Purpose

Pelvic incidence (PI), pelvic tilt (PT) and sacral slope (SS) are important parameters in sagittal spine alignment evaluation. The measurements are a projection of the three-dimensional pelvis onto a two-dimensional radiograph and they may be influenced by orientation of the pelvis. The aim of this study was to assess the influence of pelvic rotation in the coronal plane (CPR) on radiographic accuracy of PI, PT, and SS measurements.

Methods

Radiological evaluation of the CPR angel was performed on 1 radiological phantom. The radiographs were taken in 5° CPR increments over a range of 0°–45° (evaluated with a digital protractor). On each of the lateral radiograph, PI, PT, and SS were measured three times by three independent researchers. The lowest CPR that changed PI, PT, or SS by ≥6° (the highest reported error of measurement of these parameters) was considered as unacceptable. Next, CPR was calculated based on the distance between femoral heads (FHD). The agreement of the calculated and measured CPR was quantified by the intraclass correlation coefficient (ICC) and the median error for a single measurement (SEM), with value 0.75 considered as excellent agreement.

Results

PI, PT and SS could be measured with an acceptable error of 6° on radiographs with up to 20° pelvic rotation. From 20° CPR onwards the S1 endplate was distorted, that makes the measurements of PI, PT and SS questionable. There was an excellent agreement between CPR measured with a protractor and calculated based on FHD with ICC of 0.99 and SEM of 1.1°.

Conclusions

Rotation of the pelvis in the coronal plane during acquisition of radiographs influences PI, PT and SS measurements. Substantial error of PI, PT and SS measurements occurs with CPR of more than 20° which is equivalent to a lower limb discrepancy of 5.2 cm. CPR may be calculated while acquiring the radiograph. Further evaluation of the influence of CPR on spinopelvic parameters with a larger sample would be valuable.
Literatur
2.
Zurück zum Zitat Lazennec JY, Ramare S, Arafati N, Laudet CG, Gorin M, Roger B, Hansen S, Saillant G, Maurs L, Trabelsi R (2000) Sagittal alignment in lumbosacral fusion: relations between radiological parameters and pain. Eur Spine J 9:47–55CrossRefPubMedPubMedCentral Lazennec JY, Ramare S, Arafati N, Laudet CG, Gorin M, Roger B, Hansen S, Saillant G, Maurs L, Trabelsi R (2000) Sagittal alignment in lumbosacral fusion: relations between radiological parameters and pain. Eur Spine J 9:47–55CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Glassman SD, Berven S, Bridwell K, Horton W, Dimar JR (2005) Correlation of radiographic parameters and clinical symptoms in adult scoliosis. Spine 30:682–688CrossRefPubMed Glassman SD, Berven S, Bridwell K, Horton W, Dimar JR (2005) Correlation of radiographic parameters and clinical symptoms in adult scoliosis. Spine 30:682–688CrossRefPubMed
5.
Zurück zum Zitat Duval-Beaupere G, Schmidt C, Cosson P (1992) A barycentremetric study of the sagittal shape of spine and pelvis: the conditions required for an economic standing position. Ann Biomed Eng 20:451–462CrossRefPubMed Duval-Beaupere G, Schmidt C, Cosson P (1992) A barycentremetric study of the sagittal shape of spine and pelvis: the conditions required for an economic standing position. Ann Biomed Eng 20:451–462CrossRefPubMed
8.
Zurück zum Zitat Legaye J, Duval-Beaupere G, Hecquet J, Marty C (1998) Pelvic incidence: a fundamental pelvic parameter for three-dimensional regulation of spinal sagittal curves. Eur Spine J 7:99–103CrossRefPubMedPubMedCentral Legaye J, Duval-Beaupere G, Hecquet J, Marty C (1998) Pelvic incidence: a fundamental pelvic parameter for three-dimensional regulation of spinal sagittal curves. Eur Spine J 7:99–103CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Tyrakowski M, Yu H, Siemionow K (2014) Pelvic incidence and pelvic tilt measurements using femoral heads or acetabular domes to identify centers of the hips: comparison of two methods. Eur Spine J. doi:10.1007/s00586-014-3739-3 Tyrakowski M, Yu H, Siemionow K (2014) Pelvic incidence and pelvic tilt measurements using femoral heads or acetabular domes to identify centers of the hips: comparison of two methods. Eur Spine J. doi:10.​1007/​s00586-014-3739-3
11.
Zurück zum Zitat Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86(2):420–428CrossRefPubMed Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86(2):420–428CrossRefPubMed
12.
Zurück zum Zitat Streiner DLNG (2008) Health measurement scales—a practical guide to their development and use, 4th edn. Oxford University Press, Oxford, New YorkCrossRef Streiner DLNG (2008) Health measurement scales—a practical guide to their development and use, 4th edn. Oxford University Press, Oxford, New YorkCrossRef
13.
Zurück zum Zitat Jackson RP, Peterson MD, McManus AC, Hales C (1998) Compensatory spinopelvic balance over the hip axis and better reliability in measuring lordosis to the pelvic radius on standing lateral radiographs of adult volunteers and patients. Spine 23:1750–1767CrossRefPubMed Jackson RP, Peterson MD, McManus AC, Hales C (1998) Compensatory spinopelvic balance over the hip axis and better reliability in measuring lordosis to the pelvic radius on standing lateral radiographs of adult volunteers and patients. Spine 23:1750–1767CrossRefPubMed
14.
Zurück zum Zitat Winter RB, Pinto WC (1986) Pelvic obliquity. Its causes and its treatment. Spine 11:225–234CrossRefPubMed Winter RB, Pinto WC (1986) Pelvic obliquity. Its causes and its treatment. Spine 11:225–234CrossRefPubMed
16.
Zurück zum Zitat Nissinen M, Heliovaara M, Tallroth K, Poussa M (1989) Trunk asymmetry and scoliosis, anthropometric measurements in prepuberal school children. Acta Paediatr Scand 78:747–753CrossRefPubMed Nissinen M, Heliovaara M, Tallroth K, Poussa M (1989) Trunk asymmetry and scoliosis, anthropometric measurements in prepuberal school children. Acta Paediatr Scand 78:747–753CrossRefPubMed
18.
Zurück zum Zitat Mullaji A, Shetty GM, Kanna R, Sharma A (2010) Variability in the range of inter-anterior superior iliac spine distance and its correlation with femoral head centre. A prospective computed tomography study of 200 adults. Skeletal Radiol 39:363–368. doi:10.1007/s00256-009-0791-x CrossRefPubMed Mullaji A, Shetty GM, Kanna R, Sharma A (2010) Variability in the range of inter-anterior superior iliac spine distance and its correlation with femoral head centre. A prospective computed tomography study of 200 adults. Skeletal Radiol 39:363–368. doi:10.​1007/​s00256-009-0791-x CrossRefPubMed
Metadaten
Titel
Influence of lower limbs discrepancy and pelvic coronal rotation on pelvic incidence, pelvic tilt and sacral slope
verfasst von
Piotr Janusz
Marcin Tyrakowski
Jad Bou Monsef
Kris Siemionow
Publikationsdatum
03.03.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe 11/2016
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-016-4458-8

Weitere Artikel der Ausgabe 11/2016

European Spine Journal 11/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.