Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 3/2012

01.03.2012 | Original Paper

In vivo evaluation of stent patency by 64-slice multidetector CT coronary angiography: shall we do it or not?

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 3/2012

Einloggen, um Zugang zu erhalten

Abstract

The diagnostic performance of in-stent restenosis (ISR) by 64-slice multidetector CT coronary angiography (CTCA) has been reported to be influenced by multiple factors. We evaluated individual factors (stent diameter, material and strut thickness) and therefore determined the proper population for follow-up by using this modality. A total of 171 stents were evaluated in 83 consecutive patients with stents imaged with CTCA and conventional coronary angiography. The stent diameter ranged from 2.25 mm to 4.5 mm. 2 models of stainless steel (Taxus Liberte (Boston Scientific, US), 56 stents and Cypher Select (Cordis, US), 34 stents) and 2 models of cobalt alloy (Endeavor (Medtronic, US), 33 stents and Firebird2 (MicroPort, China), 48 stents) were included. By comparing to conventional coronary angiography, the image quality and diagnostic accuracy for ISR were evaluated. The image quality of Taxus, Endeavor and Firebird are markedly better than Cypher in large caliber group (≧3.0 mm) (P < 0.001). Except for Cypher, all other stents with diameter ≧3.0 mm showed excellent diagnostic accuracy (sensitivity 100%, specificity 94.4–96% whereas stents with diameter <3.0 mm had poor diagnostic accuracy (sensitivity 100%, specificity 33.3–70%). Cypher is the stent with thickest strut in our study, and showed reduced image quality and diagnostic accuracy in all stent size, due to large number of unassessable stents. Among 16 binary ISR, 12 lesions were correctly diagnosed by CTCA while the other 4 lesions were unassessable. The main reason for low specificity in small caliber group is the large number of unassessable stents. CTCA has high diagnostic accuracy to identify ISR in selected stents with a diameter of ≧3.0 mm.
Literatur
1.
Zurück zum Zitat Sousa JE, Serruys PW, Costa MA (2003) New frontiers in cardiology: drug-eluting stents: Part I. Circulation 107:2274–2279PubMedCrossRef Sousa JE, Serruys PW, Costa MA (2003) New frontiers in cardiology: drug-eluting stents: Part I. Circulation 107:2274–2279PubMedCrossRef
2.
Zurück zum Zitat Sousa JE, Serruys PW, Costa MA (2003) New frontiers in cardiology: drug-eluting stents: Part II. Circulation 107:2283–2289 Sousa JE, Serruys PW, Costa MA (2003) New frontiers in cardiology: drug-eluting stents: Part II. Circulation 107:2283–2289
3.
Zurück zum Zitat Moses JW, Leon MB, Popma JJ et al (2003) Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 349:1315–1323PubMedCrossRef Moses JW, Leon MB, Popma JJ et al (2003) Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 349:1315–1323PubMedCrossRef
4.
Zurück zum Zitat Stone GW, Ellis SG, Cox DA et al (2004) A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 350:221–231PubMedCrossRef Stone GW, Ellis SG, Cox DA et al (2004) A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 350:221–231PubMedCrossRef
5.
Zurück zum Zitat De Bono D, The Joint Audit Committee of the British Cardiac Society, Royal College of Physicians of London (1993) Complications of diagnostic cardiac catheterisation: results from 34,041 patients in the United Kingdom confidential enquiry into cardiac catheter complications. Br Heart J 70:297–300PubMedCrossRef De Bono D, The Joint Audit Committee of the British Cardiac Society, Royal College of Physicians of London (1993) Complications of diagnostic cardiac catheterisation: results from 34,041 patients in the United Kingdom confidential enquiry into cardiac catheter complications. Br Heart J 70:297–300PubMedCrossRef
6.
Zurück zum Zitat Young N, Chi KK, Ajaka J et al (2002) Complications with outpatient angiography and interventional procedures. Cardiovasc Intervent Radiol 25:123–126PubMedCrossRef Young N, Chi KK, Ajaka J et al (2002) Complications with outpatient angiography and interventional procedures. Cardiovasc Intervent Radiol 25:123–126PubMedCrossRef
7.
Zurück zum Zitat Stein PD, Yaekoub AY, Matta F et al (2008) 64-slice CT for diagnosis of coronary artery disease: a systematic review. Am J Med 121:715–725PubMedCrossRef Stein PD, Yaekoub AY, Matta F et al (2008) 64-slice CT for diagnosis of coronary artery disease: a systematic review. Am J Med 121:715–725PubMedCrossRef
8.
Zurück zum Zitat Daniel BM, Daniel SB, Matthew JB et al (2010) ACCF/ACR/AHA/NASCI/SAIP/SCAI/SCCT 2010 Expert consensus document on coronary computed tomographic angiography: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents. Circulation 121:2509–2543CrossRef Daniel BM, Daniel SB, Matthew JB et al (2010) ACCF/ACR/AHA/NASCI/SAIP/SCAI/SCCT 2010 Expert consensus document on coronary computed tomographic angiography: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents. Circulation 121:2509–2543CrossRef
9.
Zurück zum Zitat Ehara M, Surmely JF, Kawai M et al (2006) Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography. Circ J 70:564–571PubMedCrossRef Ehara M, Surmely JF, Kawai M et al (2006) Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography. Circ J 70:564–571PubMedCrossRef
10.
Zurück zum Zitat Austen WG, Edwards JE, Frye RL et al (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40PubMed Austen WG, Edwards JE, Frye RL et al (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40PubMed
11.
Zurück zum Zitat Tanabe K, Serruys PW, Grube E et al (2003) TAXUS III Trial: in-stent restenosis treated with stent-based delivery of paclitaxel incorporated in a slow-release polymer formulation. Circulation 107:559–564PubMedCrossRef Tanabe K, Serruys PW, Grube E et al (2003) TAXUS III Trial: in-stent restenosis treated with stent-based delivery of paclitaxel incorporated in a slow-release polymer formulation. Circulation 107:559–564PubMedCrossRef
12.
Zurück zum Zitat Fajadet J, Morice MC, Bode C et al (2005) Maintenance of long-term clinical benefit with sirolimus-eluting coronary stents: three-year results of the RAVEL trial. Circulation 111:1040–1044PubMedCrossRef Fajadet J, Morice MC, Bode C et al (2005) Maintenance of long-term clinical benefit with sirolimus-eluting coronary stents: three-year results of the RAVEL trial. Circulation 111:1040–1044PubMedCrossRef
13.
Zurück zum Zitat Ehara M, Kawai M, Surmely JF et al (2007) Diagnostic accuracy of coronary in-stent restenosis using 64-slice computed tomography: comparison with invasive coronary angiography. JACC 49:951–959PubMed Ehara M, Kawai M, Surmely JF et al (2007) Diagnostic accuracy of coronary in-stent restenosis using 64-slice computed tomography: comparison with invasive coronary angiography. JACC 49:951–959PubMed
14.
Zurück zum Zitat Rist C, von Ziegler F, Nikolaou K et al (2006) Assessment of coronary artery stent patency and restenosis using 64-slice computed tomography. Acad Radiol 13:1465–1473PubMedCrossRef Rist C, von Ziegler F, Nikolaou K et al (2006) Assessment of coronary artery stent patency and restenosis using 64-slice computed tomography. Acad Radiol 13:1465–1473PubMedCrossRef
15.
Zurück zum Zitat Rixe J, Achenbach S, Ropers D et al (2006) Assessment of coronary artery stent restenosis by 64-slice multi-detector computed tomography. Eur Heart J 27:2567–2572PubMedCrossRef Rixe J, Achenbach S, Ropers D et al (2006) Assessment of coronary artery stent restenosis by 64-slice multi-detector computed tomography. Eur Heart J 27:2567–2572PubMedCrossRef
16.
Zurück zum Zitat Cademartiri F, Schuijf JD, Pugliese F et al (2007) Usefulness of 64-slice multislice computed tomography coronary angiography to assess in-stent restenosis. J Am Coll Cardiol 49:2204–2210PubMedCrossRef Cademartiri F, Schuijf JD, Pugliese F et al (2007) Usefulness of 64-slice multislice computed tomography coronary angiography to assess in-stent restenosis. J Am Coll Cardiol 49:2204–2210PubMedCrossRef
17.
Zurück zum Zitat Oncel D, Oncel G, Karaca M (2007) Coronary stent patency and in-stent restenosis: determination with 64-section multidetector CT coronary angiography-initial experience. Radiology 242:403–408PubMedCrossRef Oncel D, Oncel G, Karaca M (2007) Coronary stent patency and in-stent restenosis: determination with 64-section multidetector CT coronary angiography-initial experience. Radiology 242:403–408PubMedCrossRef
18.
Zurück zum Zitat Gaspar T, Halon D, Lewis B et al (2005) Diagnosis of coronary in-stent restenosis with multidetector row spiral computed tomography. JACC 46:1573–1579PubMed Gaspar T, Halon D, Lewis B et al (2005) Diagnosis of coronary in-stent restenosis with multidetector row spiral computed tomography. JACC 46:1573–1579PubMed
19.
Zurück zum Zitat Maintz D, Seifarth H, Raupach R et al (2006) 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents. Eur Radiol 16:818–826PubMedCrossRef Maintz D, Seifarth H, Raupach R et al (2006) 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents. Eur Radiol 16:818–826PubMedCrossRef
20.
Zurück zum Zitat Maintz D, Burg MC, Seifarth H et al (2009) Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT. Eur Radiol 19:42–49PubMedCrossRef Maintz D, Burg MC, Seifarth H et al (2009) Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT. Eur Radiol 19:42–49PubMedCrossRef
Metadaten
Titel
In vivo evaluation of stent patency by 64-slice multidetector CT coronary angiography: shall we do it or not?
Publikationsdatum
01.03.2012
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 3/2012
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-011-9842-1

Weitere Artikel der Ausgabe 3/2012

The International Journal of Cardiovascular Imaging 3/2012 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.