):4–18CrossRefPubMed Goo HW (2010) State-of-the-art CT imaging techniques for congenital heart disease. Korean J Radiol 11(1):4–18CrossRefPubMed
11.
Zurück zum Zitat Li T, Zhao S, Liu J, Yang L, Huang Z, Li J, Luo C, Li X (2017) Feasibility of high-pitch spiral dual-source CT angiography in children with complex congenital heart disease compared to retrospective-gated spiral acquisition. Clin Radiol 72(10):864–870CrossRefPubMed Li T, Zhao S, Liu J, Yang L, Huang Z, Li J, Luo C, Li X (2017) Feasibility of high-pitch spiral dual-source CT angiography in children with complex congenital heart disease compared to retrospective-gated spiral acquisition. Clin Radiol 72(10):864–870CrossRefPubMed
12.
Zurück zum Zitat Young C, Taylor AM, Owens CM (2011) Paediatric cardiac computed tomography: a review of imaging techniques and radiation dose consideration. Eur Radiol 21(3):518–529CrossRefPubMed Young C, Taylor AM, Owens CM (2011) Paediatric cardiac computed tomography: a review of imaging techniques and radiation dose consideration. Eur Radiol 21(3):518–529CrossRefPubMed
13.
Zurück zum Zitat Nie P, Wang X, Cheng Z, Ji X, Duan Y, Chen J (2012) Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease. Eur Radiol 22(10):2057–2066CrossRefPubMed Nie P, Wang X, Cheng Z, Ji X, Duan Y, Chen J (2012) Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease. Eur Radiol 22(10):2057–2066CrossRefPubMed
14.
Zurück zum Zitat Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–174CrossRef Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–174CrossRef
15.
Zurück zum Zitat Cheng Z, Wang X, Duan Y, Wu L, Wu D, Chao B, Liu C, Xu Z, Li H, Liang F, Xu J, Chen J (2010) Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience. Eur Radiol 20(10):2503–2511CrossRefPubMed Cheng Z, Wang X, Duan Y, Wu L, Wu D, Chao B, Liu C, Xu Z, Li H, Liang F, Xu J, Chen J (2010) Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience. Eur Radiol 20(10):2503–2511CrossRefPubMed
16.
Zurück zum Zitat Goo HW, Yang DH (2010) Coronary artery visibility in free-breathing young children with congenital heart disease on cardiac 64-slice CT: dual-source ECG-triggered sequential scan vs. single-source non-ECG-synchronized spiral scan. Pediatr Radiol 40(10):1670–1680CrossRefPubMed Goo HW, Yang DH (2010) Coronary artery visibility in free-breathing young children with congenital heart disease on cardiac 64-slice CT: dual-source ECG-triggered sequential scan vs. single-source non-ECG-synchronized spiral scan. Pediatr Radiol 40(10):1670–1680CrossRefPubMed
17.
Zurück zum Zitat Ben Saad M, Rohnean A, Sigal-Cinqualbre A, Adler G, Paul JF (2009) Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease. Pediatr Radiol 39(7):668–676CrossRefPubMed Ben Saad M, Rohnean A, Sigal-Cinqualbre A, Adler G, Paul JF (2009) Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease. Pediatr Radiol 39(7):668–676CrossRefPubMed
18.
Zurück zum Zitat Esser M, Gatidis S, Teufel M, Ketelsen I, Nikolaou K, Schafer JF, Tsiflikas I (2017) Contrast-enhanced high-pitch computed tomography in pediatric patients without electrocardiography triggering and sedation: comparison of cardiac image quality with conventional multidetector computed tomography. J Comput Assist Tomogr 41(1):165–171CrossRefPubMed Esser M, Gatidis S, Teufel M, Ketelsen I, Nikolaou K, Schafer JF, Tsiflikas I (2017) Contrast-enhanced high-pitch computed tomography in pediatric patients without electrocardiography triggering and sedation: comparison of cardiac image quality with conventional multidetector computed tomography. J Comput Assist Tomogr 41(1):165–171CrossRefPubMed
20.
Zurück zum Zitat Ait-Ali L, Andreassi MG, Foffa I, Spadoni I, Vano E, Picano E (2010) Cumulative patient effective dose and acute radiation-induced chromosomal DNA damage in children with congenital heart disease. Heart 96(4):269–274CrossRefPubMed Ait-Ali L, Andreassi MG, Foffa I, Spadoni I, Vano E, Picano E (2010) Cumulative patient effective dose and acute radiation-induced chromosomal DNA damage in children with congenital heart disease. Heart 96(4):269–274CrossRefPubMed
21.
Zurück zum Zitat Lee T, Tsai IC, Fu YC, Jan SL, Wang CC, Chang Y, Chen MC (2006) Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility. Pediatr Radiol 36(12):1273–1282CrossRefPubMed Lee T, Tsai IC, Fu YC, Jan SL, Wang CC, Chang Y, Chen MC (2006) Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility. Pediatr Radiol 36(12):1273–1282CrossRefPubMed
Metadaten
Titel
Image quality and radiation dose of two prospective ECG-triggered protocols using 128-slice dual-source CT angiography in infants with congenital heart disease
verfasst von
Baojin Chen
Shuo Zhao
Yang Gao
Zhaoping Cheng
Yanhua Duan
Pritam Das
Ximing Wang
Publikationsdatum
17.01.2019
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 5/2019
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-018-01526-0

Weitere Artikel der Ausgabe 5/2019

The International Journal of Cardiovascular Imaging 5/2019 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.