01.10.2010 | Original research article | Ausgabe 2/2010

Documenta Ophthalmologica 2/2010

Inter-subject, inter-ocular and inter-session repeatability of the photopic negative response of the electroretinogram recorded using DTL and skin electrodes

Zeitschrift:
Documenta Ophthalmologica > Ausgabe 2/2010
Autoren:
Katharine E. Mortlock, Alison M. Binns, Yousef H. Aldebasi, Rachel V. North

Abstract

The photopic negative response (PhNR) has attracted interest as a flash ERG component reflecting inner retinal activity, with investigators adopting various approaches to analysing the response. This study has two principal aims: first to determine the most reliable technique for assessing the PhNR amplitude; secondly to compare the repeatability characteristics of the PhNR recorded using DTL and skin active electrodes. Electroretinograms were recorded in 31 subjects, using both electrode types, in response to a Ganzfeld red stimulus (Lee filter “bright red”; 1.76 log phot td.s; 4 Hz) presented over a steady blue background (Schott glass filter BG28; 3.9 log scot td). Sixteen subjects returned to assess repeatability. PhNR amplitude was measured from b-wave peak-to-PhNR trough, pre-stimulus baseline to trough, and from peak and baseline to a fixed time-point; a ratio of b-wave/PhNR amplitude was also calculated. Coefficients of variation (CoV), and inter-ocular and inter-session limits of agreement (LoA) were calculated for all measures. The ratio of b-wave/PhNR amplitude showed the lowest CoV (14.3% DTL; 23.2% skin), inter-ocular LoA (22.2% DTL; 25.0% skin), and inter-session LoA (22.8% DTL; 20.3% skin). The peak-to-trough and peak-to-fixed-time measurements were also consistently reliable. Least reliable measures were those measured from baseline. While skin electrode responses were significantly smaller than DTL responses (P < 0.0001), the variability was only slightly increased. This study suggests that peak-to-trough measurements are the most reliable means of measuring the PhNR and ratio calculation further improves repeatability. Skin electrodes provided a viable alternative to DTL electrodes for recording the PhNR.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 2/2010

Documenta Ophthalmologica 2/2010 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

06.08.2019 | Leitthema | Ausgabe 9/2019

Forschungs- und Entwicklungsbedarf in der Augenheilkunde („Unmet needs“)

Ein konsensbasierter Fahrplan des European Vision Institute (EVI) für die Jahre 2019 bis 2025

01.08.2019 | Erkrankungen der Hornhaut | CME | Ausgabe 8/2019

Neurotrophe Keratopathie

Grundlagen, Diagnostik und Therapie

22.07.2019 | DFP-Fortbildung | Ausgabe 4/2019 Open Access

Aktuelle Möglichkeiten der visuellen Rehabilitation