Skip to main content
Erschienen in: BMC Musculoskeletal Disorders 1/2015

Open Access 01.12.2015 | Research article

Imaging methods for quantifying glenoid and Hill-Sachs bone loss in traumatic instability of the shoulder: a scoping review

verfasst von: David J. Saliken, Troy D. Bornes, Martin J. Bouliane, David M. Sheps, Lauren A. Beaupre

Erschienen in: BMC Musculoskeletal Disorders | Ausgabe 1/2015

Abstract

Background

Glenohumeral instability is a common problem following traumatic anterior shoulder dislocation. Two major risk factors of recurrent instability are glenoid and Hill-Sachs bone loss. Higher failure rates of arthroscopic Bankart repairs are associated with larger degrees of bone loss; therefore it is important to accurately and reliably quantify glenohumeral bone loss pre-operatively. This may be done with radiography, CT, or MRI; however no gold standard modality or method has been determined. A scoping review of the literature was performed to identify imaging methods for quantifying glenohumeral bone loss.

Methods

The scoping review was systematic in approach using a comprehensive search strategy and standardized study selection and evaluation. MEDLINE, EMBASE, Scopus, and Web of Science were searched. Initial selection included articles from January 2000 until July 2013, and was based on the review of titles and abstracts. Articles were carried forward if either reviewer thought that the study was appropriate. Final study selection was based on full text review based on pre-specified criteria. Consensus was reached for final article inclusion through discussion amongst the investigators. One reviewer extracted data while a second reviewer independently assessed data extraction for discrepancies.

Results

Forty-one studies evaluating glenoid and/or Hill-Sachs bone loss were included: 32 studies evaluated glenoid bone loss while 11 studies evaluated humeral head bone loss. Radiography was useful as a screening tool but not to quantify glenoid bone loss. CT was most accurate but necessitates radiation exposure. The Pico Method and Glenoid Index method were the most accurate and reliable methods for quantifying glenoid bone loss, particularly when using three-dimensional CT (3DCT). Radiography and CT have been used to quantify Hill-Sachs bone loss, but have not been studied as extensively as glenoid bone loss.

Conclusions

Radiography can be used for screening patients for significant glenoid bone loss. CT imaging, using the Glenoid Index or Pico Method, has good evidence for accurate quantification of glenoid bone loss. There is limited evidence to guide imaging of Hill-Sachs bone loss. As a consensus has not been reached, further study will help to clarify the best imaging modality and method for quantifying glenohumeral bone loss.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​s12891-015-0607-1) contains supplementary material, which is available to authorized users.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

DJS, TB, MB, DMS, LB contributed to study concept and design; DS and TB performed data acquisition; DJS, TB, MB, DMS, LB contributed to data analysis, interpretation and drafting and revising the manuscript. All authors read and approved the final draft of the manuscript.
Abkürzungen
2DCT
Two-dimensional computed tomography
3DCT
Three-dimensional computed tomography
BCSA
Best-fit circle surface area
d/R
Hill Sachs defect depth and humeral head radius
CT
Computed tomography
GHI
Glenohumeral instability
ICC
Intraclass correlation coefficient
MPR
Multiplanar reconstruction
MRA
Magnetic resonance arthrography
MRI
Magnetic resonance imaging
PE
Percentage error
VIBE
Volumetric interpolated breath-hold examination

Background

Glenohumeral instability (GHI) has been associated with a recurrence rate ranging from 30-90 % [13]. Currently, arthroscopic Bankart repair using modern suture anchor techniques have failure rates ranging from 4-17 % [46]. A number of risk factors have been proposed to predict recurrence of GHI following arthroscopic Bankart repair including: age, humeral head and glenoid bone loss, shoulder hyperlaxity, and contact activity [1, 710]. Glenoid bone loss occurs in up to 90 % of patients with recurrent GHI [11] and, on average, occurs nearly parallel to the long axis of the glenoid (03:01–03:20 on a clock face) [12, 13]. Burkhart et al. showed that significant glenoid bone loss, approximately 25-45 % of glenoid width loss, was associated with higher failure rates of arthroscopic Bankart repairs [14, 15]. The critical defect size for predicting failure of arthroscopic Bankart repairs has been explored biomechanically [1618]. Yamamoto et al. found that glenoid loss greater than 20 % glenoid length and 26 % of glenoid width, destabilized the shoulder [19]. The threshold of glenoid bone loss above which arthroscopic Bankart repairs may fail has generally been accepted as glenoid width loss ≥25 %, which is equivalent to ≥19 % of the glenoid length and ≥20 % of the surface area created by a best-fit circle on the inferior surface of the glenoid [1420]. Width loss of 25 % may be expressed as a millimeter defect, varying based on individual glenoid anatomy but is approximately 6-8 mm given that the average glenoid width at the level of the bare area is 24-26 mm [19, 21]. It is important to keep in mind how one calculates glenoid bone loss, as the threshold for surface area is different than for glenoid width.
Humeral head bone loss, also known as a Hill-Sachs lesion, occurs in up to 93 % of patients with recurrent GHI [22]. Hill-Sachs lesions are oriented in the axial plane approximately at 07:58+/−00:48 or at an angle of 239.1+/−24.3 ° from 12 o’clock [23]. In a biomechanical study, Kaar et al. showed that defects created at an orientation of 209 ° significantly decreased resistance to dislocation when they were greater than 5/8 the depth of the radius of the humeral head in the axial plane [24]. Sekiya et al. demonstrated that Hill-Sachs lesions created in a posterolateral orientation benefited from allograft transplantation when greater than 37.5 % of the humeral head diameter [25]. In a later cadaveric study, Sekiya et al. showed that defects of 25 % of the humeral head diameter in isolation did not increase risk of dislocation following a capsulolabral repair [26]. There is a relationship between recurrent dislocations and failure of arthroscopic Bankart repair with increasing size of the Hill-Sachs lesion, although an accepted threshold value for Hill-Sachs bone loss has not yet been determined [9, 27, 28]. Hill-Sachs bone loss occurs simultaneously with glenoid bone loss in up to 62 % of GHI patients [29]. The way in which the glenoid and Hill-Sachs lesions interact and contribute to GHI is complex but does appear to be synergistic [30].
The degree of glenohumeral bone loss plays a role in surgical decision-making. The glenoid lesion may be treated successfully with an arthroscopic Bankart repair if it is smaller than the previously mentioned values. Larger glenoid bone lesions may require a bone augmentation procedure such as a Latarjet coracoid transfer or a J-graft procedure (bone graft harvested from iliac crest) [31]. A large Hill-Sachs defect can be addressed via a remplissage procedure (posterior capsulodesis and infraspinatus tenodesis), allograft, resurfacing arthroplasty, or rotational osteotomy. Ideally, the surgeon would be able to accurately quantify bone loss preoperatively to best ensure a successful post-operative outcome with the lowest rate of recurrent instability and the least amount of post-surgical morbidity.
Multiple imaging methods exist for quantifying glenoid and Hill-Sachs bone loss including radiography, computerized tomography (CT), and magnetic resonance imaging (MRI). Radiography is inexpensive and easy to obtain but may be less accurate in detecting the presence of bone lesions compared to CT. Radiographic methods have been proposed using both basic views (true AP, axillary) and special views (Bernageau profile) to measure glenoid and Hill-Sachs bone loss. CT is easy to obtain and accurate with respect to bony detail, but necessitates radiation exposure. MRI is expensive and more difficult to obtain in public health care systems but has no radiation exposure, and may provide information on associated soft tissue lesions involving the labrum, rotator cuff, and capsule. However, assessment of bone lesions may be inferior to that of CT. Two common methods of calculating glenoid bone loss using CT and MRI are width measurements such as the Griffiths Index (Fig. 1) and best-fit circle surface area measurements such as the Pico Method (Fig. 2) [32, 33]. These methods involve reformatting to subtract the humeral head and get an en face view of the glenoid. The inferior 2/3 of the glenoid approximates a true circle, the size of which can be estimated based on either the contralateral glenoid or intact posteroinferior margins of the injured glenoid [11, 34, 35]. Bone loss can then be expressed as the area lost from the circle or the anterior-to-posterior width loss. Determination for Hill-Sachs bone loss has included, among others, depth, width, and length measurements [3639].
The degree of glenohumeral bone loss affects the success of arthroscopic Bankart repair and, at present, there is no consensus on a gold standard imaging method or modality for the quantification of glenohumeral bone loss. We performed a scoping review of the literature to identify current published imaging methods for quantifying glenoid and humeral head bone loss in GHI and to evaluate if there was a gold standard method and modality supported by evidence.

Methods

Study design

A scoping review was performed to evaluate the literature based on established guidelines [40, 41]. Scoping reviews are designed to assess the extent of a body of literature and identify knowledge gaps. Although qualitative in nature, the review can be systematic in approach through a comprehensive search strategy and standardized study selection and evaluation, as in our study. Due to heterogeneity in the articles reviewed, no meta-analyses were performed in this study.

Selection criteria

Studies were included if the following conditions were met: (1) publication after the year 2000 (following a preliminary review of the literature, the majority of relevant imaging methods were published after this time point; publications prior to 2000 are included in our introduction and discussion when historically relevant); (2) use of human or cadaveric human subjects; (3) evaluation of imaging methods including radiography, CT, and/or MRI; and (4) quantification of glenoid or Hill-Sachs bone loss using these imaging modalities. Criteria for exclusion were: (1) non-English language; and (2) publication in the form of an abstract, letter, or review article.

Search strategies

MEDLINE, EMBASE, Scopus, and Web of Science were searched from January 2000 until July 2013. A search algorithm was created with the guidance of a medical librarian (see Additional file 1).

Study selection

Article selection was performed over two rounds, by two orthopaedic surgery residents with the assistance of two upper extremity fellowship-trained orthopaedic surgeons. During the first round, selection was based on the review of titles and abstracts. To be as inclusive as possible, an article was carried forward to the next stage if either reviewer thought that the study was appropriate. Final study selection was based on full text review using the aforementioned inclusion and exclusion criteria. Duplicate studies were kept until the final article selection. Consensus was reached for final article inclusion through discussion amongst the investigators.

Data extraction

One reviewer extracted study design, imaging modality evaluated, patient characteristics, quantification method used, and findings. A second reviewer independently assessed data extraction for any discrepancies. When provided by the authors, the reliability, accuracy, sensitivity, and specificity are presented in the results section with accompanying tables.

Results

Article selection

Initial literature search retrieved 4536 total articles: 1462 from MEDLINE, 1560 from EMBASE, 827 from Scopus, and 687 from Web of Science (Fig. 3). After the initial review of titles and abstracts, 212 articles were retained. Following review of the full text, 114 articles remained. After the removal of duplicates, 41 articles were included.

Article summary

Tables 1, 2, 3, 4, 5 and 6 summarize the selected articles. We retained 11 articles focusing on Hill-Sachs bone loss, 32 for glenoid bone loss, and 2 articles evaluated both. There were a significantly higher number of articles evaluating CT imaging (38) compared to radiography (11) and MRI (10). For glenoid bone loss, radiography was evaluated in 7 studies [18, 4247], MRI in 8 studies [21, 42, 44, 4853], and CT in 32 studies [11, 18, 20, 21, 32, 33, 35, 4251, 5469]. For Hill-Sachs bone loss, radiography was evaluated in 5 studies [3739, 46, 47], MRI in 2 studies [70, 71], and CT in 5 studies [23, 36, 7274].
Table 1
Studies Assessing Glenoid Bone Loss with Radiography
Study
Modality
Details
Quantification Technique
Findings
Charousset et al. [47]: Retrospective case series
Radiography; 2DCT
31 patients
True AP radiography:
Loss of sclerotic line (ICC):
Assessment:
Loss of sclerotic line
Inter-observer 0.44-0.47
True AP view; 2DCT arthrogram; 3 observers measured twice
CT:
Intra-observer 0.66-0.93
Outcome:
Griffith Index (Fig. 1); best-fit circle width loss (Fig. 10)
Griffiths Index (ICC):
Reliability
Inter-observer 0.68-0.71
  
Intra-observer 0.78-0.90
  
Best-fit circle width loss (ICC):
  
Inter-observer 0.74
  
Intra-observer 0.90-0.95
Itoi et al. [18]: Cadaveric study
Radiography; 2DCT
12 cadavers
Radiography:
21 % glenoid length defect:
Assessment:
West Point & axillary views
18.6 % on West Point view 2.3 % on axillary view
45 ° angle defects created at 0, 9, 21, 34, & 46 % of glenoid length; radiography at each cut; 1 observer measured twice
CT:
50 % loss of width on CT
Outcome:
Width of the inferior ¼ of the glenoid measured in a single axial slice
 
Correlation, reliability
 
Correlation coefficients:
  
0.905-0.993
  
Coefficients of variance:
  
0.5-3.6 %
Jankauskas et al. [45]: Retrospective case–control study
Radiography; 2DCT
86 patients
Superoinferior length of bone defect
Detecting bone lesion:
Assessment:
 
Sensitivity 54-65 %
True AP radiography; 2 observers on radiography; 1 observer on CT
 
Specificity 100 %
Outcome:
 
Inter-rater reliability: kappa = 0.88
Reliability; sensitivity; specificity
 
Radiography vs. CT:
  
9 shoulders with mean 8.2 ± 3.5 mm glenoid bone loss on CT were missed on radiography
Sommaire et al. [46]: Retrospective cohort study
Radiography; 2DCT
77 patients
Radiography:
Radiographic D1/D2 ratio (p = 0.003):
Assessment:
Bernageau view of both shoulders to calculate D1/D2 ratio (Fig. 4)
4.2 % patients without recurrence
Pre-operative Bernageau radiographs & 2DCT of unilateral shoulder before arthroscopic Bankart repair; 1 observer measured once
CT:
 
Outcome:
Gerber‘s X index (Fig. 7)
5.1 % in patients with recurrence
  
CT:
  
Recurrence Rate (p = 0.004):
  
Gerber X index < 40 % =20 %
Need for revision correlated with imaging
 
Gerber X Index >40 % =12.7 %
  
Note: Reliability not assessed
Murachovsky et al. [43]: Prospective case–control study
Radiography; 3DCT
10 patients; 50 healthy subjects
Radiography:
Reliability:
Assessment:
Bernageau view (D1/D2) ratio (Fig. 4)
Intra-observer ICC 0.897-0.965
Bilateral radiography (all subjects) & CT (instability subjects); 1 radiologist measured CT; 3 orthopaedic surgeons measured 3 times each
3DCT:
Inter-observer ICC 0.76-0.81
Outcome:
Glenoid AP width measured bilaterally to calculate % bone loss
Difference between radiography & CT non-significant (2.28 %)
Reliability
  
List of Abbreviations: ICC intraclass correlation coefficient; PE percent error
Table 2
Studies Assessing Glenoid Surface Area Loss with CT and MRI
Study
Modality
Details
Quantification Technique
Findings
Barchilon et al. [20]: Prospective case series
2DCT; 3DCT
13 patients
Best-fit circle surface area:
Method 1 with method 2:
Assessment:
Approximation based on intact posteroinferior edge of ipsilateral glenoid
R2 = 0.91
2DCT & 3DCT using 3 methods
(1) Software directly measured area of circle and area of missing area using 2DCT (gold standard)
Method 1 with method 3:
Outcome:
(2) Mathematical formula to calculate % surface area loss using 2DCT based on circle radius & defect depth with software
R2 = 0.60
Intra-method comparison
(3) Manually measured defect depth & circle radius using 3DCT & femoral head gauge; formula to calculate % surface area
Note: BCSA methods can be applied without computer software
Hantes et al. [65]: Cadaveric study
3DCT
14 cadavers
Best-fit circle surface area:
Reliability:
Assessment:
Sugaya Method
Coefficient of variation 2.2-2.5 %
CT scan following 3 serial osteotomy’s; 1 observer measured 5 times for 2 glenoids
  
Outcome:
  
Reliability
  
Huijsmans et al. [21]: Cadaveric study
3DCT; MRI
14 cadavers
Best-fit circle surface area:
Difference with digital picture:
Assessment:
Circle approximated based on ipsilateral glenoid; software used
CT −0.81 % to −1.21 %
Digital picture, CT, & MRI before/after osteotomy (random size) on anterior glenoid; 2 observers measured 3 times
 
MRI 0.61 % to 0.74 % (non-significant)
Outcome:
 
CT:
Reliability
 
Inter-observer r2 = 0.94
  
Intra-observer r2 = 0.97 (observer 1) and 0.90 (observer 2)
  
MRI:
  
Inter-observer r2 = 0.87
  
Intra-observer r2 = 0.93 (observer 1) and r2 = 0.92 (observer 2)
  
Digital image:
  
Inter-observer r2 = 0.97
Lee et al. [52]: Prospective case series
2DCT; MRI
65 patients
1) Best-fit circle surface area (Pico method)
Inter-observer ICC:
Assessment:
2) Best-fit circle width method
0.95 for best-fit circle width
CT (bilateral) & MRI followed by arthroscopy; 1 observer measured CT once; 3 observers measured MRI once; 1 observer measured MRI 3 times
Arthroscopy with bare-area technique (used as gold standard)
0.90 for area (Pico method)
Outcome:
 
Intra-observer reliability ICC:
Reliability
 
0.98 width
  
0.97 area
  
Correlation:
  
CT & MRI 0.83
  
CT & arthroscopy 0.91
  
MRI & arthroscopy 0.84
Magarelli et al. [32]: Prospective case series
2DCT
40 patients
Best-fit circle surface area method:
Intra-observer reliability:
Assessment:
Pico method based on contralateral glenoid
ICC 0.94
Bilateral CT; 1 observer measured 3 times; 1observer measured once
 
SEM 1.1 %.
Outcome:
 
Inter-observer reliability:
Reliability
 
ICC 0.90
  
SEM 1.0 %.
  
Note: No comparison to other methods
Magarelli et al. [57]: Prospective cohort study
2DCT; 3DCT
100 patients
Best-fit circle surface area:
Mean difference:
Assessment:
Pico method based on contralateral glenoid
0.62 %+/−1.96 %
Bilateral CT; 2 observers measured once
 
Note: No reliability measurement
Outcome:
  
Agreement between 2D & 3D CT
  
Nofsinger et al. [35]: Retrospective case series
3DCT
23 patients
Best-fit circle surface area:
Normal shoulder:
Assessment:
Anatomic Glenoid Index: circle matched to postero-inferior glenoid of contralateral glenoid; software measured area of circle
Circle fit true glenoid closely −100.5 %, SD 2.2 %.
Bilateral pre-op CT followed by surgical repair (12 Bankart, 11
 
Mean AGI for Bankart group:
Latarjet); 3 blinded observers measured once
(A1); circle manually adjusted to fit defect & area again calculated by software (A2); area loss = A2/A1 x 100
92.1 %+/−5.2 %
Outcome:
 
Mean AGI for Latarjet:
Surgical decision based on size >25 % at arthroscopy; reliability
 
89.6 %+/−4.7 %
  
Inter-rater reliability (Pearson correlation coefficient):
  
0.60-0.84
  
Note: Did not have the power to separate the two surgical groups
Park et al. [60]: Retrospective case series
2DCTA
30 patients
Best-fit circle surface area:
Intra-observer reliability:
Assessment:
Pico method based on ipsilateral glenoid
ICC 0.96-1.00;
CTA taken pre-op, at 3 months, and 1 year after bony Bankart repair; 1 observer measured 6 times
 
Positive relationship between number of dislocations & defect size
Outcome:
  
Reliability
  
Sugaya et al. [11]: Case–control study
3DCT
100 patients, 10 healthy volunteers
Best-fit circle surface:
Normal glenoid did not differ significantly from contralateral glenoid; inferior portion of glenoid approximates a true circle; did not compare measurements to arthroscopic measurements; no reliability measurements
Assessment:
Sugaya Method with bone fragment manually outlined
Note: Technique would not work in case of attritional bone loss without a Bankart fragment
Bilateral CT; defects categorized as: small (<5 %), medium (5-20 %), or large (>20 %); patients also had arthroscopy: 1 observer measured once
  
Outcome:
  
  
Comparison to normal glenoid
  
List of Abbreviations: ICC: intraclass correlation coefficient; PE: percent error; SEM: standard error of measurement; R2: coefficient of determination; AGI: anatomic glenoid index
Table 3
Studies Assessing Glenoid Width Loss with CT and MRI
Study
Modality
Details
Quantification Technique
Findings
Charousset et al. [47]: Retrospective case series
Radiography; 2DCT
31 patients
True AP radiography:
Loss of sclerotic line:
Assessment:
loss of sclerotic line
Inter-observer ICC 0.44-0.47
True AP radiography & 2DCT arthrogram; 3 observers measured twice
CT:
Intra-observer ICC 0.66-0.93
Outcome:
Griffiths Index (Fig. 1) & best-fit circle width loss (Fig. 10)
Griffiths Index:
Reliability
 
Inter-observer ICC 0.68-0.71
  
Intra-observer ICC 0.78-0.9
  
Best-Fit Circle Width Loss:
  
Inter-observer ICC 0.74
  
Intra-observer ICC 0.9-0.95;
Chuang et al. [68]: Retrospective case series
3DCT
25 patients
CT:
Glenoid Index correctly categorized 96 % of patients
Assessment:
Glenoid Index (Fig. 5)
Glenoid Index:
Bilateral 3DCT followed by diagnostic arthroscopy: >25 % glenoid width loss (Latarjet); <25 % glenoid width loss (arthroscopic Bankart)
Arthroscopy:
Latarjet group: mean 0.668
Outcome:
Bare area method
Bankart group: mean 0.914
  
Ability to predict type of surgery offered
  
Griffith et al. [33]: Case–control study
2DCT; 3DCT
40 patients (46 shoulders); 10 healthy subjects
Measurements:
Healthy subjects:
Assessment:
Width & cross-sectional surface area on axial slice; length; width; length:width ratio; glenoid surface area by point tracing; flattening of anterior glenoid curvature
No significant difference in side-side measurements
Bilateral CT;1 observer measured once
 
Instability Subjects:
Outcome:
 
Width (3 mm difference; 10.8 % width loss); length:width ratio, & cross-sectional area significantly different side-to-side
Glenoid comparison with healthy subjects on en face glenoid view
  
Griffith et al. [58]: Prospective case series
2DCT
50 patients
Width Measurement:
CT correlation with arthroscopy:
Assessment:
Griffiths Index (Fig. 1)
Pearson Correlation Coefficient r = 0.79
Bilateral CT followed by arthroscopy; compared to measurements made during arthroscopy (bare spot method); 1 observer measured once
  
Outcome:
 
Sensitivity 92.7 %
Correlation, PPV, NPV
 
Specificity 77.8 %
  
PPV 95 %; NPV 70 %.
  
Mean bone loss(p = 0.17):
  
CT 11.0 %+/−8.1 %
  
Arthroscopy 12.3 %+/−8.8 %
Griffith et al. [62]: Case–control study
2DCT
218 patients; 56 healthy subjects
Width measurement:
Griffith Index (Fig. 1)
Normal side-to-side glenoid width difference small (0.46 mm);
Assessment:
Note: Glenoid bone loss not calculated on bilateral subjects
Reliability:
Bilateral CT; 1 observer measured all subjects; 2 observers measured 40 patients twice
 
Inter-observer reliability ICC 0.91
Outcome:
 
Intra-observer reliability ICC 0.95
Reliability
  
Gyftopoulos et al. [48]: Cadaveric study
2DCT; 3DCT; MRI
18 cadavers
Width method:
Intra-observer concordance correlation coefficient (CCC):
Assessment:
Best-fit circle width method based on ipsilateral glenoid
2DCT 0.95
Defects created along anterior and antero-inferior glenoid; 3 observers measured defect size once; 1 observer re-measured at 4 weeks; gold standard was digital photograph
 
3DCT 0.95
Outcome:
 
MRI 0.95
Reliability, PE
 
Inter-observer CCC:
  
2DCT −0.28-0.88
  
3DCT 0.82-0.93
  
MRI 0.70-0.96
  
Percent error:
  
2DCT 2.22-17.11 %
  
3DCT 2.17-3.50 %
  
MRI 2.06-5.94 %
Lee et al. [52]: Prospective cohort study
2DCT; MRI
65 patients
1) Best-fit circle surface area:
Inter-observer reliability (ICC)
Assessment:
Pico Method
Best-fit circle width R = 0.95
CT (bilateral) & MRI followed by arthroscopy; 1 observer measured CT once; 3 observers measured MRI once; 1 observer measured MRI 3 times;arthroscopy was gold standard using bare-area technique
2) Best-fit circle width method:
Area (Pico method) R = 0.90
Outcome:
Based on contralateral glenoid
Intra-observer reliability:
Reliability, correlation
 
Width R = 0.98, area R = 0.97
  
Correlation:
  
CT-MRI r = 0.83
  
CT-arthroscopy r = 0.91
  
MRI-arthroscopy r = 0.84
Moroder et al. [50]: Retrospective case series
3DCT, MRI
48 patients
Width method:
CT for glenoid lesion:
Assessment:
Best-fit circle width method
Sensitivity 100 %
Pre-op CT & MRI evaluated after failed instability surgery; findings at initial operation were comparators; 1 observer measured significant glenoid defects (>20 % of width)
 
Specificity 100 %
Outcome:
 
MRI for significant lesion:
Sensitivity 35.3 %
Sensitivity, specificity
 
Specificity 100 %
  
CT would have misled treatment in only 4.2 %
Tian et al. [51]: Prospective cohort study
2DCT; MRA
41 patients; 15 control patients
Width method:
No significant size measurements between MRA (10.48 %+/−8.71 %) & CT (10.96 %+/−9.0 %; p = 0.288).
Assessment:
Best-fit circle width method based on ipsilateral glenoid (Fig. 10)
Correlation between methods:
CT & MRA; 2 observers measured once
 
Pearson correlation coefficient r = 0.921; SD 3.3 %
Outcomes:
  
Correlation
  
List of Abbreviations: ICC: intraclass correlation coefficient; PE: percent error; PPV: positive predictive value; NPV: negative predictive value
Table 4
Studies Directly Comparing Imaging Methods for Assessing Glenoid Bone Loss
Study
Modality
Details
Quantification Technique
Findings
Bishop et al. [42]: Cadaveric study
Radiography; 2DCT; 3DCT; MRI
7 cadavers
Observers measured bone loss using his/her usual approach (Methods not specified)
Overall agreement with gold standard (kappa score):
Assessment:
 
3DCT 0.5
Serial imaging of shoulder after osteotomies of 0 %, <12 %, 12-25 %, 25-40 %; manually measured glenoid width through bare area using a digital caliper (gold standard); 12 observers measured twice
 
CT 0.4
Outcome:
 
MRI 0.28
Reliability
 
Radiography 0.15
  
Intra-observer reliability (kappa):
  
3DCT 0.59
  
CT 0.64
  
MRI 0.51
  
Radiography 0.45
  
Note: 3DCT highest agreement & 2nd highest intra-observer reliability; radiography lowest agreement & reliability
Bois et al. [63]: Laboratory study
2DCT; 3DCT
Sawbones:1 model for anterior defect; 1 model for anteroinferior defect
2DCT & 3DCT:
2D CT methods (ICC, PE):
Assessment:
Indicators: linear width/length (W/L) ratio; defect length; quantifiers: glenoid index (injured glenoid inferior circle diameter relative to uninjured glenoid diameter)
Defect length: 0.81, 7.68
Osteotomies made at 0, 15 %, and 30 % of inferior glenoid circle diameter; gold standard measurement (3D laser scanner of model); 6 observers measured all 7 techniques
3DCT:
W/L ratio: 0.50, −16.34
Outcome:
Quantifiers: linear ratio (d/R; d = radius to defect, R = circle radius); Pico method (3 variations):
Glenoid index, 0.3, −4.13
Reliability, PE
(1) Original circle method
3D CT (ICC, PE):
 
(2) Based on contralateral normal glenoid circle with 3 points of reference
Defect length: 0.90, 0.29
 
(3) Based on remaining intact glenoid cortex
W/L ratio: 0.88, −2.41
  
Glenoid index: 0.69, 0.01 (0.85, 3.39 with other software platform)
  
Linear ratio: 0.97, 29.9
  
Pico (1): 0.98, 4.93
  
Pico (2): 0.84, 7.32
  
Pico (3): 0.86, 12.14
  
Note: Pico method (1) based on the contralateral, intact glenoid and Glenoid Index on 3DCT were most reliable & accurate; Glenoid Index on 2DCT was deemed invalid
Rerko et al. [44]: Cadaveric study
Radiography; 2DCT; 3DCT; MRI
7 cadavers
Observers measured bone loss using his/her usual approach (Methods not specified)
Accuracy (PE):
Assessment:
 
3DCT −3.3 %+/−6.6 %
Serial imaging of shoulder with osteotomies grouped as 0 %,<12 %, 12, 25 %, 25-40 %; gold standard defined as glenoid width using digital caliper; 2 radiologists & 2 orthopaedic surgeons measured twice
 
2DCT −3.7 %+/−8.0 %
Outcome:
 
MRI −2.75 %+/−10.6 %
PE, reliability
 
Radiography −6.9 % +/− 13.1 %
  
Intra-observer reliability (ICC):
  
3DCT 0.947
  
2DCT 0.927
  
MRI 0.837
  
Radiography 0.726
  
Inter-observer reliability (ICC):
  
3DCT 0.87-0.93
  
2DCT 0.82-0.89
  
MRI 0.38-0.85
  
Radiography 0.12-0.53
List of Abbreviations: ICC: intraclass correlation coefficient; PE: percent error
Table 5
Other Methods for Assessing Glenoid Bone Loss
Study
Modality
Details
Quantification Technique
Findings
De Filippo et al. [66]: Cadaveric study
2DCT
10 cadavers
De Filipo Method: Fig. 6
Curved MPR CT:
Assessment:
Note: Curved MPR assessed curved structures very accurate
PE 1.03 %; inter-observer reliability (Cronbach alpha) 0.995
2 had anteroinferior defects created; 1 re-measured at 3 months; measured glenoid bone area on flat MPR & curved MPR of all 10 cadavers; laser scanner used directly on cadavers as gold standard; 3 radiologists measure once
 
Intra-observer reliability (ICC) 0.998
Outcome:
 
Flat MPR CT:
PE, reliability
 
PE 16.99 %
  
Inter-observer reliability (Cronbach alpha) 0.995
  
Note: Authors conclude curved gives more accurate glenoid contour
Diederichs et al. [59]: Cadaveric study
3DCT
5 cadavers; 30 patients with no glenoid injury
Manually traced out border of glenoid; volume and surface area calculated with measurements made manually (to calculate volume, depth was assumed to be 10 mm)
Coefficient of variation:
Assessment:
 
Width 1.7 %
Glenoid width, height, surface area, & volume; osteotomy created on one cadaveric glenoid; compared to contralateral for calculation; 1 investigator measured study group; another measured the controls
 
Volume 1.3 %
Outcome:
  
Coefficient of varaition
  
Dumont et al. [49]: Technique description
CT; MRI
Authors describe a new method to calculate surface area loss
Best-fit circle to inferior glenoid; measured angle (alpha) from center of circle between superior and inferior edges of lesion; converted measured angle to percentage area loss = [(alpha-sinalpha)/2π] x 100
No assessment of reliability or comparison to other methods
Note: This method avoids issues with defect orientation and is simple to apply without complicated software
Tauber et al. [56]; Retrospective case series
CT
10 patients with associated glenoid fracture (>21 % glenoid length)
Fit circle to outer glenoid, measured glenoid length at 45° angle (A), measured length to defect (B); calculated bone loss as: (A x 0.965 – B)/A x 100
Inter-observer reliability:
Assessment:
 
ICC = 0.81
2 examiners measured once
 
Average width loss 26.2 %
Outcome:
  
Reliability
  
Van Den Bogaert et al. [69]: Cadaveric study
2DCT
20 cadavers
Glenohumeral index:
Glenohumeral Index Compared to Gold Standard:
Assessment:
Maximal AP diameter of humeral head / maximal AP diameter of glenoid (axial images)
Non-significant difference
Diameter measured with a digital caliper in vitro (gold standard) followed by CT quantification; 3 observers measured once
  
Outcome:
  
Direct comparison
  
List of Abbreviations: ICC: intraclass correlation coefficient
Table 6
Studies Assessing Hill-Sachs Bone Loss with Radiography, CT and MRI
Citation
Method
Details
Quantification Method
Findings
Charousset et al. [47]: Retrospective case series
Radiography
26 patients
Quantitative assessment:
P/R ratio reliability:
Assessment:
P/R ratio on true AP radiography in internal rotation (Fig. 10)
Inter-observer ICC 0.81-0.92
3 observers measured twice
Qualitative assessment:
Intra-observer ICC 0.72-0.97
Outcome:
True AP radiograph in external rotation (present or absent lesion)
Qualitative assessment reliability:
Reliability
 
Inter-observer ICC 0–0.30
  
Intra-observer ICC 0.06-0.92
  
Note: Simple patient positioning and reliable
Ito et al. [38]: Retrospective case series
Radiography
27 patients (30 shoulders)
Width and depth of Hill-Sachs lesion measured:
Width difference (p > 0.05) :
Assessment:
Supine position; arm 135 ° flexion, 15 ° internal rotation; radiography beam perpendicular
Dislocation group 13.4 mm+/−2.5 mm
Divided into 2 groups: dislocation (11) and dislocation with recurrent subluxation (19); 1 observer measured once
Note: Patient positioning may be cumbersome and difficult to replicate in a clinical setting
With subluxation group 13.8+/−3.5 mm
Outcome:
 
Depth difference (p < 0.05):
Width difference
 
Dislocation group 3.9+/−0.9 mm
  
With subluxation group 2.1+/−1.0 mm
  
Note: Deeper lesions associated with subjective joint laxity but not number of dislocations
Kralinger et al. [39]: Retrospective cohort study
Radiography
166 patients
Hill-Sachs Quotient:
Recurrence rate associated with Hill-Sachs Quotient:
Assessment:
Bernageau view and AP view at 60 ° internal rotation (Fig. 8)
Grade I 23.3 %
1 observer measured once
 
Grade II 16.2 %
Outcome:
 
Grade III 66.7 %
Recurrence rate
  
Sommaire et al. [46]: Retrospective cohort study
Radiography
77 patients
d/R ratio:
Risk of recurrence (p = 0.016):
Assessment:
True AP radiograph in internal rotation (similar to Charousset et al. [2010]; Fig. 9)
9.6 % in d/R ratio <20 %
Final clinical outcome after arthroscopic Bankart repair and imaging; 1 observer measured once
 
40 % in d/R ratio >20 %
Outcome:
 
Note: d/R ratio predictive of failure of arthroscopic Bankart repair
Need for revision repair
Hardy et al. [37]: Retrospective cohort study
Radiography; 2DCT
59 patients
Radiograph 45 ° internal rotation view:
d/R ratio (p < 0.01):
Assessment:
Depth of defect/radius of humerus (d/R) ratio (similar to Charousset et al. [2010])
Good/excellent group: 16.2 %
  
After arthroscopic stabilization divided into 2 groups based on Duplay clinical functional score: good/excellent (38) fair/poor (21); 1 observer measured all patients once; 10 observers measured 10 patients
CT:
Poor/fair group: 21.3 %
Outcome:
Humeral head radius (best-fit circle to circumference); defect width; defect depth (from edge of circle); defect length (amount of CT slices with the defect); lateralization angle (compared to AP line through center of head)
Mean volume of lesion (p < 0.001):
Correlation of clinical score with radiographic findings; surgical failure rate
Note: Radiographic technique easily obtained
Good/excellent group: 640 mm3
  
Poor/fair group: 2160 mm3
  
Surgical failure rate:
  
d/R >15 %: 56 %
  
d/R < 15 %: 16 %
  
Presence of lesion, depth, lateralization angle, lesion, and humeral head volume ratio all non-significant between groups
  
Reliability :
  
Inter-observer reliability for depth and radius measurements non-significant
Kodali et al. [72]: Laboratory study
2DCT
6 anatomic bone substitute models
Circle fit to humeral head:
Inter-observer reliability ICC:
Assessment:
Width and depth measured on sagittal, axial, and coronal planes (similar to Saito et al. (2009)
Depth - 0.879
Circular humeral head defects created; 2DCT width-depth measurements made in 3 planes and compared to the defect sizes measured by a 3D laser scanner
 
Width 0.721
Outcome:
 
Accuracy (PE):
5 observers measured once
 
Width: sagittal 10.9+/−8.6 %, axial 10.5+/−4.4 %, coronal 15.9+/−8.6 %;
  
Depth: sagittal 12.7+/−10.0 %, axial 16.7+/−10.2 %,coronal 22.5+/−16.6 %
Saito et al. [12]: Retrospective case-controls study
2DCT
35 patients; 13 normal
Circle fit to the humeral head on axial slices:
Mean size of Hill-Sachs lesion:
Assessment:
Depth: greatest length of distance from floor of defect to edge of circle; width: measured between edges of defect
Depth 5.0+/−4.0 mm; width 22+/−6 mm
1 observer measured 3 times
 
Intra-observer reliability:
Outcome:
 
Pearson correlation coefficient: 0.954-0.998
Reliability
 
Coefficient of variation: 0–7.4 %.
Cho et al. [36]: Prospective cohort study
3DCT
104 patients (107 shoulders)
Fit circle to articular surface of humeral head:
Inter-observer reliability:
Assessment:
Axial and coronal planes: width and depth measured on axial and coronal slice where lesion was largest
ICC 0.629-0.992
evaluated size, orientation, & location as means to predict engagement; engagement defined arthroscopically; 1 observer measured 27 randomly selected shoulders 3 times; 2nd observer measured once
 
Intra-observer reliability:
Outcome:
 
ICC 0.845-0.998
Reliability, size of Hill-Sachs lesion relationship to engaging lesions
 
Size of Hill-Sachs lesion (axial):
  
Engaging group width 52 % & depth 14 %
  
Non-engaging group width 40 % & depth 10 % (both p <0.001)
  
Size of Hill-Sachs lesion (coronal):
  
Engaging group width 42 % & depth 13 %
  
Non-engaging group width 31 %, & depth 11 % (p = 0.012 & 0.007 respectively).
  
Note: Orientation of Hill-Sachs angle significantly higher in engaging lesions
Kawasaki et al. [73]: Modeling
3DCT
Evaluated 7 CT scans of bilateral shoulders
Created 3D contour; mirrored the normal shoulder and overlap contours; computer measured defect difference
Proposed a method to calculate humeral head bone loss
Kirkley et al. [70]: Prospective case series
MRI
16 patients
Hill-Sachs lesions were categorized as small (<1 cm) or large (>1 cm);
Presence vs. absence of Hill-Sachs lesion:
Assessment:
Note: Did not clarify slice or dimensions measured to determine Hill-Sachs lesion size
Kappa = 1
MRI followed by arthroscopic evaluation; 2 observers measured once
 
Distinguishing small from large lesion:
Kappa = 0.44
Outcome:
 
Not able to accurately quantify size
Reliability
  
Salomonsson et al. [71]: Prospective cohort study
MRI
51 patients
Hill-Sachs depth:
Size of Hill-Sachs lesion:
Assessment:
Measured on axial slice at largest point
Stable group 5 mm; unstable group 3 mm (non-significant)
MRI immediately and clinical follow-up to 105 months; divided into stable and unstable (recurrent instability); 2 observers measured once
  
Outcome:
  
Size of Hill-Sachs lesion correlation with recurrent instability
  
List of Abbreviations: ICC: intraclass correlation coefficient; PE: percent error

Glenoid imaging

Radiography

Routine radiographic views (true AP and axillary) were found to have lower accuracy and reliability in calculating glenoid bone loss (Table 1) [18, 42, 44, 45, 47]. Special radiographic views on the other hand, in particular the Bernageau profile view (Fig. 4), had better accuracy and reliability scores [18, 43, 46]. The Bernageau profile had an intra-observer intraclass correlation coefficient (ICC) 0.897-0.965 and inter-observer ICC 0.76-0.81 compared to a true AP radiograph with an intra-observer ICC 0.66-0.93 and inter-observer ICC 0.44-0.47 [43, 47]. Sommaire et al. demonstrated failure of Bankart repair when the width loss was 5.3 % compared to no failure with width loss 4.2 % using the Bernageau view (p = 0.003), although no clinically relevant threshold was defined [46]. A true AP radiograph was found to be specific (100 %) but not sensitive (54-65 %) for detecting a large glenoid bone lesion [45].

CT and MRI

Surface area loss measurements

The surface area loss methods vary in the manner to which a circle is approximated to the inferior glenoid - based on either contralateral glenoid or intact posteroinferior margins of injured glenoid - but will be grouped together in this review as best-fit circle surface area methods (Fig. 10) (BCSA). The Pico Method (Fig. 2) is a BCSA based on the contralateral glenoid described by Baudi et al. [75]. The Pico Method has demonstrated good inter-observer (ICC 0.90) and intra-observer (ICC 0.94, 0.96-1.0) reliability as well as a low coefficient of variation (2.2-2.5 %) [32, 60, 65]. Magarelli et al. (mean difference between two-dimensional CT [2DCT] and three-dimensional CT [3DCT] 0.62 %+/−1.96 %) showed the method could be applied accurately with both 2DCT and 3DCT [32]. The previous article used software to calculate the surface area lost, but Barchillon et al. demonstrated that a BCSA method similar to the Pico Method could be applied using 3DCT, a femoral head gauge, and applying a mathematical formula [20]. Milano et al. demonstrated that using the Pico Method, recurrent dislocation was associated with defects greater than 20 %. [55] Huijsmans et al. showed that a BCSA method could be used by MRI with similar accuracy to 3DCT [21]. Nofsinger et al. used a method termed the Anatomic Glenoid Index (see Table 2 for description) in an attempt to retrospectively predict which surgical procedure an instability patient would receive but were unable to separate the two groups with their method [35].

Width loss measurements

Griffith et al. created the Griffith Index using bilateral shoulder CT scans (Fig. 1) as one of the first width loss techniques and it has been found to be reliable and accurate [33, 47, 58]. A method similar to the Griffith Index, termed the Glenoid Index (Fig. 5) was shown to accurately predict if a patient would require a Latarjet procedure 96 % of the time [68]. Other width loss measurement methods have measured width loss from a circle approximated to the inferior glenoid (based on either contralateral or ipsilateral glenoid) and have been found to have good reliability and accuracy (Table 3) [47, 48, 50, 52]. Evidence is conflicting with respect to whether width loss measurements can be applied to MRI. Tian et al. suggested volumetric interpolated breath-hold examination (VIBE) magnetic resonance arthrography (MRA) was as accurate as 2DCT and Lee et al. found a correlation between 2DCT and MRI of r = 0.83 and the difference in accuracy was 1.3 % for width loss measurements [51, 52]. Moroder et al. found that MRI (35 % sensitive, 100 % specific) was not as sensitive as 3DCT (100 % sensitive, 100 % specific) for detecting a significant bone lesion [50]. Gyftopoulous et al. found 3DCT was more accurate than 2DCT and MRI (percent error 3DCT 2.17-3.5 %, 2DCT 2.22-17.1 %, MRI 2.06-5.94 %) although the difference was not significant and they concluded that MRI could accurately measure glenoid bone loss [48].

Comparative studies

A few studies directly compared imaging modalities and methods (Table 4). Bishop et al. found 3DCT had the highest accuracy (agreement kappa 0.5) and second highest intra-observer reliability (intra-observer kappa 0.59) while radiography (agreement kappa 0.15, intra-observer kappa 0.45) had the lowest in a comparison of radiography, 2DCT, 3DCT, and MRI [42]. Rerko et al. also found that 3DCT was the most accurate (percent error [PE] -3.3 % +/− 6.6 %) and reliable (inter-observer ICC 0.87-0.93) method compared to radiography (PE −6.9 %; ICC 0.12-0.53), 2DCT (PE −3.7 %; ICC 0.82-0.89), and MRI (PE −2.75 %; ICC 0.38-0.85) [44]. Bois et al. evaluated 7 measurement techniques using 2DCT and 3DCT and found that the Pico Method based on the contralateral, intact glenoid (inter-observer ICC 0.84; PE 7.32) and Glenoid Index using 3DCT (ICC 0.69; PE 0.01) were the most reliable and accurate methods [63].

Other glenoid bone loss methods

Results are presented in Table 5. Dumont et al. used an arc angle to determine percent surface area loss but have not tested the method clinically [49]. De Filipo et al. created a new technique using curved multiplanar reconstruction (MPR), a CT technique generally used for vascular studies for its ability to follow curved surfaces, and found it was more accurate than flat MPR in measuring surface area loss (Fig. 6) [66]. Diederichs et al. expressed bone loss in terms of volume using 3D computer software to mirror the contralateral normal glenoid and found good accuracy in a cadaveric study [59]. Sommaire et al. used Gerber’s Index and found that a threshold of 40 % bone loss was associated with recurrent instability (Fig. 7) [46].

Hill-Sachs imaging

Radiography
Results are presented in (Table 6). Ito et al. positioned patients supine with the shoulder in 135 ° flexion and 15 ° of internal rotation to obtain a view of the posterolateral notch and calculate depth and width of the Hill-Sachs lesion but reliability was not explored [38]. Kralinger et al. calculated a Hill-Sachs Quotient (Fig. 8) by measuring depth and width on a true AP radiograph with the arm in 60 ° internal rotation and length on a Bernageau profile [39]. Recurrence rate was noted to be higher with a larger quotient (Grade I 23.3 %; grade II 16.2 %; grade III 66.7 %) although the reliability and accuracy have not been tested.
A technique of creating a ratio using the Hill-Sachs defect depth and humeral head radius (d/R) on a true AP radiograph with the arm in internal rotation has been found to be reliable and clinically relevant (Fig. 9). Charousset et al. demonstrated inter- and intra-observer reliability ICC 0.81-0.92 and 0.72-0.97 respectively with this technique [47]. Sommaire et al. retrospectively found the recurrence rate of GHI was 40 % when d/R >20 % compared to 9.6 % when d/R <20 %, while Hardy et al. found arthroscopic stabilization failure rate was 56 % when d/R > 15 % compared to 16 % when d/R <15 % [37, 46].

CT and MRI

Hardy et al. measured the volume of the defect on axial slices using width, depth, and length and found a significantly larger defect volume in patients with lower Duplay functional scores but did not evaluate reliability [37]. Saito et al. and Cho et al. both measured defect depth and width on the axial slice where the lesion was largest [23, 36]. Saito et al. found intra-observer Pearson correlation coefficients of 0.954-0.998 using 2DCT. Cho et al. found inter- and intra-observer reliability ICC of 0.772-0.996 and 0.916-0.999 respectively for depth and width measurements on 2DCT. Cho et al. also showed that the size of engaging Hill-Sachs lesions were significantly larger than non-engaging lesions. Kodali et al. evaluated the reliability and accuracy of 2DCT with an anatomic model and showed inter-observer reliability ICC 0.721 and 0.879 for width and depth respectively. The accuracy was highest in axial slices but there was still a percent error of 13.6+/−8.4 % [72].
Two studies evaluated MRI for quantifying Hill-Sachs lesions. Salomonsson et al. measured the depth of the lesion but were not able to show a significant difference between stable and unstable shoulders that were treated non-operatively [71]. Kirkley et al. tested the agreement between MRI and arthroscopy for the quantification of Hill-Sachs size [70]. They showed moderate agreement (Cohen’s kappa value 0.444) for the size of the lesion as normal, less than 1 cm, or greater than 1 cm.

Discussion

Glenohumeral bone loss is a key factor in predicting recurrent instability following traumatic anterior shoulder dislocation. Increasing size of glenoid and Hill-Sachs lesions are associated with higher failure rates of arthroscopic Bankart repairs. Clinical and biomechanical studies have attempted to determine threshold values of glenohumeral bone loss to use in preoperative planning. Radiography, CT, and MRI have all been explored as imaging modalities for quantification of these glenohumeral bone lesions, with CT being studied most extensively. Within each modality a number of methods have been proposed to quantify the bone loss. There is still a need for further investigation to determine the best modality and method but significant progress has been made since 2000.
Radiography appears to have a role in screening patients for glenoid bone loss; standard radiographic views are straightforward for imaging technicians to obtain but their accuracy is low compared to CT and MRI [42]. Specialized radiographic views are more accurate; however they may be difficult to reproduce clinically due to patient discomfort or apprehension [74]. Slight deviations in gantry orientation or arm positioning may also obscure the bony details [47].
Two general methods emerged when quantifying glenoid bone loss using advanced imaging, width and surface area methods. Each of these methods uses humeral head subtraction and reconstruction to obtain en face views of the glenoid. Because bone loss occurs anteriorly, width methods measure the bone loss in this anterior-posterior dimension in the inferior 2/3 of the glenoid. Ji et al. state that this measurement should be made specifically at 03:20 on a clock face, the most common location of bone loss [13]. The bone loss in the width methods is expressed compared to the pre-injury glenoid. Some authors have used CT scans of the contralateral, uninjured shoulder to obtain the pre-injury width. Others have approximated the pre-injury width by using the intact inferior edges of the injured glenoid to place a circle. Earlier studies suggested that either form of calculating the width loss was adequate, although newer studies have found that using bilateral CT is more accurate [42, 63]. The Glenoid Index (Fig. 5) is the most accurate width measurement method. Surface area methods function by approximating a circle to the inferior glenoid in the same manner as the width methods then finding the area missing. The surface area methods have been studied frequently and have good to excellent reliability [32, 60, 65]. Initially computer software was required to calculate the surface area; however Barchillon et al. showed that one could use a femoral gauge in a clinical setting and still produce accurate results [20]. Comparative studies suggest that the Pico Method based on bilateral CT scans is most accurate and reliable, particularly when using 3DCT versus 2DCT [42, 48, 63]. The accuracy of the Pico method may be affected in part due to the curved nature and concavity of the glenoid. De Felippo et al. have attempted to address this with their De Felippo method that utilizes curved MPR. This was shown to have low interobserver variability and a high correlation with their reference standard. Evidence is currently equivocal if MRI can be used to calculate glenoid bone loss using width and surface area methods in a clinical setting [48, 50, 61]. In comparative studies, CT was found to be more accurate than MRI [42, 48].
Radiography has been shown to be useful in quantifying Hill-Sachs bone loss. Creating a depth/radius ratio on a true AP radiograph with internal rotation is reliable and shown to be clinically relevant, although the accuracy has not been clarified [37, 46, 47]. CT imaging has been used to quantify depth, width, and volume of the lesion. It appears the reliability of CT is good but its accuracy is questionable, often underestimating the size of the lesion [72]. A complicating factor in determining the significance of a Hill-Sachs lesion is the role its orientation plays. More horizontal lesions tend to engage the glenoid lesion and incorporating this factor along with the size is likely important but has not been determined yet [36]. Walia et al. have explored how Hill-Sachs and glenoid lesions interact and engage theoretically and concluded that combined bony defects reduced stability more than expected based on isolated defects alone [30]. The exact way they reduce stability and how to calculate this clinically is unknown.
This study is limited by its qualitative nature. Because the literature has evaluated multiple methods and modalities with different statistical tools it is difficult to pool data and achieve a clear answer of which method is the best. However, this may guide future prospective studies into which method to apply. There was a trend to use either a width or surface-area method, each of which can be applied with the same imaging data set obtained from a CT or MRI. Comparing these methods and correlating with surgical results may give an answer to the best imaging method.

Conclusions

Our scoping review has synthesized the current evidence regarding imaging techniques to quantify glenoid and Hill-Sachs bone loss. A number of modalities and methods have been explored to quantify glenoid bone loss. Radiography does not appear to have the accuracy required for pre-operative planning but may play a role in screening patients that would require advanced imaging. The Bernageau profile view to calculate AP glenoid width is the most accurate radiograph. CT is the most accurate modality but the risk of radiation exposure, particularly when using methods that require bilateral imaging, needs to be considered. Of the methods used with CT, the Glenoid Index is the most accurate and reliable width method while the Pico Method is the most accurate and reliable surface area method. The Glenoid Index requires bilateral shoulder CT and the Pico Method is most accurate when applied using bilateral CT but may also be applied with unilateral imaging. There are equivocal findings about the accuracy or MRI compared to CT and this needs to be clarified by future studies.
A consensus measurement technique for calculating Hill-Sachs bone loss or a threshold size for predicting recurrent instability has not yet been established. Larger lesions, at least >25 % of the humeral head diameter, appear to increase risk of recurrent instability in biomechanical studies [24]. Calculating a depth:radius radio on a true AP radiograph with the arm internally rotated is inexpensive, easy to obtain, and predicts recurrence with good reliability when >20 %. However, its accuracy has not yet been established. Measuring the depth and width on axial slices of a CT scan have good to excellent reliability and have been associated with engaging Hill-Sachs lesions. However the role of CT in predicting recurrence has not been determined.
Ease of calculation, radiation exposure, experience of interpreting radiologist or surgeon, and software availability are factors that should be considered when determining which method will be used. Finally, glenoid and Hill-Sachs bone loss may need to be evaluated together as the manner in which these lesions interact is complex and requires further study.

Acknowledgements

LB receives salary support from the Canadian Institutes of Health Research as a New Investigator (Patient Oriented Research) and Alberta Innovates Health Solutions as a Population Health Investigator.
DMS, MB and LB are members of the Shoulder and Upper Extremity Research Group of Edmonton (SURGE).
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.
The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
The Creative Commons Public Domain Dedication waiver (https://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

DJS, TB, MB, DMS, LB contributed to study concept and design; DS and TB performed data acquisition; DJS, TB, MB, DMS, LB contributed to data analysis, interpretation and drafting and revising the manuscript. All authors read and approved the final draft of the manuscript.
Literatur
1.
Zurück zum Zitat Hovelius L, Olofsson A, Sandstrom B, et al. Nonoperative treatment of primary anterior shoulder dislocation in patients forty years of age and younger. a prospective twenty-five-year follow-up. J Bone Joint Surg Am. 2008;90:945–52.CrossRefPubMed Hovelius L, Olofsson A, Sandstrom B, et al. Nonoperative treatment of primary anterior shoulder dislocation in patients forty years of age and younger. a prospective twenty-five-year follow-up. J Bone Joint Surg Am. 2008;90:945–52.CrossRefPubMed
2.
Zurück zum Zitat Mclaughlin HL, Cavallaro WU. Primary anterior dislocation of the shoulder. Am J Surg. 1950;80:615–21.CrossRefPubMed Mclaughlin HL, Cavallaro WU. Primary anterior dislocation of the shoulder. Am J Surg. 1950;80:615–21.CrossRefPubMed
3.
Zurück zum Zitat Simonet WT, Cofield RH. Prognosis in anterior shoulder dislocation. Am J Sports Med. 1984;12:19–24.CrossRefPubMed Simonet WT, Cofield RH. Prognosis in anterior shoulder dislocation. Am J Sports Med. 1984;12:19–24.CrossRefPubMed
4.
Zurück zum Zitat Hobby J, Griffin D, Dunbar M, Boileau P. Is arthroscopic surgery for stabilisation of chronic shoulder instability as effective as open surgery? A systematic review and meta-analysis of 62 studies including 3044 arthroscopic operations. J Bone Joint Surg (Br). 2007;89:1188–96.CrossRef Hobby J, Griffin D, Dunbar M, Boileau P. Is arthroscopic surgery for stabilisation of chronic shoulder instability as effective as open surgery? A systematic review and meta-analysis of 62 studies including 3044 arthroscopic operations. J Bone Joint Surg (Br). 2007;89:1188–96.CrossRef
5.
Zurück zum Zitat Voos JE, Livermore RW, Feeley BT, et al. Prospective evaluation of arthroscopic bankart repairs for anterior instability. Am J Sports Med. 2010;38:302–7.CrossRefPubMed Voos JE, Livermore RW, Feeley BT, et al. Prospective evaluation of arthroscopic bankart repairs for anterior instability. Am J Sports Med. 2010;38:302–7.CrossRefPubMed
6.
Zurück zum Zitat Ide J, Maeda S, Takagi K. Arthroscopic bankart repair using suture anchors in athletes: Patient selection and postoperative sports activity. Am J Sports Med. 2004;32:1899–905.CrossRefPubMed Ide J, Maeda S, Takagi K. Arthroscopic bankart repair using suture anchors in athletes: Patient selection and postoperative sports activity. Am J Sports Med. 2004;32:1899–905.CrossRefPubMed
7.
Zurück zum Zitat Flinkkila T, Hyvonen P, Ohtonen P, Leppilahti J. Arthroscopic bankart repair: Results and risk factors of recurrence of instability. Knee Surg Sports Traumatol Arthrosc. 2010;18:1752–8.CrossRefPubMed Flinkkila T, Hyvonen P, Ohtonen P, Leppilahti J. Arthroscopic bankart repair: Results and risk factors of recurrence of instability. Knee Surg Sports Traumatol Arthrosc. 2010;18:1752–8.CrossRefPubMed
8.
Zurück zum Zitat Owens BD, Dawson L, Burks R, Cameron KL. Incidence of shoulder dislocation in the united states military: Demographic considerations from a high-risk population. J Bone Joint Surg Am. 2009;91:791–6.CrossRefPubMed Owens BD, Dawson L, Burks R, Cameron KL. Incidence of shoulder dislocation in the united states military: Demographic considerations from a high-risk population. J Bone Joint Surg Am. 2009;91:791–6.CrossRefPubMed
9.
Zurück zum Zitat Randelli P, Ragone V, Carminati S, Cabitza P. Risk factors for recurrence after bankart repair a systematic review. Knee Surg Sports Traumatol Arthrosc. 2012;20:2129–38.CrossRefPubMed Randelli P, Ragone V, Carminati S, Cabitza P. Risk factors for recurrence after bankart repair a systematic review. Knee Surg Sports Traumatol Arthrosc. 2012;20:2129–38.CrossRefPubMed
10.
Zurück zum Zitat Thomazeau H, Courage O, Barth J, et al. Can we improve the indication for bankart arthroscopic repair? A preliminary clinical study using the ISIS score. Orthop Traumatol Surg Res. 2010;96(8 Suppl):S77–83.CrossRefPubMed Thomazeau H, Courage O, Barth J, et al. Can we improve the indication for bankart arthroscopic repair? A preliminary clinical study using the ISIS score. Orthop Traumatol Surg Res. 2010;96(8 Suppl):S77–83.CrossRefPubMed
11.
Zurück zum Zitat Sugaya H, Moriishi J, Dohi M, Kon Y, Tsuchiya A. Glenoid rim morphology in recurrent anterior glenohumeral instability. J Bone Joint Surg Am. 2003;85-A:878–84.PubMed Sugaya H, Moriishi J, Dohi M, Kon Y, Tsuchiya A. Glenoid rim morphology in recurrent anterior glenohumeral instability. J Bone Joint Surg Am. 2003;85-A:878–84.PubMed
12.
Zurück zum Zitat Saito H, Itoi E, Sugaya H, Minagawa H, Yamamoto N, Tuoheti Y. Location of the glenoid defect in shoulders with recurrent anterior dislocation. Am J Sports Med. 2005;33:889–93.CrossRefPubMed Saito H, Itoi E, Sugaya H, Minagawa H, Yamamoto N, Tuoheti Y. Location of the glenoid defect in shoulders with recurrent anterior dislocation. Am J Sports Med. 2005;33:889–93.CrossRefPubMed
13.
Zurück zum Zitat Ji J, Kwak D, Yang P, Kwon MJ, Han S, Jeong J. Comparisons of glenoid bony defects between normal cadaveric specimens and patients with recurrent shoulder dislocation: An anatomic study. J Shoulder Elbow Surg. 2012;21:822–7.CrossRefPubMed Ji J, Kwak D, Yang P, Kwon MJ, Han S, Jeong J. Comparisons of glenoid bony defects between normal cadaveric specimens and patients with recurrent shoulder dislocation: An anatomic study. J Shoulder Elbow Surg. 2012;21:822–7.CrossRefPubMed
14.
Zurück zum Zitat Burkhart SS, De Beer JF. Traumatic glenohumeral bone defects and their relationship to failure of arthroscopic bankart repairs: Significance of the inverted-pear glenoid and the humeral engaging hill-sachs lesion. Arthroscopy. 2000;16:677–94.CrossRefPubMed Burkhart SS, De Beer JF. Traumatic glenohumeral bone defects and their relationship to failure of arthroscopic bankart repairs: Significance of the inverted-pear glenoid and the humeral engaging hill-sachs lesion. Arthroscopy. 2000;16:677–94.CrossRefPubMed
15.
Zurück zum Zitat Burkhart SS, Debeer JF, Tehrany AM, Parten PM. Quantifying glenoid bone loss arthroscopically in shoulder instability. Arthroscopy. 2002;18:488–91.CrossRefPubMed Burkhart SS, Debeer JF, Tehrany AM, Parten PM. Quantifying glenoid bone loss arthroscopically in shoulder instability. Arthroscopy. 2002;18:488–91.CrossRefPubMed
16.
Zurück zum Zitat Itoi E, Lee SB, Berglund LJ, Berge LL, An KN. The effect of a glenoid defect on anteroinferior stability of the shoulder after bankart repair: A cadaveric study. J Bone Joint Surg Am. 2000;82:35–46.PubMed Itoi E, Lee SB, Berglund LJ, Berge LL, An KN. The effect of a glenoid defect on anteroinferior stability of the shoulder after bankart repair: A cadaveric study. J Bone Joint Surg Am. 2000;82:35–46.PubMed
17.
Zurück zum Zitat Gerber C, Nyffeler RW. Classification of glenohumeral joint instability. Clin Orthop Relat Res. 2002;400:65–76.CrossRefPubMed Gerber C, Nyffeler RW. Classification of glenohumeral joint instability. Clin Orthop Relat Res. 2002;400:65–76.CrossRefPubMed
18.
Zurück zum Zitat Itoi E, Lee SB, Amrami KK, Wenger DE, An KN. Quantitative assessment of classic anteroinferior bony bankart lesions by radiography and computed tomography. Am J Sports Med. 2003;31:112–8.PubMed Itoi E, Lee SB, Amrami KK, Wenger DE, An KN. Quantitative assessment of classic anteroinferior bony bankart lesions by radiography and computed tomography. Am J Sports Med. 2003;31:112–8.PubMed
19.
Zurück zum Zitat Yamamoto N, Itoi E, Abe H, et al. Effect of an anterior glenoid defect on anterior shoulder stability: A cadaveric study. Am J Sports Med. 2009;37:949–54.CrossRefPubMed Yamamoto N, Itoi E, Abe H, et al. Effect of an anterior glenoid defect on anterior shoulder stability: A cadaveric study. Am J Sports Med. 2009;37:949–54.CrossRefPubMed
20.
Zurück zum Zitat Barchilon VS, Kotz E, Barchilon Ben-Av M, Glazer E, Nyska M. A simple method for quantitative evaluation of the missing area of the anterior glenoid in anterior instability of the glenohumeral joint. Skeletal Radiol. 2008;37:731–6.CrossRefPubMed Barchilon VS, Kotz E, Barchilon Ben-Av M, Glazer E, Nyska M. A simple method for quantitative evaluation of the missing area of the anterior glenoid in anterior instability of the glenohumeral joint. Skeletal Radiol. 2008;37:731–6.CrossRefPubMed
21.
Zurück zum Zitat Huijsmans PE, Haen PS, Kidd M, Dhert WJ, van der Hulst VPM, Willems WJ. Quantification of a glenoid defect with three-dimensional computed tomography and magnetic resonance imaging: A cadaveric study. J Shoulder Elbow Surg. 2007;16:803–9.CrossRefPubMed Huijsmans PE, Haen PS, Kidd M, Dhert WJ, van der Hulst VPM, Willems WJ. Quantification of a glenoid defect with three-dimensional computed tomography and magnetic resonance imaging: A cadaveric study. J Shoulder Elbow Surg. 2007;16:803–9.CrossRefPubMed
22.
Zurück zum Zitat Yiannakopoulos CK, Mataragas E, Antonogiannakis E. A comparison of the spectrum of intra-articular lesions in acute and chronic anterior shoulder instability. Arthroscopy. 2007;23:985–90.CrossRefPubMed Yiannakopoulos CK, Mataragas E, Antonogiannakis E. A comparison of the spectrum of intra-articular lesions in acute and chronic anterior shoulder instability. Arthroscopy. 2007;23:985–90.CrossRefPubMed
23.
Zurück zum Zitat Saito H, Itoi E, Minagawa H, Yamamoto N, Tuoheti Y, Seki N. Location of the hill-sachs lesion in shoulders with recurrent anterior dislocation. Arch Orthop Trauma Surg. 2009;129(10):1327–34.CrossRefPubMed Saito H, Itoi E, Minagawa H, Yamamoto N, Tuoheti Y, Seki N. Location of the hill-sachs lesion in shoulders with recurrent anterior dislocation. Arch Orthop Trauma Surg. 2009;129(10):1327–34.CrossRefPubMed
24.
Zurück zum Zitat Kaar SG, Fening SD, Jones MH, Colbrunn RW, Miniaci A. Effect of humeral head defect size on glenohumeral stability: A cadaveric study of simulated hill-sachs defects. Am J Sports Med. 2010;38:594–9.CrossRefPubMedPubMedCentral Kaar SG, Fening SD, Jones MH, Colbrunn RW, Miniaci A. Effect of humeral head defect size on glenohumeral stability: A cadaveric study of simulated hill-sachs defects. Am J Sports Med. 2010;38:594–9.CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Sekiya JK, Wickwire AC, Stehle JH, Debski RE. Hill-sachs defects and repair using osteoarticular allograft transplantation: Biomechanical analysis using a joint compression model. Am J Sports Med. 2009;37(12):2459–66.CrossRefPubMed Sekiya JK, Wickwire AC, Stehle JH, Debski RE. Hill-sachs defects and repair using osteoarticular allograft transplantation: Biomechanical analysis using a joint compression model. Am J Sports Med. 2009;37(12):2459–66.CrossRefPubMed
26.
Zurück zum Zitat Sekiya JK, Jolly J, Debski RE. The effect of a hill-sachs defect on glenohumeral translations, in situ capsular forces, and bony contact forces. Am J Sports Med. 2012;40:388–94.CrossRefPubMed Sekiya JK, Jolly J, Debski RE. The effect of a hill-sachs defect on glenohumeral translations, in situ capsular forces, and bony contact forces. Am J Sports Med. 2012;40:388–94.CrossRefPubMed
27.
Zurück zum Zitat Cetik O, Uslu M, Ozsar BK. The relationship between hill-sachs lesion and recurrent anterior shoulder dislocation. Acta Orthop Belg. 2007;73:175–8.PubMed Cetik O, Uslu M, Ozsar BK. The relationship between hill-sachs lesion and recurrent anterior shoulder dislocation. Acta Orthop Belg. 2007;73:175–8.PubMed
28.
Zurück zum Zitat Boileau P, Villalba M, Hery JY, Balg F, Ahrens P, Neyton L. Risk factors for recurrence of shoulder instability after arthroscopic bankart repair. J Bone Joint Surg Am. 2006;88:1755–63.CrossRefPubMed Boileau P, Villalba M, Hery JY, Balg F, Ahrens P, Neyton L. Risk factors for recurrence of shoulder instability after arthroscopic bankart repair. J Bone Joint Surg Am. 2006;88:1755–63.CrossRefPubMed
29.
Zurück zum Zitat Widjaja AB, Tran A, Bailey M, Proper S. Correlation between bankart and hill-sachs lesions in anterior shoulder dislocation. ANZ J Surg. 2006;76:436–8.CrossRefPubMed Widjaja AB, Tran A, Bailey M, Proper S. Correlation between bankart and hill-sachs lesions in anterior shoulder dislocation. ANZ J Surg. 2006;76:436–8.CrossRefPubMed
30.
Zurück zum Zitat Walia P, Miniaci A, Jones MH, Fening SD. Theoretical model of the effect of combined glenohumeral bone defects on anterior shoulder instability: A finite element approach. J Orthop Res. 2013;31:601–7.CrossRefPubMed Walia P, Miniaci A, Jones MH, Fening SD. Theoretical model of the effect of combined glenohumeral bone defects on anterior shoulder instability: A finite element approach. J Orthop Res. 2013;31:601–7.CrossRefPubMed
31.
Zurück zum Zitat Moroder P, Hirzinger C, Lederer S, et al. Restoration of anterior glenoid bone defects in posttraumatic recurrent anterior shoulder instability using the J-bone graft shows anatomic graft remodeling. Am J Sports Med. 2012;40:1544–50.CrossRefPubMed Moroder P, Hirzinger C, Lederer S, et al. Restoration of anterior glenoid bone defects in posttraumatic recurrent anterior shoulder instability using the J-bone graft shows anatomic graft remodeling. Am J Sports Med. 2012;40:1544–50.CrossRefPubMed
32.
Zurück zum Zitat Magarelli N, Milano G, Sergio P, Santagada DA, Fabbriciani C, Bonomo L. Intra-observer and interobserver reliability of the ‘pico’ computed tomography method for quantification of glenoid bone defect in anterior shoulder instability. Skeletal Radiol. 2009;38:1071–5.CrossRefPubMed Magarelli N, Milano G, Sergio P, Santagada DA, Fabbriciani C, Bonomo L. Intra-observer and interobserver reliability of the ‘pico’ computed tomography method for quantification of glenoid bone defect in anterior shoulder instability. Skeletal Radiol. 2009;38:1071–5.CrossRefPubMed
33.
Zurück zum Zitat Griffith JF, Antonio GE, Tong CW, Ming CK. Anterior shoulder dislocation: Quantification of glenoid bone loss with CT. AJRAm J Roentgenol. 2003;180:1423–30.CrossRef Griffith JF, Antonio GE, Tong CW, Ming CK. Anterior shoulder dislocation: Quantification of glenoid bone loss with CT. AJRAm J Roentgenol. 2003;180:1423–30.CrossRef
34.
Zurück zum Zitat Huysmans PE, Haen PS, Kidd M, Dhert WJ, Willems JW. The shape of the inferior part of the glenoid: A cadaveric study. J Shoulder Elbow Surg. 2006;15:759–63.CrossRefPubMed Huysmans PE, Haen PS, Kidd M, Dhert WJ, Willems JW. The shape of the inferior part of the glenoid: A cadaveric study. J Shoulder Elbow Surg. 2006;15:759–63.CrossRefPubMed
35.
Zurück zum Zitat Nofsinger C, Browning B, Burkhart SS, Pedowitz RA. Objective preoperative measurement of anterior glenoid bone loss: A pilot study of a computer-based method using unilateral 3-dimensional computed tomography. Arthroscopy. 2011;27:322–9.CrossRefPubMed Nofsinger C, Browning B, Burkhart SS, Pedowitz RA. Objective preoperative measurement of anterior glenoid bone loss: A pilot study of a computer-based method using unilateral 3-dimensional computed tomography. Arthroscopy. 2011;27:322–9.CrossRefPubMed
36.
Zurück zum Zitat Cho SH, Cho NS, Rhee YG. Preoperative analysis of the hill-sachs lesion in anterior shoulder instability: How to predict engagement of the lesion. Am J Sports Med. 2011;39:2389–95.CrossRefPubMed Cho SH, Cho NS, Rhee YG. Preoperative analysis of the hill-sachs lesion in anterior shoulder instability: How to predict engagement of the lesion. Am J Sports Med. 2011;39:2389–95.CrossRefPubMed
37.
Zurück zum Zitat Hardy P, Lopes R, Bauer T, Conso C, Gaudin P, Sanghavi S. New quantitative measurement of the hill-sachs lesion: A prognostic factor for clinical results of arthroscopic glenohumeral stabilization. Eur J Orthop Surg Trauma. 2012;22:541–7.CrossRef Hardy P, Lopes R, Bauer T, Conso C, Gaudin P, Sanghavi S. New quantitative measurement of the hill-sachs lesion: A prognostic factor for clinical results of arthroscopic glenohumeral stabilization. Eur J Orthop Surg Trauma. 2012;22:541–7.CrossRef
38.
Zurück zum Zitat Ito H, Takayama A, Shirai Y. Radiographic evaluation of the hill-sachs lesion in patients with recurrent anterior shoulder instability. Journal of Shoulder & Elbow Surgery. 2000;9:495–7.CrossRef Ito H, Takayama A, Shirai Y. Radiographic evaluation of the hill-sachs lesion in patients with recurrent anterior shoulder instability. Journal of Shoulder & Elbow Surgery. 2000;9:495–7.CrossRef
39.
Zurück zum Zitat Kralinger FS, Golser K, Wischatta R, Wambacher M, Sperner G. Predicting recurrence after primary anterior shoulder dislocation. Am J Sports Med. 2002;30:116–20.PubMed Kralinger FS, Golser K, Wischatta R, Wambacher M, Sperner G. Predicting recurrence after primary anterior shoulder dislocation. Am J Sports Med. 2002;30:116–20.PubMed
40.
Zurück zum Zitat Arksey H, O’malley L. Scoping studies: Towards a methodological framework. Int J Soc Res Methodol. 2005;8:19–32.CrossRef Arksey H, O’malley L. Scoping studies: Towards a methodological framework. Int J Soc Res Methodol. 2005;8:19–32.CrossRef
42.
Zurück zum Zitat Bishop JY, Jones GL, Rerko MA, Donaldson C, MOON Shoulder G. 3-D CT is the most reliable imaging modality when quantifying glenoid bone loss. Clin Orthop. 2013;471:1251–6.CrossRefPubMed Bishop JY, Jones GL, Rerko MA, Donaldson C, MOON Shoulder G. 3-D CT is the most reliable imaging modality when quantifying glenoid bone loss. Clin Orthop. 2013;471:1251–6.CrossRefPubMed
43.
Zurück zum Zitat Murachovsky J, Bueno RS, Nascimento LG, et al. Calculating anterior glenoid bone loss using the bernageau profile view. Skeletal Radiol. 2012;41:1231–7.CrossRefPubMed Murachovsky J, Bueno RS, Nascimento LG, et al. Calculating anterior glenoid bone loss using the bernageau profile view. Skeletal Radiol. 2012;41:1231–7.CrossRefPubMed
44.
Zurück zum Zitat Rerko MA, Pan X, Donaldson C, Jones GL, Bishop JY. Comparison of various imaging techniques to quantify glenoid bone loss in shoulder instability. J Shoulder Elbow Surg. 2013;22:528–34.CrossRefPubMed Rerko MA, Pan X, Donaldson C, Jones GL, Bishop JY. Comparison of various imaging techniques to quantify glenoid bone loss in shoulder instability. J Shoulder Elbow Surg. 2013;22:528–34.CrossRefPubMed
45.
Zurück zum Zitat Jankauskas L, Rüdiger HA, Pfirrmann CWA, Jost B, Gerber C. Loss of the sclerotic line of the glenoid on anteroposterior radiographs of the shoulder: A diagnostic sign for an osseous defect of the anterior glenoid rim. J Shoulder Elbow Surg. 2010;19:151–6.CrossRefPubMed Jankauskas L, Rüdiger HA, Pfirrmann CWA, Jost B, Gerber C. Loss of the sclerotic line of the glenoid on anteroposterior radiographs of the shoulder: A diagnostic sign for an osseous defect of the anterior glenoid rim. J Shoulder Elbow Surg. 2010;19:151–6.CrossRefPubMed
46.
Zurück zum Zitat Sommaire C, Penz C, Clavert P, Klouche S, Hardy P, Kempf JF. Recurrence after arthroscopic bankart repair: Is quantitative radiological analysis of bone loss of any predictive value? Orthop Trauma Surg Res. 2012;98:514–9.CrossRef Sommaire C, Penz C, Clavert P, Klouche S, Hardy P, Kempf JF. Recurrence after arthroscopic bankart repair: Is quantitative radiological analysis of bone loss of any predictive value? Orthop Trauma Surg Res. 2012;98:514–9.CrossRef
47.
Zurück zum Zitat Charousset C, Beauthier V, Bellaïche L, Guillin R, Brassart N, Thomazeau H. Can we improve radiological analysis of osseous lesions in chronic anterior shoulder instability? Orthop Trauma Surg Res. 2010;96:S88–93.CrossRef Charousset C, Beauthier V, Bellaïche L, Guillin R, Brassart N, Thomazeau H. Can we improve radiological analysis of osseous lesions in chronic anterior shoulder instability? Orthop Trauma Surg Res. 2010;96:S88–93.CrossRef
48.
Zurück zum Zitat Gyftopoulos S, Hasan S, Bencardino J, et al. Diagnostic accuracy of MRI in the measurement of glenoid bone loss. Am J Roentgenol. 2012;199:873–8.CrossRef Gyftopoulos S, Hasan S, Bencardino J, et al. Diagnostic accuracy of MRI in the measurement of glenoid bone loss. Am J Roentgenol. 2012;199:873–8.CrossRef
49.
Zurück zum Zitat Dumont GD, Russell RD, Browne MG, Robertson WJ. Area-based determination of bone loss using the glenoid arc angle. Arthroscopy. 2012;28:1030–5.CrossRefPubMed Dumont GD, Russell RD, Browne MG, Robertson WJ. Area-based determination of bone loss using the glenoid arc angle. Arthroscopy. 2012;28:1030–5.CrossRefPubMed
50.
Zurück zum Zitat Moroder P, Resch H, Schnaitmann S, Hoffelner T, Tauber M. The importance of CT for the pre-operative surgical planning in recurrent anterior shoulder instability. Arch Orthop Trauma Surg. 2013;133:219–26.CrossRefPubMed Moroder P, Resch H, Schnaitmann S, Hoffelner T, Tauber M. The importance of CT for the pre-operative surgical planning in recurrent anterior shoulder instability. Arch Orthop Trauma Surg. 2013;133:219–26.CrossRefPubMed
51.
Zurück zum Zitat Tian CY, Shang Y, Zheng ZZ. Glenoid bone lesions: Comparison between 3D VIBE images in MR arthrography and nonarthrographic MSCT. J Magnet Res Imag. 2012;36:231–6.CrossRef Tian CY, Shang Y, Zheng ZZ. Glenoid bone lesions: Comparison between 3D VIBE images in MR arthrography and nonarthrographic MSCT. J Magnet Res Imag. 2012;36:231–6.CrossRef
52.
Zurück zum Zitat Lee RKL, Griffith JF, Tong MMP, Sharma N, Yung P. Glenoid bone loss: Assessment with MR imaging. Radiology. 2013;267:496–502.CrossRefPubMed Lee RKL, Griffith JF, Tong MMP, Sharma N, Yung P. Glenoid bone loss: Assessment with MR imaging. Radiology. 2013;267:496–502.CrossRefPubMed
53.
Zurück zum Zitat Owens BD, Burns TC, Campbell SE, Svoboda SJ, Cameron KL. Simple method of glenoid bone loss calculation using ipsilateral magnetic resonance imaging. Am J Sports Med. 2013;41:622–4.CrossRefPubMed Owens BD, Burns TC, Campbell SE, Svoboda SJ, Cameron KL. Simple method of glenoid bone loss calculation using ipsilateral magnetic resonance imaging. Am J Sports Med. 2013;41:622–4.CrossRefPubMed
54.
Zurück zum Zitat Saccomanno MF, Deriu L, De Ieso C, Logroscino G, Milano G, Fabbriciani C. Analysis of agreement between computed tomography measurements of glenoid bone defect with and without comparison with the contralateral shoulder. J Orthop TraumaConf: 96th National Congress Italian Soc Orthop Trauma Rimini ItalyConference Publication: (varpagings). 2011;12:S32. Saccomanno MF, Deriu L, De Ieso C, Logroscino G, Milano G, Fabbriciani C. Analysis of agreement between computed tomography measurements of glenoid bone defect with and without comparison with the contralateral shoulder. J Orthop TraumaConf: 96th National Congress Italian Soc Orthop Trauma Rimini ItalyConference Publication: (varpagings). 2011;12:S32.
55.
Zurück zum Zitat Milano G, Grasso A, Russo A, et al. Analysis of risk factors for glenoid bone defect in anterior shoulder instability. Am J Sports Med. 2011;39:1870–6.CrossRefPubMed Milano G, Grasso A, Russo A, et al. Analysis of risk factors for glenoid bone defect in anterior shoulder instability. Am J Sports Med. 2011;39:1870–6.CrossRefPubMed
56.
Zurück zum Zitat Tauber M, Moursy M, Eppel M, Koller H, Resch H. Arthroscopic screw fixation of large anterior glenoid fractures. Knee Surg, Sport Trauma Arthroscopy. 2008;16:326–32.CrossRef Tauber M, Moursy M, Eppel M, Koller H, Resch H. Arthroscopic screw fixation of large anterior glenoid fractures. Knee Surg, Sport Trauma Arthroscopy. 2008;16:326–32.CrossRef
57.
Zurück zum Zitat Magarelli N, Milano G, Baudi P, et al. Comparison between 2D and 3D computed tomography evaluation of glenoid bone defect in unilateral anterior gleno-humeral instability. Radiol Med. 2012;117:102–11.CrossRefPubMed Magarelli N, Milano G, Baudi P, et al. Comparison between 2D and 3D computed tomography evaluation of glenoid bone defect in unilateral anterior gleno-humeral instability. Radiol Med. 2012;117:102–11.CrossRefPubMed
58.
Zurück zum Zitat Griffith JF, Yung PSH, Antonio GE, Tsang PH, Ahuja AT, Kai MC. CT compared with arthroscopy in quantifying glenoid bone loss. Am J Roentgenol. 2007;189(6):1490–3.CrossRef Griffith JF, Yung PSH, Antonio GE, Tsang PH, Ahuja AT, Kai MC. CT compared with arthroscopy in quantifying glenoid bone loss. Am J Roentgenol. 2007;189(6):1490–3.CrossRef
59.
Zurück zum Zitat Diederichs G, Seim H, Meyer H, et al. CT-based patient-specific modeling of glenoid rim defects: A feasibility study. Am J Roentgenol. 2008;191:1406–11.CrossRef Diederichs G, Seim H, Meyer H, et al. CT-based patient-specific modeling of glenoid rim defects: A feasibility study. Am J Roentgenol. 2008;191:1406–11.CrossRef
60.
Zurück zum Zitat Park J, Lee S, Lhee S, Lee S. Follow-up computed tomography arthrographic evaluation of bony bankart lesions after arthroscopic repair. Arthroscopy. 2012;28:465–73.CrossRefPubMed Park J, Lee S, Lhee S, Lee S. Follow-up computed tomography arthrographic evaluation of bony bankart lesions after arthroscopic repair. Arthroscopy. 2012;28:465–73.CrossRefPubMed
61.
Zurück zum Zitat Lee RKL, Griffith JF, Tong MMP, Sharma N, Yung P. Glenoid bone loss: Assessment with MR imaging. Radiology. 2013;267:496–502.CrossRefPubMed Lee RKL, Griffith JF, Tong MMP, Sharma N, Yung P. Glenoid bone loss: Assessment with MR imaging. Radiology. 2013;267:496–502.CrossRefPubMed
62.
Zurück zum Zitat Griffith JF, Antonio GE, Yung PS, et al. Prevalence, pattern, and spectrum of glenoid bone loss in anterior shoulder dislocation: CT analysis of 218 patients. AJR Am J Roentgenol. 2008;190:1247–54.CrossRefPubMed Griffith JF, Antonio GE, Yung PS, et al. Prevalence, pattern, and spectrum of glenoid bone loss in anterior shoulder dislocation: CT analysis of 218 patients. AJR Am J Roentgenol. 2008;190:1247–54.CrossRefPubMed
63.
Zurück zum Zitat Bois AJ, Fening SD, Polster J, Jones MH, Miniaci A. Quantifying glenoid bone loss in anterior shoulder instability: Reliability and accuracy of 2-dimensional and 3-dimensional computed tomography measurement techniques. Am J Sports Med. 2012;40:2569–77.CrossRefPubMed Bois AJ, Fening SD, Polster J, Jones MH, Miniaci A. Quantifying glenoid bone loss in anterior shoulder instability: Reliability and accuracy of 2-dimensional and 3-dimensional computed tomography measurement techniques. Am J Sports Med. 2012;40:2569–77.CrossRefPubMed
64.
Zurück zum Zitat Huijsmans PE, De Witte PB, De Villiers RVP, et al. Recurrent anterior shoulder instability: Accuracy of estimations of glenoid bone loss with computed tomography is insufficient for therapeutic decision-making. Skeletal Radiol. 2011;40:1329–34.CrossRefPubMed Huijsmans PE, De Witte PB, De Villiers RVP, et al. Recurrent anterior shoulder instability: Accuracy of estimations of glenoid bone loss with computed tomography is insufficient for therapeutic decision-making. Skeletal Radiol. 2011;40:1329–34.CrossRefPubMed
65.
Zurück zum Zitat Hantes ME, Venouziou A, Bargiotas KA, Metafratzi Z, Karantanas A, Malizos KN. Repair of an anteroinferior glenoid defect by the latarjet procedure: Quantitative assessment of the repair by computed tomography. Arthroscopy. 2010;26:1021–6.CrossRefPubMed Hantes ME, Venouziou A, Bargiotas KA, Metafratzi Z, Karantanas A, Malizos KN. Repair of an anteroinferior glenoid defect by the latarjet procedure: Quantitative assessment of the repair by computed tomography. Arthroscopy. 2010;26:1021–6.CrossRefPubMed
66.
Zurück zum Zitat De Filippo M, Castagna A, Steinbach LS, et al. Reproducible noninvasive method for evaluation of glenoid bone loss by multiplanar reconstruction curved computed tomographic imaging using a cadaveric model. Arthroscopy. 2013;29:471–7.CrossRefPubMed De Filippo M, Castagna A, Steinbach LS, et al. Reproducible noninvasive method for evaluation of glenoid bone loss by multiplanar reconstruction curved computed tomographic imaging using a cadaveric model. Arthroscopy. 2013;29:471–7.CrossRefPubMed
67.
Zurück zum Zitat D’Elia G, Di Giacomo A, D’Alessandro P, Cirillo LC. Traumatic anterior glenohumeral instability: Quantification of glenoid bone loss by spiral CT. Radiol Med. 2008;113:496–503.CrossRefPubMed D’Elia G, Di Giacomo A, D’Alessandro P, Cirillo LC. Traumatic anterior glenohumeral instability: Quantification of glenoid bone loss by spiral CT. Radiol Med. 2008;113:496–503.CrossRefPubMed
68.
Zurück zum Zitat Chuang TY, Adams CR, Burkhart SS. Use of preoperative three-dimensional computed tomography to quantify glenoid bone loss in shoulder instability. Arthroscopy. 2008;24:376–82.CrossRefPubMed Chuang TY, Adams CR, Burkhart SS. Use of preoperative three-dimensional computed tomography to quantify glenoid bone loss in shoulder instability. Arthroscopy. 2008;24:376–82.CrossRefPubMed
69.
Zurück zum Zitat Van Den Bogaert M, Van Dijk M, Heylen S, Foubert K, Van Glabbeek F. Validation of a CT-based determination of the glenohumeral index. Acta Orthop Belg. 2011;77:167–70. Van Den Bogaert M, Van Dijk M, Heylen S, Foubert K, Van Glabbeek F. Validation of a CT-based determination of the glenohumeral index. Acta Orthop Belg. 2011;77:167–70.
70.
Zurück zum Zitat Kirkley A, Litchfield R, Thain L, Spouge A. Agreement between magnetic resonance imaging and arthroscopic evaluation of the shoulder joint in primary anterior dislocation of the shoulder. Clin J Sport Med. 2003;13:148–51.CrossRefPubMed Kirkley A, Litchfield R, Thain L, Spouge A. Agreement between magnetic resonance imaging and arthroscopic evaluation of the shoulder joint in primary anterior dislocation of the shoulder. Clin J Sport Med. 2003;13:148–51.CrossRefPubMed
71.
Zurück zum Zitat Salomonsson B, von Heine A, Dahlborn M, et al. Bony bankart is a positive predictive factor after primary shoulder dislocation. Knee Surg Sport Trauma Arthroscopy. 2010;18:1425–31.CrossRef Salomonsson B, von Heine A, Dahlborn M, et al. Bony bankart is a positive predictive factor after primary shoulder dislocation. Knee Surg Sport Trauma Arthroscopy. 2010;18:1425–31.CrossRef
72.
Zurück zum Zitat Kodali P, Jones MH, Polster J, Miniaci A, Fening SD. Accuracy of measurement of hill-sachs lesions with computed tomography. J Shoulder Elbow Surg. 2011;20:1328–34.CrossRefPubMed Kodali P, Jones MH, Polster J, Miniaci A, Fening SD. Accuracy of measurement of hill-sachs lesions with computed tomography. J Shoulder Elbow Surg. 2011;20:1328–34.CrossRefPubMed
73.
Zurück zum Zitat Kawasaki S, Nakaguchi T, Ochiai N, Tsumura N, Miyake Y. Quantitative evaluation of humeral head defects by comparing left and right feature - art. no. 69153F. Med Imaging 2008: Computer-Aided Diagnosis, Pts 1 and 2. 2008;6915:F9153. Kawasaki S, Nakaguchi T, Ochiai N, Tsumura N, Miyake Y. Quantitative evaluation of humeral head defects by comparing left and right feature - art. no. 69153F. Med Imaging 2008: Computer-Aided Diagnosis, Pts 1 and 2. 2008;6915:F9153.
74.
Zurück zum Zitat Bigliani LU, Newton PM, Steinmann SP, Connor PM, Mcllveen SJ. Glenoid rim lesions associated with recurrent anterior dislocation of the shoulder. Am J Sports Med. 1998;26:41–5.PubMed Bigliani LU, Newton PM, Steinmann SP, Connor PM, Mcllveen SJ. Glenoid rim lesions associated with recurrent anterior dislocation of the shoulder. Am J Sports Med. 1998;26:41–5.PubMed
75.
Zurück zum Zitat Baudi P, Righi P, Bolognesi D, Rivetta S, Rossi Urtoler E, Guicciardi N, et al. How to identify and calculate glenoid bone deficit. Chir Organi Mov. 2005;90(2):145-52.PubMed Baudi P, Righi P, Bolognesi D, Rivetta S, Rossi Urtoler E, Guicciardi N, et al. How to identify and calculate glenoid bone deficit. Chir Organi Mov. 2005;90(2):145-52.PubMed
Metadaten
Titel
Imaging methods for quantifying glenoid and Hill-Sachs bone loss in traumatic instability of the shoulder: a scoping review
verfasst von
David J. Saliken
Troy D. Bornes
Martin J. Bouliane
David M. Sheps
Lauren A. Beaupre
Publikationsdatum
01.12.2015
Verlag
BioMed Central
Erschienen in
BMC Musculoskeletal Disorders / Ausgabe 1/2015
Elektronische ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-015-0607-1

Weitere Artikel der Ausgabe 1/2015

BMC Musculoskeletal Disorders 1/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.