Skip to main content
Erschienen in: European Journal of Clinical Microbiology & Infectious Diseases 12/2021

01.06.2021 | Brief Report

Impact of 24/7 loading of blood culture bottles in a new automated incubator on the diagnosis of bloodstream infections

verfasst von: Gauthier Péan de Ponfilly, H. Benmansour, V. Manda, E. Lecorche, F. Mougari, A. L. Munier, S. Temim, R. Amarsy, H. Jacquier, E. Cambau

Erschienen in: European Journal of Clinical Microbiology & Infectious Diseases | Ausgabe 12/2021

Einloggen, um Zugang zu erhalten

Abstract

Blood culturing (BC) remains the gold standard for bloodstream diagnosis but its workflow is slow. We aimed reducing this time by implementing a new automated incubator with a 24/7 BC workflow. With this new strategy, time to incubation was shorter (1.52 h vs 6.82 h), positivity rates were higher (10.6% vs 8.9%, p<0.05), and the number of BSI diagnostics increased (16.1% vs 13.8% patients and 2.3 vs 1.9 density episode per 1000 hospital days). Our results show that implementing automatic loading of BC bottles with a 24/7 strategy not only shortened time to diagnosis but significantly increased the BSI diagnosis rate.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
6.
Zurück zum Zitat Thorpe TC, Wilson ML, Turner JE, DiGuiseppi JL, Willert M, Mirrett S et al (1990) BacT/Alert: an automated colorimetric microbial detection system. J Clin Microbiol 28:1608–1612CrossRef Thorpe TC, Wilson ML, Turner JE, DiGuiseppi JL, Willert M, Mirrett S et al (1990) BacT/Alert: an automated colorimetric microbial detection system. J Clin Microbiol 28:1608–1612CrossRef
10.
Zurück zum Zitat Doern GV, Carroll KC, Diekema DJ, Garey KW, Rupp ME, Weinstein MP et al (2019) Practical guidance for clinical microbiology laboratories: a comprehensive update on the problem of blood culture contamination and a discussion of methods for addressing the problem. Clin Microbiol Rev 33:CMR.00009-19, e00009-19. https://doi.org/10.1128/CMR.00009-19CrossRef Doern GV, Carroll KC, Diekema DJ, Garey KW, Rupp ME, Weinstein MP et al (2019) Practical guidance for clinical microbiology laboratories: a comprehensive update on the problem of blood culture contamination and a discussion of methods for addressing the problem. Clin Microbiol Rev 33:CMR.00009-19, e00009-19. https://​doi.​org/​10.​1128/​CMR.​00009-19CrossRef
11.
Zurück zum Zitat Adamik M, Hutchins A, Mangilit J, Katzin B, Totty H, Deol P (2020) Effect of delayed entry on performance of the BACT/ALERT FAN PLUS bottles in the BACT/ALERT VIRTUO blood culture system. Eur J Clin Microbiol Infect Dis Off Publ Eur Soc Clin Microbiol. https://doi.org/10.1007/s10096-020-04042-z Adamik M, Hutchins A, Mangilit J, Katzin B, Totty H, Deol P (2020) Effect of delayed entry on performance of the BACT/ALERT FAN PLUS bottles in the BACT/ALERT VIRTUO blood culture system. Eur J Clin Microbiol Infect Dis Off Publ Eur Soc Clin Microbiol. https://​doi.​org/​10.​1007/​s10096-020-04042-z
12.
Zurück zum Zitat Amarsy-Guerle R, Mougari F, Jacquier H, Oliary J, Benmansour H, Riahi J et al (2015) High medical impact of implementing the new polymeric bead-based BacT/ALERT® FAPlus and FNPlus blood culture bottles in standard care. Eur J Clin Microbiol Infect Dis Off Publ Eur Soc Clin Microbiol 34:1031–1037. https://doi.org/10.1007/s10096-015-2319-8CrossRef Amarsy-Guerle R, Mougari F, Jacquier H, Oliary J, Benmansour H, Riahi J et al (2015) High medical impact of implementing the new polymeric bead-based BacT/ALERT® FAPlus and FNPlus blood culture bottles in standard care. Eur J Clin Microbiol Infect Dis Off Publ Eur Soc Clin Microbiol 34:1031–1037. https://​doi.​org/​10.​1007/​s10096-015-2319-8CrossRef
15.
Zurück zum Zitat Wilson ML (2007) Clinical and Laboratory Standards Institute. Principles and procedures for blood cultures: approved guideline. Clinical and Laboratory Standards Institute, Wayne Wilson ML (2007) Clinical and Laboratory Standards Institute. Principles and procedures for blood cultures: approved guideline. Clinical and Laboratory Standards Institute, Wayne
16.
Zurück zum Zitat Saito T, Iinuma Y, Takakura S, Nagao M, Matsushima A, Shirano M et al (2009) Delayed insertion of blood culture bottles into automated continuously monitoring blood culture systems increases the time from blood sample collection to the detection of microorganisms in bacteremic patients. J Infect Chemother Off J Jpn Soc Chemother 15:49–53. https://doi.org/10.1007/s10156-008-0664-6CrossRef Saito T, Iinuma Y, Takakura S, Nagao M, Matsushima A, Shirano M et al (2009) Delayed insertion of blood culture bottles into automated continuously monitoring blood culture systems increases the time from blood sample collection to the detection of microorganisms in bacteremic patients. J Infect Chemother Off J Jpn Soc Chemother 15:49–53. https://​doi.​org/​10.​1007/​s10156-008-0664-6CrossRef
20.
Zurück zum Zitat Collazos-Blanco A, Pérez-García F, Sánchez-Carrillo C, de Egea V, Muñoz P, Bouza E (2019) Estimation of missed bloodstream infections without the third blood culture set: a retrospective observational single-centre study. Clin Microbiol Infect Off Publ Eur Soc Clin Microbiol Infect Dis 25:469–473. https://doi.org/10.1016/j.cmi.2018.06.024CrossRef Collazos-Blanco A, Pérez-García F, Sánchez-Carrillo C, de Egea V, Muñoz P, Bouza E (2019) Estimation of missed bloodstream infections without the third blood culture set: a retrospective observational single-centre study. Clin Microbiol Infect Off Publ Eur Soc Clin Microbiol Infect Dis 25:469–473. https://​doi.​org/​10.​1016/​j.​cmi.​2018.​06.​024CrossRef
21.
Zurück zum Zitat Dargère S, Parienti J-J, Roupie E, Gancel P-E, Wiel E, Smaiti N et al (2014) Unique blood culture for diagnosis of bloodstream infections in emergency departments: a prospective multicentre study. Clin Microbiol Infect Off Publ Eur Soc Clin Microbiol Infect Dis 20:O920–O927. https://doi.org/10.1111/1469-0691.12656CrossRef Dargère S, Parienti J-J, Roupie E, Gancel P-E, Wiel E, Smaiti N et al (2014) Unique blood culture for diagnosis of bloodstream infections in emergency departments: a prospective multicentre study. Clin Microbiol Infect Off Publ Eur Soc Clin Microbiol Infect Dis 20:O920–O927. https://​doi.​org/​10.​1111/​1469-0691.​12656CrossRef
22.
Zurück zum Zitat Kang C-M, Chen X-J, Chih C-C, Hsu C-C, Chen P-H, Lee TF et al (2020) Rapid identification of bloodstream bacterial and fungal pathogens and their antibiotic resistance determinants from positively flagged blood cultures using the BioFire FilmArray blood culture identification panel. J Microbiol Immunol Infect Wei Mian Yu Gan Ran Za Zhi. https://doi.org/10.1016/j.jmii.2020.03.018 Kang C-M, Chen X-J, Chih C-C, Hsu C-C, Chen P-H, Lee TF et al (2020) Rapid identification of bloodstream bacterial and fungal pathogens and their antibiotic resistance determinants from positively flagged blood cultures using the BioFire FilmArray blood culture identification panel. J Microbiol Immunol Infect Wei Mian Yu Gan Ran Za Zhi. https://​doi.​org/​10.​1016/​j.​jmii.​2020.​03.​018
23.
Metadaten
Titel
Impact of 24/7 loading of blood culture bottles in a new automated incubator on the diagnosis of bloodstream infections
verfasst von
Gauthier Péan de Ponfilly
H. Benmansour
V. Manda
E. Lecorche
F. Mougari
A. L. Munier
S. Temim
R. Amarsy
H. Jacquier
E. Cambau
Publikationsdatum
01.06.2021
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Clinical Microbiology & Infectious Diseases / Ausgabe 12/2021
Print ISSN: 0934-9723
Elektronische ISSN: 1435-4373
DOI
https://doi.org/10.1007/s10096-021-04283-6

Weitere Artikel der Ausgabe 12/2021

European Journal of Clinical Microbiology & Infectious Diseases 12/2021 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.