Skip to main content
Erschienen in: Spektrum der Augenheilkunde 1/2020

29.04.2019 | original article

Influence of optic media of the human eye on the imaging of Argus® II retinal prosthesis with intraoperative spectral-domain optical coherence tomography

verfasst von: Lyubomyr M. Lytvynchuk, MD, PhD, Christiane I. Falkner-Radler, MD, Andrzej Grzybowski, MD, PhD, Carl G. Glittenberg, MD, Farnusch Shams-Mafi, MD, Siamak Ansari-Shahrezaei, MD, Susanne Binder, MD

Erschienen in: Spektrum der Augenheilkunde | Ausgabe 1/2020

Einloggen, um Zugang zu erhalten

Summary

Background

This study aimed to evaluate the influence of the optic media of the human eye on intraoperative spectral-domain optical coherence tomography (iSD-OCT) of an Argus® II retinal prosthesis (AIIRP) during its implantation.

Methods

One AIIRP was implanted in a human eye with end-stage retinitis pigmentosa and another one in a test eye. Intraoperative imaging was performed using the Rescan™ 700, a microscope-integrated iSD-OCT system. The feasibility of iSD-OCT imaging for AIIRP implantation was assessed during different surgical steps. Data were post-processed postoperatively using the ImageJ graphic software.

Results

The quality of imaging of the AIIRP during its implantation was good and almost the same in the human eye and in the training eye. The histograms showed that the optic media had no impact on the quality of iSD-OCT scans, as the difference between the pixel values was not statistically significant. Additionally, the quality of iSD-OCT imaging of the retina under the AIIRP array was not decreased by the array itself.

Conclusion

The iSD-OCT-assisted surgical approach facilitates imaging of the AIIRP during its implantation. Uncompromised human optic media do not reduce the quality of AIIRP array imaging throughout all the surgical steps. The influence of the opaque cornea in long-lasting surgeries on the iSD-OCT scan quality during AIIRP implantation has to be investigated.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
2.
Zurück zum Zitat Binder S, Lytvynchuk LM. Argus II Retina Implantat bei an Retinopathia pigmentosa erblindeter Patientin. Spektrum Augenheilkd. 2016;30:100–5.CrossRef Binder S, Lytvynchuk LM. Argus II Retina Implantat bei an Retinopathia pigmentosa erblindeter Patientin. Spektrum Augenheilkd. 2016;30:100–5.CrossRef
3.
Zurück zum Zitat Luo Y, da Cruz L. The Argus(®) II Retinal Prosthesis System. Prog Retin Eye Res. 2016;50:89–107.PubMedCrossRef Luo Y, da Cruz L. The Argus(®) II Retinal Prosthesis System. Prog Retin Eye Res. 2016;50:89–107.PubMedCrossRef
4.
Zurück zum Zitat Rizzo S, Belting C, Cinelli L, Allegrini L, Genovese-Ebert F, Barca F, di Bartolo E. The Arguss II Retinal Prosthesis: 12-month outcome from a single-study centre. Am J Ophthalmol. 2014;157(6):1282–90.PubMedCrossRef Rizzo S, Belting C, Cinelli L, Allegrini L, Genovese-Ebert F, Barca F, di Bartolo E. The Arguss II Retinal Prosthesis: 12-month outcome from a single-study centre. Am J Ophthalmol. 2014;157(6):1282–90.PubMedCrossRef
5.
Zurück zum Zitat Ghodasra DH, Chen A, Arevalo JF, Birch DG, Branham K, Coley B, Dagnelie G, de Juan E, Devenyi RG, Dorn JD, Fisher A. Worldwide Argus II implantation: recommendations to optimize patient outcomes. BMC Ophthalmol. 2016;16(1):1.CrossRef Ghodasra DH, Chen A, Arevalo JF, Birch DG, Branham K, Coley B, Dagnelie G, de Juan E, Devenyi RG, Dorn JD, Fisher A. Worldwide Argus II implantation: recommendations to optimize patient outcomes. BMC Ophthalmol. 2016;16(1):1.CrossRef
6.
Zurück zum Zitat Delyfer M, Gaucher D, Govare M, Cougnard-Grégoire A, Korobelnik J, Ajana S, Mohand-Saïd S, Ayello-Scheer S, Rezaiguia-Studer F, Dollfus H, Sahel J, Barale P. Adapted surgical procedure for argus II retinal implantation: feasibility, safety, efficiency, and postoperative anatomic findings. Ophthalmol Retin. 2018;2:276–87.CrossRef Delyfer M, Gaucher D, Govare M, Cougnard-Grégoire A, Korobelnik J, Ajana S, Mohand-Saïd S, Ayello-Scheer S, Rezaiguia-Studer F, Dollfus H, Sahel J, Barale P. Adapted surgical procedure for argus II retinal implantation: feasibility, safety, efficiency, and postoperative anatomic findings. Ophthalmol Retin. 2018;2:276–87.CrossRef
7.
Zurück zum Zitat Weiland JD, Cho AK, Humayun MS. Retinal prostheses: current clinical results and future needs. Ophthalmology. 2011;118(11):2227–37.PubMedCrossRef Weiland JD, Cho AK, Humayun MS. Retinal prostheses: current clinical results and future needs. Ophthalmology. 2011;118(11):2227–37.PubMedCrossRef
8.
Zurück zum Zitat Israelsen PE, Sadda SR, Dorn JD, Humayun MS, Olmos de Koo LC. Optomap widefield imaging of the argus ii retinal prosthesis in patients with retinitis pigmentosa. Retin Cases Brief Rep. 2016;10(4):382–5.PubMedCrossRef Israelsen PE, Sadda SR, Dorn JD, Humayun MS, Olmos de Koo LC. Optomap widefield imaging of the argus ii retinal prosthesis in patients with retinitis pigmentosa. Retin Cases Brief Rep. 2016;10(4):382–5.PubMedCrossRef
11.
Zurück zum Zitat Luo YH, Davagnanam I, da Cruz L. MRI brain scan in two patients with the Argus II retinal prothesis. Ophthalmology. 2013;120(8):1711–1711.PubMedCrossRef Luo YH, Davagnanam I, da Cruz L. MRI brain scan in two patients with the Argus II retinal prothesis. Ophthalmology. 2013;120(8):1711–1711.PubMedCrossRef
12.
Zurück zum Zitat Weiland JD, Faraji B, Greenberg RJ, Humayun MS, Shellock FG. Assessment of MRI issues for the Argus II retinal prosthesis. Magn Reson Imaging. 2012;30(3):382–9.PubMedCrossRef Weiland JD, Faraji B, Greenberg RJ, Humayun MS, Shellock FG. Assessment of MRI issues for the Argus II retinal prosthesis. Magn Reson Imaging. 2012;30(3):382–9.PubMedCrossRef
13.
Zurück zum Zitat Tamaki M, Matsuo T. Optical coherence tomographic parameters as objective signs for visual acuity in patients with retinitis pigmentosa, future candidates for retinal prosthesis. Artif Organs. 2011;14(2):140–50.CrossRef Tamaki M, Matsuo T. Optical coherence tomographic parameters as objective signs for visual acuity in patients with retinitis pigmentosa, future candidates for retinal prosthesis. Artif Organs. 2011;14(2):140–50.CrossRef
14.
Zurück zum Zitat Binder S, Falkner-Radler CI, Hauger C, Matz H, Glittenberg C. Feasibility of intrasurgical spectral-domain optical coherence tomography. Retina. 2011;31(7):1332–6.PubMedCrossRef Binder S, Falkner-Radler CI, Hauger C, Matz H, Glittenberg C. Feasibility of intrasurgical spectral-domain optical coherence tomography. Retina. 2011;31(7):1332–6.PubMedCrossRef
15.
Zurück zum Zitat Ehlers J, Srivastava S, Feiler D, Noonan A, Rollins A, Tao Y. Integrative advances for OCT-guided ophthalmic surgery and intraoperative OCT: microscope integration, surgical instrumentation, and heads-up display surgeon feedback. PLoS ONE. 2014;9(8):e105224.PubMedPubMedCentralCrossRef Ehlers J, Srivastava S, Feiler D, Noonan A, Rollins A, Tao Y. Integrative advances for OCT-guided ophthalmic surgery and intraoperative OCT: microscope integration, surgical instrumentation, and heads-up display surgeon feedback. PLoS ONE. 2014;9(8):e105224.PubMedPubMedCentralCrossRef
16.
Zurück zum Zitat Falkner-Radler C, Glittenberg C, Gabriel M, Binder S. Intrasurgical microscope-integrated spectral domain optical coherence tomography-assisted membrane peeling. Retina. 2015;35(10):2100–6.PubMedCrossRef Falkner-Radler C, Glittenberg C, Gabriel M, Binder S. Intrasurgical microscope-integrated spectral domain optical coherence tomography-assisted membrane peeling. Retina. 2015;35(10):2100–6.PubMedCrossRef
17.
Zurück zum Zitat Lytvynchuk LM, Glittenberg CG, Falkner-Radler CI, Neumaier-Ammerer B, Smretschnig E, Hagen S, Ansari-Shahrezaei S, Binder S. Evaluation of intraocular lens position during phacoemulsification using intraoperative spectral-domain optical coherence tomography. J Cataract Refract Surg. 2016;42(5):694–702.PubMedCrossRef Lytvynchuk LM, Glittenberg CG, Falkner-Radler CI, Neumaier-Ammerer B, Smretschnig E, Hagen S, Ansari-Shahrezaei S, Binder S. Evaluation of intraocular lens position during phacoemulsification using intraoperative spectral-domain optical coherence tomography. J Cataract Refract Surg. 2016;42(5):694–702.PubMedCrossRef
18.
Zurück zum Zitat Ehlers JP, Goshe J, Dupps WJ, et al. Determination of feasibility and utility of microscope-integrated optical coherence tomography during ophthalmic surgery: the DISCOVER study RESCAN results. JAMA Ophthalmol. 2015;133(10):1124–32.PubMedPubMedCentralCrossRef Ehlers JP, Goshe J, Dupps WJ, et al. Determination of feasibility and utility of microscope-integrated optical coherence tomography during ophthalmic surgery: the DISCOVER study RESCAN results. JAMA Ophthalmol. 2015;133(10):1124–32.PubMedPubMedCentralCrossRef
19.
Zurück zum Zitat Lytvynchuk LM, Glittenberg CG, Ansari-Shahrezaei S, Binder S. Intraoperative optical coherence tomography assisted analysis of pars Plana vitrectomy for retinal detachment in morning glory syndrome: a case report. BMC Ophthalmol. 2017;17:134–131.PubMedPubMedCentralCrossRef Lytvynchuk LM, Glittenberg CG, Ansari-Shahrezaei S, Binder S. Intraoperative optical coherence tomography assisted analysis of pars Plana vitrectomy for retinal detachment in morning glory syndrome: a case report. BMC Ophthalmol. 2017;17:134–131.PubMedPubMedCentralCrossRef
20.
Zurück zum Zitat Seider MI, Hahn P. Argus II retinal prosthesis malrotation and repositioning with intraoperative optical coherence tomography in a posterior staphyloma. Clin Ophthalmol. 2015;9:2213.PubMedPubMedCentralCrossRef Seider MI, Hahn P. Argus II retinal prosthesis malrotation and repositioning with intraoperative optical coherence tomography in a posterior staphyloma. Clin Ophthalmol. 2015;9:2213.PubMedPubMedCentralCrossRef
21.
Zurück zum Zitat Rachitskaya A, Yuan A, Marino M, Reese J, Ehlers J. Intraoperative OCT imaging of the Argus II retinal prosthesis system. Ophthalmic Surg Lasers Imaging Retina. 2016;47(11):999–1003.PubMedPubMedCentralCrossRef Rachitskaya A, Yuan A, Marino M, Reese J, Ehlers J. Intraoperative OCT imaging of the Argus II retinal prosthesis system. Ophthalmic Surg Lasers Imaging Retina. 2016;47(11):999–1003.PubMedPubMedCentralCrossRef
23.
Zurück zum Zitat Ahuja AK, Yeoh J, Dorn JD, Caspi A, Wuyyuru V, McMahon MJ, Humayun MS, Greenberg RJ, Dacruz L. Factors affecting perceptual threshold in Argus II retinal prosthesis subjects. Transl Vis Sci Technol. 2013;2(4):1.PubMedPubMedCentralCrossRef Ahuja AK, Yeoh J, Dorn JD, Caspi A, Wuyyuru V, McMahon MJ, Humayun MS, Greenberg RJ, Dacruz L. Factors affecting perceptual threshold in Argus II retinal prosthesis subjects. Transl Vis Sci Technol. 2013;2(4):1.PubMedPubMedCentralCrossRef
24.
Zurück zum Zitat Ehlers J, Gupta P, Farsiu S, Maldonado R, Kim T, Toth S, Mruthyunjaya P. Evaluation of contrast agents for enhanced visualization in optical coherence tomography. Invest Ophthalmol Vis Sci. 2010;51(12):6614–9.PubMedCrossRef Ehlers J, Gupta P, Farsiu S, Maldonado R, Kim T, Toth S, Mruthyunjaya P. Evaluation of contrast agents for enhanced visualization in optical coherence tomography. Invest Ophthalmol Vis Sci. 2010;51(12):6614–9.PubMedCrossRef
Metadaten
Titel
Influence of optic media of the human eye on the imaging of Argus® II retinal prosthesis with intraoperative spectral-domain optical coherence tomography
verfasst von
Lyubomyr M. Lytvynchuk, MD, PhD
Christiane I. Falkner-Radler, MD
Andrzej Grzybowski, MD, PhD
Carl G. Glittenberg, MD
Farnusch Shams-Mafi, MD
Siamak Ansari-Shahrezaei, MD
Susanne Binder, MD
Publikationsdatum
29.04.2019
Verlag
Springer Vienna
Erschienen in
Spektrum der Augenheilkunde / Ausgabe 1/2020
Print ISSN: 0930-4282
Elektronische ISSN: 1613-7523
DOI
https://doi.org/10.1007/s00717-019-0429-x

Weitere Artikel der Ausgabe 1/2020

Spektrum der Augenheilkunde 1/2020 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.