Abstract

Background

The surgical treatment of acetabular fracture has adverse outcomes and high risk, and minimally invasive method is a good way to reduce complications and improve hip joint function. This study is to investigate the treatment of certain acetabular fractures primarily involving the anterior column and quadrilateral plate using a limited pararectus approach and the anatomical plates.

Methods

A consecutive cohort of 17 patients with anterior displaced acetabular fractures were managed operatively with a limited approach and the anatomical plates. Ten patients had anterior column fractures, 1 patient had anterior wall fracture, 4 patients had transverse fractures and 2 patients had anterior column with posterior hemi-transverse fractures. The inferior half of the pararectus approach was adopted to open the medial window and to access the anterior column and the quadrilateral plate. The anatomical plates were used for internal fixation. Residual displacements were assessed on the postoperative CT scans using a standardized digital method. The surgical details, hip functional outcomes, and complications were noted.

Results

All of the patients were operated using the limited pararectus approach and the anatomical plates successfully. The mean operative time and blood loss were 90.9 min and 334.1 ml, respectively. The average postoperative residual gap and step displacement on CT were 2.9 mm and 0.7 mm, respectively. The radiological outcome was estimated according to the Matta score, ten of the cases were graded anatomical, six were graded imperfect, and one was graded poor. Follow up averaged 15 months. Functional outcomes were excellent for nine, good for six, and fair for two. It was noted that one case of peritoneal injury was repaired intraoperatively.

Conclusions

The limited pararectus approach with the advantages of less trauma, direct exposure to the anterior column and quadrilateral plate. The anatomical plates can fit with the surface of the acetabulum, which saves the time of remodeling plates during operation and facilitate fracture reduction. The combination approach can be a good choice for limited surgery of displaced anterior acetabular fractures especially involving the quadrilateral plate.
Begleitmaterial
Hinweise

Supplementary Information

The online version contains supplementary material available at https://​doi.​org/​10.​1186/​s12891-021-04034-w.
Sheng Yao and Kaifang Chen contributed equally to this work.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
CT
Computerized tomography
SD
Standard deviation
ORIF
Open reduction and internal fixation
AP
Anteroposterior
3D
Three-dimensional

Background

Multiple surgical approaches and implantations have been invented and modified for the treatment of acetabular fractures [16]. In 1960s, Letournel [1] described the standardized surgical treatment strategies, and some other approaches and algorithms have also contributed greatly to the management of acetabular fractures. However, open reduction and internal fixation of acetabular fractures are still accompanied by high hip replacement and dysfunction rate because of the complex anatomy and extensive surgical wound [79]. Several studies have shown that limited incision or minimally invasive methods with less tissue injuries and surgical complications can achieve good clinical results in the treatment of partially displaced acetabular fractures [1012]. Even though, it has not been widely used for acetabular fractures in clinical practice because blind manipulation under insufficient exposure makes anatomical reduction and fixation very difficult.
The pararectus approach had advantages of adequate visualization of the dome and quadrilateral plate, less complications, and easy to achieved anatomical reduction [3, 1315]. The fully exposed medial window of this approach enables direct visualization of the anterior column and quadrilateral plate, and allows palpation of the anterior aspect of the sacroiliac joint. An oblique mini-incision similar to the medial window of the pararectus approach was used to acquire closed reduction under finger palpate combined with screw fixation for acetabular transverse fractures [10]. The suprapectineal and infrapectineal plates are the most common methods for management of acetabular fractures involving the anterior column and quadrilateral plate [16, 17]. Generally, the remodeling of plate is very difficult due to the limitation of small incision and will increase operation time consumption [11].
This limited pararectus approach uses the medial window of the pararectus approach, bypassing the rectus abdominis and accessing closer to the anterior acetabulum, pelvic brim, and quadrilateral plate. The purpose of the preliminary study was to introduce our clinical experience in the treatment of acetabular fractures using the new approach and the anatomical suprapectineal and infrapectineal plates. We hypothesis that the limited approach could provide enough visualization for reduction and fixation of anterior acetabular fractures, and the anatomical plates, without the need for remodeling intraoperatively, could fit into the irregular acetabulum surface and facilitate the operation.

Patients and methods

Inclusion criteria:
(1)
Suffering from closed acetabular fracture with anterior column
 
(2)
The operation was performed using the limited pararectus approach and anatomical plate
 
(3)
Injury to operation time is less than 2 weeks.
 
Exclusion criteria:
(1)
Fractures without displacement
 
(2)
Fractures involving iliac wing or posterior wall requiring open reduction
 
(3)
Delayed or open acetabular fracture;
 
(4)
Age <  18 years
 
After institutional review board approval, a total of 17 consecutive cases of anterior acetabular fractures at a Level 1 trauma centre were treated operatively from March 2015 to December 2018 (Table 1). There were 12 males and 5 females, with an average age of 46.9 (range: 28–78, SD: 14.1). The fracture patterns were ten for anterior column, one for anterior wall, two for transverse, and four for anterior column with posterior hemitransverse. The initial causes of injury include traffic accident (10, 58.8%), fall from height (≧3 m)(6, 35.3%), and industrial accident (1,5.9%). The average time from injury to surgery was 6.8 days. All displaced acetabular fractures were routinely treated with skeletal traction preoperatively to relieve pain and maintain temporary reduction of hip joint. Open reduction and internal fixation (ORIF) were done through the limited approach, with longitudinal traction of the ipsilateral limbs and lateral traction of the greater trochanter, in needed. Deep venous thrombosis was prevented by low molecular weight heparin (2000 IU, qd). The operative time, intraoperative haemorrhage, perioperative complications and follow-up data were noted.
Table 1
Patient demographics and peri-operative data overview
No.
Sex
Age
Classificationa
Injury to surgery (day)
Operative time (min)
Blood loss (ml)
Internal Fixation
Complications
1
M
48
AC
3
45
100
Supra-pectineal plate
No
2
F
39
AW
4
50
150
Supra-pectineal plate
No
3
M
47
AC
4
80
350
Supra-pectineal plate
No
4
F
40
TR
10
110
550
Infra-pectineal and ilioischiatic plates
No
5
F
35
TR
14
100
750
Infra-pectineal and ilioischiatic plates
Peritoneal injury
6
M
45
AC
3
90
150
Supra- and infra-pectineal plates
No
7
M
71
AC
8
105
400
Supra-pectineal plate
No
8
M
60
TR
8
115
200
Infra-pectineal and ilioischiatic plates
No
9
M
29
AC
5
70
150
Supra- and infra-pectineal plates
No
10
M
28
AC
10
65
300
Infra-pectineal plate
No
11
F
44
TR
7
110
450
Infra-pectineal and ilioischiatic plates
No
12
M
47
AC-PHT
9
105
560
Infra-pectineal and ilioischiatic plates
No
13
M
78
AC
5
85
250
Supra- and infra-pectineal plates
No
14
M
54
AC
7
50
200
Supra- and infra-pectineal plates
No
15
M
60
AC
6
90
350
Supra- / infra-pectineal plates and ioischiatic plates
No
16
F
43
AC-PHT
4
150
450
Supra-pectineal plate
No
17
M
30
AC
9
125
320
Supra- and infra-pectineal plates
No
Mean and standard deviation
 
46.9 ± 14.1
 
6.8 ± 3.0
90.9 ± 28.7
334.1 ± 177.3
  
a Letournel’s classification, AC anterior column, AW anterior wall, PHT posterior hemi transverse, TR transverse

Surgical technique

The patient was positioned supine on a flat radiolucent operative table allowing intraoperative fluoroscopic visualization. The ipsilateral limb was free to stretch with the hip joint flexed to relax the iliopsoas and external iliac/femoral neurovascular bundle. Chief surgeon was positioned on the contralateral side of the injured acetabulum. The skin incision was made with the inferior half of the pararectus approach [3] (Fig. 1). A mini-incision was made at the lateral edge of the rectus abdominis muscle, just medial to the external iliac neurovascular bundle and above the inguinal ligament. The approach was located in the triangle area between the external iliac vascular, inguinal ligament and rectus abdominis muscle. The sheath of rectus abdominis was partially dissected, while the inferior epigastric vascular bundle and spermatic cord/uterine round ligament were detached and drawn laterally with the external iliac neurovascular bundle (Fig. 2a). The fascia transversalis was separated bluntly to enter the extraperitoneal space. A S-hook was used to pull the peritoneum medially to protect the bladder and intestines. Anastomosis (corona mortis) between the inferior epigastric vascular/ external iliac vessels and obturator vessels was identified and ligated on the surface of the suprapubic root. The periosteum was dissected from the anterior pelvic brim to safely separate most of the quadrilateral plate and anterior wall of the acetabulum. The anterior aspect of the sacroiliac joint could be touched proximally. The obturator neurovascular bundle was carefully pulled downward together with the periosteum to avoid nerve injury (Fig. 2b).
Longitudinal and lateral traction facilitated reduction of displaced acetabular fractures. Reduction tools such as clamps and rods were used to reduce the displaced lower anterior column and quadrilateral plate fracture under direct vision. An anatomical plate was placed inferior the pelvic brim for firm fixation of the quadrilateral plate, and an anatomical suprapectineal plate was used for fixation of the anterior column and wall (Fig. 3).

Imaging review

All patients received anteroposterior (AP) and Judet oblique views as well as CT scans pre- and post-operative. Standard procedures were used for multi-plane and three-dimensional (3D) reconstruction of CT images. A standardized procedure [18] was used to evaluate the residual step and gap displacement only in the weight-bearing dome (the upper 1 cm of the acetabulum) on postoperative CT scans. The greatest residual displacement in any of the axial, sagittal, or coronal plane views was measured and recorded. A circular template was drawn to fit along the acetabular articular surface and the gap displacement was measured along its perimeter. The step was obtained by the difference between the distance from the maximum displacement point of the fragment to the centre of the circle and the radius. An experienced radiologist (JL) and a trauma fellow (YLW) who were unaware of the patient’s surgical and clinical outcomes graded the reduction quality on postoperative X-ray images independently according to the Matta criteria [19]: anatomical (0–1 mm), imperfect (2–3 mm), or poor (> 3 mm). Imaging review was accomplished in the Picture Archiving and Communication Systems (PACS) and standard tools were used for the measurements.

Postoperative management and follow-up

Functional muscle contraction training begins at the next day after surgery, and hip rehabilitation training progressively transitions from passive exercise to active exercise. Touchdown weight bearing was permitted the next day and continued for 6 weeks. Further partial weight bearing was permitted with progression to full weight-bearing. Patients were regularly followed up at an interval of 1 month, 3 months, 6 months and 1 year and then yearly if required. The modified Merle d’Aubigné and Postel score [20] was used to estimate the follow up functional outcomes. The sum of the individual scores (pain, gait, and range of motion of the hip) was classified as excellent (18 points), very good (17 points), good (15 or 16 points), fair (13 or 14 points), or poor (< 13 points).

Results

The mean operative time was 90.9 ± 28.7 min (range: 45–150) and the mean blood loss was 334.1 ± 177.3 ml (range: 100–750). The mean residual gap and step displacement of the fractures was 2.9 ± 1.0 mm and 0.7 ± 0.6 mm, respectively. According to the Matta score, the quality of surgical reduction was graded as “anatomical” in 10 (58.8%) cases, “imperfect” in 6 (35.3%) cases, and “poor” in 1 (5.9%) case. All patients were regularly followed up for a period of at least 1 year, with the average 15 months (range: 12–27). One case of peritoneal injury occurred at the junction of the vas deferens and the peritoneum, and was repaired intraoperatively. Wounds healed within 2 weeks and there were no complications like infection and fat liquefaction. Functional healing of the fracture was achieved in all patients, with an average time of 12 weeks (range: 8–15), and no secondary displacement or implant failure was observed. Based on the Merle d’Aubigne and Postel score system [20], the functional outcomes were excellent in 9(52.9%) cases, good in 6(35.3%) cases, fair in 2(11.8%) cases (Table 2).
Table 2
Postoperative CT measurements, radiological and functional results (means ± standard deviation or number (percentage))
Parameter
value
CT measurements
 Mean maximal gap (mm)
2.9 ± 1.0
 Mean maximal step (mm)
0.7 ± 0.6
Radiological outcome (Matta)
 Anatomical (<  1 mm)
10(58.8%)
 Imperfect (2–3 mm)
6(35.3%)
 Poor (>  3 mm)
1(5.9%)
Merle D’Aubigne-Postel score
 Excellent (18)
9(52.9%)
 Good (15–17)
6(35.3%)
 Fair (13–14)
2(11.8%)
 Poor (< 13)
non

Discussion

Extensive surgical approach for acetabular fractures is often accompanied by the possibility of perioperative complications such as infection, blood loss and neurovascular damage [3, 21]. Although closed reduction and minimally invasive surgery decrease surgical complications, but it is difficult to achieve anatomical reduction of articular surface [10]. The limited pararectus approach we used did not dissect the spermatic cord (or round ligament) and extra-iliac vascular nerve bundle, thereby reducing the risk of iatrogenic neurovascular injuries and complications. And it helped to achieve good reduction quality and functional results. Since it is located in the lateral margin of the rectus abdominis, the exposure of the anterior wall and quadrilateral plate will not be blocked by the rectus abdominis as happened in the modified Stoppa approach [22, 23]. We believe that direct and adequate exposure of fractures is instrumental in achieving anatomical reduction. On the other hand, owing to the limitation of minimally invasive incision, it is difficult and time-consuming to remodel the plate intraoperatively. The anatomical plate in this study is designed according to the physiological anatomical morphology, which makes it has good congruity to the irregular pelvis and has the function of auxiliary reduction (Fig. 4) [17].
The average operative time and blood loss were less than that of extensive surgical approach. Keel reported that the average operative time and the mean blood loss of the pararectus approach were 197 min and 1700 ml, respectively [3]. Using the modified Stoppa approach described by Sagi the operation time and blood loss were 263 min and 750 ml, respectively [16]. While by using an oblique mini-incision, Farouk [10] reported an average blood loss of 110 ml and an average operating time of 95 min. In our case series, the mean blood loss of 334.1 ml is more than Farouk `s, but significantly less than that of the established procedures published previously [13, 5]. Moreover, average operative time of 90.9 min in our sample, which is comparable to Farouk `s study. The wound of the limited pararectus approach is very small which may be the main reason for lower blood loss.
We consider that standardized image reading ensures rigorous evaluation of surgical reduction. On postoperative CT scans, the mean residual gap and step displacement was 2.9 mm and 0.7 mm, respectively. The anatomical and imperfect reduction rate was 94.1%. The functional outcome at the last follow-up were graded as good and excellent in 88.2% patients. The clinical result is comparable to the previous research [1, 3, 15, 16, 24]. Good radiological and clinical results are derived from the adequate visualization of fracture sites and valid fixation of the anatomical plates.
Traditionally, the suprapectineal and infrapectineal plates which are used to fix the anterior column and quadrilateral plate are usually inserted using the standard ilioinguinal and modified Stoppa approaches. The good congruity of the plate is obtained by reshaping the reconstruction plate intraoperatively. Owing to the limitation of the minimal incision in our study, the bone surface was not exposed fully, which made it difficult and time-consuming to reshape plate during operation. In recent years, some new anatomic plates instead of conventional reconstruction plate have been used for buttress and span fixation of the quadrilateral plate and medial surface of the posterior column [17, 25]. The anatomic plates have good biomechanical properties and congruity with the irregular acetabulum surface, which make the fixation more valid and easier. Moreover, in this study, we observed that the displacement between the fragment and the intact part was further reduced as the lag screw was inserted into the plate. Nevertheless, the relatively simple type of fractures in our cases facilitates the reduction, fixation and clinical outcome too. We consider that strict selection of patients is the key to ensure good surgical results, especially when using minimally invasive approaches.
The relative minimally invasive pararectus and modified Stoppa approaches are also accompanied with incidence of surgery-related complications ranging from 10.7 to 45.4% [13, 26]. It is easy to understand that extensive dissection of the neurovascular bundle and inguinal canal and intraoperative overstretching are supposed to be the main causes of surgical complications. The limited pararectus approach passes through the soft tissue space between the rectus abdominis and the neurovascular bundles to obtain closer access to anterior wall, anterior column and quadrilateral plate of the acetabulum. In this area, the extraperitoneal reflexed spermatic cord is the major obstacle of surgical exposure, pulling outward may be the cause of peritoneal rupture which occurred in one of our case. However, Both the wound and fracture were healed rapidly during follow-up, and no wound infection, fat liquefaction, ectopic ossification, or secondary displacement was recorded.
Closed reduction of displaced acetabular fractures may be minimally invasive, but finger palpation blindly for fracture manipulation and assessment of reduction may be inaccurate and may result in miss diagnosis of rotational displacement and more radiation exposure of medical staff [10]. However, in this study, the mini-pararectus approach might be a good choice for certain types of acetabular fractures involving low anterior column and quadrilateral plate, including anterior wall, anterior column with quadrilateral plate, simple transverse and anterior column with posterior hemitransverse fractures without iliac fragment. It can provide direct view through the soft tissue space, which decreases the risk of neurovascular injury and is beneficial to achieve anatomical reduction.
There are several limitations to this study. First, it is required to extend the minimal incision to the standard pararectus approach for the treatment of high anterior column fractures involving iliac wing and dome fragments in the elderly, which may be the main disadvantage of this approach. Besides, the minimal approach might not be suitable for delayed cases, patients with obesity or lower abdominal surgery history. Besides, we think the current problems of the two plates mainly include: (1) the length and model are invariable, so it is difficult to completely fix a long pelvic brim fracture; (2) the plasticity is not as good as that of stainless steel reconstruction plate, and excessive shaping will reduce the strength of the plate. This is a preliminary study on the use of the limited pararectus approach for the treatment of acetabular fractures. A prospective comparative study involving more cases needs to be further carried out, and long-term follow-up of patients is needed to be performed in the future.

Conclusions

Based on the results of this study, the limited approach has advantages of less trauma, direct exposure to the anterior column and quadrilateral plate. This limited approach eliminates the need for direct dissection of important neurovascular bundle, avoids the obstruction of rectus abdominis, which makes it safe and easy. Intraoperative, this limited incision can provide sufficient view which improves the operation efficiency. The new anatomical plates can fit with the surface of acetabulum, which saves the time of remodeling plates during operation and facilitate fracture reduction. The combination approach can be a good choice for limited surgery of displaced anterior acetabular fractures especially involving the quadrilateral plate.

Acknowledgements

The authors gratefully acknowledge the Double Medical Technology Inc. (Xiamen, China) for providing the implants (No. 20163462504) in this study.
All patients agreed and signed to participate on this clinical trial. All procedures performed in this study involving human participants were in accordance with the bioethical standards of the institutional and the national research committee (Ethics Committee of the Union Hospital, Tongji Medical College, Huazhong University of Science and Technology) and with the 1964 Helsinki declaration and its later amendments.
Not applicable.

Competing interests

The authors declare that they have no competing interests.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Anhänge

Supplementary Information

Literatur
1.
Zurück zum Zitat Judet R, Judet J, Letournel E. Fractures of the acetabular classification and surgical approaches for open reduction. J Bone Joint Surg Am. 1964;46-A(8):1615–47.CrossRef Judet R, Judet J, Letournel E. Fractures of the acetabular classification and surgical approaches for open reduction. J Bone Joint Surg Am. 1964;46-A(8):1615–47.CrossRef
2.
Zurück zum Zitat Cole JD, Bolhofner BR. Acetabular fracture fixation via a modified Stoppa limited intrapelvic approach. Description of operative technique and preliminary treatment results. Clin Orthop Relat Res. 1994;305:112–23.CrossRef Cole JD, Bolhofner BR. Acetabular fracture fixation via a modified Stoppa limited intrapelvic approach. Description of operative technique and preliminary treatment results. Clin Orthop Relat Res. 1994;305:112–23.CrossRef
3.
Zurück zum Zitat Keel MJ, Ecker TM, Cullmann JL, Bergmann M, Bonel HM, Buchler L, et al. The Pararectus approach for anterior intrapelvic management of acetabular fractures: an anatomical study and clinical evaluation. J Bone Joint Surg Br. 2012;94(3):405–11.CrossRef Keel MJ, Ecker TM, Cullmann JL, Bergmann M, Bonel HM, Buchler L, et al. The Pararectus approach for anterior intrapelvic management of acetabular fractures: an anatomical study and clinical evaluation. J Bone Joint Surg Br. 2012;94(3):405–11.CrossRef
4.
Zurück zum Zitat Aigner R, Hellige R, Knippel S, Oberkircher L, Ruchholtz S, Buecking B. Internal fixation of acetabular fractures in an older population using the TIMI approach - midterm results of a prospective study. Injury. 2017;48(4):890–6.CrossRef Aigner R, Hellige R, Knippel S, Oberkircher L, Ruchholtz S, Buecking B. Internal fixation of acetabular fractures in an older population using the TIMI approach - midterm results of a prospective study. Injury. 2017;48(4):890–6.CrossRef
5.
Zurück zum Zitat Chen K, Ji Y, Huang Z, Navinduth R, Yang F, Sun T, et al. Single modified Ilioinguinal approach for the treatment of Acetabular fractures involving both columns. J Orthop Trauma. 2018;32(11):e428–e34.CrossRef Chen K, Ji Y, Huang Z, Navinduth R, Yang F, Sun T, et al. Single modified Ilioinguinal approach for the treatment of Acetabular fractures involving both columns. J Orthop Trauma. 2018;32(11):e428–e34.CrossRef
6.
Zurück zum Zitat Mayo K, Unno F. The Ilioinguinal Surgical Approach Using a Modified Medial Window: Origin, Evolution, and Applications. A 34-Year Perspective. J Orthop Trauma. 2019;33(Suppl 2):S14–20.CrossRef Mayo K, Unno F. The Ilioinguinal Surgical Approach Using a Modified Medial Window: Origin, Evolution, and Applications. A 34-Year Perspective. J Orthop Trauma. 2019;33(Suppl 2):S14–20.CrossRef
7.
Zurück zum Zitat Keel MJ, Tomagra S, Bonel HM, Siebenrock KA, Bastian JD. Clinical results of acetabular fracture management with the Pararectus approach. Injury. 2014;45(12):1900–7.CrossRef Keel MJ, Tomagra S, Bonel HM, Siebenrock KA, Bastian JD. Clinical results of acetabular fracture management with the Pararectus approach. Injury. 2014;45(12):1900–7.CrossRef
8.
Zurück zum Zitat Verbeek DO, van der List JP, Tissue CM, Helfet DL. Predictors for long-term hip survivorship following Acetabular fracture surgery: importance of gap compared with step displacement. J Bone Joint Surg. 2018;100(11):922–9.CrossRef Verbeek DO, van der List JP, Tissue CM, Helfet DL. Predictors for long-term hip survivorship following Acetabular fracture surgery: importance of gap compared with step displacement. J Bone Joint Surg. 2018;100(11):922–9.CrossRef
9.
Zurück zum Zitat Verbeek DO, Ponsen KJ, van Heijl M, Goslings JC. Modified Stoppa approach for operative treatment of acetabular fractures: 10-year experience and mid-term follow-up. Injury. 2018;49(6):1137–40.CrossRef Verbeek DO, Ponsen KJ, van Heijl M, Goslings JC. Modified Stoppa approach for operative treatment of acetabular fractures: 10-year experience and mid-term follow-up. Injury. 2018;49(6):1137–40.CrossRef
10.
Zurück zum Zitat Farouk O, Kamal A, Badran M, El-Adly W, El-Gafary K. Minimal invasive Para-rectus approach for limited open reduction and percutaneous fixation of displaced acetabular fractures. Injury. 2014;45(6):995–9.CrossRef Farouk O, Kamal A, Badran M, El-Adly W, El-Gafary K. Minimal invasive Para-rectus approach for limited open reduction and percutaneous fixation of displaced acetabular fractures. Injury. 2014;45(6):995–9.CrossRef
11.
Zurück zum Zitat Zhuang Y, Cao S, Lin Y, Li R, Wang G, Wang Y. Minimally invasive plate osteosynthesis of acetabular anterior column fractures using the two-incision minimally invasive approach and a preshaped three dimension plate. Int Orthop. 2016;40(10):2157–62.CrossRef Zhuang Y, Cao S, Lin Y, Li R, Wang G, Wang Y. Minimally invasive plate osteosynthesis of acetabular anterior column fractures using the two-incision minimally invasive approach and a preshaped three dimension plate. Int Orthop. 2016;40(10):2157–62.CrossRef
12.
Zurück zum Zitat Wu XB, Wang JQ, Sun X, Zhao CP. Guidance for treatment of pelvic Acetabular injuries with precise minimally invasive internal fixation based on the Orthopaedic surgery robot positioning system. Orthop Surg. 2019;11(3):341–7.CrossRef Wu XB, Wang JQ, Sun X, Zhao CP. Guidance for treatment of pelvic Acetabular injuries with precise minimally invasive internal fixation based on the Orthopaedic surgery robot positioning system. Orthop Surg. 2019;11(3):341–7.CrossRef
13.
Zurück zum Zitat Mardian S, Schaser KD, Hinz P, Wittenberg S, Haas NP, Schwabe P. Fixation of acetabular fractures via the ilioinguinal versus pararectus approach: a direct comparison. Bone Joint J. 2015;97-B(9):1271–8.CrossRef Mardian S, Schaser KD, Hinz P, Wittenberg S, Haas NP, Schwabe P. Fixation of acetabular fractures via the ilioinguinal versus pararectus approach: a direct comparison. Bone Joint J. 2015;97-B(9):1271–8.CrossRef
14.
Zurück zum Zitat Keel MJ, Siebenrock KA, Tannast M, Bastian JD. The Pararectus approach: a new concept. JBJS Essent Surg Tech. 2018;8(3):e21.CrossRef Keel MJ, Siebenrock KA, Tannast M, Bastian JD. The Pararectus approach: a new concept. JBJS Essent Surg Tech. 2018;8(3):e21.CrossRef
15.
Zurück zum Zitat Von Ruden C, Wenzel L, Becker J, Thannheimer A, Augat P, Woltmann A, et al. The pararectus approach for internal fixation of acetabular fractures involving the anterior column: evaluating the functional outcome. Int Orthop. 2019;43(6):1487–93.CrossRef Von Ruden C, Wenzel L, Becker J, Thannheimer A, Augat P, Woltmann A, et al. The pararectus approach for internal fixation of acetabular fractures involving the anterior column: evaluating the functional outcome. Int Orthop. 2019;43(6):1487–93.CrossRef
16.
Zurück zum Zitat Sagi HC, Afsari A, Dziadosz D. The anterior intra-pelvic (modified rives-stoppa) approach for fixation of acetabular fractures. J Orthop Trauma. 2010;24(5):263–70.CrossRef Sagi HC, Afsari A, Dziadosz D. The anterior intra-pelvic (modified rives-stoppa) approach for fixation of acetabular fractures. J Orthop Trauma. 2010;24(5):263–70.CrossRef
17.
Zurück zum Zitat Chen K, Yang F, Yao S, Xiong Z, Sun T, Guo X. Biomechanical comparison of different fixation techniques for typical Acetabular fractures in the elderly: the role of special quadrilateral surface buttress plates. J Bone Joint Surg. 2020;102(14):e81. Chen K, Yang F, Yao S, Xiong Z, Sun T, Guo X. Biomechanical comparison of different fixation techniques for typical Acetabular fractures in the elderly: the role of special quadrilateral surface buttress plates. J Bone Joint Surg. 2020;102(14):e81.
18.
Zurück zum Zitat Verbeek DO, van der List JP, Moloney GB, Wellman DS, Helfet DL. Assessing postoperative reduction after Acetabular fracture surgery: a standardized digital computed tomography-based method. J Orthop Trauma. 2018;32(7):e284–e8.CrossRef Verbeek DO, van der List JP, Moloney GB, Wellman DS, Helfet DL. Assessing postoperative reduction after Acetabular fracture surgery: a standardized digital computed tomography-based method. J Orthop Trauma. 2018;32(7):e284–e8.CrossRef
19.
Zurück zum Zitat Matta JM. Fractures of the acetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury. J Bone Joint Surg Am. 1996;78(11):1632–45.CrossRef Matta JM. Fractures of the acetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury. J Bone Joint Surg Am. 1996;78(11):1632–45.CrossRef
20.
Zurück zum Zitat D'Aubigne RM, Postel M. The classic: functional results of hip arthroplasty with acrylic prosthesis. Clin Orthop Relat Res. 2009;467(1):7–27.CrossRef D'Aubigne RM, Postel M. The classic: functional results of hip arthroplasty with acrylic prosthesis. Clin Orthop Relat Res. 2009;467(1):7–27.CrossRef
21.
Zurück zum Zitat Huang H, Chen L, Mao G, Bach J, Xue Q, Han F, et al. The 2019 yearbook of Neurorestoratology. J Neuro-Oncol. 2020;08(01):1–11.CrossRef Huang H, Chen L, Mao G, Bach J, Xue Q, Han F, et al. The 2019 yearbook of Neurorestoratology. J Neuro-Oncol. 2020;08(01):1–11.CrossRef
22.
Zurück zum Zitat Bastian JD, Savic M, Cullmann JL, Zech WD, Djonov V, Keel MJ. Surgical exposures and options for instrumentation in acetabular fracture fixation: Pararectus approach versus the modified Stoppa. Injury. 2016;47(3):695–701.CrossRef Bastian JD, Savic M, Cullmann JL, Zech WD, Djonov V, Keel MJ. Surgical exposures and options for instrumentation in acetabular fracture fixation: Pararectus approach versus the modified Stoppa. Injury. 2016;47(3):695–701.CrossRef
23.
Zurück zum Zitat Liu Y, Yang H, Li X, Yang SH, Lin JH. Newly modified Stoppa approach for acetabular fractures. Int Orthop. 2013;37(7):1347–53.CrossRef Liu Y, Yang H, Li X, Yang SH, Lin JH. Newly modified Stoppa approach for acetabular fractures. Int Orthop. 2013;37(7):1347–53.CrossRef
24.
Zurück zum Zitat Hammad AS, El-Khadrawe TA. Accuracy of reduction and early clinical outcome in acetabular fractures treated by the standard Ilio-inguinal versus the Stoppa/iliac approaches. Injury. 2015;46(2):320–6.CrossRef Hammad AS, El-Khadrawe TA. Accuracy of reduction and early clinical outcome in acetabular fractures treated by the standard Ilio-inguinal versus the Stoppa/iliac approaches. Injury. 2015;46(2):320–6.CrossRef
25.
Zurück zum Zitat Kistler BJ, Smithson IR, Cooper SA, Cox JL, Nayak AN, Santoni BG, et al. Are quadrilateral surface buttress plates comparable to traditional forms of transverse acetabular fracture fixation? Clin Orthop Relat Res. 2014;472(11):3353–61.CrossRef Kistler BJ, Smithson IR, Cooper SA, Cox JL, Nayak AN, Santoni BG, et al. Are quadrilateral surface buttress plates comparable to traditional forms of transverse acetabular fracture fixation? Clin Orthop Relat Res. 2014;472(11):3353–61.CrossRef
26.
Zurück zum Zitat Shazar N, Eshed I, Ackshota N, Hershkovich O, Khazanov A, Herman A. Comparison of acetabular fracture reduction quality by the ilioinguinal or the anterior intrapelvic (modified rives-Stoppa) surgical approaches. J Orthop Trauma. 2014;28(6):313–9.CrossRef Shazar N, Eshed I, Ackshota N, Hershkovich O, Khazanov A, Herman A. Comparison of acetabular fracture reduction quality by the ilioinguinal or the anterior intrapelvic (modified rives-Stoppa) surgical approaches. J Orthop Trauma. 2014;28(6):313–9.CrossRef
Metadaten
Titel
Internal fixation of anterior acetabular fractures with a limited pararectus approach and the anatomical plates: preliminary results
verfasst von
Sheng Yao
Kaifang Chen
Fengzhao Zhu
Jia Liu
Yulong Wang
Lian Zeng
Yizhou Wan
Yanzhen Qu
Liang Yang
Xiaodong Guo
Xu Yang
Publikationsdatum
01.12.2021
Verlag
BioMed Central
Erschienen in
BMC Musculoskeletal Disorders / Ausgabe 1/2021
Elektronische ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-021-04034-w