Skip to main content
Erschienen in: Surgical Endoscopy 2/2019

16.07.2018

Implementation of 3D printed superior mesenteric vascular models for surgical planning and/or navigation in right colectomy with extended D3 mesenterectomy: comparison of virtual and physical models to the anatomy found at surgery

verfasst von: Javier A. Luzon, Bjarte T. Andersen, Bojan V. Stimec, Jean H. D. Fasel, Arne O. Bakka, Airazat M. Kazaryan, Dejan Ignjatovic

Erschienen in: Surgical Endoscopy | Ausgabe 2/2019

Einloggen, um Zugang zu erhalten

Abstract

Background

Three-dimensional (3D) printing technology has recently been well approved as an emerging technology in various fields of medical education and practice; e.g., there are numerous studies evaluating 3D printouts of solid organs. Complex surgery such as extended mesenterectomy imposes a need to analyze also the accuracy of 3D printouts of more mobile and complex structures like the diversity of vascular arborization within the central mesentery. The objective of this study was to evaluate the linear dimensional anatomy landmark differences of the superior mesenteric artery and vein between (1) 3D virtual models, (2) 3D printouts, and (3) peroperative measurements.

Methods

The study included 22 patients from the ongoing prospective multicenter trial “Safe Radical D3 Right Hemicolectomy for Cancer through Preoperative Biphasic MDCT Angiography,” with preoperative CT and peroperative measurements. The patients were operated in Norway between January 2016 and 2017. Their CT datasets underwent 3D volume rendering and segmentation, and the virtual 3D model produced was then exported for stereolithography 3D printing.

Results

Four parameters were measured: distance between the origins of the ileocolic and the middle colic artery, distance between the termination of the gastrocolic trunk and the ileocolic vein, and the calibers of the middle colic and ileocolic arteries. The inter-arterial distance has proven a strong correlation between all the three modalities implied (Pearson’s coefficient 0.968, 0.956, 0.779, respectively), while inter-venous distances showed a weak correlation between peroperative measurements and both virtual and physical models.

Conclusion

This study showed acceptable dimensional inter-arterial correlations between 3D printed models, 3D virtual models and authentic soft tissue anatomy of the central mesenteric vessels, and weaker inter-venous correlations between all the models, reflecting the highly variable nature of veins in situ.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
2.
Zurück zum Zitat Bergamaschi R, Ignjatovic D (2000) More than two structures in Calot’s triangle: a postmortem study. Surg Endosc 14(4):354–357CrossRefPubMed Bergamaschi R, Ignjatovic D (2000) More than two structures in Calot’s triangle: a postmortem study. Surg Endosc 14(4):354–357CrossRefPubMed
7.
Zurück zum Zitat Micallef J, SpringerLink (2015) Beginning design for 3D printing. Technology in action. Imprint, Apress Micallef J, SpringerLink (2015) Beginning design for 3D printing. Technology in action. Imprint, Apress
8.
15.
Zurück zum Zitat Guyton AC, Hall JE (2011) Guyton & Hall physiology review, 2nd edn. edn. Elsevier Saunders, Philadelphia Guyton AC, Hall JE (2011) Guyton & Hall physiology review, 2nd edn. edn. Elsevier Saunders, Philadelphia
16.
Zurück zum Zitat Mescher A (2016) Junqueira’s basic histology: text and atlas. Basic histology (review questions), 14th edn. McGraw-Hill Education LLC, New York Mescher A (2016) Junqueira’s basic histology: text and atlas. Basic histology (review questions), 14th edn. McGraw-Hill Education LLC, New York
17.
Zurück zum Zitat McGregor AD (1987) Prediction of internal arterial diameter from measurement of external diameter. Ann Plast Surg 19(3):217–218CrossRefPubMed McGregor AD (1987) Prediction of internal arterial diameter from measurement of external diameter. Ann Plast Surg 19(3):217–218CrossRefPubMed
18.
Zurück zum Zitat Faury G, Maher GM, Li DY, Keating MT, Mecham RP, Boyle WA (1999) Relation between outer and luminal diameter in cannulated arteries. Am J Physiol 277(5 Pt 2):H1745–H1753PubMed Faury G, Maher GM, Li DY, Keating MT, Mecham RP, Boyle WA (1999) Relation between outer and luminal diameter in cannulated arteries. Am J Physiol 277(5 Pt 2):H1745–H1753PubMed
26.
Zurück zum Zitat Garcia-Granero A, Sanchez-Guillen L, Fletcher-Sanfeliu D, Flor-Lorente B, Frasson M, Sancho Muriel J, Alvarez Serrado E, Pellino G, Grifo Albalat I, Giner F, Roca Estelles MJ, Esclapez Valero P, Garcia-Granero E (2018) Application of three-dimensional printing in laparoscopic dissection to facilitate D3-lymphadenectomy for right colon cancer. Tech Coloproctol 22(2):129–133. https://doi.org/10.1007/s10151-018-1746-9CrossRefPubMed Garcia-Granero A, Sanchez-Guillen L, Fletcher-Sanfeliu D, Flor-Lorente B, Frasson M, Sancho Muriel J, Alvarez Serrado E, Pellino G, Grifo Albalat I, Giner F, Roca Estelles MJ, Esclapez Valero P, Garcia-Granero E (2018) Application of three-dimensional printing in laparoscopic dissection to facilitate D3-lymphadenectomy for right colon cancer. Tech Coloproctol 22(2):129–133. https://​doi.​org/​10.​1007/​s10151-018-1746-9CrossRefPubMed
Metadaten
Titel
Implementation of 3D printed superior mesenteric vascular models for surgical planning and/or navigation in right colectomy with extended D3 mesenterectomy: comparison of virtual and physical models to the anatomy found at surgery
verfasst von
Javier A. Luzon
Bjarte T. Andersen
Bojan V. Stimec
Jean H. D. Fasel
Arne O. Bakka
Airazat M. Kazaryan
Dejan Ignjatovic
Publikationsdatum
16.07.2018
Verlag
Springer US
Erschienen in
Surgical Endoscopy / Ausgabe 2/2019
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-018-6332-8

Weitere Artikel der Ausgabe 2/2019

Surgical Endoscopy 2/2019 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.